People with hearing difficulties require a different approach to fire protection, as a conventional alarm sounder will not be sufficient for their needs. Aico's range of alarms for the deaf and hearing impaired are the only units currently manufactured by an experienced European smoke alarm supplier.They are also available with RadioLINK wire free radio signal technology, for ease of installation.
System Features & Benefits
Control panel with rechargeable battery back-up,
mains power supply lead and 13 amp Plug
High intensity integral strobe light
Auxiliary socket for connection of additional
optional strobe lights
Vibrating pad for placing under a pillow or mattress
Capability for interconnection of up to 12 smoke
alarms
Test button on control panel for testing the system
Connections are monitored to check integrity of
system
Alarm clock input facility
Remote trigger option
Pager output facility
Four Levels of Protection & Security
Specifier’s First Choice
Ei169/160 - Hard wired interconnect to 10 Year, Mains Rechargeable Smoke Alarm System
Ei169RF - Wire free Radio Signal Technology to Smoke Alarm System
Owner Occupier Options
Ei176 - Smoke Alarm powered from Control Panel
Ei176RF - Wire free Radio Signal Interconnect to PP3 Battery Powered Smoke Alarm
Specification for Smoke & Heat Alarms
for the Deaf & Hearing Impaired
System
Model No.
Control
Panel With
Integral
Strobe
Vibrating
Pad
Installation
Smoke Alarm Options
Ionisation Optical
Ei169/160
Hardwired
Ei161 (not supplied) Ei166 (not supplied)
Ei169RF
Mains option only
Ei161 (not supplied)
use with
Ei168 RadioLINK Base (not supplied)
Mains option
Ei166 (not supplied)
use with
Ei168 RadioLINK base (not supplied)
Battery operated options
Ei405TY RadioLINK alarm with
10 Year Lithium cells
Ei405 RadioLINK alarm with
Alkaline Battery
Ei176
Hardwired
Not available
Supplied with smoke alarm
powered from the
control panel
Ei176RF
Not available
Supplied with RadioLINK smoke alarm
powered by an integral PP3 battery
Power supply:
220/240 VAC, 50/60 Hz
Electrical Safety:
Complies with BS415: 1990.
Ambient temperature:
4° to 40°C Humidity 0% to 90% RH
Strobe:
Intense built-in Xenon tube flashes every second.
Battery:
Long-life sealed lead-acid rechargeable battery: Standby capacity 7 days (followed by 4 minutes alarm) - 5 year lifespan in normal use.
Indicator Lights:
Green - mains supply; Red flashing - battery supply
only. With mains off, red light goes off as battery becomes depleted.
Mounting:
Designed for wall mounting with fixing screws provided
Power Switch:
Slide switch disconnects mains and battery power
from panel. Extinguishes both LEDs.
Test Button:
Checks strobe, vibration pad and panel (also smoke
alarms on Ei169RF & Ei176RF models)
Mains Transformer:
Mounted in a separate box, hard-wired to control panel with 4m of low voltage cable. Supplied with 2m of mains cable and 13 amp plug.
Vibrating pad:
Supplied with all models. Suitable for mattresses or pillows. Produces strong pulsed vibrations suitable for waking sleepers. Supplied with locking plug and 2m of cable.
Vibration Pad Socket:
Locking socket (JST type VHR-2N) provided for vibration pad. Output 12V/200mA is pulsed in alarm for greater effect.Wiring is monitored - if vibration pad is not connected or if it is open circuit the strobe will flash.
Aux Socket:
Locking socket for extra strobe (Ei178) or vibration pad
etc. provides 12V/200mA in alarm.
Smoke Alarm Wiring (Not Ei176RF & Ei169RF):
Low voltage cable (10m) is supplied hard-wired to the panel for connection to the smoke alarm. Wiring is monitored - if it is not connected or if it is open/short circuited the strobe will flash and vibration pad will turn on.
Clock Input:
Used with alarm clocks, so only one vibration pad is needed under mattress/pillow. 5 to 24 volts (AC or DC mains isolated) will turn on vibrator pad only i.e. no strobe. Socket takes 3.5mm mono jack plug.
Interconnection:
Up to 12 smoke alarms can be interconnected.
Control Devices:
RadioLINK models Ei169RF and Ei176RF can be connected to RadioLINK Test & Hush Switch Ei411 and Remote Relay Module Ei428 for signalling to a Warden Call System.
Green mains indicator illuminates to show mains power is
present
Red battery indicator flashes when mains power is off to show
that the unit is running on battery only power. The red indicator goes off when the battery is fully depleted
The slide switch on the control panel disconnects the mains
and battery power from the control panel and extinguishes both the red and green indicators
The Test button on the side of the control panel checks the
operation of the strobe light and vibrating pad on all models. In addition, it activates the smoke alarm and any other RadioLINK control devices on Ei169RF and Ei176RF models
When any of the smoke alarms are activated the control
panel will flash the strobe light once per second and also activate the vibrating pad
The Auxiliary socket allows the connection of an additional
strobe, vibrating pad or to trigger a radio frequency pager
Extra Features
Ei411 - Test & Locate Switch
A completely wire-free, wall mounted switch designed for use with the Ei169RF and Ei176RF models. Allows easy control of false alarms without having to reach up to the smoke alarm.
Ei428 - Remote Relay Module
Ideal for use with the Ei169RF and Ei176RF models to signal an alarm to a Warden Call System.The module is wire-free except for a connection to the mains supply.
Aico Ltd, Mile End Business Park, Maesbury Road, Oswestry, Shropshire SY10 8NN Tel: 0870 758 4000 • Fax: 0870 758 4010 • e-mail: enquiries@aico.co.uk • www.aico.co.uk
Customer Service Helpline: 0870 758 4000
E & OE As our policy is one of continuous development, we reserve the right to amend designs and specifications without prior notice. Every care has been taken to ensure that the contents of this document are correct at the time of publication and we shall be under no liability whatsoever in respect of such contents.
Aico Ltd is a wholly owned
subsidiary of Ei Electronics
SASD 0306 Issue 1
Specification
Operation
Loading...