0113
LEF-5-NE/LEW-5-NE
5-call Master Station
Master Station for use with the NEM and NDR Systems
- INSTRUCTIONS -
The LEF-5-NE is a 5-station master, equipped with a door release button, and able to integrate into a larger
NEM or NDR system. In applications where up to 5 door stations needs to be answered from the main NEM/
NDR master as well as additional small master stations, the LEF-5-NE can be used. The LEW-5-NE adaptor
is required. This system can be used with the following subs: NE-DA, NE-JA, NE-SS/SSR, NE-NVP/C,
NE-NVP-2DC-LE, NE-NVP-RA.
WIRING DIAGRAM: using NE-DA and NE-JA subs
NDR-40
1
2
3
4
5
~
40
E
H
Q
PS-2420UL
+
-
To Door
Strike for
Door #1
To Door
Strike for
Door #4
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
+
-
RY-PA
Diode value:
1N4001 ~ 4007
RY-PA
PS-1225UL
LEF-5-NE
1
BlkYel
K1
2
K2
3
K3
4
K4
5
C
E
BlkYel
R
L
+
-
+
-
LEF-5-NE
1
K1
2
K2
3
K3
4
K4
C
5
E
R
L
+
-
Toll Free Technical Support:
1-800-692-0200
E-mail tech@aiphone.com
LEW-5-NE/B
Adaptor
N1 D1
N2 D2
N3 D3
NE-DA
1
2
Blk
N4 D4
N5 D5
Wire each door
NE
H
Q
L1
K1
L2
K2
L3
K3
L4
Leave jumper
station to a
designated
number station
as shown here.
intact
NE-JA
1
2
3
4
Blk
Grn
K4
L5
K5
LE
RF
NOTE: Standard LE-series sub stations cannot be used
in a system with the LEF-5-NE master stations. The LED
timing circuit in the LEF is modified.
The NA-A and NA-AN also cannot be used to call the
LEF-5-NE, but can be connected directly to the NDR/
NDRM master station.
"K" Terminal connections
are required in this
application, with or without
door release being included.
LEF-5-NE Instr.
Page 1

WIRING DIAGRAM: using NE-SS/SSR and NE-NVP-2DC-LE subs
PS-2420UL
+
-
To Door
Strike for
Door #1
To Door
Strike for
Door #5
NDR-40
1
2
3
4
5
~
40
E
H
Q
+
-
RY-PA
1N4001 ~ 4007
RY-PA
BlkYel
Diode value:
BlkYel
LEF-5-NE
1
K1
2
K2
3
K3
4
K4
5
K5
E
R
L
LEW-5-NE/B
Adaptor
N1 D1
N2 D2
N3 D3
N4 D4
N5 D5
NE
H
Q
L1
K1
NOTE: "K"
L2
Terminal
connections are
K2
required in this
L3
application, with
K3
or without door
release being
L4
included.
K4
L5
K5
LE
RF
NE-SS/SSR
Red
Blk
Wht
Grn
wire
Wire each door
station to a
designated
number station
as shown here.
NE-NVP-2DC-LE
Red
Blk
Wht
Pur
Blu
Grn
wire
Org
Org
Yel
Yel
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
+
-
PS-1225UL
+
-
Toll Free Technical Support:
1-800-692-0200
E-mail tech@aiphone.com
Page 2

WIRING DIAGRAM: using NE-NVP-RA and NE-NVP/C subs
LEW-5-NE/B
NDR-20A-RS
Adaptor
NE-NVP-RA
PS-2420UL
To Door
Strike for
Door #1
To Door
Strike for
Door #5
1
2
3
4
5
~
N1 D1
N2 D2
N3 D3
N4 D4
N5 D5
Red
Blk
Gray
Grn
wire
20
E
H
Q
NE
H
Q
S
+
-
+
-
RY-PA
RY-PA
1N4001 ~ 4007
BlkYel
BlkYel
Diode value:
LEF-5-NE
1
K1
2
K2
3
K3
4
K4
5
K5
E
R
L1
K1
NOTE: "K"
L2
Terminal
connections are
K2
required in this
L3
application, with
K3
or without door
release being
L4
included.
K4
L5
K5
LE
RF
NAR-2A*
Blue
Blue
Blue
Pur
Org
Yel
* Reset Button:
(Any normally closed
button or keyswitch.
Not required when
using the NEM-RS
master.)
NE-NVP/C
Red
Blk
Wht
L
Wire each
+
-
+
-
station to a
designated
number station
as shown here.
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
PS-1225UL
Toll Free Technical Support:
1-800-692-0200
E-mail tech@aiphone.com
Page 3

WIRING DIAGRAM: with no NEM or NDR master being used
LEF-5-NE
1
K1
2
3
4
5
C
E
R
L
PS-1225UL
-
+
LEF-5-NE
1
K1
2
3
4
C
5
E
R
L
LEW-5-NE/B
Adaptor
N1 D1
N2 D2
N3 D3
N4 D4
N5 D5
NE
H
Q
L1
K1
L2
K2
L3
K3
L4
K4
L5
K5
LE
RF
NE-NVP-2DC-LE
Red
Blk
Wht
Pur
Blu
Grn
wire
Org
Org
Yel
Yel
Connect with wires
of the standard call button
to activate a call when the
RED button is pressed.
+
-
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
+
-
PS-1225UL
+
-
Toll Free Technical Support:
1-800-692-0200
E-mail tech@aiphone.com
Page 4

OPERATION:
1. Pressing the call button at the door/sub station will activate the call tone, plus light the
appropriate station LED at the NEM/NDR master. The call tone will be heard at the LEF-5-NE
master(s) continually until the call is answered from any master in the system.
2. To answer the call on the LEF or NEM/NDR master, press the station button corresponding to
the lit LED, then press TALK to speak to the visitor. When the first master answers the call,
the Occupied lamp will be lit on all other masters. DO NOT answer the call if the Occupied
lamp is lit.
3. Communication at the master station is "press-to-talk, release-to-listen". Communication at
the door station is hands free.
4. With communication established to the door station, pressing the door release button will
activate the door release mechanism at the corresponding door.
5. When the call is completed, press OFF on the LEF master, or the associated black OFF
button on the NEM/NDR master. The Occupied lamp will go out on all masters when the call
is cancelled.
SPECIFICATIONS:
Power Source: 12V DC at master. Use PS-1225UL.
Communication Output: 800mW @ 20 ohms (receive); 500mW @ 20 ohms (transmit)
Communication: Push-to-talk, release-to-listen at master station.
Hands free at sub station.
Calling: Master to sub: By voice
Sub to master: Mono-electronic call tone
Compatible Remotes: NE-DA, NE-JA, NE-SS/SSR, NE-NVP/C, NE-NVP-2DC-LE,
NE-NVP-RA
Wiring: 3 conductors from door/sub to LEW-5/NE Adaptor (Aiphone #822203)
2 common plus 2 individual conductors per door from
LEW-5-NE to LEF-5-NE (Max. 12 conductors with 5 door stns)
(Aiphone #822212)
7 conductors from LEW-NE to NEM/NDR master (Aiphone #822212)
2 conductors from master to their respective power supply.
Shielded cable is recommended.
Wiring Distance: 420' with 22AWG; 1,000' with 18AWG.
Dimensions (H x W x D): 7" x 5-1/2" x 2-1/4" (dimensions are for the LEW-5-NE)
Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA 98005
(425) 455-0510
FAX (425) 455-0071
Toll Free Technical Support:
1-800-692-0200
E-mail tech@aiphone.com
LEF-5-NE Instr.
Page 5
0113PH