A83090 1201 A
NEM/C, NEM-A/C Series
WEATHER-RESISTANT SUB STATION
Model:
NE-JA
INSTALLATION & OPERATION MANUAL
PRECAUTIONS ON INSTALLATION & WIRING
WARNING Negligence could result in death or serious injury.
1. When exisitng chime wires are used, be sure to locate and disconnect the bell transformer.
Unit damage or electric shock could result. Ask qualified personnel.
2. Do not change or alter NE-JA. It can cause fire or electric shock.
3. The NE-JA is weather-resistant, but do not spray water directly on NE-JA station to
prevent electric shock.
4. Make sure wires are connected properly before plugging in power supply. Fire or electric
shock could result.
GENERAL PRECAUTIONS – mark indicates
caution statement (incl. danger and warning), which
is specifically shown inside.
GENERAL INSTRUCTIONS – mark indicates
contents which demand a specific action shown
inside or attached.
GENERAL PROHIBITIONS: – mark
indicates contents which prohibit a specific
action shown inside or attached.
DISMANTLE PROHIBITIONS
1 SYSTEM OUTLINE & COMPONENTS
The NE-JA is weather resistant sub station designed for use with the
NEM system. The unit is equipped with an option for an external output
contact closure when the sub station places a call (relay required). The
NE-JA flush mounts in a 2-gang box, and has a stainless steel cover.
2 wires homerun
PS24
2 2 2
NE-JA NE-JA NE-JA
NBY-4A
NEM master
External device
PS24
2
RY-PA
: PS-24E. PS-2410A (USA; for up to 20 subs)
11
1
Components
NEM-n/c : Press-to-talk master
NEM-nA/C : Press-to-talk or VOX handset
master (n=10, 20, 30 & 40)
Other models;
NEM masters with 50 ~ 120 calls
Important:
It is suggested to connect an NE-JA('s) in a
1
1
1
homerun manner, particularly when corridor
light is installed. To secure brightness of the
corridor light, use thicker wire possible and limit
wiring within 60% range of the Distance Chart
on Page 2.
When an NE-JA('s) is connected to a common
E line, do not exceed two NE-JA's per E line, as
the calls will not be fulfilled if placed from three
NE-JA's (or more) at the same time.
NAR-2A
2 NAMES & FEATURES 3 MOUNTING
Speaker/mic.
Front cover
(Stainless steel)
2 screws
(supplied)
NE-JA
Package Contents
Door station (NE-JA)
Packet of screws
Installation & Operation
Manual
2-gang box
Stainless
steel cover
Cover mount screws
Weather-resistant door station style
Two-gang flush-mounting with stainless
steel cover
LED staying lit while master is ringing
Master ring LED
CALL button
2 front screws
- 1 -
83.5mm
(3-5/16")
1. Loosen 2 screws on front cover.
2. Connect wires on back of NE-JA.
3. Mount NE-JA unit on 2-gang box.
4. Reattach front cover on NE-JA.
4 WIRING DIAGRAM
Homerun wiring of NE-JA's
NEM master
(NEM-40A/C)
1
NE-JA
1
NE-JA
(w/dry closure
output)
NE-JA
(w/corridor
lamp)
2
2
1
2
40
E
PS24
+
-
Dry closure output
for duration of call-in
PS24
H
Blk Blk
RY-PA
Yel
(2)
: PS-24E. PS-2410A (USA. for up to 20 subs)
3
4
Blu
NBY-4A
Blu
Blu Blu
NAR-2A
5 OPARATION
1. To place a call, press call button on door station once. The
call-in tone and LED will be lit on the master station,
remaining activated until answered. The LED on the door
station will be lit to indicate a call has been placed.
2. When the master station answers, a brief pretone will be
heard. Speak into the door station hands free.
3. When the call is completed, the person at the master will
press OFF button, and communication will be cut off. The
person at the remote station does nothing.
4. If a corridor lamp is included, the lamp will be lit from the
time the call is placed until answered.
5. If a relay is included at the remote station to provide an
extra dry closure, the closure will be activated from the
time the call is placed until answered.
1
2
3
4
GRN/BLK
jumper
Cut the jumper
when corridor
lamp is installed
at sub. Secure
insulation.
7 SPECIFICATIONS
Power Source:
Speaker:
Call Annunciation:
Communication:
Mounting:
Wiring:
In USA only;
Wiring Distance:
2 wires homerun
Diameter 0.65mmø 1.0mmø AWG 22AWG 18AWG
Distance 110m 270m Distance 360' 880'
1 wire common +1 per sub
(applicable for max. two NE-JA's)
Diameter 0.65mmø 1.0mmø AWG 22AWG 18AWG
Distance 70m 170m Distance 230' 560'
NOTES:
1. The NE-JA can have the external closure
option, the corrindor lamp, or both
connected.
2. When including a corridor lamp, cut
GRN/BLK jumper, and connect NBY-4A to
terminals 2 and 3 on sub station.
3. When using the extra contact, connect
input (coil) of relay to H of master and
terminal 4 at sub.
4. The dry closure will stay activated from the
time the call is placed until it is answered
at the master station. The RY-PA is a 12V
DC, "normally open" relay. If a "normally
closed" contact is required, the RY-PA can
be changed to N/C, or a standard 12V DC,
N/C relay can be used.
TERMINAL DEFINITIONS:
1, 2: Call-in and communication
3: Corridor lamp activation
4: External relay activation
Supplied by master station
20 ohms
Pressing call button at remote latches
call at NEM master until answered.
Hands free at sub. Master is push-to-talk
or VOX handset.
NE-JA flush mounts in 2-gang electrical
box with stainless steel cover over unit.
2 conductors homerun; or 1 common plus 1
individual per sub, looped through each sub.
Shielded cable is recommended.
Use Aiphone #822202 or #821802 for
homerun wiring, #822206 for up to 5
stations on each run, or #822210 for up to
9 stations on each run.
6 TECHNICAL PRECAUTIONS
Caulking seals:
Do not apply any caulking seals around
Dimensions:
(H x W x D; mm)
115(4-1/2") x 116(4-1/2") x 10(1/2") (outer depth)
sub station. Water drainage holes on
Cleaning:
bottom will help water or moisture to
dissipate.
Clean NE-JA with a soft cloth dampened
with neutral household cleaner and cloth.
Do not spray high-pressure water on sub
station.
RY-PA
Coil Rating:
Contact Rating:
116 (4-1/2")
12V DC, supplied by H terminal of master
110V AC, 1A, or up to 24V DC, 1A
115 (4-1/2")
10 (1/2")
WARRANTY
Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period
of one year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective
upon which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make
the final decision whether there is a defect in materials and/or workmanship; and whether or not the product is within the
warranty.
This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation
of instructions furnished, nor extended to units which have been repaired or altered outside of the factory.
This warranty does not cover batteries or damage caused by batteries used in connection with the unit.
This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone.
Aiphone will not be responsible for any costs incurred involving on site service calls.
AIPHONE CO., LTD., NAGOYA, JAPAN
AIPHONE CORPORATION, BELLEVUE, WA, USA
AIPHONE EUROPE N.V., ANTWERP, BELGIUM
NE-JA-I (E) 1201A
- 2 -
Printed in Japan (E)