HB 100 MICROWAVE SENSOR MODULE
10.525GHz Microwave Motion Sensor Modul
Block diagram and connection
Description
HB100 Miniature Microwave Motion Sensor is a X-Band Bi-Static
Doppler transceiver module. Its built-in Dielectric Resonato
Oscillator (DRO) and a pair of Microstrip patch antenna array,
make it ideal for OEM usage in motion detection equipment.
This module is ideally suitable for false alarms reduction in intrude
detectors when work together with Passive Infrared (PIR) sensor. It
can also be used for auto-door opening and vehicle speed
measurement.
• Low current consumption
• CW or Pulse operation
•
Flat profile
Long detection range
•
Antenna Beam Pattern
180
0
-6
-12
-18
-24
-30
30
60
-6
-12
-18
-24
150
90
120
330
300
270
240
210
Applications Features
• Microwave-PIR motion detecto
• Speed measurement
• Lighting control
180
0
-6
-12
-18
-24
-30
-36
30
-18
-24
-30
150
330
300
270
240
210
60
-6
-12
90
120
Azimuth
Elevation
HB 100 Microwave Sensor Module
SS ISO 9001 : 2000
CERT. NO. : 94-1-0033
HB 100 MICROWAVE SENSOR MODULE
Technical Specifications
Outline diagram (All dimensions in mm)
Elevation
Azimuth
Unless noted otherwise, the specifications are measured with +5VDC, CW operation, 12 kΩ load at ambient
temperature of +25°C.
Parameter Notes Min Typ. Max Units
Frequency Setting 1 10.520 10.525 10.530 GHz
Radiated Power (EIRP) 1 12 15 20 dBm
Spurious Emission 1 -7.3 dBm
Settling Time 3 6 µSec
Received Signal Strength 2 200 µVp-p
Noise 3 5 µVrms
Antenna Beam-width (3 dB) - Azimuth 80 °
Antenna Beam-width (3 dB) - Elevation 40 °
Supply Voltage 4.75 5.00 5.25 VDC
Current Consumption 30 40 mA
Pulse Repetition Frequency 4 2 KHz
Pulse Width 4 10 µSec
Operating Temperature -15 55 °C
Weight 8 gm
Note 1: The radiated emissions of HB100 is designed to meet the requirements of Federal Communications
Commission (FCC) rules, Part 15, Section 15.245 (use within a building or to open building door)
Note 2: The Received Signal Strength (RSS) is measured at the total 2 ways path loss of 93dB.
Note 3: The noise voltages are measured from 10 Hz to 100 Hz at the output port, inside an Anechoic
chamber.
Note 4: Pulse operation.
Note 5: The design, manufacturing process and specifications of this device are subjected to change
without prior notice.
Note 6: CAUTION
: ELECTROSTATIC SENSITIVE DEVICE. Observe precautions for handling and storage.
VER 1.02