Aiphone AX SERIES INSTALLATION &OPERATION MANUAL

- 1 -
1205 A
AX SERIES
Integrated Security &Communication System
INSTALLATION &OPERATION MANUAL
AX-248C
- 2 -
General Prohibitions
General Precautions
Prohibition on Subjecting the Unit to Water
WARNING
(Negligence could result in death or serious injury to people)
1. High voltage is present internally. Do not open the case. Electric shock could result.
2. Do not dismantle or alter the unit. Fire or electric shock could result.
3. Do not connect any non-specified power source to the +, - terminals, and do not install two power supplies in parallel to a single input. Fire, damage to the unit, or system malfunction could result.
4. Keep the unit away from water or any other liquid. Fire or electric shock could result.
5. Do not put any metal or paper into the unit through the openings. Fire or electric shock could result.
6. Do not plug or unplug with wet hands. Electric shock could result.
7. Keep AC plug away from moisture or dust. Fire could result.
8. Keep AC cord from being marred or crushed. If the AC cord is fractured, fire or electric shock could result.
9. Do not use a power supply with a voltage other than specified. Fire or electric shock could result.
10. Insert AC plug completely and securely into AC outlet. Otherwise, fire or electric shock could result.
11. The unit is not of explosion-proof. Do not install or use near gases or flammable materials. Fire or explosion could result.
CAUTION
(Negligence could result in injury to people or damage to property)
1. Before turning on power,make sure wires are not crossed or shorted. Fire or electric shock could result.
2. When mounting the unit on wall, install the unit in a convenient location, but not where it could be jarred or bumped. Injury could result.
3. Do not install or make any wire terminations while power supply is plugged in. It can cause electrical shock or damage to the unit.
4. Do not install the unit in any of the following locations. Fire, electric shock, or unit trouble could result.
Places under direct sunlight, or near heating equipment that varies in
temperature.
Places subject to dust, oil, chemicals, hydrogen sulfide (hot spring).Places subject to moisture and humidity extremes, such as bathroom, cellar,
greenhouse, etc.
Places where the temperature is quite low, such as inside a refrigerated area or
in front of air-conditioner.
Places subject to steam or smoke (near heating or cooking surfaces).Where noise generating devices such as dimmer switches, invertor electrical
appliances, are closeby.
5. On products with ground terminals, connect to an earth ground. Fire or malfunction could result.
6. For DC powered systems, use Aiphone power supply model specified with system. If non-specified product is used, fire or malfunction could result.
7. Do not put anything on or cover the unit with cloth, etc. Fire or unit trouble could result.
8. Do not put high pressure on the monitor cover. If fractured, injury could result.
9. If LCD is punctured, do not allow contact with the liquid crystal inside. Inflammation could result. If necessary, gargle your mouth and clean your eyes or skin with clear water for at least 15 minutes, and consult your doctor.
10. Do not mount the unit in a place subjected to constant vibration or impact. If jarred or knocked off the wall, injury could result .
GENERAL PRECAUTIONS
1. All the units, except for door station, is designed for indoor use only. Do not use outdoor.
2. In areas where broadcasting station antennas are close by, the intercom system may be affected by radio frequency interference.
3. If a cellular phone is used close by, the unit may malfunction.
4. This product, being a control unit of door release, should not be used as a crime­prevention device.
5. It must be noted in advance that the LCD panel, though manufactured with very high precision techniques, inevitably will have a very small portion of its picture elements always lit or not lit at all. This is not considered a unit malfunction.
6. Door station is weather-resistant, but do not spray high-pressure water. Unit trouble could result.
7. Keep the unit more than 1 m away from Radio or TV set.
8. For wiring, specify CAT5e straight cable.
9. Due to the environmental sound around the unit, it may hinder smooth communication, but this is not a malfunction.
10. When outside temperature lowers sharply after rainfall, etc., the inside of camera may fog up slightly, causing a blurry picture, but this is not a malfunction. Normal operation will be restored when moisture evaporates.
PRECAUTIONS
- 3 -
1 SYSTEM CONFIGURATIONS
System Configurations 4 Capacity 5 External integration example, Door station 6 Master station, Central exchange unit 7
2 PACKAGE CONTENTS
Package contents (Mullion door station), (Vandal-resistant door station) 8 Package contents (Master station), (16 call add-on selector), (Central exchange unit) 9
3 INSTALLATION
Installation location (Master station), (Door station), Visible range 10 Cable, Wiring distance 11
4 MOUNTING
Mounting (Mullion door station) 12 Mounting (Vandal-resistant door station) 13 Door station installation dimensions 14 Mounting (Master station) 16 Mounting (Central exchange unit) 17
5 WIRING 18 6 NAMES
Names (Door station) 20 Names (Master station) 21 Names (Central exchange unit) 22
7 SETTING UP
Setup tool 24 Starting the setup 26 Central exchange unit setting, Master station setup input 27 Door station setting 28 Time out setting 30 CO Transfer, Communication Method, Edit menu 31 Uploading settings and save 32 Print setup 33 System monitor 34 Log 35 Help, Exiting the setup tool 36
8 OPERATIONS
Calling a master station from door station and communicating 37 Calling a master station from a master station and communicating, Privacy (PRIV)function 38 CO line call from door station and communicating, All call (normal) (master station paging) 39 All call (priority) (master station paging), Monitor 40 Scan monitor, Activating door release, Priority 41 List of function button operations for each own master station mode 42 New called event 42
9 TECHNICAL PRECAUTIONS 43 10 SPECIFICATIONS 43
- 4 -
1
SYSTEM CONFIGURATIONS
[1]
[1]
Max. 8
Max. 24
Max. 120
PS
[2]
[2]
[6]
[3]
DC 24 V 2 A
DC 24 V 2 A
[4]
[5]
Max. 4
Max. 8
Max. 32
Max. 32
Max. 32
PS
PS
[6]
[3]
[4]
[5]
PS
CAT5e
Max. 300 m
CAT5e
Max. 300 m
CAT5e
Max. 300 m
CAT5e
Max. 300 m
CAT5e
Max. 300 m
CAT5e
Max. 300 m
CAT5e
Max. 300 m
CAT5e
Max. 300 m
CAT5e
Max. 300 m
CAT5e
CAT5e
Max. 300 m
CAT5e
Max. 300 m
CAT5e
Max. 300 m
RS-232C
Max. 15 m
CAT5e
Max. 300 m
CAT5e
Max. 300 m
RS-232C
Max. 15 m
CAT5e
CAT5e
AX-084C
AX-248C
AX-320C
AX-320C
AX-320C
DC 24 V 2 A
DC 24 V 2 A
1-1
- 5 -
1-1 1-2
System Configurations
[1] Door station [2] Master station
• A maximum of seven 16-call add-on selectors (AX-16SW) can be connected.
[3] Central Exchange Unit
• A maximum of three Add-on exchange units (AX-320C) can be connected.
[4] PC [5] Other external connections
• Access control system
• CCTV system
• CO line adaptor
• Video output
[6] Power supply x2
Capacity
• Door station: Maximum 120 stations (When AX-248C x1, AX-320C x3 used)
• Master station: Maximum 4 stations (when AX-084C used) Maximum 8 stations (when AX-248C used)
• Power supply: PS-2420UL (DC 24 V, 2 A) PS-2420S (DC 24 V, 2 A) PS-2420DIN (DC 24 V, 2 A) For audio x1, for video x1
• Number of talk paths: 2
• Number of video paths: 2
• All call: 1
• Video monitor: 2 (same as talk paths and video paths)
• Scan monitor: 1
- 6 -
1-4
Door station
a. Audio door station b. Video door station c. Surface mount type d. Flush mount type e. Without proximity card reader f. With proximity card reader g. Standard type h. Vandal-resistant type For North America only
1-3
External integration example
[1] CCTV system [2] Access control system [3] AC transformer PT1210N (AC 12V, 10VA, for North America
only) [4] Electric door strike EL-9S a. System log (RS-232C) b. Camera switching c Video signal d. Remote door release signal (RS-232C) e. Door release dry contact (N/O or N/C programmable) f. Door release record g. Card ID / Data (Wiegand)
[1]
[2]
[3]
[4]
PC
AX-084C AX-248C
c
a
d
b
c
e
g
e
fd
AX-DM IE-JA
IE-SS(SOP)
AX-DV AX-DVF
AX-DV-P AX-DVF-P
IF-DA
a
cdcd
b
e
f
g
h
g
h
- 7 -
1-6
Central exchange unit
[1] AX-084C Standard central exchange unit
A maximum of 4 master stations and 8 door stations can be connected.
[2] AX-248C Expanded central exchange unit
A maximum of 8 master stations and 24 door stations can be connected.
[3] AX-320C Add-on exchange unit
A maximum of 32 door stations can be connected.
A maximum of 3 add-on exchange units can be connected in a
system.
1-5
Master station
[1] AX-8M audio master station
Maximum 4 stations (with AX-084C), or 8 stations (with AX­248C).
[2] AX-8MV color video maser station
Maximum 4 stations (with AX-084C), or 8 stations (with AX­248C).
[3] AX-16SW 16 call add-on selector
A maximum of seven AX-16SW can be connected to each AX­8M or AX-8MV.
NOTES: 1. A headset can also be used with the AX-8M and AX-
8MV (computer-style).
2. A multi-pin connector is supplied with the AX-8M and AX-8MV, providing the following features: footswitch activation the TALK function (footswitch supplied locally); external signaling of call tones (through IER-2), and composite video output (1V p­p).
[1] [2]
[3]
[1]
[2]
[3]
- 8 -
2-2
Package contents (Vandal-resistant door station)
[1] Vandal-resistant door station AX-DV, AX-DVF, AX-DV-P, AX-
DVF-P [2] Special screwdriver [3] Directory card [4] Mounting screws and Anchor bolts (AX-DV, AX-DV-P) [5] Mounting screws (AX-DVF, AX-DVF-P) [6] Back box (AX-DVF,AX-DVF-P) [5] and [6] are packed assembled with the AX-DVF or AX-
DVF-P.
2
PACKAGE CONTENTS
2-1
Package contents (Mullion door station)
[1] AX-DM mullion audio door station [2] Mounting screws [3] Operation manual
[1] [2] [3]
[1] [2] [3]
[4]
[6]
[5]
- 9 -
2-4
Package contents (16 call add-on selector)
[1] AX-16SW 16-call add-on selector [2] Mounting screws [3] Joint bracket x2 [4] Connector cable [5] Screws for connecting master and add-on selector
2-3
Package contents (Master station)
[1] AX-8M audio master station, AX-8MV color video master
station [2] Mounting screws [3] Mounting bracket [4] Optional connector (6-pin) [5] Tie wrap (when optional connector is used with desktop
installation)
2-5
Package contents (Central exchange unit)
[1] AX-084C, AX-248C, or AX-320C exchange unit [2] Mounting screws [3] Rack and wall mounting brackets x2 [4] Installation CD (AX-084C, AX-248C), including set-up
software program and instruction manual.
[5] Mounting screws (for 19-inch rack mounting)
[1] [2]
[3] [5][4]
[1] [2] [3]
[4] [5]
[1] [2] [3]
[4]
[5]
- 10 -
3-1
Installation location (Master station)
Install the video master station in a place where the screen is not exposed to direct sunlight.
3
INSTALLATION
3-2
Installation location (Door station)
Do not install a video door station in any of the following locations where lighting or the ambient environment could impact the display on the video master station due to the characteristics of the door station's camera.
1. Locations subject to direct sunlight
2. Under street lights or door lights
3. Other locations subject to strong lighting conditions
3-3
Visible range
This is the range visible from the camera position.
12 3
65 cm
2'1"
150 cm
5'
50 cm
20"
50 cm / 20"
AX-DV
AX-DVF
AX-DV-P
AX-DVF-P
95 cm / 3'1"
185 cm
6'1"
120 cm
3'11"
AX-DV
AX-DVF
AX-DV-P
AX-DVF-P
- 11 -
3-5
Wiring distance
3-4
Cable
1. CAT5e (24AWG) straight-thru EIA/TIA 568B
1 White-orange 2 Orange 3 White-green 4 Blue 5 White-blue 6 Green 7 White-brown 8 Brown
2. Ø 0.8 to 1.6 mm (20 to 14 AWG)
1. In order to prevent mis-wiring, label each incoming cable with its station location/name.
2. Do not pull or put excess strain on the CAT5e cable. The maximum tension on the cable is set to 11.2 kg (110 N).
AX-DM
IF-DA IE-JA IE-SS
AX-DV
AX-DVF
AX-DV-P
AX-DVF-P
AX-320C
AX-320C
AX-084C AX-248C
+ AX-16SW
M
D
E1
E4
E2
AX-320C
E3
A
B
C
AX-8M
AX-8MV
PS-2420UL
PS-2420S
PS-2420DIN
PS
D
AX-248C
AX-320C
AX-320C
AX-320C
RJ-45 Plug
Pin 1
12345678 12345678
1
2
CAT5e
CAT5e
CAT5e
2
AX-DM IF-DA
AX-DV AX-DV-P AX-DVF AX-DVF-P
AX-320C
AX-084C AX-248C
PS-2420UL
PS-2420S
PS-2420DIN
AX-8M AX-8MV
IE-JA IE-SS
AX-084C AX-248C
PS
AX-248C
AX-320C
AX-248C
-
-
10 m (33')
-
A B C D
CAT5e (24AWG) Ø0.8 ~ 1.6 mm (20 ~ 14AWG)
300 m (980') 300 m (980')
-
5 m (16')
- 12 -
4
MOUNTING
4-1
Mounting (Mullion door station)
1. Connect the CAT5e cable to the rear of the AX-DM. Use wires #3 (white-green) and #6 (green) as one conductor, and #7 (white-brown) and #8 (brown) as the other conductor (RJ-45 jack not used at Mullion door station). The other pairs are not used.
2. Connect the white-green/green pair to the red AX-DM wire, and the white-brown/brown pair to the brown AX-DM wire. (Non-polarized, so opposite connection will work as well.) When connecting an IE/IF door station, connect white­green/green pair to "1" and white-brown/brown pair to "2". (Use TIA/EIA568B standard)
3. Lift up the front cover from the bottom and set aside.
4. Fasten unit to wall with the mounting screws. Align the front cover with the top hook and clip on at the bottom.
[1] CAT5e straight-thru cable [2] Front cover [3] Mounting screws When mounting AX-DM on a thin mounting surface
(aluminum plate, etc.), holes should be 3.5 mm diameter. If the plate is thick, drill holes at least 25 mm deep; then mount with self-threading screws."
[1]
1
3
AX-DM
CAT5e
[2]
[3]
[3]
4
2
142 mm
5-9/16" 71 mm 2-13/16"
Ø16 mm 5/8"
1 2
4 5
3
6 7 8
- 13 -
Mounting (Vandal-resistant door station)
1. Open the rear cover of the surface mount door station and insert the CAT5e cable (RJ45 plug). For the AX-DV-P, pass it through either the top or bottom cable inlet hole. For the AX-DV, pass it through the top cable inlet hole.
2. Mount as shown in figure 2.
3. Open the rear cover of the flush mount door station and insert the CAT5e cable. Pass cable through either the top or bottom cable inlet hole.
4. Mount as shown in figure 4.
5. For a door station with the proximity card reader, install the card reader from the back.
[1] CAT5e straight-thru cable [2] Special screwdriver [3] Front panel [4] Directory card [5] Mounting screws [6] Anchor bolts [7] Back box [8] Proximity card reader (ProxPoint Plus 6005B from HID
CORPORATION) Always close the rear cover after installation. (Lock it by sliding the cover to the "CLOSE" position.)
When using AX-DV-P, it is necessary to drill a hole for the
card reader wiring.
4-2
AX-DV
AX-DV-P
AX-DV-P
AX-DVF
AX-DVF-P
AX-DVF
AX-DVF-P
1
3
4
5
214 mm 8-7/16"
45 mm 1-25/32"
114 mm 4-1/2"
77 mm 3"
[1]
[2]
[2]
[8]
[4]
[3]
[7]
[5]
2
3
[2]
[3]
[4]
[6]
[5]
6mm
1/4"
35mm 1-3/8"
167 mm 6-9/16"
[1]
221.5 mm 8-3/4"
27.5 mm 1-3/32"
- 14 -
4-3
AX-DV
77 mm
3"
8.5mm 5/16"
1.3 mm 1/16"
100 mm
4"
24 mm
15/16"
82.5 mm
3-1/4"
82.5 mm
3-1/4"
14 mm
9/16"
14 mm
9/16"
167 mm
6-9/16"
195 mm
7-11/16"
60.5 mm
2-3/8"
106.5 mm
4-3/16"
AX-DV-P
77 mm
3"
8.5 mm 5/16"
1.3 mm 1/16"
100 mm
4"
24 mm
15/16"
14 mm
9/16"
9.5 mm
3/8"
221.5 mm
8-3/4"
245 mm
9-5/8"
87.5 mm
3-7/16"
27.5 mm
1-1/16"
106.5 mm
4-3/16"
AX-DVF
104 mm
4-1/8"
114 mm
4-1/2" (BOX)
16 mm
5/8"
16 mm
5/8"
114 mm
4-1/2" (BOX)
16 mm
5/8"
16 mm
5/8"
146 mm
5-3/4"
47.5 mm
1-7/8"
16 mm
5/8"
26 mm
1"
246 mm
9-11/16"
194 mm
7-5/8"
26 mm
1"
16 mm
5/8"
16 mm
5/8"
16 mm
5/8"
214 mm
8-7/16"
(BOX)
10 mm
3/8"
10 mm
3/8"
10 mm
3/8"
10 mm
3/8"
AX-DVF-P
104 mm
4-1/8"
5 mm 3/16"
5 mm 3/16"
146 mm
5-3/4"
47.5 mm
1-7/8"
26 mm
1"
26 mm
1"
295 mm
11-5/8"
243 mm
9-9/16"
263 mm
10-3/8"
(BOX)
[2]
Ø16 mm 5/8"
[1]
[2]
[1]
[2]
[1]
[1]
Loading...
+ 31 hidden pages