0113
LEF-5-NE/LEW-5-NE
5-call Master Station
Master Station for use with the NEM and NDR Systems
- INSTRUCTIONS -
The LEF-5-NE is a 5-station master, equipped with a door release button, and able to integrate into a larger
NEM or NDR system. In applications where up to 5 door stations needs to be answered from the main NEM/
NDR master as well as additional small master stations, the LEF-5-NE can be used. The LEW-5-NE adaptor
is required. This system can be used with the following subs: NE-DA, NE-JA, NE-SS/SSR, NE-NVP/C,
NE-NVP-2DC-LE, NE-NVP-RA.
WIRING DIAGRAM: using NE-DA and NE-JA subs
NDR-40
1
2
3
4
5
~
40
E
H
Q
PS-2420UL
+
-
To Door
Strike for
Door #1
To Door
Strike for
Door #4
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
+
-
RY-PA
Diode value:
1N4001 ~ 4007
RY-PA
PS-1225UL
LEF-5-NE
1
BlkYel
K1
2
K2
3
K3
4
K4
5
C
E
BlkYel
R
L
+
-
+
-
LEF-5-NE
1
K1
2
K2
3
K3
4
K4
C
5
E
R
L
+
-
Toll Free Technical Support:
1-800-692-0200
E-mail tech@aiphone.com
LEW-5-NE/B
Adaptor
N1 D1
N2 D2
N3 D3
NE-DA
1
2
Blk
N4 D4
N5 D5
Wire each door
NE
H
Q
L1
K1
L2
K2
L3
K3
L4
Leave jumper
station to a
designated
number station
as shown here.
intact
NE-JA
1
2
3
4
Blk
Grn
K4
L5
K5
LE
RF
NOTE: Standard LE-series sub stations cannot be used
in a system with the LEF-5-NE master stations. The LED
timing circuit in the LEF is modified.
The NA-A and NA-AN also cannot be used to call the
LEF-5-NE, but can be connected directly to the NDR/
NDRM master station.
"K" Terminal connections
are required in this
application, with or without
door release being included.
LEF-5-NE Instr.
Page 1
WIRING DIAGRAM: using NE-SS/SSR and NE-NVP-2DC-LE subs
PS-2420UL
+
-
To Door
Strike for
Door #1
To Door
Strike for
Door #5
NDR-40
1
2
3
4
5
~
40
E
H
Q
+
-
RY-PA
1N4001 ~ 4007
RY-PA
BlkYel
Diode value:
BlkYel
LEF-5-NE
1
K1
2
K2
3
K3
4
K4
5
K5
E
R
L
LEW-5-NE/B
Adaptor
N1 D1
N2 D2
N3 D3
N4 D4
N5 D5
NE
H
Q
L1
K1
NOTE: "K"
L2
Terminal
connections are
K2
required in this
L3
application, with
K3
or without door
release being
L4
included.
K4
L5
K5
LE
RF
NE-SS/SSR
Red
Blk
Wht
Grn
wire
Wire each door
station to a
designated
number station
as shown here.
NE-NVP-2DC-LE
Red
Blk
Wht
Pur
Blu
Grn
wire
Org
Org
Yel
Yel
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
+
-
PS-1225UL
+
-
Toll Free Technical Support:
1-800-692-0200
E-mail tech@aiphone.com