Simultaneous communication system for 1 each door station, room station and door release.
Can be powered by a single bell transformer for both communication and door release.
May be combined with MC-D/MC-U Video Intercom System (hanging up handset shuts off video monitor).
Melodic 4-stroke chime with volume control.
Call extension device to announce a chime call from any door in a place remote from room station.
Select a most suitable door station from IC-series door stations.
SPECIFICATIONS
* Power source: IC-IAD(U); May be powered by a bell transformer AC 12-16V, 135 mA or more OR a power
supply DC12-24V, 150 mA or more.
* Current consumption: 135 mA maximum (AC12-16V). 150 mA maximum (DC12-24V).
* Wiring and communication distance: Single pair of wires.
Select the proper wire gauge to meet your requirements from the chart below:
Diameter of wires0.5 mm0.65 mm0.8 mm
Distance90 m150 m230 m
Door release:
Use a door release EL-9S (AC 12V, 250 mA) or of other manufacture, which does not exceed AC 12-16V,
1.0 mm
360 m
AWG
24 AWG
Distance300'
22 AWG 20 AWG 18 AWG
500'750'
500 mA when powered by a system’s bell transformer.
Bell transformer for both communication and door release:
AC12-16V, 450 mA or more (for EL-9S). AC12-16V, 700 mA or more (for other manufacture’s).
(inch)
1,180'
BEFORE YOU INSTALL AND OPERATE THE EQUIPMENT - Prohibitions and precautions -
* Operation;
1. DO NOT HOLD HOOK SWITCH DOWN WHILE PICKING UP HANDSET. THE CHIME
TONE SOUNDS THRU THE HANDSET RECEIVER ELEMENT AND COULD CAUSE
HEARING DAMAGE.
NEVER
* Installation;
1. DO NOT CONNECT ANY TERMINAL ON ANY UNIT TO AC POWER LINES.
When you mount IC-1 AD(U) in place of existing bell or chime, be sure to disconnect wires
from the present transformer.
2. Be sure to disconnect wires from bell transformer (or power supply) before you open the
IC-IAD(U) unit or make wiring connections.
3. Avoid running the connecting wires thru doors, windows or between furniture, which
may pinch and disconnect the wires.
NEVER
4. IC-IAD(U) equipment must be installed in as dry and dust-free environment as possible.
Maintenance;
1. Clean your IC-IAD(U) equipment with a soft cloth dampened with neutral household
cleanser. Never use thinner nor benzine, etc.
2. Do not splash water on the door station by hose, etc.
- 1 -
Page 2
SYSTEM LAYOUT
COMPONENTS AVAILABLE
* Door stations: Select either type from the 1C series door stations;
w/anodized aluminum cover.
Surface-mount.
(IC-DL type: with illumina-
IC-D3, -DL3 tion lamp)
Options;
EL-9S: Electric door release.
AC 12 V, 250mA. May be
powered by a system’s bell
transformer (one per system).
■
ICR-1: Call extension.
Announces a call from door by
chime in a place remote from
IC-IAD(U) (one per system).
NOTES:
Your lC-1 AD(U) unit can also work with the existing models; IB-DA, IB-NA, IB-RA, IB-RAG, IB-JA, IB-FY and IBR-l/A.
ACTUAL TERMINAL LOCATION
IC-1AD(U)BACK VIEW
For power supply.
Connect to QH , [2] terminals
on door station (non-polarized)
Connect to electric door release
(non-polarized)
For call extension
(non-polarized)
CASE & CHASSIS
INSIDE VIEW
PC BOARD
(1) Remove 2 screws on back of the chassis and separate front case and chassis.
(2) As shown, take out two WHITE wires thru a hole on the chassis.
(3) Connect 2 wires to the wires from the ICR-1 (non-polarized).
Page 3
WALL MOUNTING INSTALLATION
Attaché’^ the mounting bracket to wall or one-gang box
with the supplied screws. Insert the prongs of the
bracket into the holes of the body and pull the body
downward.
Be careful not to attach the bracket upside down.
WIRING DIAGRAM
ROOM STATION
IC-IAD(U)
IC-IAD(U)
power supply.
NOTES:
(1) Door station;
(2) Door release; As shown in the above diagram, EL-9S can be powered by a system bell transformer.
(3) Call extension; Wiring is non-polarized. Extend one pair of wires from ICR-1 and connect each to either WHITE wire
(4) Bell transformer; It is suggested that the bell transformer should be located close to the IC-IAD(U) station.
Wiring is non-polarized. Connect either terminal [T] or on IC-IAD(U) to either terminal [T] or
I2I on door station.
on IC-IAD(U).
Connect either output wire on bell transformer ACl 2-16V to either terminal or [2^ onlC-lAD(U).
Note. When using a power supply (DC12-24V), observe polarity carefully.
Page 4
OPERATIONS
Room station;
1. Communication;
At door station:
Momentarilly depress CALL button. After room station replies, talk handsfree.
At room station:
Incoming call is announced by 4-stroke chime at IC-1 AD(U) and ICR-1, if installed.
To reply, simply pick up handset at IC-IAD(U).
After communication, hang up handset onto its cradle properly.
2. To operate door release:
While you hold your handset, depress and hold door release button on IC-1 AD(U),
The visitor may open the door while buzzing sound is heard.
HIGH
MEDIUM
3. Adjusting chime volume:
Adjust chime call volume to 3 levels as desired by the switch on IC-IAD(U),
while chime call volume at ICR-1 remains unchanged.
WARRANTY
Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of one
year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which
examination shall disclose to be defective and under warranty.. Aiphone reserves unto itself the sole right to make the final decision
whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty.
This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation of
instructions furnished, nor extended to units which have been repaired or altered outside of the factory.
This warranty does not cover batteries or damage caused by batteries used in connection with the product.
This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone. Aiphone
will not be responsible for any costs incurred involving on site service calls.