Aiphone 13710 User Manual

AX Series
Security and Communication System
Architectural and Engineering
Specifications
Aiphone AX Series 13710 (28 13 00) - 1
Aiphone AX Series 13710 (28 13 00) - 2
Aiphone Corporation February 2007
1700 130th Avenue NE Bellevue, Washington 98005 Toll Free (800) 692-0200 Phone (425) 455-0510 Fax (425) 455-0071 Website www.aiphone.com E-mail info@aiphone.com
Product Guide Specification
Specifier Notes: This product guide specification is written according to the Construction Specifications Institute (CSI) 3-Part Format, including MasterFormat, SectionFormat, and PageFormat, as described in The Project Resource Manual—CSI Manual of Practice, Fifth Edition.
The section must be carefully reviewed and edited by the Architect or Engineer to meet the requirements of the project and local building code. Coordinate this section with other specification sections and the Drawings. Delete all “Specifier Notes” after editing this section.
Section numbers are from MasterFormat 1995 Edition, with numbers from MasterFormat 2004 Edition in parentheses. Delete version not required.
SECTION 13710 (28 13 00)
SECURITY AND COMMUNICATION SYSTEM
Specifier Notes: This section covers Aiphone Corporation “AX Series” integrated security and communication system. Consult Aiphone Corporation for assistance in editing this section for the specific application.
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Integrated security and communication system.
1.2 RELATED SECTIONS
Specifier Notes: List numbers and titles of sections with work directly related to this section.
A.
1.3 REFERENCES
Aiphone AX Series 13710 (28 13 00) - 3
Specifier Notes: List standards referenced in this section, complete with designations and titles. This article does not require compliance with standards, but is merely a listing of those used.
A. ISO 9001:2000 – Quality Management Systems – Requirements. B. TIA/EIA 568 – Commercial Building Telecommunications Cabling Standard.
1.4 SYSTEM DESCRIPTION
Specifier Notes: Edit the system description as required for the project. Consult Aiphone Corporation for more information.
A. Components:
1. Door stations.
2. Master Stations: Connect a maximum of seven 16-call add-on selectors Model AX-16SW.
3. Central Exchange Units (CEU): Connect a maximum of 3 add-on exchange units Model AX-320C.
4. Power supply.
5. Other External Connections:
Specifier Notes: Access control system and CCTV system may require custom software programs, not provided by Aiphone Corporation.
a. Access control system. b. CCTV system. c. CO line adaptor. d. Video output. e. PC.
B. Capacities:
1. Door Stations: Maximum 120 stations with 1 CEU Model AX-248C and 3 add-on exchange units Model AX-320C.
2. Master Stations: a. Maximum 4 stations with CEU Model AX-084C. b. Maximum 8 stations with CEU Model AX-248C.
3. Power Supply: a. Model PS-2420UL: 24 V DC, 2 A. b. For Audio: 1. c. For Video: 2.
4. Number of Talk Paths: 2.
5. Number of Video Paths: 2.
6. All Call: 1, to master stations only.
7. Video Monitor: 2, same as talk paths and video paths.
8. Scan Monitor: 1.
C. Calling Master Station from Door Station and Communicating:
1. Priority Levels for Calls from Door Stations: a. Normal. b. Priority.
Aiphone AX Series 13710 (28 13 00) - 4
2. Press door station CALL button.
3. Calling tone rings on master station (for normal call, intermittent tremolo sound; for priority call, rapid intermittent tremolo sound) and selector button LED for individual door station flashes (double-flash for priority call). If door station has camera, video from door station shall be displayed on master station monitor. Call tone continues to ring until answered or is timed out (based on setting). You can stop calling tone by pressing OFF button.
4. If you press individual door station selector button, LED stops flashing and stays lit and you can talk hands-free to that station. If only TALK button is pressed to answer call, hands-free communication initiates with door station at highest priority call. Talk LED lights when you talk and goes off as you listen to caller.
5. Press OFF button again to end communication. Call also ends automatically when set talk limit is reached.
6. If you hold down TALK button for a minimum of 1 second, communication switches to press-to-talk mode. Hold down TALK button to talk and release to listen to caller. You cannot switch back from press-to-talk communication to hands-free communication.
7. If other master station presses selector button of in-use door station or in-use master station, busy signal is heard at master station.
8. Microphone is muted while you hold down privacy button on master station while in communication.
9. You can connect footswitch and use it the same manner as TALK button.
10. Master station can display calls up to 8 stations at the same time. If there are more than 8 incoming calls, they will be displayed in order of priority and time of call.
11. You can adjust calling tone, transmit volume, and receive volume with volume controls at bottom of master station.
12. You can use a headset (not included in system) instead of built-in master station’s speaker and microphone.
D. Calling Master Station from Another Master Station and Communicating:
1. Press individual selector button of master station.
2. Pre-tone sounds both master stations and starts hands-free communication. Talk LED lights when you talk and goes off as you listen to caller.
3. Press OFF button to end communication. You can end call from either master station. Call also ends automatically when set communication end time is reached.
4. If called master station has privacy mode set (privacy settings button is lit), communication is only 1-way, from calling master station to called master station, and nothing can be heard from called master side. Press TALK button on called master station for a minimum of 1 second. Press-to-talk communication starts. Hold down TALK button to talk and release to listen to caller.
5. You cannot call master station while it is communicating. You will hear a busy signal.
E. Privacy (PRIV) Function:
1. To make master into privacy mode (prevent monitoring from other stations), press privacy button (LED lights up).
2. To cancel privacy mode, press privacy button again (LED goes out).
3. Privacy setting cannot be changed while in communication.
F. CO Line Cal l from Door Station and Communication:
1. If CALL button is pressed at door station while CO Transfer feature is set (with CO Transfer button lit), call tone rings on master station (for normal call, intermittent tremolo sound; for priority call, rapid intermittent tremolo sound) and selector button LED for individual door station flashes (double-flash for priority call). At same time, telephone call is placed to programmed CO line number.
Aiphone AX Series 13710 (28 13 00) - 5
2. You can communicate with door station from telephone.
3. You can end communication at telephone. Communication also ends automatically when set talk time limit is reached. About 10 seconds before end of call, you will hear alarm sound on telephone.
4. Maximum duration for CO line call is 300 seconds, even if call timer is set to “Infinite”.
5. Using this function requires Viking Electronics, Inc. “K-1900-5 Hot-Line Pulse Dialer”.
6. If there are multiple calls, call from door station with highest call priority is transferred.
7. Answering at any master station during CO transfer feature will stop CO transfer.
8. There are no functions, such as for door release and dial-in, from telephone.
G. All Call (Normal Master Station Paging):
1. When you press ALL CALL button on master station, all individual master station selector button LEDs flash slowly. You can clear undesired master station from All Call by pressing individual master station selector button with flashing LED, which will turn off LED. Pressing that button again makes that master station part of All Call again and makes LED flash.
2. If you press TALK button, send LED lights up and all individual master station selector buttons stop flashing and stay lit. Pre-tone sounds on target master stations and they can be talked to. At this time, you cannot hear audio from other master stations.
3. Press OFF button to end. You can end call for individual master station by pressing its OFF button.
4. All Call announcements do not go to master stations that are in use.
5. During All Call, if you press individual master station selector button on calling master station or press individual master station selector button or TALK button on 1 of the other master stations, communications switch to hands-free between master stations.
6. There is no function for hands-free reply from called master station during All Call mode.
7. If you press down ALL CALL button but do not start talking within 30 seconds, system goes back to standby mode. You can also return to standby by pressing OFF button.
H. All Call (Priority Master Station Paging):
1. When you press ALL CALL button on master station, all individual master station selector button LEDs flash slowly.
2. If you press ALL CALL button again, flash rate increases. You can clear undesired master station from All Call by pressing individual master station selector button with flashing LED, which will turn off LED. Pressing that button again makes that master station part of All Call again and makes LED flash.
3. If you press TALK button, TALK LED lights up and all individual master station selector buttons stop flashing and stay lit. Pre-tone sounds on all master stations and all can be called. At this time, you cannot hear audio from other master stations.
4. Press OFF button to end. You can end call for individual master station by pressing its OFF button.
5. Communication of master station being used is cancelled and All Call takes priority. Before communication of master station being used is cancelled, you hear cancel warning sound.
6. During All Call, if you press an individual master station selector button on calling master station or press individual master station selector button or TALK button on one of the other master stations, communications switch to hands-free between those two master stations.
7. There is no function for talk back from master station receiving an All Call announcement.
8. If you press down ALL CALL button but do not start talking within 30 seconds, system goes back to standby mode. You can also return to standby by pressing OFF button.
Aiphone AX Series 13710 (28 13 00) - 6