90102 0610
C-123LW Supplemental Instructions
Dual Master ChimeCom System
- REFER TO INSTALLATION MANUAL INSIDE C-123L/A BOX FOR STANDARD
INSTALLATION INFORMATION -
The C-123LW Dual Master ChimeCom set provides chime, communication, and door release for one door and two
inside locations. This supplemental instruction manual addresses many of the additional functions and modifi cations
for the Chime Com system, including installation and troubleshooting information.
MASTER STATION:
C-ML/A: Master station with door release button (Normally Open)
COMPATIBLE DOOR STATIONS:
C-D Surface mount, included in C-123L/A and C-123LW kit
LE-D Surface mount, plastic door station (replacement for C-D)
LE-DA Flush mount in 2-gang box, stainless steel cover
LE-SS-1G Vandal resistant, 1-gang fl ush mount, stainless steel
LE-SS Vandal resistant, 2-gang fl ush mount, stainless steel
LE-SSR Vandal resistant, 2-gang fl ush mount, stainless steel, red mushroom button
LS-NVP/C Vandal resistant, 3-gang fl ush mount, white powder-coat fi nish
(Weather resistant, made for outdoor use)
OPTIONAL COMPONENTS & ACCESSORIES:
RY-AC/A External signaling relay (Requires 12VDC power supply)
DAK-2S Dual master adaptor kit (2component modules)
(1 kit per 2 master stations. Use 2 DAK-2S for up to 4 total master stations)
SBX-1G Surface mount box for LE-SS-1G
SBX-2G Surface mount box for LE-SS, LE-SSR, LE-DA
SBX-NVP Surface mount box for LS-NVP/C
EL-12S Door strike (for interior wood frame doors only)
PT-1210N AC 12V Transformer (used for door strike)
SKK-620B 6V DC power supply (1 per C-ML/A master)
822202 2 conductor, 22AWG, Shielded wire for up to 245’, (500’ and 1000’ boxes)
821802 2 conductor, 18AWG, Shielded wire for up to 590’, (1000’ box)
Install two separate runs of this cable, one for the intercom and one for
the door release.
C-123L/A Set
LE-SS-1G LE-DA
LE-SS
LS-NVP/C
DAK-2S
(2 component modules per kit)
DOOR RELEASE WIRES MUST BE IN A SEPARATELY JACKETED CABLE FROM THE INTERCOM WIRING.
C-D
C-123LW Set contains:
2 C-ML/A, 1 C-D, 1 DAK-2S
C-ML/A
Power source and Door Strike not included.
2 cond. shielded for intercom
SKK-620B
IMPORTANT: Connect wires
before applying power.
(or 4 “C” batteries installed in
the master). Do not use both
power sources. Ground wire
must be tied to earth ground
when using the SKK-620B.
Separate 2 conductor for door release
EL-12S, not included with the C-123L/A or C-123LW set.
Power
Source
for Strike
C-123LW Supplement
Pg. 1
WIRING DIAGRAM: Dual Master Chime Com System with DAK-2S Dual Master Adaptor
C-D
1
E
EL-12S
IMPORTANT: Connect wires
before applying power.
* Install bare wire end to the “1” terminal
(DAK-2S contains two component modules)
C-ML/A
1
Component
Module*
E
+
Please read and understand all
instructions before installation.
SKK-620B
Component
Module*
SKK-620B
L
L
IMPORTANT!!!
Each master REQUIRES an SKK-620 power supply, or 4 “C” batteries. (Do not install both on one C-ML/A.)
OPERATION NOTES:
1. Only one master can be used at a time.
2. If both masters are activated, a feedback (squeal) will be heard through the system when either TALK button is pressed.
3. If feedback occurs, wait approximately 15 seconds, or until the masters turns off automatically. At that time,
communication can continue normally.
C-ML/A
1
E
+
L
L
INSTALLATION GUIDELINES:
1. Run 2 conductor wire from the door station to the fi rst master, then continue to the second master.
2. Install the units at the desired locations. (Do not install stations back to back on opposite sides of a wall.)
3. Separate SKK-620 power supplies or four “C” batteries are required for each master station.
4. DO NOT install both a power supply and batteries at any one master.
5. Install the bare wire leg of the component module directly onto the “1” terminal of the C-ML/A’s.
6. Attach the wire coming from the “1” terminal of the C-D to the colored wire end of the component modules at both masters. (The component
modules will easily fi t inside the space available.)
7. Connect the “E” terminals between the door station and master stations.
8. If door release is included, use a separate 2-conductor wire from the “L” terminals of the masters through an AC transformer and to the door strike.
9. The EL-12S is designed for a standard wood framed door, and for light to medium usage. If a different type of door is in place, install a strike
appropriate for the door.
10. The door release button on the master station is a “Normally Open” contact closure for an electric strike. See page 3 for modifi cation to “Normally
Closed” if a magnetic lock is used.
4 C-ML/A Master Stations with 1 Door
C-D
1
Component
Module
E
C-ML/A C-ML/A
1
E
1
Component
Module
E
Note: In a multi-master system, all masters only talk to the
door station, and only one master can be on at a time
C-ML/A
1
E
Component
Module
C-ML/A
1
Component
Module
E
SKK-620B
C-123LW Supplement
Pg. 2
SKK-620B
+
-
+
-
SKK-620B
+
-
SKK-620B
+
-