Aiphone LEF-5-NE, LEW-5-NE User Manual

0113
LEF-5-NE/LEW-5-NE
5-call Master Station
Master Station for use with the NEM and NDR Systems
- INSTRUCTIONS -
The LEF-5-NE is a 5-station master, equipped with a door release button, and able to integrate into a larger NEM or NDR system. In applications where up to 5 door stations needs to be answered from the main NEM/ NDR master as well as additional small master stations, the LEF-5-NE can be used. The LEW-5-NE adaptor
is required. This system can be used with the following subs: NE-DA, NE-JA, NE-SS/SSR, NE-NVP/C, NE-NVP-2DC-LE, NE-NVP-RA.
WIRING DIAGRAM: using NE-DA and NE-JA subs
NDR-40
1 2 3 4 5 ~
40
E H Q
PS-2420UL
+
-
To Door
Strike for
Door #1
To Door
Strike for
Door #4
Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005 (425) 455-0510 FAX (425) 455-0071
+
-
RY-PA
Diode value:
1N4001 ~ 4007
RY-PA
PS-1225UL
LEF-5-NE
1
BlkYel
K1
2
K2
3
K3
4
K4
5 C E
BlkYel
R
L
+
-
+
-
LEF-5-NE
1
K1
2
K2
3
K3
4
K4
C
5 E R
L
+
-
Toll Free Technical Support:
1-800-692-0200
E-mail tech@aiphone.com
LEW-5-NE/B
Adaptor
N1 D1 N2 D2 N3 D3
NE-DA
1 2
Blk N4 D4 N5 D5
Wire each door
NE H Q
L1 K1 L2 K2 L3 K3 L4
Leave jumper
station to a designated number station as shown here.
intact
NE-JA
1 2 3 4
Blk
Grn
K4 L5 K5 LE RF
NOTE: Standard LE-series sub stations cannot be used in a system with the LEF-5-NE master stations. The LED timing circuit in the LEF is modified. The NA-A and NA-AN also cannot be used to call the LEF-5-NE, but can be connected directly to the NDR/ NDRM master station.
"K" Terminal connections are required in this application, with or without door release being included.
LEF-5-NE Instr.
Page 1
WIRING DIAGRAM: using NE-SS/SSR and NE-NVP-2DC-LE subs
PS-2420UL
+
-
To Door
Strike for
Door #1
To Door
Strike for
Door #5
NDR-40
1 2 3 4 5
~
40
E H Q
+
-
RY-PA
1N4001 ~ 4007
RY-PA
BlkYel
Diode value:
BlkYel
LEF-5-NE
1
K1
2
K2
3
K3
4
K4
5
K5
E
R
L
LEW-5-NE/B
Adaptor
N1 D1 N2 D2 N3 D3 N4 D4 N5 D5
NE H Q
L1 K1
NOTE: "K"
L2
Terminal connections are
K2
required in this
L3
application, with
K3
or without door release being
L4
included.
K4 L5 K5 LE RF
NE-SS/SSR
Red
Blk
Wht
Grn wire
Wire each door station to a designated number station as shown here.
NE-NVP-2DC-LE
Red
Blk
Wht
Pur Blu
Grn wire
Org Org
Yel Yel
Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005 (425) 455-0510 FAX (425) 455-0071
+
-
PS-1225UL
+
-
Toll Free Technical Support:
1-800-692-0200
E-mail tech@aiphone.com