The LAF-C Console Master system is a loudspeaker type, single talkpath open voice system. Multiple masters can be used, along with a large variety of sub station models to create a communication system tailored to the user's needs. Master stations are available in 20-and 40-station sizes, with or without a handset. For greater capacity, include a 20- or 40-station add-on selector. Any "LE-" or "LS-" series sub station can be used. All Call and/or Background Music are optional features requiring additional equipment (BG-10C, PS-1225UL).
LAF-20CA (pictured)
FEATURES:
· Single or multi-master capability
· Commercial grade, durable master station for heavier usage
· Master stations available with or without a handset
· Single talkpath, with push-to-talk operation or handset at master, and hands free communication at sub station
· Large variety of sub stations available
- Surface or flush mount, with or without privacy (LE-A, LE-AN, LE-B, LE-BN)
- Weather resistant door stations (LE-D, LE-DA, LE-DL)
- Vandal proof sub station (LS-NVP/B, SBX-NVP surface mount box)
· Selective calling to sub stations, and master-to-master communication
· Subs call in with momentary tone and LED, remaining lit for approximately 20 seconds
· Optional All Call (additional equipment required) to call all stations simultaneously
· Equipment used for All Call also allows for background music to be heard through master and subs
· Master is desk or wall mountable. LAF-20CA can be rack mounted in RMK-01 rack mount kit. LAF-20C can be rack mounted in RMK-03 rack mount kit.
· 20- and 40-call add-on selectors available, with LA-40AS rack mountable with RMK-02.
NAMES & FUNCTIONS:
1. Handset
2. Power indicator
3. Microphone
4. Speaker
5. Terminal Block
6. OFF button
7. Selector button
8. Power switch
9. Voice volume control
10. Call tone volume control
11. All Call button
12. TALK button
13. Occupied LED
14. OFF LED
15. Directory card
16. Station selector LED
Pg. 1
COMPONENTS & WIRING
Individual Components for System:
LAF-20C 20-call console-style master station LAF-20CA 20-call console-style master station with handset LAF-40C 40-call console-style master station LAF-40CA 40-call console-style master station with handset LA-20AS 20-call Add-on Selector LA-40AS 40-call Add-on Selector PS-1225UL 12V DC, 2.5A Power Supply. One per system, or
one per BG-10C when All Call/Music is included
(also powers intercom system) LE-series Any sub station with "LE-" prefix LS-NVP/B Vandal proof sub station for LAF-C/CA system SBX-NVP Surface mount box for LS-NVP SA-1 Surge Arrestor (1 per 2 wires being protected)
LAF-20C/CA terminal block
X4X3X2X1EEEE-+
X8X7X6X5P3P2P1YRC
LAF-C TERMINAL DEFINITIONS:
+ Positive 12V DC
- Negative
12345678910
11121314151617181920
1~40 Station number, establishes communication to other master or sub C "CALL", for receiving a call from another master E Common communication R Control for Occupied light
("R" is grounded when system is occupied)
Y All Call override control of station in use during All Call
(9V DC when system is in All Call mode)
P1 All Call activation control
(10V DC when All Call is activated)
P2, P3 Audio output for All Call initiation
(Voice transmit from master initiating All Call)
X1~X8 Connection for add-on selector (Type E)
Remove X2/X3 jumper when add-on selector is used.
JUMPERS:
In multi-master system, remove E/- jumper at master and sub stations. When add-on selector is included, remove X2/X3 jumper.
INTERNAL CONTROLS:
VOX. SENSITIVITY: Potentiometer is located inside unit behind handset. Adjust for sensitivity of VOX circuit.
CALL TONE WHILE MONITORING:
On the main PC board, there is a jumper labeled W1. With this in place, the incoming call tone will be muted if any master in the system is in the Occupied mode. If call tone is desired while Occupied, cut W1 jumper.
TRANSMIT RECEIVE
WIRING & INSTALLATION: Before Installation:
· Make sure you have the proper power supply(ies) and all necessary and compatible equipment for the system.
· All Call and/or background music are optional features which require additional equipment. See notes below.
· Lay out your system in advance, assigning station numbers for all sub station locations.
· Surge protection for the intercom equipment is strongly recommended. Add SA-1 surge arrestors for the power
supply, plus one per two wires connected to the master station. See diagram on page 3.
Wire:
· Shielded wire is recommended. Use the proper gauge for the distance being run.
· Wiring between masters must be a multi-conductor cable. If more than one cable is used to connect masters,
the "E", "C", and number terminal wires must be in the same jacketed cable. If necessary, run multiple "E" wires, one in each cable.
Wiring Method:
· Run intercom cables at least 20" away from all AC wiring, fluorescent lights, dimmer switches, and other
electrical or electronic devices. Wiring can cross AC wires at 90 degrees.
· Sub stations may be homerun to the nearest master station, or daisy-chained. If daisy-chained, include 2
common wires plus one individual wire per station on the run.
· In a SINGLE MASTER SYSTEM ONLY: Subs can be wired with 2 conductors homerun. Jumpers between "E"
and "-" must be attached on all subs and at the master.
Intercom Locations:
· Do not install intercoms near dimmer or light switches, or other electrical wall devices.
· To prevent feedback, do not place sub stations back-to-back on a common wall.
All Call and Background Music:
· The BG-10C adaptor and PS-1225UL power supply are required for each group of 11 stations to receive All Call
and music. This equipment should be installed in an equipment room or in a cabinet. Capacitors (NP-25V) are required for each sub station on the system. See wiring diagram on page 5 for installation information.
Pg. 2
WIRING DIAGRAMS
3a. SINGLE MASTER SYSTEM, NO ALL CALL
SA-
1
SA-1 for optional surge protection (See note #3.)
SA-
1
LAF-20C
1 2 3 4 5
~
20
E E E E
­C R Y
P1 P2 P3
+
-
All "E" terminals are
common internally.
SA-
1
PS-1225UL
LE-A
1
LE-A
1
LE-D
1
E
-
E
-
E
-
LE-D
1
E
-
NOTES: Two wiring method can be used:
1. 2 conductor homerun to each sub station from the master. (Single master system only.)
2. Run multi-conductor wire in a daisy-chained fashion with 2 common wires (E & -) plus one individual wire per station on the run.
+
Remove jumpers between E & - when daisy-chained method is used.
-
3. To protect system from power surge, install SA-1 arrestors at master station. One SA-1 is required for every two wires connected to master.
3b. DUAL MASTER SYSTEM WITH MASTER-TO-MASTER COMMUNICATION
LAF-20CA
1 2 3
~
19
E
-
20
C R
Y P1 P2 P3
+
-
LAF-20CA
1 2 3
~
19
E
-
C
20
R
Y P1 P2 P3
+
-
Remove E/- jumpers
Master-to-master communication is shown on channel 20 of each master.
Y, P1, P2, P3 terminals used only if All Call Adaptors are included.
+
-
PS-1225UL
LE-DA
1
E
-
LE-DA
1
E
-
LE-DA
1
E
-
WIRING NOTE:
The following sub stations are wired as shown above:
· LE-A, LE-AN
· LE-B, LE-BN
· LE-D, LE-DA
LE-DA
1
E
-
Blk
Red Wht
RY-AC
RY-AC for external signalling when sub calls
Yellow
To external signalling device and power (E.g. Station #19 will actvate ext. device when it calls in to master.)
Pg. 3
Loading...
+ 5 hidden pages