Before actually installing CCS-1 A, the contents of this Manuai
must be thoroughly read and understood.
A PRECAUTIONS ON INSTALLATION & WIRING
WARNING
(Negligence could result in death or serious
injury to people)
A: GENERAL PRECAUTIONS
(^: General prohibitions.
0): Prohibitions to subject the unit to water.
CAUTION
A
(Negligence could result in injury to people or
damage to property)
Prohibitions to dismantle the unit.
®
A
WARNING
1. Do not change or modify CC-1M equipment.
2. Do not connect any power source other than specified to
WHITE wires on CC-1 M. Doing so can cause fire or
damage the unit. Q
3. If an AC transformer rated more than 20V no-load voltage, is
connected, it can damage the CC-1 M units or cause fire.
Aiphone is not responsible for any loss or damage incurred.
4. The CC-1 M Muipment must not be exposed to water or any
other liquid.
5. Do not open CC-1 M equipment. Doing so can cause fire or
damage the unit. ^
6. Make sure wires are connected properly before plugging in
the power supply.
7. Keep AC outlet away from moisture and dust.
CAUTION
A
1. Do not install or make any wire terminations while power
supply is turned on. It can cause electrical shock or
damage the unit.
2. Mount the CC-1 M & CC-DA on wail in a convenient
location, but not where it could be bumped or jarred.
3. Do not install CC-1 M equipment in any of the
following locations, as it may cause the system to
malfunction;
High or extreme cold temperature area: under direct
sunlight, near equipment that varies in temperature,
in front of air-conditioner, inside a refrigerated area,
etc.
Places subject to moisture or humidity extremes.
Places subject to environmental conditions, such as
oil, dust, chemicals, salt, etc. (§)
Places subject to constant vibration or impact.
GENERAL PRECAUTIONS
A
1.
CC-1M equipment, except for CC-DA, is designed for
indoor use only. Do not install outdoors.
2.
CC-1M system is not operable during a power failure.
In areas where broadcasting station antennas are close
3.
by, intercom system may be affected by radio frequency
interference.
Keep all DC wiring at least 30cm (1') away from
4.
AC 100 ~ 240V wiring, fluorescent lighting, or dimmer
switches. Otherwise, cross AC wiring at a 90° angle.
#90115
- 1
SYSTEM OUTLINE & COMPONENTS
CCS-1A “Chime Com 2” is a set with a door station & an inside room station, powered by an AC transformer. Second room
station CC-1M can be added with a separate AC transformer.
*1 CC-DA2
li
IJi
I
CZD
IIIIUIII
ADDITION
CC-1M
Package Contents
CCS-1 A ‘CC-1 M
• CC-DA
• Packet of screws
• installation & Operation manual
CC-IM *CC-1M
• Packet of screws
• Installation & Operation manual
■ Components available
CCS-1 A: Set of CC-DA door station & CC-1M inside room station.
CC-1M: Second room station.
1^: AC transformer. PT-1210N or 12-16V AC, 10VA (with no-load voltage ratings: 20V or less).
/4\ WARNING: - If an AC transformer rated more than 20V no-load voltage, is connected,
DANGER it can damage the CC-1 M units or cause fire. Aiphone is not responsible for any loss or
damage incurred.
NAMES & FEATURES
CC-1M
CC-DA
Speaker/Mic
Illuminator
Call button
Mounting screw
-J— holes
I Features
Press-to-talk door answering with auto shut off timer
2-tone electronic chime call-in
Second inside room station. (Separate power supply required)
Backlit CALL button
CHIME and VOICE volume controls
-2
I INSTALLATION & WIRING
When replacing an existing doorbell:
Check to see how the existing doorbell Is wired.
DIAGRAMS: Existing Doorbell, method 1
DOOR BELL
B
Method 1:
If there are only two matching colored wires located at the existing inside bell, the AC
transformer was likely wired in series with the bell and button. If so, take the wires off of
the AC transformer and splice them together, making a continuous wire to the bell.
Measure the AC voltage with a volt meter. However, Aiphone is not responsible for any
damage caused by power surge. Two additional wires must be run from the transformer
to the location where the CC-1M room station will be installed. The two wires from the
doorbell button must be connected to the RED/BROWN wires of the CC-1M, with NO AC
voltage on the wires. Two wires from the AC transformer connect to the WHITE wires of
the CC-1M room station. Remove the doorbell button outside and reconnect the two wires
to the RED/BROWN wires on the CC-DA. Mount CC-DA to wall.
Splice together
Red
Brown
White
White
■ When replacing an existing doorbell:
Existing Doorbell, method 2 or New Installation:
B
, Method 2:
Spliced
together
Red
Brown
White-
White-
AC trans
If there are two matching colored wires connected to the bell, and two(or more)
additional matching colored wires spliced together but not connected to the bell, then
there are likely enough wires to connect the Chime Com 2 without running new wire.
1. Take wires off of bell, and separate the wires that are spliced together.
2. Locate the bell transformer currently installed, disconnect it from the existing bell, and
measure the AC voltage with a volt meter. However Aiphone is not responsible for
any damage caused by power surge. Connect the pair from the AC transoformer to
the WHITE wires on the CC-1 M. Connect the other pair of wires (which go to the
door) to the RED/BROWN wires on the CC-1M.
3. Outside, remove the doorbell button, and connect the two wires to the CC-DA door
station, then mount on the wall.
NOTE: When the inside room station is to be installed in a different location, splice
wires from the existing doorbell location and run new wire to the desired location
for the new room station. Either leave the existing doorbell on the wall but
disconnected, or remove it and patch the wall as needed.
How to measure AC no-load voltage
Primary input
Power supply
Second room station
Turn off circuit breaker powering AC transformer, and disconnect secondary output
wires. Turn circuit breaker back on, and measure secondary output terminals with a
volt meter. If the reading is between 12-20V, it can be used to power the CC-1M.
If you cannot safely perform this function, or if the transformer does not meet the
specification, install a standard AC outlet and use the Aiphone PT-1210N plug-in
transformer.
The power source for the CC-1M must meet the following specifications:
• AC no-load voltage: Min. 12V, Max. 20V.
• UL LISTED and Class 2 rated or marked.
• Ratings: 12-16V AC, 10VA or more.
Another CC-1M station can be added to the system. It requires a separate power
supply, and is to be wired (polarized) from the first inside station (not the door).
WIRING DIAGRAM
MOUNTING
CC-DA mounts on surface of wall with 2 screws.
CC-DA
TECHNICAL PRECAUTIONS
-------------------
• CCS-1A components are not compatible with C-123L/A units.
• In 2-CC-1M system;
1. There is no calling between CC-1 M stations.
2. If both CC-1 M's press the TALK button (meaning both
masters are on), a squeal will be heard when either CC-1 M
presses the TALK button. Wait until system turns itself off
before using.
• To prevent acoustic feedback;
Do not mount a door station & a room station back to back on
a common wall. With conduit wiring, pack conduit with foam or
insulation for best results.
• CC-DA is weather resistant. If possible and for best results,
install the door station in an area not directly exposed to
weather.
• Do not apply caulking or sealant around door station, so the
openings allow moisture to dissipate.
• Do not put direct pressure water on CC-DA door station.
• Clean CC-1M unit with a soft cloth dampened with neutral
household cleanser. Never use any abrasive cleaner or cloth.
(101.5mm)
2 wood screws supplied
SINGLE-GANG BOX or WALL
CC-1M
1. Attach the mounting bracket to box or wall.
2 screws supplied
OPERATIONS
2. Mount the CC-1M station on the bracket.
--------------------------------------
At CC-DA door, press CALL button (backlit) once. A muted
chime will be heard at the door. At CC-1 M room station(s), 2tone chime sounds. Press TALK button to transmit, and release
to listen. The system automatically turns off in 15 seconds after
last time the TALK button is pressed. Press TALK button to
recycle.
• Chime & voice volume adjustments:
4^ SPECIFICATIONS (CC-1M)
--------------------
• Power source: 12-16V AC, 10VA.
• Power supply: AC transformer PT-1210N in USA (specified)
or 12-16V 10VA AC (with no-load voltage
rating: 20V or less).
• Communication: 2-tone chime call-in.
Press “TALK” button on room station to talk,
release to listen. Hands free at door. 15 sec.
time out after last time TALK button released.
•Controls: CHIME vol. VOICE vol.
• Wiring: 2 parallel wires, non-polarized to door.
2 wires to another room, polarized.
2 wires to PT-1210N (from ea. CC-1 M)
Distance:
18AWG(1.Omm0)
CC-DA to CC-1M (or 2nd)
CC-1 M to AC transformer
22AWG(O.65mm0)
245’(75m)590'(180m)
65’(20m)145'(45m)
• Dimensions & weight:
CC-1M: 7"H X 4-3/4”W x 1-5/16”D. 180H x 123W x 33D (mm). 400g (0.88lbs.).
CC-DA: 4-1/2”H x 2-3/4”W x 1-3/16”D. 114H x 70W x 30D (mm). 150g (0.33lbs.)
CHIME VOICE
CC-1 M bottom view
<
^ WARRANTY
Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of one
year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which
examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision
whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty.
This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation of
instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover
batteries or damage caused by batteries used in connection with the product.
This warranty covers bench repairs only, and any repairs must be made at the shop or place designated In writing by Aiphone.
Aiphone will not be responsible for any costs incurred involving on site service calls.
L H
». 4
Aiphone Co., Ltd., Nagoya, Japan
Aiphone Corporation, Bellevue, WA, USA
CCS-IA-I(E) 0697B
#90115
-4
•«
V- «1« 4
COMMUNICATION SYSTEMS
AIPHONE
o
HOME, BUSINESS, INDUSTRY.
Printed In Hong Kong (E)
♦1-
♦i*
-I-
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.