Aiphone LE-SS, LE-SSR, LE-SS-GP User Manual

Vandal Resistant Sub Stations for LAF-C, LEF, LEM, AP-M, MP-S Systems
- INSTRUCTIONS -
The LE-SS and LE-SSR are 2-gang stainless steel vandal proof and weather resistant sub stations designed for use with the systems listed above. The LE-SS-GP is the gold-plated model. They are constructed with 12 gauge stainless steel, and the LE-SSR features a red mushroom call button . T h e units either flush mount into a 2-gang box, or surface mount with the SBX-2G (SBX-GP2 for gold subs). Each unit includes tamper proof screws and a tool for installation.
INSTALLATION:
1. For flush mounting, install sub station in standard 2-gang electrical box with min. 2-1/2" depth.
2. For surface mounting, install sub station in the SBX-2G(-GP2) surface mount enclosure.
3. IMPORTANT! These units are designed for use in normal weather conditions, and to allow drainage and evaporation of moisture that naturally gets into the unit. Do not apply caulking or silicone sealant around the unit when installing, and do not use weather stripping around the perimeter of the box when mounting. If sealing the unit is required, the bottom must remain unsealed.Sealing the unit will prevent or inhibit moisture from dissipating from inside the unit, which may cause corrosion or deterioration to the internal components over time.
MOUNTING:
LE-SSR/SS-GP
LE-SS
2-GANG BOX
LEM SYSTEM:
LEM Master LE-SS(R,-GP) Sub
Power
Source*
+
-
LEF SYSTEM:
LEF, LAF/LDF
Master Station*
PS-1225UL
+
-
Page 1
1 2 ~
10
E +
-
1 E
*LEM-1 or LEM-3: Use SKK-620
+
(6V DC)
-
LEM-1DL: Use PT-1210N (or any source providing 12-16V AC or 12-24V DC)
LE-SS(R,-GP) Sub
TORX
screws
Red
Blk*
Grn
Do not apply sealant between unit and box.
Red Blk*
Grn
LE-SS(R,-GP) Sub
Red
Blk*
Grn Brn
Org
* In single master LEF system only, 2 conductors homerun can be used with the BLK and GRN wires tied together and "E" and "-" jumpered at the master.
Leave brown, orange, or yellow wires disconnected.
Yel
Jumper Green & Black wires together. Leave brown, orange, and yellow wires disconnected.
MP-S SYSTEM:
MP-S Master
PS-1225UL
+
-
AP-M SYSTEM:
LE-SS/LE-SSR
Red
Blk
Grn
Brn
Org
Brn Yel
1 (2) (3)
E
+
-
AP-M Master
1 E 2 E
~
10
E
LE-SS(R,-GP) Sub
Red Blk*
Grn
LE-SS(R,-GP) Sub
Red
Blk Grn Brn Org Brn
Yel
WIRE DEFINITIONS:
Red: Hot side of speaker & call switch, connect to # of master Black: Common communication, connect to E of master Green: Negative side of call switch Brown: Call switch, left intact for LEM, LEF.
Jumpered with Org/Yel for AP-M Orange: Additional resistor circuit for AP-M Yellow: Additional resisto r circuit for AP-M
Jumper Green & Black wires together. Leave brown, orange, and yellow wires disconnected.
Modifying LE-SS/-SSR/-GP to work with AP-M Master:
1. Cut Brown wire on CP038. (Brown wire jumpers J8 to J10.)
2. Tie Brown wire from J8 to Orange wire on J9.
3. Tie Brown wire from J10 to Yellow wire on J11.
Tie Blk and Grn wires together for all installations with the MP-S and AP-M systems.
Intercom wiring must be run at least 20" away from any AC wiring, fluorescent lighting, dimmer switches, or any other electronic device that may cause interference.
SPECIFICATIONS:
Power Source: Supplied by master station Speaker: 20 ohms, 4W, 2.5" diameter, water proof and puncture resistant, 2.4 oz. magnet Call Button: SPST call button. Call tone rings at master as long as button is held down. LED will remain lit for approx.
20 seconds (LEF, LEM-3, MP-3S, AP-5/10M only). Call tone only on LEM-1DL, LEM-1, and MP-1S.
LE-SS/-GP: Limited stop button. LE-SSR: Limited stop, red mushroom button Communication: Hands free at sub. Master is push-to-talk,release-to-listen. Faceplate: 12 gauge stainless steel Mounting: Flush mount into a 2-gang box. Surface mount into SBX-2G, sold separately. Tamper proof screws
included (6x32 for use with flush gang box) with T-10 TORX bit.
Use hardware included with SBX-2G when installing sub into that unit. Terminations: Color-coded prewired pigtails Operating Temperature: Speaker rating: -67°F to 187°F
LE-SS(G) Switch rating: 14 Wiring: 2 conductors in a 1-master LEF, MP-S, or AP-M system. 3 conductors in a multi-master LEF system.
Shielded cable is recommended. Use Aiphone #822202 for LEM or MP-S. Use #822202 or
#822203 for LEF. Use #832202 for AP-M systems. Wiring Distance: See system that unit is being used with for distance specifications. Dimensions (H x W x D): LE-SS/-SSR/-GP alone: 4-11/16" x 4-11/16" x 2"
With SBX-2G(-GP2): 4-3/4" x 4-7/8" x 3-5/8" (Top) 2-3/8" (Bottom)
Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005 (425) 455-0510 FAX (425) 455-0071
F to 158°F; LE-SSR Switch Rating: -22 F to 185°F
Toll Free Technical Support:
1-800-692-0200
E-mail tech@aiphone.com
LE-SS(R,GP) Instr.
0909BKJS