i Before actually installing the MYW-P3L equipment, the contents of
this Manual must be thoroughly read and understood. Also, refer to
Manuals packed with LEF, LEF-C, MYH-CU and MYH-CUB, etc.
A PRECAUTIONS ON INSTALLATION & WIRING
® AlPHONE
Zii; Warning
(Negligence could result in death or
serious injury to people)
Precautions
(Negligence could result in injury to peopie
or damage to property)
: General Precautions
A
Warning
1. Do not use any other power supply than of Aiphone or
specified by Aiphone to connect to terminals +, - on
MYW-P3L. Doing so can cause fire or damage
the unit.
2. Do not change or modify MYW-P3L equipment. (D
3. The MYW-P3L equipment must not be exposed to
water or any other liquid.
4. Do not open MYW-P3L without first unplugging power
supply(ies) to prevent electric shock.
5. Make sure wires are connected properly before
plugging in the power supply(ies).
6. Keep AC cord free from being pulled or crushed.
7. Do not plug or unplug with wet hands.
8. Keep AC outlet away from moisture
and dust.
A
Caution
1. Mount the MYW-P3L on wall in a convenient location,
but not where it could be bumped or jarred.
0
0
(§): Prohibitions to subject the unit to water.
^: Prohibitions to dismantle the unit.
@ : Take the unit to earth ground
2. Do not install MYW-P3L equipment in any of the
following locations, as it may cause the system to
malfunction;
• High or extreme cold temperature area: under direct
sunlight, near equipment that varies in temperature, in
front of air-conditioner, inside a refrigerated area, etc.
• Places subject to moisture or humidity extremes.
• Places subject to environmental conditions, such as oil,
dust, chemicals, salt, etc. ^
• Places subject to constant vibration or impact. ^
General Precautions
A
1. The MYW-P3L is not operable during a power failure.
2. In areas where broadcasting station antennas are close
by, MYW-P3L equipment may be affected by radio
frequency interference.
3. Keep all DC wiring at least 30cm, 20” away from
AC100~240V wiring, fluorescent lighting, or dimmer
switches. Cross AC wiring at a 90° angle.
MYW-P3L integrates max. 3 PanTilt door stations with LEF or LEF-C Selective Call Intercoms, and
provides selective control of door strikes and/or lights. Add MYH-CU or MYH-CUB monitors for viewing
video door stations.
Basic configuration
MY-DC/A
Intercoms & Accessories available
MY Series door stations
• Full pan/tilt • Prism pan/tilt
control
,
2
2
^2
--
7^^
-----
WIYW-P3L
5 common
RY-RA
One RY-PA per EL-9S
+ 2 wires
per door + 1 wire
per inside station, looped
Wide-angle
fixed camera
Overhead camera
Package Contents
3-PanTilt door adaptor
(MYW-P3L)
Packet of screws
Installation & Operation Manual
Door release
EL-9S, AC 12V, 0.35A.
MY-CA
Video monitors & LEF intercoms
MYH-CU & LEF-10S, etc. MYH-CUB & LEF-10C, etc.
NAMES AND FEATURES
MY-DS
Chime, Ali Caii & Music Adaptor
BG-10C: Requires DC12V, 2.5A power supply
(PS-12F in USA), or BGR-10A Music Center
w/DC 24V power supply{PS-24C in USA).
Features
Cable inlet
Cut off here
Single-gang wall mounting.
Cable inlet on bottom or on top.
-Terminal
blocks
'Single-gang
mounting
Three entry controls. Provides video & chime
tone activation, door release & auxiliary light
activation.
Video output to MYH monitors, with separate
cable run. Audio output to LEF network (w/chime
tone activation).
-Cable inlet
Reset switch on back of front case.
Standard video output connection
(requires connector #261380 in USA).
IF-DA for audio
Requires RY-PA relay per entry and
an AC transformer (PT-1210N in USA).
DC 18V Video power supply
PS-18E (PS-18C in N. America)
DC 12V Intercom power supply
PS-12A, PS-12B or PS-12M
(PS-12C in N. America)
INSTALLATION
■ System configuration
The MYW-P3L provides a video system with up to 3 PanTilt doors and 2 monitors for LEF or LEF-C
Intercom. (Additional monitors can be added, along with PS-18C or PS-18E power supply.)
MY-DC/A
Entry area: PanTilt door station, or MYW-CA w/MY-CA and lE/IF door station.
Room area: Chime, All Call & Music adaptor, either BG-10C or BGR-10A (USA only) may be installed.
Terminal block layouts
There is no interconnect wires between MYH monitor and LEF intercom.
Up to 3 monitors can be added with a supplementary power supply (Max. 75m, 245’ to farthest monitor).
B1, B2:
18V+, 18V
U1, U2:
1A1,1A2
2A1,2A2
3A1,3A2
DA, DB, DC
E;
R:
12V+, 12V-:
EL2:
KA,KB,KC:
LA,LB,LC:
b1,b2,b3:
4A1,4A2,MOD:
A The unused term
Video signal output to MYH-CU(B).
DC 18V power input.
Monitor activation control
2-wire video input #1
2-wire video input #2
2-wire video input #3
Audio communication and chime activation
Common communication to LEF
Occupied control
DC 12V power input
Door release control
Selective video control from LEF intercom
Selective door release control
Selective external device control
Not used
inals must not be connected.
Terminal block layouts
BG-10C
or BGR-10A
For PanTilt door station(s), assign a selector button as from 10 for door 1,
9 for door 2,...
~_^Entrance
Terminals
Audio, video
Door strike control
Video control
Audio & chime transmit
LEF Selector button109
LEF Video control
Illumination control
-3
123
1A1.1A22A1,2A23A1,3A2
LA,12V+LB, 12V-T
KAKBKC
DADBDC
K10K9
b1
b2b3
LC,12V+
8
K8
INSTALLATION
Video monitor & power supply
MYW-P3L
■
B1
B2
18V
MYH-CU
or MYH-CUB
A1
A2
U1
U2
I
B1
B2
U1
U2
A
ES3
£
Q @ 13^
A Do not connect + to + wire between monitors powered by different power supplies.
I^gnn ; PS-18C or PS-18E
• Impedance-matching switch: Set to OFF on all monitors, except on the last monitor.
• Intercom wires must not be in the same jacketed cable.
Door release
EL-9S
MYW-P3L
Door release wires must
be in separate jacketed
cables from video wires.
Auxiliary lights
U1
U2
- A1
- A2
MYW-P3L
U1
U2
-t-
B18
B1
B2
1
MOUNTING
1. Push button on the bottom, and lift front case off
of chassis.
2. Disconnect the MYW-P3L unit from chassis.
3. Mount the chassis to wall or single-gang box.
4. Pull in cables and make wire terminations.
5. Reconnect and mount the MYW-P3L to chassis and
lock.
-4-
l|
WIRING DIAGRAMS
1. Full PanTilt door integration
PanTilt door
No.10
No-9
No.8
PanTilt video monitors to LEF intercom (any)
6 common
+2 per entry
+1 per inside station
(for intercom)
• Distance
I.Ommo
MYW-P3L to PanTilt door100m
MYW-P3L to MYH-CU 175m
MYW-P3L to MYH-CU 235m
MYW-P3L to MYH-CU 2(*)
75m245'
MYW-P3L to Power supply5m
(*)With +/- wires doubled (total 8 wires)
18AWG
-5-
330'
245'
115'
16'
: PS-18Cor PS-18E
: PS-12C, PS-12A, PS-12B, or PS-12M.
★ Use "C" versions in N. America.
WIRING DIAGRAMS
2. BG-10C All Call & Music Integration with Chime Tone activation
3 PanTilt doors
No. 10
No.9
MYW-P3L
MYW-P3L
Video monitors
MYH-CUB
BG-10C
LEF-10C
: PS-12F AC120V, or DC12V, 2.5A.
]I: PS-18C AC120V, or PS-18E AC220-240V.
OPERATIONS
3 PanTilt doors
MYW-P3L
{»); Chime tone via BGR-10A Music Center or
BG-10C Ail Call/Music Adaptor.
Receiving
1. Press call button on MY-DC/A(or other video door station).
2. Call tone sounds, selector LED lights on LEF stations, and MYH-CU(B) monitor(s) turn on.
3. Depress the lit station selector button, and to establish communication.
4. Reply to the caller, depressing TALK button, and release to listen.
5. Depress and hold down key-marked button to activate door release.
* Call-in from another door turns on the selector LED, but does not activate video until current call is
finished.
Visual monitoring
1. Press MONITOR button to turn on monitor and view door #1.
2. Press MONITOR 2nd or 3rd time to view 2nd and 3rd door areas.
3. Press MONITOR again to turn off.
* The monitoring image remains on for 2-1/2 min.
* Call-in has priority over monitoring.
Pan and Tilting a door camera
Turn on MYH-CU(B) monitor(s) with MONITOR button, or depress an assigned selector button.
Scan door entry area or overhead MYW-CA surveillance area with PanTilt control pad on
MYH-CU(B).
-7-
TECHNICAL PRECAUTIONS
Wiring
1. Run 2 parallel conductor cable to PanTilt door station. Do not use multiple conductors with
other devices connected in the same cable. If the cable contains unused conductors, or other
device wires, including door strike, it will seriously affect image quality.
2. Be careful not to connect 18V + terminal (on MYW-P3L) with any video control terminals,
which can cause damage to MYW-P3L and monitors.
Reset switch
When system malfunctions, press RESET switch to re-initialize the
system (15 seconds per camera). The cameras are auto-initilized
after the system power supplies are plugged in.
Cleaning
Clean the MYW-P3L unit with a soft cloth dampened with neutral
household cleanser. Never use any abrasive cleaner or cloth.
SPECIFICATIONS (MYW-P3L)
Power source:
Power supply:
No. of door stations:
No. of video monitors:
Controls:
Wiring:
Distance:
* MYW-P3L to PanTilt door100m330'
* MYW-P3L to MYH-CU(B)
* MYW-P3L to farthest of two
*When + and - wired with75m245'
* MYW-P3L to PS-18C/18E5m
Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of two years
after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which examination
shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision whether there is a
defect in materials and/or workmanship; and whether or not the product is within the warranty.
This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation of
-4*
instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover
batteries or damage caused by batteries used in connection with the product.
This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone.
Aiphone will not be responsible for any costs incurred involving on site service calls.
DC 18V, 0.6A max. 0.15A (standby).
Use a PS-18C or PS-18E power supply for a basic system with two
video monitors.
Three PanTilt door stations.
Two MYH-CU(B)'s, expandable
Door release and auxiliary lights (3 each, selectively controlled).
2 parallel wires per PanTilt door station.
6 wires to video monitors.
5 wires (common) -i- 2 per entry to LEF network
1 .Ommo
75m
35m
WARRANTY
18AWG
245'
115'
16'
•i*
AIPHONE CO., LTD.. Nagoya, Japan
AIPHONE CORPORATION,Bellevue,WA,USA
MYW-P3L-I(E) 0697C
COMMUNICATION SYSTEMS
® AIPHONE
HOME. BUSINESS, INDUSTRY.
Printed in Japan (E)
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.