AX vs KB, LEF, & NDR
System Features AX KB LEF/MY NDR
Number of Masters
Number of Doors
Communication Style
Master to Master Communication
Mullion Mount Audio Only Door Station
Access Control Connection
CCTV Control Integration
CO Line Transfer
Video Doors w/Embedded HID Readers
Video Output Connection
Video Type
Monitor Type
Number of Call Levels
Number of Talk Channels
Event Logging
Scan Monitoring
Foot Switch Connection
Headset Connection
Call-in Time-out
Installation Comparison
Wire Type
Conductor Quantity
Wire Method
Connection Method
Max. Distance
Programmable Features
Notes:
1. Requires custom progamming not supplied by AIphone
2. LEF System max. 11 doors and masters combined
Max. 8 Max. 5 Max. 112 Max. 2
Max. 120 Max. 3 Max. 102 Max. 100 (audio only)
PTT or VOX Handset PTT PTT or VOX Handset
Yes Yes Yes No
Yes Yes No No
Programmable relay output Relay output (multiple doors require adaptor) Relays required Relays required
1
None Relays required Relays required
RS-232
Yes (with adaptor) No No No
Yes No No No
BNC connector Bare wires Requires Adaptor N/A
Color Color B&W N/A
TFT TFT CRT N/A
2 1 1 1
2 1 1 1 per master
Yes No No No
Yes No No No
Yes No No No
Yes No No No
10-600 seconds, or infinite 45 Sec. Tone while call button Tone and LED until answered
is pressed, 20 sec. LED after released
AX KB LEF NDR
CAT-5e 18AWG Solid, PE insulation Multi-conductor shielded Multi-conductor shielded
2 ~ 8 2 ~ 4 2 ~ 30 2 ~ 9
Homerun Homerun to doors, looped between monitors Homerun or looped Homerun
RJ-45 Screwless terminals Screw terminals Screw terminals
980’ 650’ from Door, 330‘ to farthest monitors 330’ (video), 1,600’ (audio) 1,000’ (audio only)
Yes No No No