Aiphone AC-10F, AC-10S User Manual

AC-10S, AC-10F
Access Control Clavier à Codes rétro-éclairé Türcodemodul Control de acceso Codeklavier
FK1376
A
YS0108
Surface mount type Clavier saillie Aufputztyp Montaje en superficie Opbouwmontage
AC-10S AC-10F
Flush mount type Clavier encastré Unterputztyp Montaje empotrado Inbouwmontage
INSTALLATION & OPERATION MANUAL NOTICE D'INSTALLATION ET D'UTILISATION INSTALLATIONS- UND BEDIENUNGSANLEITUNG MANUAL DE INSTALACIÓN Y USO INSTALLATIE & GEBRUIKSHANDLEIDING
RECORD OF SETTINGS AND REGISTRATION DETAILS (Please make sure to write down your settings below.) AIDE MEMOIRE DES PROGRAMMATIONS ENREGISTREES (Faire en sorte de bien noter vos réglages ci-dessous.) VERZEICHNIS DER EINSTELLUNGEN UND REGISTRIERUNGSDETAILS (Bitte notieren Sie unten Ihre Einstellungen.) DATOS DE CONFIGURACIÓN Y DETALLES DE LOS REGISTROS (Asegúrese de apuntar los valores de ajuste abajo.) LIJST MET GEPROGRAMMEERDE INSTELLINGEN EN CODES (Zorg ervoor uw instellingen hieronder op te
schrijven.)
Master code Code maître Mastercode Código maestro Hoofdcode
Key illumination time Temporisation d'éclairage Tastenbeleuchtungszeit Tiempo de encendido de las teclas Verlichtingsduur klavier
Relay output time Temporisation des relais Relais Ausgabezeit Tiempo de salida Relé Relais outputtijd
Relay 1 Relais 1 Relais 1 Relé 1 Relais 1
Relay 2 Relais 2 Relais 2 Relé 2 Relais 2
sec/sek/seg
sec/sek/seg
sec/sek/seg
External output setting Paramétrage de sortie externe Externer Ausgang Ajuste de la salida externa Activering Alarmuitgang
ON EIN AAN
Lockout Blocage Eingabe-Sperre Bloqueo Blokkering klavier
ON EIN AAN
Auto-relock Auto-reverrouillage Automatische Neuverriegelung Re-bloqueo automático Automatische hersluiting
ON EIN AAN
Timer-linked unlocking Déverrouillage lié à l'horloge Timergesteuerte Entriegelung Desbloqueo conectado al temporizador
1 2 1&2
Tijdsgebonden ontgrendeling Operation tone
Bip de fonctionnement Signaltöne Tono de operación Zoemer klavier
ON EIN AAN
Registered User Code List / Liste des codes utilisateur programmés / Liste der registrierten Zugangscodes
Lista de códigos de los usuarios registrados / Lijst Codes Geregistreerde Gebruikers
group 1 / groupe 1 / gruppe 1 / grupo 1 / groep 1 group 2 / groupe 2 / gruppe 2 / grupo 2 / groep 2
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
OFF AUS UIT
OFF AUS UIT
OFF AUS UIT
OFF AUS UIT
1
English
PRECAUTIONS
General Prohibitions Prohibition to Dismantle the Unit General Precautions
WARNING
(Negligence could result in death or serious injury to people)
1. Do not connect any non-specified power source to the V, V terminals, and do not install two power supplies in parallel to a single input. Fire, damage to the unit, or system malfunction could result.
2. The unit is not explosion-proof. Do not install or use near gases or flammable materials. Fire or explosion could result.
3. Do not dismantle or alter the unit. Fire or electric shock could result.
4. Do not allow the wires or DC output terminals to be shorted. Fire or electric shock could result.
CAUTION
(Negligence could result in injury to people or damage to property)
1. When mounting the unit on a wall, install the unit in a convenient location, but not where it could be jarred or bumped. Injury could result.
2. Do not install or make any wire terminations while power supply is plugged in. It can cause electrical shock or damage to the unit.
3. Before turning on power, make sure wires are not crossed or shorted. Fire or electric shock could result.
4. Do not install the unit in any of the following locations. Fire, electric shock, or unit trouble could result.
* Places subject to dust, oil, chemicals, hydrogen sulfide
(hot spring).
* Places subject to moisture and humidity extremes,
such as bathroom, cellar, greenhouse, etc.
* Places where the temperature is quite low, such as
inside a refrigerated area or in front of air-conditioner.
* Places subject to steam or smoke (near heating or
cooking surfaces).
* Where noise generating devices such as dimmer
switches, invertor electrical appliances, are closeby.
GENERAL PRECAUTIONS
1. This product, being a control unit of door release, should not be used as a crime-prevention device.
2. This product is weather-resistant, but do not spray high-pressure water on it. Unit trouble could result.
3. The product becomes inoperative during power failure.
4. As to other manufacturer's devices, such as sensor, door releases, timer, used with this system, comply with the Specifications and Warranty conditions manufacturers or venders present.
English
Français Deutsch Español
Nederlands
CONTENTS
RECORD OF SETTINGS AND REGISTRATION DETAILS PRECAUTIONS …………………………………………… 2 PACKAGE CONTENTS …………………………………… 2 NAMES ……………………………………………………… 3 MOUNTING ………………………………………………… 3 MOUNTING/WIRING METHOD, WIRING DISTANCE
…1
…… 4
PACKAGE CONTENTS
AC-10S AC-10F
Unit
Mounting
bracket
Mounting
screws
Special
screwdriver
FUNCTIONS OPERATIONS ……………………………………………… 9 TECHNICAL PRECAUTIONS …………………………… 9 SPECIFICATIONS ………………………………………… 9 WARRANTY ………………………………………………… 9 TEMPLATE FOR AC-10S MOUNTING BRACKET (SCALE 1:1)
Operation
manual
SETTING UP ……………………………… 5
Unit
Flush mount
back box
Special
screwdriver
…42
Operation
manual
2
NAMES
98mm (3-7/8")
11.5mm (7/16")
3.5mm (1/8")
49mm (1-15/16")
42.5mm
(1-2/3")
55mm
(2-3/16")
68.5mm (2-11/16")
Cable inlet
64mm (2-1/2")
15mm (9/16")
t
12
English
3
FrançaisDeutschEspañol
4
MOUNTING
AC-10S
1.
Drill holes in the wall to match the size and number of screws.
2. Attach the mounting bracket to the wall using the mounting screws.
3.
Attach the unit to the mounting bracket using the special screwdriver and the special screw for mounting.
AC-10S
55mm (2-3/16")
Nederlands
4
1 LED indicator (Orange)
1
2
3
4
2 LED indicator (Green) 3 Keys (Yellow) 4 Special screws for panel mounting
AC-10F
1.
Detach the AC-10F panel using the special screwdriver supplied.
2. Attach the flush mount back box to the wall.
3.
Attach the panel to the flush mount back box using the special screwdriver and the special screws for panel mounting.
AC-10F
85mm (3-3/8")
Cable
Spare screw holes
1
WallWall
3
Click
2
Flush mount back box
When this unit is to be used with the JF-DV, please refer to the illustration below when installing it.
Please also refer to "TEMPLATE FOR AC-10S MOUNTING BRACKET(SCALE 1:1)"(page 42).
1. JF-DV unit
173mm (6-13/16")
2.
Positions for drilling holes
Please refer to the illustration below when drilling the holes. Make sure the cable inlet is within the shaded area shown in the illustration below.
3. Position of mounting bracket
Refer to the illustration below when attaching the mounting bracket.
Attach the unit to the mounting bracket by pushing it into the bracket. Tighten the screws to complete the installation.
( )
As there are drain holes at the bottom of the JF-DV unit, do not block the space between the JF-DV and the access control keypad.
100mm (3-15/16")
45mm (1-12/16")
4. Installation
3
98mm (3-7/8")
42.5mm
(1-2/3")
55mm
(2-3/16")
49mm (1-15/16")
49mm (1-15/16")
A hole for cable inle
5mm
(※)
(3/16")
MOUNTING/WIRING METHOD, WIRING DISTANCE
Automatic gate
or
Electromagnetic door lock
rminal names
Te
Back view of AC-10S
Electric door strike
Connection of Relay 1 only
Relay
2
Relay
2
Power supply
Power supply Between 12 and 24V AC
Between 12 and 24V DC
AD
Power supply
2
B
2
2
2
C
Request to
VV
Exampleofelectricdoor strikeconnection(N/O)
Request to
exit/entry
exit/entry
button 1
button 2
PB2PB1
Request to exit/entry button ・Timer
Minimum overload :100mV DC, 0.1mA or above
・ ・Contact capacity: 3V DC, 0.1A or above
Request to exit/entry button
Request to exit/entry button
Timer
Common Timer
TC
(Wiring distance)
Power supply
AC/DC12 ~ 18V
A
AC/DC18 ~ 24V
B
C
The connection distance will depend on the specifications of the electric door strike, relays or Electromagnetic door lock to be
D
connected. To determine the operating range, please refer to the specifications of each terminal.
User group1 relay 1 User group2 relay 2
N/C contact
NO1
Exampleofautomatic
gateconnection(N/O)
C1
N/O contact N/O contact
Relay 24V DC, 3A (resistive load) 1A (inductive load)
24V AC, 3A (resistive load) 1A (inductive load)
Minimum overload :5V DC, 100mA or above
(Less than)
-
- 300m (980')
NC1
Exampleofelectromagneticdoor
diameter 0.65 - 1.0 mm (22-18AWG)
100m (330')
300m (980') 300m (980')
N/C contact
C2
NO2
lockconnection(N/C)
NC2
English
Français Deutsch Español
Nederlands
C2
NC2
2
Power supply
VV
NP
Request to exit/entry button (push button, etc.)
TC
NO1
C1
NC1PB2PB1
NO2
Electric door strike
2
2
NP
NP
AC transformer
Relay 1: Automatic gate (N/O contact), Relay 2: Electric door strike (N/O contact)
TC
NO1
N.C
2
PB2
C1
NP
Power supply Rating
Between 12 and 24V AC Between 12 and 24V DC
For relay 1 Request to exit/entry button
For relay 2 Request to exit/entry button
Timer
VV
2
NP
2
NP
2
NP
2
NP
NO1
2
NC1 NO2
2
Automatic gate
Auto-relock/External out put by forced entry (sensor connection is required)
To setVJG
sensor (locally avallable) is required.
C
The request to exit/entry button for relay 2 cannot be used when the
"auto-relock" / "External out put by forced entry" function are set.
NC1
C1
NP
Automatic gate
C2
NC2PB2PB1
NP
NO2
AC transformer
"
auto-relock" / "External output by forced entry" function a
NO1
oror
C2
Electric door strike
C1
NC1 NO2N
Electromagnetic
2
door lock
NP
PS
Power supply
External output Only connecting to the terminal
of relay 2 is possible.
Alarm, Security
C2
4
FUNCTIONS SETTING UP
This section explains the settings of each function, including the master code for management, the user code for unlocking, the buzzer and the LEDs. About the setting mode:
Enter master code twice to switch to the setting mode, and enter the following setting code to perform the settings for the desired function. After settings have been made, enter the following setting codes to continue the setting
English
operation. Press
Setting the code length
Change the length of the master code and the user code.
FrançaisDeutschEspañol
)They both must be the same length.
Setting the master code
Enter a master code using between 4 and 6 digits (alpha or numeric) to switch to the setting mode.
) The number of digits in the code can be set by setting the code length.
Setting the code for user group 1
Set the unlocking code for user group 1.
) The number of digits in the code can be set by setting the code length.
Setting the code for user group 2
Set the unlocking code for user group 2.
) The number of digits in the code can be set by setting the code length.
Setting the key illumination time
Set the length of time that the keys will be lit up after they are pressed.
Setting the relay 1 output time
Set the output time of relay 1.
Setting the relay 2 output time
Set the output time of relay 2.
Reset Settings
Nederlands
Return all the settings to their default values.
External output setting
The alarm or security system connected to the terminal of relay 2 will be activated when the "Lockout" * or the forced entry* is carried out. * "Lockout": Refer to VIII below. *Forced entry: This function is linked with the door open/close sensor (N.C.) which is connected to PB2 and C, and carried out when opening the door without activating this unit. (For example, entry in an improper manner, manual unlock, etc.)
) If there is a way to open the door without activating this unit, such as
manual unlock, do not make the external output setting for the forced entry.
Lockout
If several incorrect access codes are attempted, the code input function is disabled for a programmed period of time.
· When "Lockout" is activated, the LED (Orange) indicator and the keypad blink, and the buzzer sounds for 3 seconds. This is just a sound to inform you that the function has been activated. It is not a warning sound. If you want a warning to be sounded, please use the external output function to activate a commercially-available alarm device.
· The unlock function will work when the request to exit/entry button is pushed, even while the "Lockout" function is operating.
Auto-relock (Anti-tailgate)
After the door has been linked to the door open/close sensor (N/C), and unlocked, it will relock itself one second after being closed, thus preventing the entry of an unauthorized third party.
Timer-linked unlocking setting
The system can be set to unlock the door by pressing the key within the set time and linking it to the external timer (N/O). The operations for the LEDs and the buzzer after unlocking are the same as those used to perform user code unlocking. When the door is linked to the timer, unlocking can be performed using the user code and the request to exit/entry button. When latch output is performed for the relay settings, the relay turns ON/OFF
every time the
Operation tone settings
Set the tone heard when the keypad is being used to ON/OFF.
• The setting can be saved even when the power is off.
• The system cannot be switched to the setting mode while the relay is unlocked.
• When the setting mode has been activated and no operations are performed for approximately 120 seconds, the system will exit the setting mode. (If a key is pressed during that time, the timer will start over.)
• Neither the request to exit/entry button nor the timer-linked unlocking user code cannot be performed while the setting mode is activated.
• The volume (the check tone, operation tone, etc.) from the main unit may become lower according to the mounting status.
1
5
: When the auto-relock is used, the request to exit/entry button for relay 2 cannot be used. The output of relay 2 is
only possible when user code unlocking is performed.
to exit the setting mode.
Setting items Allowable setting range Default value
)1
key is pressed.
Setting code
4, 5, or 6 digits 4 digits
1
1234
Valid keys: 0 - 9, A, B
Number of codes: 60
-
Valid keys: 0 - 9, A, B
Number of codes: 40
-
Valid keys: 0 - 9, A, B
Illumination time: 10 to 99
10 Sec.
seconds, or continually lit Output time: 1 to 99
3 Sec.
seconds, or latched Output time: 1 to 99
3 Sec.
seconds, or latched
--
· OFF
OFF
· During Lockout
· During forced entry output
·
During lockout and forced entry output
ON/OFF
OFF Invalid number of times: 10 to 99 times Invalid time: 10 to 99 seconds
ON/OFF OFF
Linked relay: relay 1
Linked relay: relay 1
relay 2 relay 1 and 2
0 key illumination: OFF
0 key illumination: ON/OFF
ON/OFF ON
key can be operated, and unlocking using the
-
-
Orange (L) Green (R)
The result of each operation is indicated by the lighting up of the LED indicators on the upper section of the unit, and by the sounding of the buzzer.
English
Input the master code twice. (Default: )
Setting the code length
(Default: 4 digits)
Input the setting code.
Illumination Blinking
Bleep
Setting the master code
(Default㧦1234)
Input the setting code.
Illumination Blinking
Bleep
(orange)
Illumination
(green)
Blinking
Setting the code
group 1
00 - 59 60 - 99
Inputting of user number (ex.: 01)
When a user code that has already been set is selected
Blinks
Illumination
Bleep
twiceBlinkingIllumination
Bleep,
Bleep
Inputting of user number (ex.: 60)
Bleep, Bleep
group 2
Bleep
When a user code that has already been set is selected
Blinks twiceBlinkingIllumination Illumination
Bleep,
Bleep
Français Deutsch Español
Nederlands
Inputting of code length (ex.: 5 digits) 4, 5, or 6 digits
Inputting of new master code (ex.: 4321)
Inputting of code (ex.: 1006) * Numbers 0
-
9 and the
letters A and B can be used
Illumination Blinking
Beep
-
When the key is pressed, the green LED lights up, the buzzer beeps twice, and the system exits the setting mode.
Illumination Blinking
Beep
Illumination
Blinking Illumination Blinking
Beep Beep
Inputting of code (ex.: 04B2) * Numbers 0
letters A and B can be used
(If the key is included in the user code and the master code, the system does not exit the setting mode.)
- You can continue the setting up operation by entering an arbitrary setting code.
· The set code will be saved in memory, even if the code length is changed. However , c odes of differ ent l engths cannot be used.
· W hen the code length has been changed, the master code r eturns to the default val ue (if the num ber of digits in the code i s 4, 5, or 6, the master code i s 1234, 12345, or 123456 respectively).
· Please note that the shift to the setting mode can be performed during timer-linked unlocking. However, if " " is included in the master code, the door will be unlocked, and the shift to the setting mode will not be able to be performed.
· The same code cannot be set for both the user code and the master code (the previously set code has priority).
· Do not set simple codes, such as 1111.
· We recommend that you change the default master code.
· To make the set user code invalid, press 0000 (when 4 digits are used), 00000 (when 5 digits are used), or 000000 (when 6 digits are used). Code numbers which contain only "0" cannot be set as user codes.
· As the factory pre-setting master code is 1234, 1234 (when 4 digits are used), 12345 (when 5 digits are used), and 123456 (when 6 digits are used) cannot be set as user codes.
· Do not set simple codes, such as 1111.
* The same code cannot be set for both the user code and the
master code. The previously set code has priority.
Indicator goes out
-
9 and the
Blinking
Bleep,
Bleep
6
Input the master code twice. (Default : )
(orange)
Illumination
(green)
Blinking
Bleep, Bleep
English
Setting the key illumination time
FrançaisDeutschEspañol
Inputting of illumination time
Nederlands
(ex.: 20 seconds)
10 - 99 Indicator is lit up at all times: 00
(Default: 10 Sec.)
Input the setting code.
Illumination Blinking
Bleep
Illumination Blinking
Beep
Setting the relay output time
(Default: 3 Sec.)
When setting relay 1When setting relay 1 When setting relay 2When setting relay 2
Input the setting code. Input the setting code.
Illumination Blinking
Bleep
Inputting of relay output time (ex.: 99 seconds)
01 - 99 Latched () : 00
Illumination Blinking
Beep
Illumination IlluminationBlinks three times Blinking
Reset Settings
Input the setting code.
Illumination Blinking Illumination Blinking
Bleep Bleep
Bleep, Bleep, Beep
(Default: OFF)
Input the setting code.
During lockout
entry output
entry output
During lockout
and forced
and forced
entry output
entry output
During
During
Lockout
Lockout
During forced
During forced
External output setting
OFFOFF
Beep
-
When the key is pressed, the green LED lights up, the buzzer beeps twice, and the system exits the setting mode.
Indicator goes out
(If the key is included in the user code and the master code, the system does not exit the setting mode.)
- You can continue the setting up operation by entering an arbitrary setting code.
· () If the latched status has been set and the door is unlocked, it will not be locked again until the user code is entered (or the request to exit/entry button is pressed, or the key is pressed while timer-linked unlocking is set).
· When the door is unlocked during relay outputting (including when latched), the system cannot be switched to the setting mode.
· If the power is tur ned off and the , , and keys ar e pressed si m ul taneously w hile the unlock 1 input status is active (shor t circuit between ter m inals PB1 and C), the settings can be returned to their default values by turning the power back on and pressing the , , and keys simultaneousl y for 3 seconds.
· W hen setti ng the exter nal output, do not set the r elay 2 output to be latched.
Blinking
Bleep,
Bleep
7
Input the master code twice. (Default : )
(orange)
Illumination
(green) Blinking
Bleep, Bleep
English
Lockout
(Default: OFF)
Input the setting code.
Bleep Bleep
OFFONOFF
Illumination Blinking Illumination Blinking
Beep
Inputting the number of operations (ex.㧦10 times) 10 -99
Illumination Blinking
ON OFFOFF ONON
Bleep
Bleep
Auto-relock
(Anti-tailgate)
(Default: OFF)
Input the setting code.
Timer-linked unlocking setting
(Default: relay 1, OFF)
Input the setting code.
Illumination BlinkingIllumination BlinkingIllumination Blinking Illumination Blinking
BleepBleep
Relays 1 and 2
Relays 1 and 2
are both linked
are both linked
0 key illumination OFF
0 key illumination OFF
while timer is on
while timer is on
Only relay 1
Only relay 1
is linked
is linked
Illumination BlinkingIllumination Blinking Illumination Blinking
Illumination Blinking
Only relay 2
Only relay 2
is linked
is linked
BleepBeep
0 key illumination ON
0 key illumination ON
while timer is on
while timer is on
Beep
Operation sound settings
(Default: ON)
Input the setting code.
Operation
Operation
tone OFF
tone OFF
Operation
Operation
tone ON
tone ON
Beep
Français Deutsch Español
Nederlands
Inputting length of time in "Lockout" mode (Ex.: 10 seconds) 10 - 99
Illumination Blinking
Beep
-
When the key is pressed, the green LED lights up, the buzzer beeps twice, and the system exits the setting mode.
Indicator goes out
(If the key is included in the user code and the master code, the system does not exit the setting mode.)
- You can continue the setting up operation by entering an arbitrary setting code.
· When the relay 1 output time is set to latched output, the auto-relock function is disabled.
· When the auto-relock function is turned on, the unlock function of the request to exit/entry button of relay 2 is disabled.
· If the 0 key illumination function is turned on while the timer is on, only the 0 key illumination will light up, even if the "key illumination time setting" is set to "Indicator is continually lit".
Blinking
Bleep,
Bleep
8
Loading...