a
83096400
0896@
AIPHONE
\
HANDSET INTERCOM
f
yodels;
AT-406
AT-306
Set
Additional sub
INSTALLATION & OPERATION MANUAL
SYSTEM OUTLINE & COMPONENTS
AT-406 is a Handset Intercom set, allowing two-way calling & communication.
_-_____-__------------~~~~~~~
I
AT-206
2
n
Components available
l AT-406 Boxed set
l AT-406P Decorative boxed set (N/A in USA)
l AT-306 Add-on sub
(add’1
2 pcs max.)
AT-306
I
AT-306 AT-306
l
Power supply:
SKK-620 in USA or
l TAR-3 relay for external signalling device.
PS-GD,
or 4 pcs SUM-3(AA) batteries.
Powered by a separate 6V DC power supply.
NAMES & FEATURES
AT-206
master
Battery check
LED
CALL button
Battery
compartment
AT-306
sub
CALL button
n
’
I
I
I
I
I
I
I
I
I
I
I
I
I
n
Features
Package Contents
l Handset Intercom set (AT-406)
or Sub station (AT-306)
l Mounting bracket
l Packet of screws
l Installation
&
Operation Manual
2-handset communication system
suited for:
R.V. cab-to-camper, Boat deck-to-cabin,
Limo. chauffer to back seat, and
Restaurant kitchen to bar, etc.
l
Up to 3 subs
l Electronic call tone, not adjustable
l Front loading batteries
l Battery or DC powered
l External signalling device
PRECAUTIONS ON INSTALLATION & WIRING
n
Mounting
AT-406 set is designed for indoor use only. Do not install outdoors.
It must be used in wall-mounted applications only.
n
Wiring
AT-406 can be wired with 2 non-polarized wires. When add-on sub(s)
installed, connect in loop or home run. Keep audio wires
50cm,
away from any AC wiring, fluorescent lights, dimmer switches, etc.
n
External signalling device
Any particular station can be signalled by bell or light, while it rings.
Install TAR-3 relay powered by its
or
PS-6D).
own 6VDCpower supply (SKK-620
AT-306
is
20”
-l-
= Loading batteries
Slide down front battery cover. Place four SUM-3 (AA)
batteries into compartment. Observe polarity.
n
$$$j:~
"VA
0
._J!
ii!,
_l-J:
/L--J;
/I/\\
0
Battery LED indicator
1 . LED is brightly lit.
+
Batteries are powerful enough.
2. Becomes dim during use.
-+
Batteries are getting weaker.
3. LED is no longer lit.
-+
Batteries are exhausted. Replace all
four batteries with new ones.
r-l
WIRING
AT-206 AT-306 AT-306 AT-306
___---__--_____---------------
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
I
1
NP
I
I
__---____----__--------_-----J
1
,2’
,-,
NP
--
--2
I
I
-
1
I
I
I
I
I
I
I
I
I
I
I
I
I
NP: Non-polarized
m:
6V DC power supply.
SKK-620: (+) Red, (-) Black.
PS-6D:
(+) Red, (-) White.
MOUNTING
AT-206
AT-306
Mount the intercom on bracket, aligning at the marks. Pull down on
bracket, until it properly locks. Terminal section is on the back side.
Do not disassemble the unit. For surface wall cable run, outlet hole is
provided on the top or bottom of chassis.
OPERATIONS
Press CALL button to call other station(s)(max. 3 subs). It rings as long as CALL button is pressed. Communicate on handsets.
At conclusion, replace handset onto cradle. If not hung up, battery power is consumed.
*
External device, connected to a station, is activated as long as call tone rings on handset.
TECHNICAL PRECAUTIONS
*
Do not hold hook switch down while handset is off hook, as the call tone sounds very loud through handset receiver.
*
Do not connect AC wires to any terminal on any unit.
*
Do not use DC power supply when the batteries are installed.
*
Do not install AT-406 in places subjected to temperature/humidity extremes, dust, oil, chemicals, salt, etc.
*
Clean AT-406 with a soft cloth dampened with neutral household cleanser. Never use any abrasive cleaner or cloth.
SPECIFICATIONS
l
Power source:
l
Power supply:
l
Communication:
l
Wiring:
l
Wiring distance:
l Dimensions
4
Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of one
$
year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which
+
examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision
$
whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty.
$
This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation of
$
instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover
+
batteries or damage caused by batteries used in connection with the product.
s
This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone.
+
Aiphone will not be responsible for any costs incurred involving on site service calls.
~~~~~~~~~~~ff~~~~~99~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Aiphone Co., Ltd., Nagoya, Japan
Aiphone Corporation, Bellevue, WA, USA
AT-406-I (E) 0896E
&
weight:
(AT-406)
6V DC, 120mA. OA standby.
SKK-620 in USA or
Electronic tone rings opponnent station(s). Common talk system with handset.
2 wires parallel, non-polarized.
210H x 80W x 52D.
AT-206: 310g (0.68 Ibs.) approx.
AT-306: 280g (0.62 Ibs.) approx.
PS-6D
power supply. Or 4 pcs
8-1/4”H
x
3-1/8”W
x 2”D.
-2-
SUM-3(AA)
batteries.
G
Lgf~fiwm~~
HOME, BUSINESS, INDUSTRY.
Printed in Japan (E)
l
z
+
z
z
z
z
z
z