Aiphone AX-DVF-XP, AX-DV-XP Instruction Manual

Page 1
Door Station with Standalone Prox Reader
- INSTRUCTIONS -
The AX-DV-XP and AX-DVF-XP are color audio-video door stations for Aiphone’s AX-series, containing a standalone proximity card reader with embedded host controller. Capable of storing up to 5,000 sets of credentials (cards) and operating completely independent of an external host controller or PC, the AX-DV-XP and AX-DVF-XP are ideal for all installations where reliable, inexpensive and easy-to-manage access control is desired.
Note: Programming of the AX-DV-XP and AX-DVF-XP requires Aiphone’s XP-KIT Programming Starter Kit for -XP series standalone proximity card readers.
NAMES & FEATURES
AX-DVF-XP
PACKAGE CONTENTS:
1
2
NAMES & FUNCTIONS:
1. Camera 4. Speaker
2. Microphone 5. Call button
3 4
3. Name placard 6. Standalone Prox Reader / Controller
FEATURES:
Up to 5,000 credential storage (cards)
5
Standalone configuration without central ‘Host’ or personal computer
6
Night Lock function with contact output for controlling after hours access and alarm system mode
AX-DV-XP
Forced Entry alarm output for triggering external sounder or alarm system
Optional handheld Remote Programmer for advanced functionality
OPTIONAL ACCESSORIES:
AX-DV-XP or AX-DVF-XP
Vandal-resistant Door Station
Security Driver
Blank name
placard
Mounting screw &
anchor bolt pack
(AX-DV-XP only)
Semi-flush backbox & tamper-resistant bolts
(AX-DVF-XP only)
SBX-DVF-P – Surface-mount stainless steel
backbox (AX-DVF-XP only)
XC5T/9 – Blank User Card (Qty. 1) XRP3 – Handheld Remote Programmer XP-KIT – Programming Starter Kit,
contains: XRP3 – Qty (1) XC5T/9 – Qty (10) XMMC3/9 – Qty (1)
(Note: XP-KIT is required
for programming of
the AX-DV-XP / AX-DVF-XP!)
Page 2
MOUNTING & INSTALLATION
Installation Location:
Care should be taken when choosing the best location for mounting the AX-DV-XP / AX­DVF-XP. Do not install the video door station in any areas subject to direct sunlight or other strong direct lighting conditions; installation in such locations may cause reduced visibility and/or video quality while viewing from the master station.
AX-DV-XP AX-DVF-XP
6'1"
2'1"
20"
3'11"
5'
20"
AX-DV-XP AX-DVF-XP
3'1"
Mounting Height & Viewing Angle:
Because the AX-DV-XP and AX-DVF-XP contain a fixed-angle camera element, mounting height and placement relative to the entry should be taken into consideration. The recommended mounting height and corresponding viewing angle are shown, at left.
Physical Mounting Instructions:
1. AX-DV-XP – provide mounting box or wall opening
sufficient for both the CAT-5e cable (from the AX CEU) and the -XP series card reader wire pigtail (Fig. 1), noting the offset location of the reader pigtail (Fig. 2).
AX-DVF-XP – provide wall surface opening for rough-in backbox (supplied), using dimensions shown (Fig. 3). Note: if surface mount is required, use the Aiphone SBX-DVLF- (sold separately) .
2. Open the protective door and connect the CAT-5e cable (RJ45) from the AX CEU to the AX-DV-XP or AX-DVF-XP station, carefully routing the wire in one of the two possible directions, as shown (Fig.
2). Be careful to avoid damaging the wire jacket when securing the protective door.
3. AX-DV-XP – Secure the door station to the wall surface using the provided mounting screws and/or anchors, as
-XP Series Prox Reader Pigtail
shown (Fig. 1). Secure the vandal resistant chassis using the security driver (provided).
Figure 2
AX-DVF-XP – Secure the door station to
the backbox using the included security screws / driver (Fig. 3).
1/4"1-3/8"
Figure 1
Figure 3
3"
8-3/4"
4-1/2"
8-7/16"
1-25/32"
Pg. 2
Page 3
WIRING
Forced Entry Sensor Input
Request-Exit
(Egress) Input
Forced Entry
Trigger Out
Night Lock
Trigger Out
Strike
(See Note 4)
(See Note 2)
(See Note 4)
(See Note 3)
(See Note 1)
DC Power
Grey Green Grey / Pink Red / Blue Violet (Lock) Brown (Ground)
+
-
Red Black
White: Not Used Yellow: Not Used Pink: Not Used Blue: Not Used
12V DC
Power Supply
NOTES:
1. The ‘Lock’ output (Violet wire) is a normally-open solid-state contact rated at 30VDC / 1A. Only DC-powered locks can be connected directly to the reader. Locks requiring AC power, higher contact rating, or Normally-Closed
functionality should use an external 12VDC relay (Aiphone RY-18L or equivalent). Release duration is determined by the reader’s programming configuration (see the -XP Series Programming & Operation Manual).
2. The ‘Request-Exit’ input is used when triggering the reader’s internal contact output from an external contact source is desired (motion detector, egress button, intercom relay output, etc.). An input closure should be connected across the Green wire and Ground (Brown wire). Unlock events triggered by this input are also subject to the reader’s release duration (see the -XP Series Programming & Operation Manual).
3. When the Night Lock mode is active, a trigger will be provided across the ‘Night Lock Trigger Output’ (Red / Blue wire) and Ground (Brown wire). This can be used to integrate with external alarm systems for improved functionality.
4. The ‘Forced Entry Sensor Input’ (Grey wire) is designed to be connected to Ground (brown wire) in series with a magnetic door sensor (or equivalent normally-closed device) to allow the system to determine when the door has been either forced, or left open after an unlock event. When this sensor input active, an output trigger will be provided across the ‘Forced Entry Trigger Out’ (Grey / Pink wire) and Ground (Brown wire), for connection to an alarm system event input, sounder, or other desired device.
5. All device outputs (with the exception of the Violet ‘Lock’ output) provide a low current trigger output, and should not be used to drive anything greater than another device’s trigger input without an appropriate relay. All device inputs require only a contact closure across the respective wire and Ground (Brown wire).
6. The White, Yellow, Pink, and Blue wires are not used and should be trimmed to avoid possible shorting and system malfunction.
Note: Only information pertaining to the wiring of the -XP series card reader is shown in this manual. For programming
information, consult the -XP Series Programming & Operation Manual (included in the XP-KIT Programming Starter Kit). For AX series intercom configuration / connection informat ion, consult the AX series Installation and Operation Manual (included with the AX CEU).
Pg. 3
Page 4
SPECIFICATIONS
DIMENSIONS:
AX-DV-XP
AX-DVF-XP
PROGRAMMING:
See programming instructions included with the required XP-KIT Programming Starter Kit (sold separately).
Note: Do not attempt to program or use the AX-DV-XP / AX-DVF-XP door station without first reading the initialization instructions included with the XP-KIT Programming Starter Kit!
SPECIFICATIONS:
CARD READER:
Power Source: 12V DC Current Requirements: 40mA (Avg) Terminations: Color-coded pre-wired pigtail Operating Temperature: -10°~60°C / 14°~140°F Operating Humidity: 0-95% relative humidity
non-condensing
FCC WARNING:
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference. (2) This device must accept any interference that may cause undesired operation.
For proper regulatory compliance, the drain wire should be disconnected at the power supply end of the cable. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. The Reader is intended to be powered from a limited power source output of a previously certified power supply.
DOOR STATION:
Power Source: AX-series CEU Camera unit: CCD Camera Scanning line: 525 lines Min. illumination: 5 Lux at 1' or less Terminations: RJ-45 Operating Temperature: -10°~60°C / 14°~140°F Wiring Distance: 980ft w/ CAT-5e wire
Aiphone Communication Systems 1700 130th Ave. N.E. Bellevue, WA 98005 (425) 455-0510 FAX (425) 455-0071
TOLL FREE TECHNICAL SUPPORT:
(800) 692-0200
E-MAIL: tech@aiphone.com
AX-DV(F)-XP Instr.