Aiphone AXW-AVT, AXW-AVR User Manual

0311
AX Series Audio-Video Adaptor for 3rdParty Transmission Equipment
- INSTRUCTIONS -
The AXW-AVT and AXW-AVR are designed to allow connection of a standard AX-series audio video door station (or audio-only IE-series door station) via the AXW-AVT, conditioning the signal for use with 3
rd
party transmission equipment (fiber optics, Ethernet, etc.) and converting it back via the AXW-AVR to a signal compatible with the AX-series exchange unit. External video input/output is provided at both adaptors to allow 3
party camera input, output to recording devices, etc. A motion detector or other activation device can be connected to the Sensor input to trigger door / camera activation (AXW-AVT only). The units also feature a relay output to trigger an external device, such as a DVR or video switcher local to either the AXW­AVT or AXW-AVR whenever the audio and/or video is active. Alternatively, the AXW-AVT can be used to adapt an AX-series audio video door station to a standalone third party device (video server, network DVR, etc).
AXW-AVT
OUT IN
VIDEO
CCTV DOOR
DOOR
AUDIO
IN OUT
+ -
+ - + -
IN
+ -
CALL
+ -
SENSOR
NC NC
RELAY
NO NO
24VOUT
AXW-AVT
AXW-AVT TERMINAL DEFINITIONS:
DOOR (RJ-45 Jack): RJ-45 connection from AX-series audio video door, or spliced audio only door (IE/
IF-series).
AUDIO IN/OUT: Input / Output connections for audio transmission (line level, polarity indicated by
‘+’ and ‘-’).
CALL IN/OUT: Transistor-switched input / output to be connected to relay input / output on
transmission equipment. ‘Call In’ indicates call placed by door station, ‘Call Out’ indicates master-initiated activity (polarity indicated by ‘+’ and ‘-’).
SENSOR NC, NC: Normally Closed contact input, activates ‘Call In’ function when tripped by external
motion detector or other device with N/C contacts. RELAY NO, NO: Normally Open relay contact, activated whenever communication is active. VIDEO IN: Composite input signal from CCTV camera, if used in place of AX-series audio
video door station. VIDEO OUT: Composite output to external transmission equipment. Source dependent upon
CCTV / DOOR switch. CCTV / DOOR SWITCH: Determines whether AX-series audio/video door station video (‘DOOR’ setting) or
external CCTV video (‘CCTV’ setting) will be present on ‘VIDEO OUT’ for
connection to external transmission equipment. 24V +, - 24V DC input (use Aiphone PS-2420UL).
Pg. 1
AXW-AVR
OUT IN
RELAY
NO NO
OUT
+ -
CALL
IN
+ -
+ -
AUDIO
INOUT
+ -
CEU
75 OHM
VIDEO
OFF ON
AXW-AVR
AXW-AVR TERMINAL DEFINITIONS:
RELAY NO, NO: Normally Open relay contact, activated whenever communication is active. CALL IN/OUT: Transistor-switched input / output to be connected to relay input / output on
transmission equipment. ‘Call In’ indicates call placed by door station, ‘Call Out’ indicates master-initiated activity (polarity of input / output indicated by ‘+’ and ‘-’).
AUDIO IN/OUT: Input / Output connections for audio transmission (line level, polarity indicated by
‘+’ and ‘-’).
VIDEO IN: Composite input signal from CCTV camera, if used in place of AX-series audio
video door station.
VIDEO OUT: Composite output to external transmission equipment. Source dependent upon
CCTV / DOOR switch.
OFF/ON SWITCH: Determines whether AX-series audio video door station video (‘DOOR’ setting) or
external CCTV video (‘CCTV’ setting) will be present on ‘VIDEO OUT’ for connection to external transmission equipment.
CEU (RJ-45 Jack): RJ-45 connection from AXW-AVR to CEU, simulating a standard AX-series Audio/
Video door station.
COMPATIBLE DOOR STATIONS (AXW-AVT):
AX-DV Surface mount, die cast zinc, vandal resistant, Audio-Video AX-DVF Flush mount, stainless steel, vandal resistant, Audio-Video AX-DM Mullion mount, black plastic, Audio Only IF-DA Surface mount, brown plastic, Audio Only IE-DC Surface mount, brown plastic w/aluminum, Audio Only IE-JA Flush mount, 2 gang, stainless steel faceplate, Audio Only IE-SS Flush mount, 2-gang, stainless steel, vandal resistant, Audio Only IE-SSR Flush mount, 2-gang, stainless steel, vandal resistant w/red mushroom call button, Audio Only
PROGRAMMING:
1. Follow standard AX programming procedures as described in the AX Installation & Operation manual (included on CD with the AX CEU).
2. When configuring door stations, be sure to set the station number corresponding to the AXW-AVT / ­AVR to “Video” in the AX setup utility.
Typical configuration selection
Pg. 2
CONFIGURATION DIAGRAM: AXW-AVT / AXW-AVR with Meridian Technology Fiber (ST/SR-AiphoneAX1-XS), 1 of 2
AX-DM or IE/IF-Series
Audio Door Station
CCTV Camera 75 Ohm, 1V Peak-to-peak (Independently powered)
*
AXW-AVT
24V
+
-
RELAY
NO NO
SENSOR
NC NC
CALL IN
+
-
CALL OUT
+
-
AUDIO IN
+
-
AUDIO OUT
+
-
DOOR
PS-2420UL
+
-
Normally Open contact for remote device activation
(i.e. video switcher, DVR, etc.)
Normally Closed input for remote activation
(i.e. motion sensor, loop detector, etc.)
AX-DV
CAT-5e
Coax
Configuration Notes (1 of 2):
1. AX-series video door station connects to ‘DOOR’ input of AXW-AVT.
Ensure that the “CCTV / DOOR’ switch on the AXW-AVT is in the ‘DOOR’ position.
*2. Alternatively, an IE/IF-series or AX-DM audio door may be used, along
with 3
rd
party CCTV camera. Connect audio door station to ‘Door’ input (following the wiring method shown in the AX-series installation manual, pg. 12). Connect the camera to ‘Video In’ and put the ‘CCTV / DOOR’ switch in the ‘CCTV’ position.
3. Connect the Call In / Call Out and Audio In / Audio Out connections on the AXW-AVT to the Meridian fiber transmitter module (as detailed at right, Fig. 1). For complete pin definitions, consult the Meridian installation document.
VIDEO IN
VIDEO OUT
Coaxial Video Cable
To Door Release
Configuration Notes (1 of 2, continued):
4. When the SENSOR input is used, the door station will be turned on whenever the sensor device is activated (Normally Closed contact from 3rdparty supplied device).
5. The RELAY output provides an optional Normally Open dry contact output which is activated whenever the AX-series door station is in use. This can be used to activate any device local to the AXW-AVT (DVR trigger, video switcher activation, local call indication, etc.).
6. Configure AXW-AVT internal jumpers as necessary (see Pg. 21).
Meridian
ST-AiphoneAX1-XS
PWR DIAG TX C/L RX C/E
SYN VID
DR1 DR2 AR1 AR2 CR1 CR2 DT1 DT2 AT1 AT2 CT1 CT2
OPTICAL
VIDEO
1
3
5
1
4
1
3
5
RX TX
(to SR-AiphoneAX1-XS, Pg. 5)
DATAC.C.AUDIO
Optic Fiber
Connection details from AXW-AVT to ST-AiphoneAX1-XS ‘Audio’ Connector Detail:
Pin 1 Audio In ­Pin 2 Audio In + Pin 3 Audio Out ­Pin 4 Audio Out +
‘C.C.’ Connector Detail:
Pin 1 Call Out ­Pin 2 Call Out + Pin 3 Call In + Pin 4 Call In -
‘DATA’ Connector Detail:
Pin 1 & 2 Optional Door
release contact output
Fig. 1
Pg. 3
Please Note:
Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3 responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3
rd
party transmission hardware. Consult the installation manual for the 3rdparty device being utilized
rd
party devices interfacing with it are included here. Aiphone is not
for further information regarding physical mounting, base functionality, power requirements, etc. For the most up-to-date compatibility information, please consult http:// www.aiphone.com or contact Aiphone Technical Support.
For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or available at http://www.aiphone.com).
Pg. 4
CONFIGURATION DIAGRAM: AXW-AVT / AXW-AVR with Meridian Technology Fiber (ST/SR-AiphoneAX1-XS), 2 of 2
Configuration Notes (2 of 2):
1. Connect the AXW-AVR ‘CEU’ connection to an unused Door station input on the AX-CEU and ensure that the AX-CEU has been programmed to accept a video door station on that input (see Pg. 2).
2. Connect the Call In / Call Out and Audio In / Audio Out connections on the AXW-AVR to the Meridian fiber receiver module (as detailed below, Fig. 2). For complete pin definitions, consult the Meridian installation document.
3. The RELAY output on the AXW-AVR provides a Normally Open dry contact output whenever the door station connection is active. This can be used to activate any device local to the AXW-AVT (DVR trigger, video switcher activation, local call indication, etc.).
Meridian
SR-AiphoneAX1-XS
(to ST-AiphoneAX1-XS, Pg. 4)
Optic Fiber
AXW-AVT to SR-AiphoneAX1-XS ‘Audio’ Connector Detail:
Pin 1 Audio In ­Pin 2 Audio In + Pin 3 Audio Out ­Pin 4 Audio Out +
‘C.C.’ Connector Detail:
Pin 1 Call Out ­Pin 2 Call Out + Pin 3 Call In + Pin 4 Call In -
‘DATA’ Connector Detail:
Pin 3 & 4 Optional Door
release contact input (from CEU)
Fig. 2
PWR DIAG TX C/L RX C/E
SYN VID
DR1 DR2 AR1 AR2 CR1 CR2 DT1 DT2 AT1 AT2 CT1 CT2
OPTICAL
VIDEO
1
3
5
1
4
1
3
5
RX TX
Coaxial Video Cable
Application Considerations:
The Meridian fiber modules shown include extra contact closures which may be used for door release output local to the door station (using dry contact output of the AX-CEU as a trigger)
DATAC.C.AUDIO
From AX CEU Door
Release Output
Power supply connections to the Meridian fiber modules are not shown, and are dictated by the mounting method chosen (standalone, rack mount, etc). Contact Meridian Technologies for available options. AXW-AVT / AXW-AVR should be mounted as close as possible to their corresponding Meridian fiber modules. Avoid mounting units near high voltage AC devices, or other sources of inductive noise.
AXW-AVR
CEU
AUDIO IN
+
-
AUDIO OUT
+
-
CALL IN
+
-
CALL OUT
+
-
RELAY
NO NO
VIDEO IN
VIDEO OUT
To AX-CEU (Door Input)
Normally Open contact for remote device activation
(i.e. video switcher, DVR, etc.)
Composite Video Output*
(for CCTV monitor, DVR, etc.)
Please Note:
Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3
rd
party devices interfacing with it are included here. Aiphone is not responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3rdparty transmission hardware. Consult the installation manual for the 3rdparty device being utilized for further information regarding physical mounting, base functionality, power requirements, etc. For the most up-to-date compatibility information, please consult http:// www.aiphone.com or contact Aiphone Technical Support.
For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or
Pg. 5 Pg. 6
available at http://www.aiphone.com).
CONFIGURATION DIAGRAM: AXW-AVT / AXW-AVR with Infinova Fiber (N3732TA-M/-R, N3732RA-M/-R), 1 of 2
AX-DM or IE/IF-Series
Audio Door Station
CCTV Camera 75 Ohm, 1V Peak-to-peak (Independently powered)
*
AX-DV
Configuration Notes (1 of 2):
1. AX-series video door station connects to ‘DOOR’ input of AXW-AVT. Ensure that the “CCTV / DOOR’ switch on the AXW-AVT is in the ‘DOOR’ position.
*2. Alternatively, an IE/IF-series or AX-DM audio door may be used, along with
3rdparty CCTV camera. Connect audio door station to ‘Door’ input (following the wiring method shown in the AX-series installation manual, pg. 12). Connect the camera to ‘Video In’ and put the ‘CCTV / DOOR’ switch in the ‘CCTV’ position.
3. Connect the Call In / Call Out and Audio In / Audio Out connections on the AXW-AVR to the terminal block of the Infinova N3732TA-M, as shown. For detailed terminal definitions, consult the Infinova installation document.
CAT-5e
Coax
AXW-AVT
24V
+
-
RELAY
NO NO
SENSOR
NC NC
CALL IN
+
-
CALL OUT
+
-
AUDIO IN
+
-
AUDIO OUT
+
-
DOOR
VIDEO IN
VIDEO OUT
PS-2420UL
+
-
Normally Open contact for remote device activation
(i.e. video switcher, DVR, etc.)
Normally Closed input for remote activation
(i.e. motion sensor, loop detector, etc.)
****
Coaxial Video Cable
Infinova
N3732TA-M
PWR
V
OP
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
Configuration Notes (1 of 2, continued):
4. When the SENSOR input is used, the door station will be turned on whenever the sensor device is activated (Normally Closed contact from 3rdparty supplied device).
5. The RELAY output provides an optional Normally Open dry contact output which is activated whenever the AX-series door station is in use. This can be used to activate any device local to the AXW-AVT (DVR trigger, video switcher activation, local call indication, etc.).
6. Configure AXW-AVT internal jumpers as necessary (see Pg. 21).
Optic Fiber
(to N3732TA-M, Pg. 9)
**The Infinova N3732TA provides only a single relay output, which may be used to control the door station’s standby mode (when connected to the ‘Call Out’ terminals on the AXW-AVT), or for door release. If utilized for door release, ensure that the ‘Call Out’ terminals on the AXW-AVT are shorted together. Note: This will cause
the door station to be in a constant-on state, which may reduce the lifespan of the AX-series door station.
Please Note:
Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3 responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3
rd
party transmission hardware. Consult the installation manual for the 3rdparty device being utilized
rd
party devices interfacing with it are included here. Aiphone is not
for further information regarding physical mounting, base functionality, power requirements, etc. For the most up-to-date compatibility information, please consult http:// www.aiphone.com or contact Aiphone Technical Support.
For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or
Pg. 7 Pg. 8
available at http://www.aiphone.com).
CONFIGURATION DIAGRAM: AXW-AVT / AXW-AVR with Infinova Fiber (N3732TA-M/-R, N3732RA-M/-R), 2 of 2
Configuration Notes (2 of 2):
1. Connect the AXW-AVR ‘CEU’ connection to an unused Door station input on the AX-CEU and e nsure that the AX-CEU has been programmed to accept a video door station on that input (see Pg. 2).
2. Connect the Call In / Call Out and Audio In / Audio Out co nnections on the AXW-AVR to the terminal block of the Infinova N3732RA-M, as shown. For detailed terminal definitions, cons ult the Infinova installation document.
3. Per the Infinova installation manual, set JP11 and JP21 for “600-Ohm, Balanced” audio connection.
4. The RELAY output on the AXW-AVR provides a Normally Open dry contact output whenever the door station connection is active. This can be used to activate any device local to the AXW-AVT (DVR trigger, video switcher activation, local call indication, etc.).
Optic Fiber
(to N3732TA-M, Pg. 8)
Infinova
N3732RA-M
PWR
V
OP
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16
Coaxial Video Cable
Application Consideratison:
**If the Infinova fiber modules relay is to be used for door release, the ‘Call Out’ connection on the AXW-AVR will not be used. Instead, connect pins 15/16 from the fiber module to the appropriate door release output on the AX-CEU. Be sure to short together the ‘Call Out’ terminations on the AXW-AVT, as noted on Pg. 8-9. Power supply connections to the Infinova fiber modules are not shown, and are dictated by the mounting method chosen (standalone, rack mount, etc.). Contact Infinova for available options. AXW-AVT / AXW-AVR should be mounted as close as possible to their corresponding Infinova fiber modules. Avoid mounting units near high voltage AC devices, or other sources of inductive noise.
AXW-AVR
CEU
AUDIO IN
+
-
AUDIO OUT
+
-
CALL IN
+
-
**
CALL OUT
+
-
RELAY
NO NO
VIDEO IN
VIDEO OUT
To AX-CEU
(Door Input)
Normally Open contact for remote device activation
(i.e. video switcher, DVR, etc.)
Composite Video Output
(for CCTV monitor, DVR, etc.)
Please Note:
Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3 responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3
rd
party transmission hardware. Consult the installation manual for the 3rdparty device being utilized
rd
party devices interfacing with it are included here. Aiphone is not
for further information regarding physical mounting, base functionality, power requirements, etc. For the most up-to-date compatibility information, please consult http:// www.aiphone.com or contact Aiphone Technical Support.
For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or
Pg. 9 Pg. 10
available at http://www.aiphone.com).
CONFIGURATION DIAGRAM: AXW-AVT / AXW-AVR with AFI (American Fibertek) Fiber (MT/MR-89A-AX), 1 of 2
AX-DM or IE/IF-Series
Audio Door Station
CCTV Camera 75 Ohm, 1V Peak-to-peak (Independently powered)
*
AX-DV
CAT-5e
Coax
AXW-AVT
24V
+
-
RELAY
NO NO
SENSOR
NC NC
CALL IN
+
-
CALL OUT
+
-
AUDIO IN
+
-
AUDIO OUT
+
-
DOOR
VIDEO IN
VIDEO OUT
PS-2420UL
+
-
Normally Open contact for remote device activation
(i.e. video switcher, DVR, etc.)
Normally Closed input for remote activation
(i.e. motion sensor, loop detector, etc.)
Configuration Notes (1 of 2, continued):
4. When the SENSOR input is used, the door station will be turned on whenever the sensor device is activated (Normally Closed contact
rd
from 3
party supplied device).
5. The RELAY output provides an optional Normally Open dry contact output which is activated whenever the AX-series door station is in use. This can be used to activate any device local to the AXW-AVT (DVR trigger, video switcher activation, local call indication, etc.).
6. Configure AXW-AVT internal jumpers as necessary (see Pg. 21).
To AFI specified/supplied
power source
AudioContactContact
+
+
­+
-
-
+
-
Video INOptical
I/O
12VDC
Configuration Notes (1 of 2):
Door Release/
Contact Out (optional)
AFI MT-89A-AX
1. AX-series video door station connects to ‘DOOR’ input of AXW-AVT. Ensure that the “CCTV / DOOR’ switch on the AXW-AVT is in the ‘DOOR’ position.
*2. Alternatively, an IE/IF-series or AX-DM audio door may be used, along with
3rdparty CCTV camera. Connect audio door station to ‘Door’ input (following the wiring method shown in the AX-series installation manual, pg. 12). Connect the camera to ‘Video In’ and put the ‘CCTV / DOOR’ switch in the
Coaxial Video Cable
Optic Fiber
(to MR-89A-AX, Pg. 13)
‘CCTV’ position.
3. Connect the Call In / Call Out and Audio In / Audio Out connections on the AXW-AVT to the terminal block of the AFI MT-89A-AX, as shown. For detailed terminal definitions, consult the AFI MT-89A-AX installation sheet.
Please Note:
Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3 responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3
rd
party transmission hardware. Consult the installation manual for the 3rdparty device being utilized for further information regarding physical mounting, base functionality, power requirements, etc. For the most up-to-date compatibility information, please consult http:// www.aiphone.com or contact Aiphone Technical Support.
For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or
Pg. 11 Pg. 12
available at http://www.aiphone.com).
rd
party devices interfacing with it are included here. Aiphone is not
CONFIGURATION DIAGRAM: AXW-AVT / AXW-AVR with AFI (American Fibertek) Fiber (MT/MR-89A-AX), 2 of 2
Configuration Notes (2 of 2):
1. Connect the Call In / Call Out and Audio In / Audio Out connections on the AXW-AVR to the terminal block of the AFI MR-89A-AX, as shown. For detailed terminal definitions, consult the AFI MR-89A-AX installation sheet.
2. Connect the AXW-AVR ‘CEU’ connection to an unused Door station input on the AX-CEU and ensure that the AX-CEU has been programmed to accept a video door station on that input (see Pg. 2).
3. The RELAY output on the AXW-AVR provides a Normally Open dry contact output whenever the door station connection is active. This can be used to activate any device local to the AXW-AVT (DVR trigger, video switcher activation, local call indication, etc.)
To AFI-specified /supplied
power source
AudioContactContact
+
+
-
+
-
-
+
-
Video
OUT
Optical
I/O
12VDC
AFI MR-89A-AX
AXW-AVR
CEU
AUDIO IN
+
-
AUDIO OUT
+
-
CALL IN
+
-
CALL OUT
+
-
RELAY
NO NO
VIDEO IN
VIDEO OUT
To AX-CEU (Door Input)
Normally Open contact for remote device activation
(i.e. video switcher, DVR, etc.)
Composite Video Output
(for CCTV monitor, DVR, etc.)
Coaxial Video Cable
Door Release/
Contact In (Optional)
Optic Fiber
Application Considerations:
(to MT-89A-AX, Pg. 12)
AXW-AVT / AXW-AVR should be mounted as close as possible to their corresponding AFI fiber modules. Avoid mounting units near high voltage AC devices, or other sources of inductiv e noise.
Please Note:
Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3 responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3
rd
party transmission hardware. Consult the installation manual for the 3rdparty device being utilized for further information regarding physical mounting, base functionality, power requirements, etc. For the most up-to-date compatibility information, please consult http:// www.aiphone.com or contact Aiphone Technical Support.
For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or
Pg. 13 Pg. 14
available at http://www.aiphone.com).
rd
party devices interfacing with it are included here. Aiphone is not
CONFIGURATION DIAGRAM: AXW-AVT / AXW-AVR with KBC Networks (FPVB1-AB1-IB2-ST, FPVB1-AB1-IB2-SR), 1 of 2
Configuration Notes (1 of 2):
1. AX-series video door station connects to ‘DOOR’ input of AXW-AVT. Ensure that the “CCTV / DOOR’ switch on the AXW-AVT is in the ‘DOOR’ position.
*2. Alternatively, an IE/IF-series or AX-DM audio door may be used, along
with 3
rd
party CCTV camera. Connect audio door station to ‘Door’ input (following the wiring method shown in the AX-series installation manual, pg. 12). Connect the camera to ‘Video In’ and put the ‘CCTV / DOOR’ switch in the ‘CCTV’ position.
3. Connect the Call In / Call Out and Audio In / Audio Out connections on the AXW-AVT to the Meridian fiber transmitter module (as detailed at right, Fig. 1). For complete pin definitions, consult the Meridian installation document.
AX-DM or IE/IF-Series
Audio Door Station
CCTV Camera 75 Ohm, 1V Peak-to-peak (Independently powered)
*
AXW-AVT
24V
+
-
RELAY
NO NO
SENSOR
NC NC
CALL IN
+
-
CALL OUT
+
-
AUDIO IN
+
-
AUDIO OUT
+
-
DOOR
PS-2420UL
+
-
Normally Open contact for remote device activation (i.e. video switcher, DVR, etc.)
Normally Closed input for remote activation (i.e. motion sensor, loop detector, etc.)
AX-DV
CAT-5e
Coax
VIDEO IN
VIDEO OUT
Coaxial Video Cable
Configuration Notes (1 of 2, continued):
4. When the SENSOR input is used, the door station will be turned on whenever the sensor device is activated (Normally Closed contact from
rd
3
party supplied device).
5. The RELAY output provides an optional No rmally Open dry contact output which is activated whenever the AX-series door station is in use. This can be used to activate any device local to the AXW-AVT (DVR trigger, video switcher activation, local call indication, etc.).
6. Configure AXW-AVT internal jumpers as necessary (see Pg. 21).
KBC: FPVB1-AB1-IB2-ST
A+ A- GND A+ A- GND
V1
AUDIO 1 AUDIO 2 C1 C2 C3 C4
To Door Release
Please Note:
Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3 responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3
rd
party transmission hardware. Consult the installation manual for the 3rdparty device being utilized
rd
party devices interfacing with it are included here. Aiphone is not
for further information regarding physical mounting, base functionality, power requirements, etc. For the most up-to-date compatibility information, please consult http:// www.aiphone.com or contact Aiphone Technical Support.
For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or
Pg. 15 Pg. 16
available at http://www.aiphone.com).
CONFIGURATION DIAGRAM: AXW-AVT / AXW-AVR with KBC Networks (FPVB1-AB1-IB2-ST, FPVB1-AB1-IB2-SR), 1 of 2
Configuration Notes (2 of 2):
1. Connect the Call In / Call Out and Audio In / Audio Out connections on the AXW-AVR to the terminal block of the AFI MR-1890, as shown. For detailed terminal definitions, consult the AFI MR-1890 installati on she et.
2. Connect the AXW-AVR ‘CEU’ connection to an unus ed Door station input on the AX-CEU and ensure that the AX-CEU has been programmed to accept a video door station on that input (see Pg. 2).
3. The RELAY output on the AXW-AVR provides a Normally Open dry contact output whenever the door station connection is active. This can be used to activate any device local to the AXW­AVT (DVR trigger, video switcher activation, local call indication, etc.).
Normally Open contact for remote device activation
(i.e. video switcher, DVR, etc.)
To AX-CEU
(Door Input)
AXW-AVR
CEU
AUDIO IN
+
-
AUDIO OUT
+
-
CALL IN
+
-
CALL OUT
+
-
RELAY
NO NO
VIDEO IN
V1
KBC: FPVB1-AB1-IB2-SR
A+ A- GND A+ A- GND
AUDIO 1 AUDIO 2 C1 C2 C3 C4
To AX-CEU
(Door Release Output)
Composite Video Output
(for CCTV monitor, DVR, etc.)
VIDEO OUT
Application Considerations:
Power supply connections to the KBC fiber modules are not shown, and are dictated by the mounting method chosen (standalone, rack mount, etc.). Contact KBC for available options. AXW-AVT / AXW-AVR should be mounted as close as possible to their corresponding KBC fi ber modules. Avoid mounting units near high voltage AC devices, or other sources of inductive noise.
Please Note:
Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3 responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3
rd
party transmission hardware. Consult the installation manual for the 3rdparty device being utilized for further information regarding physical mounting, base functionality, power requirements, etc. For the most up-to-date compatibility information, please consult http:// www.aiphone.com or contact Aiphone Technical Support.
For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or
Pg. 17 Pg. 18
available at http://www.aiphone.com).
rd
party devices interfacing with it are included here. Aiphone is not
CONFIGURATION DIAGRAM: AXW-AVT with Axis 243SA Video Server (Standalone Only)
AX-DM or IE/IF-Series
Audio Door Station
CCTV Camera 75 Ohm, 1V Peak-to-peak (Independently powered)
*
AX-DV
Configuration Notes:
1. AX-series video door station connects to ‘DOOR’ input of AXW-AVT. Ensure that the “CCTV / DOOR’ switch on the AXW-AVT is in the ‘DOOR’ position.
CAT-5e
Coax
AXW-AVT
24V
+
-
RELAY
NO NO
SENSOR
NC NC
CALL IN
+
-
CALL OUT
+
-
AUDIO IN
+
-
AUDIO OUT
+
-
DOOR
VIDEO IN
VIDEO OUT
PS-2420UL
+
-
Normally Open contact for remote device activation
(i.e. video switcher, DVR, etc.)
Normally Closed input for remote activation
(i.e. motion sensor, loop detector, etc.)
Coaxial Video Cable
Axis 243SA Application Considerations:
The Axis 243SA can only be used in ‘Standalone’ configuration (i.e., utilizing a PC as a master station). When used in standalone configuration, Aiphone recommends Controlware’s VIPDoorControl software. For further details, see http://www.vipdoorcontrol.com. Consult the Axis 243SA Installation and User manuals for further information pertaining to video server installation and configuration.
POWER
1
23456789101112
To Axis-supplied
power source
NETWORK
RS-232
To Network
Axis 243SA
(Back View)
*2. Alternatively, an IE/IF-series or AX-DM audio door may be used, along
with 3rdparty CCTV camera. Connect audio door station to ‘Door’ input (following the wiring method shown in the AX-series installation manual, pg. 12). Connect the camera to ‘Video In’ and put the ‘CCTV / DOOR’ switch in the ‘CCTV’ position.
3. Connect the Call In / Call Out and Audio In / Audio Out connections on
LINE/MIC
IN
VIDEO
LINE OUT
IN OUT
1 2 3 4
75Ω ON
STATUS
NETWORK POWER
AXIS 243SA Video Server
Axis 243SA
(Front View)
the AXW-AVT to the Axis 243SA connectors, as shown.
4. Configure AXW-AVT internal jumpers as necessary (see Pg. 21).
Please Note:
Only information pertaining to the connection and operation of the AXW-AVT / AXW-AVR and listed 3 responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3
rd
party transmission hardware. Consult the installation manual for the 3rdparty device being utilized for further information regarding physical mounting, base functionality, power requirements, etc. For the most up-to-date compatibility information, please consult http:// www.aiphone.com or contact Aiphone Technical Support.
For complete AX system installation, wiring, and programming information, please consult the AX Installation Manual (included on CD with AX Central Exchange Unit, or
Pg. 19 Pg. 20
available at http://www.aiphone.com).
rd
party devices interfacing with it are included here. Aiphone is not
AXW-AVT Internal Jumper Settings:
The AXW-AVT has three internal jumper settings to control the functionality and conditioning of the audio circuitry. These should be adjusted as necessary, based on the selection of fiber / Ethernet equipment used. To access these jumpers, the chassis of the AXW-AVT will need to be opened. Adjusting these jumper settings will NOT invalidate the AXW-AVT’s warranty.
Transmitting Gain (CN3): Controls the amount of amplification applied to the outgoing audio (‘Audio Out’)
connection of the AXW-AVT. A ‘Low’ setting provides no gain, whereas a ‘Hi’ setting applies approximately +10db of amplification. Default position is ‘Low.’
Receive Gain (CN4): Controls the amount of amplification applied to the incoming audio (‘Audio In’)
connection of the AXW-AVT. A ‘Low’ setting provides no gain, whereas a ‘Hi’ setting applies approximately +10db of amplification. Default position is ‘Low.’
Muting Circuit (CN5): The ‘Muting Circuit’ controls whether audio to/from the door station is
completely full-duplex, or limited to one direction or the other (semi-duplex). This adjustment is required in situations where latency may be present between audio transmission and reception (i.e., Ethernet). In such situations, the muting circuit should be set to ‘On’ to reduce audible echoing. In situations where latency is not an issue (i.e., fiber, direct connections, etc.), this should be left in the default ‘Off’ position.
CN3: Transmitting Gain
High / Low
CN5: Muting Circuit
On / Off
CN4: Receive Gain
High / Low
Pg. 21
SPECIFICATIONS:
Power:
AXW-AVT 24V DC, 500mA (use Aiphone PS-2420UL)
AXW-AVR Supplied by AX CEU Video Input & Output: Composite 1V Peak-to-Peak, NTSC Video Connectors: BNC Door input: RJ-45 Relay: Normally Open contact output; 30V DC, 1A Sensor: Normally Closed contact input Wire: CAT-5e, 24AWG UTP-4 Wiring distance:
AXW-AVT to Door, Max. 980' cumulative
AXW-AVR to CEU
AXW-AVT / -AVR to As close as possible; do not exceed 16'
3rdparty devices
Dimensions:
AXW-AVT + AXW-AVR 1-5/8"H x 7"W x 4"D
FCC Class B Verification
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device , pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures: — Reorient or locate the receiving antenna. — Increase the separation between the equipment and receiver. — Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
Note:
Only information pertaining to the connection and operation of the AXW-AVT, AXW-AVR and devices interfacing with it are included here. Aiphone is not responsible for attempts to connect the AXW-AVT / AXW-AVR to untested 3 transmission hardware. For the most up-to-date compatibility information, please consult http://www.aiphone.com or contact Aiphone Technical Support. For complete installation, wiring, and programming information regarding the AX system, please refer to the AX Installation Manual, which is included on the CD provided with the AX CEU, or available for download at http://www.aiphone.com.
rd
party
Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005 (425) 455-0510 FAX (425) 455-0071
Toll Free Technical Support:
(800) 692-0200
E-mail tech@aiphone.com
Pg. 22
AXW-AVT,AVR Instr.
0311JD
Loading...