Read and retain carefully for as long as the product is being used. It contains vital information on the operation and installation of your
Alarm Controller. The booklet should be regarded as part of the product.
If you are just installing the unit, the booklet must be given to the householder. The booklet is to be given to any subsequent user.
3. House Coding ........................................................................................................................................
8. Getting your Alarm Controller Serviced .....................................................................................
9. System Diagnostics ............................................................................................................................
10. Contact Us ...........................................................................................................................................
2
.
Page
3
6
8
13
16
17
18
19
20
24
1. Overview
FunctionDescription
TestAll the Alarms can be tested from a centralised location
LocateThis will silence all the Alarms in the system except the one sensing Fire or CO
SilenceThis will silence the source Alarm(s)
Fire IndicatorIndicates that a Fire Alarm has been activated
CO IndicatorIndicates that a CO Alarm has been activated
EOL IndicatorIndicates that the Alarm Controller battery has reached its end of life (EOL)
Memory
The memory feature only works with some RadioLINK Alarms Contact us or visit our website for details.
The memory feature is confined to the system diagnostic mode and is not visible to the end user.
Congratulations on purchasing the single button Alarm Controller for RadioLINK Fire and Carbon
Monoxide (CO) Alarm systems. The Alarm Controller tests and controls Fire, CO and combined (Fire + CO)
RadioLINK Alarm systems.
Alarm Controller functionality
3
Indicator
Light
Segments (4)
Test /
Control Button
4
Fire
Low Battery
Indicator
Fire / CO Alarm Controller
CO
Indicator
Front View of ControllerRear View of Controller
OFFON
POWER H.CODE
MODE
House Code
Button
On / Off
Switch
System
Diagnostics
Mode
Button
5
2. Installation
Install the Alarm Controller mounting plate at an accessible point on the
wall 1.4m +/- 0.2m from floor level. Consider an alternative location if
the controller will be operated by a disabled person.
Also consider security and chose a location where it will not be accidently
or otherwise operated.
Turn on the system by sliding the switch to the on position & check the
power up sequence.
A video of the Alarm Controller installation, house coding & operation is
available on our website - see ‘Contact Us’ section.
6
OFFON
POWERH.CODE
MODE
Power up sequence
FIRE, BATTERY & CO indicators flash
Each individual segment lights up red
Each individual segment lights blue
Each individual segment lights green
After power up sequence all lights will go off to indicate standby mode.
7
3. House Coding
WARNING
It is essential to House Code the Alarm Controller to all the other
RadioLINK Alarms and devices in the system to ensure they will not
communicate with nearby systems. Failure to house code the system
may also result in a system malfunction.
Press and hold the House Code button (H CODE) on the back of the
controller until all segments light up blue, then release. The segments
will flash rapidly for a moment on entering house code.
House code all other RadioLINK Alarms and devices in the system.
Consult the instruction manuals on how to house code the Alarms and
devices. It is essential that each individual alarm / device is put into
house code mode in it’s actual location.
8
OFFON
POWERH.CODE
MODE
Fire / CO Alarm Controller
Return to the Alarm Controller and check that all segments are
flashing blue. The number of flashes should equal the number of
RadioLINK Alarms and devices in the system. A system with 3 x Smoke
Alarms, 1 x CO alarm and 1 x Alarm Controller will result in 5 blue
flashes. It may take up to 10 minutes before all 5 flashes are seen.
The flash pattern will repeat every 5 to 10 seconds while the Alarm
Controller remains in house code.
If it fails to flash the correct number of times, then consult the
‘Troubleshooting the RadioLINK’ section of this instruction manual.
Now, walk around the house to verify that all the other RadioLINK
Alarms and devices are giving the correct amount of flashes.
If any of these fail to flash the correct number of times, then consult
the ‘Troubleshooting the RadioLINK’ section of this instruction
manual.
Fire / CO Alarm Controller
9
To complete the commissioning, the system must exit house code
W
Fire / CO Alarm Controller
MODE
POWERH.CODE
OFFON
mode.
The units will automatically exit house code after 30 minutes. Once
coded the system will not communicate with any other RadioLINK
Alarms and devices outside the house coded group.
To manually exit house code press the house code (H CODE) button on the
back of the Alarm Controller. When all the segments light up blue, release
the button. This unit will then send an exit house code signal to all the
other RadioLINK Alarms and devices to exit house code.
After a short period the blue light will turn off and the system will return
to standby mode (normal). Depending on the number of RadioLINK
Alarms and devices in the system this period could vary from 5 to 20
seconds.
If you choose to make the Alarm Controller tamper proof remove the
pip (plastic post) using a pliers or similar tool.
Do not do this until the house coding procedure has been completed!
10
PO
ON
MODE
Slide the Alarm Controller onto the mounting base on the wall.
Check that the RadioLINK system is working by pressing the button on
the Alarm Controller until the TEST segment lights blue. This indicates a
RadioLINK test signal has been activated.
All the Alarms in the system will sound for a short period and then stop.
If the test fails, consult the ‘Troubleshooting the RadioLINK’ section.
Fire / CO Alarm Controller
Fire / CO Alarm Controller
11
Reset the house code
Sometimes in order to resolve an RF communication issue, e.g. Alarms have to be relocated, it may be
necessary to reset and house code all RadioLINK Alarms and devices in the system again.
To reset the Alarm Controller press and hold the house code button.
All segments will flash blue briefly and then go solid. After 5 seconds
approx. the segments will start flashing blue. At this point release
the house code button. The Alarm Controller has now been reset.
To reset the other RadioLINK Alarms and devices in the system
consult the appropriate instruction manuals.
12
OFFON
POWERH.CODE
MODE
Fire / CO Alarm Controller
4. Operation
Fire / CO Alarm Controller
Fire / CO Alarm Controller
Frequent testing of the system is advised to ensure its continued and safe operation.
Guidelines and best practices for testing are as follows:
1. After the system is installed.
WARNING
Testing the alarm system
Press and hold the button on the Alarm Controller until the TEST segment lights
up blue. When all the alarms in the system are sounding release the button. The
alarms will stop sounding after a period and the TEST segment will flash blue to
indicate the test has been completed.
2. Once weekly thereafter.
3. After prolonged absence from the dwelling (e.g. after holiday period).
4. After repair or servicing of any of the systems elements or household electrical works.
13
Fire / CO Alarm Controller
Walk round test (optional)
Fire / CO Alarm Controller
Remove the Alarm Controller from its cradle. If the unit has
been tamper proofed you will need to release the latch with
Fire / CO Alarm Controller
a screwdriver.
With the Alarm Controller in your hand press and hold the
button. Walk around the house and verify that each Alarm
is sounding. When testing is complete release the button
and replace the controller in its cradle. If the test fails go to
‘Troubleshooting the RadioLINK’ section.
When the alarm system sounds
If there is a fire, immediately evacuate the premises and telephone the fire brigade.
If the source of the alarm is not obvious go to the Alarm Controller and check to
see which indicator is illuminated, Fire or CO.
If the CO indicator is flashing, open doors & windows while evacuating the premises.
Contact the appropriate authorities to report the incident.
14
Locate the source Alarm(s)
If the FIRE indicator is lighting and there is no obvious fire, press
the button. The LOCATE segment will change from red to blue.
After a 10 to 40 seconds period, all the Alarms in the system will
stop sounding except the source Alarm(s).
Silence the source Alarm(s)
If you are satisfied there is no fire but the Smoke/
Heat Alarm is still continuing to alarm you may now
silence the system. Wait until the SILENCE segment is
flashing red and then press the button. The SILENCE
segment will turn blue, after a delay the Alarm(s) will
stop sounding and all segments on the controller will
flash green momentarily to indicate that the Alarm
Controller is back in standby.
Temporary Alarm Activation:
Your alarm system could be activated by a false or
temporary alarm condition and then return to normal
Fire / CO Alarm Controller
Fire / CO Alarm Controller
Fire / CO Alarm Controller
Fire / CO Alarm ControllerFire / CO Alarm Controller
Fire / CO Alarm Controller
Fire / CO Alarm Controller
15
standby mode without being noticed. Should this happen the Ei450 will continue to flash either the Fire or CO
icon rapidly for a two minute period. If the system has been activated by a CO alarm the Ei450 will continue to
flash the CO Icon for a 24 hour period but at a lower rate of 1 flash every 60 seconds.
Should you observe this condition contact the appropriate authorities immediately.
5. Guarantee
Ei Electronics guarantees this Alarm Controller for 5 years from date of purchase against any defects that
are due to faulty materials or workmanship.
This guarantee only applies to normal conditions of use and service and does not include damage resulting
from accident, neglect, misuse, unauthorised dismantling, or contamination howsoever caused. This
guarantee excludes incidental and consequential damage.
This guarantee does not cover costs associated with the removal and/or installation of units.
If the product should become defective within the guarantee period, it may be returned with proof of
purchase, carefully packaged, and with the problem clearly stated to the place of purchase or phone one
of these numbers for advice.
UK: 0870 758 4001 ROI: +353 61 471277
We shall at our discretion repair or replace the faulty unit.
16
6. Troubleshooting the RadioLINK
If, when checking the RadioLINK interconnection, some of the Alarms do not respond to the Alarm
Controller remote control test, then:
(i) Ensure the Alarm Controller has been activated correctly. Check that the power on procedure operates
as described in the ‘Installation’ section.
(ii) Repeat House Code procedure (see ‘House Coding’ section).
(iii) Relocate the Alarm Controller and/or rotate/relocate the RadioLINK Alarms. There are a number of
reasons why the RadioLINK signals may not reach all the Alarms in your system. Try rotating the Alarms
or relocating the Alarms (e.g. move them away from metal surfaces or wiring) as this can significantly
improve signal reception.
Rotating and/or relocating the Alarms may move them out of the range of existing units even though
they may have already been House Coded correctly in the system. It is therefore important to check that
all Alarms are communicating in their final installed positions. If Alarms are rotated and/or relocated,
we recommend that all Alarms are returned to the factory settings (see the respective use and care
instructions). Then House Code all Alarms again in their final positions. The RadioLINK interconnection
should then be checked again.
17
7. Technical Specification
Supply Voltage Powered for life Lithium battery
Battery Capacity 1600 mAh
RF Frequency 868.499Mhz
Temperature Specification 0oC to 40oC (Cat 3)
Humidity 15% - 95% (Non Condensing)
Receiver Category Cat 2
RF Performance EN 300-220-2
EMC Performance EN 301 489-1, EN 301 489-3
Safety Testing EN 60065
RF Power +7dBm
Number of RF Alarms 12 per house code group
18
8. Getting the Alarm Controller serviced
If your Alarm Controller fails to work after you have carefully read all the instructions and checked that
the unit has been installed correctly contact Customer Assistance at the nearest address given at the end
of this booklet.
If it needs to be returned for repair or replacement, slide the switch to the
off position, place it in a padded box and send it to “Customer Assistance
and Information” at the nearest address given on the unit or in this booklet.
State the nature of the fault, where the Alarm Controller was purchased and
the date of purchase.
OFFON
POWERH.CODE
MODE
19
9. System Diagnostics
WARNING
WARNING
MODE
The system diagnostic mode does not work with all RadioLINK alarms and accessories. If the system
diagnostic features are required for your installation please contact technical support to verify that
all your RadioLINK components are compatible with these features.
The System Diagnostic features are intended to assist professional installation and maintenance
personal to install, commission and maintain the RadioLINK Fire and CO systems utilising the Alarm
Controller.
These features are not intended for the home owner / tenant and should only be used by personnel
described above.
System Diagnostic Mode
A special system diagnostic mode will facilitate the following special
tests.
1. Two minute “Long Test”. This is an alternative to the walk round test
described previously.
2. The check alarm memory test will identify an Alarm that had been
previously activated.
20
MODE
Fire / CO Alarm Controller
To enter the system diagnostic mode use a small screwdriver to press and release the MODE button on the back of
Fire / CO Alarm Controller
Fire / CO Alarm Controller
Fire / CO Alarm Controller
the unit. All segments will flash green almost immediately.
Quickly release the MODE button, the system diagnostic mode is now activated.
Two minute - Long test
On entering the system diagnostic mode the TEST segment will flash green
inviting you to press the button.
When you press the button the TEST segment will turn blue and all the
Alarms in the system will sound for 2 minutes.
This will allow you to walk around the house and verify that each individual
Alarm is sounding. During the test you may notice the TEST segment flash
blue periodically indicating that a refresh signal is being transmitted.
The test will automatically cease after 2 minutes or if the button is pressed
again. All the segments will flash green to indicate the test has been
completed. Wait 2 minutes before performing any additional tests.
21
Check Alarm memory
Fire / CO Alarm Controller
Fire / CO Alarm Controller
Fire / CO Alarm Controller
RadioLINK enabled Smoke and CO alarms have the ability to record if they have been
previously activated and store it in their memory. This can then be recalled via the
diagnostic mode.
On entering the system diagnostics mode, if an alarm memory has been set, the MEMORY
segment will flash green and the Fire or CO indicator will flash. Press the button until
the MEMORY segment turns blue. This will then locate the Alarm that was previously
activated and cause it to sound for a number of seconds (depending on the number of
RadioLINK Alarms and devices in the system).
Pressing the button again will cause it to sound again. This allows you to walk around
the house until you have found the activated Alarm.
The Alarm Controller will automatically exit the alarm identification test after 2 minutes
or if the MODE button is pressed again. All segments will turn green for a brief period as
the Alarm Controller exists the system diagnostic mode.
22
Erase Alarm memory
MODE
Fire / CO Alarm Controller
Block E1
0889
Press and hold the MODE button on the back of the unit. The green segments
will light up. When these segments start flashing, release the button. Press the
button on the alarm controller to test the system. The locate alarm memory
is now cleared.
Hereby, Ei Electronics declares that this Ei450 RadioLINK Alarm Controller is in compliance with
the essential requirements and other relevant provisions of Directive 1999/5/EC. The Declaration of
Conformity may be consulted at www.eielectronics.com/compliance
The crossed out wheelie bin symbol that is on your
product indicates that this product should not be disposed
of via the normal household waste stream. Proper
disposal will prevent possible harm to the environment or
to human health. When disposing of this product please
separate it from other waste streams to ensure that it can
be recycled in an environmentally sound manner. For
more details on collection and proper disposal, please
contact your local government office or the retailer where
you purchased this product.
23
10. Contact Us
As part of our continuous improvement policy, product performance and features are being frequently updated.
To facilitate this and keep you informed on the latest developments we have designed a product page on our
website that has all the current information on this product. This page is in addition to the information in this
manual and is not required for the successful installation and operation of your chosen product.
To access this website product page you may use your smart phone to activate the QR code or you
can go to this page on our website www.eielectronics.com/articles/ei450-memory-id-products.html