Agilent MSOX3054A Data Sheet

Infi niiVision 3000 X-Series Oscilloscopes
Data Sheet
Oscilloscopes redefined:
Breakthrough technology delivers
more scope for the same budget
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Breakthrough technology for budget conscious customers
your existing budgets. Whether you are looking for a basic entry-level oscilloscope or a more sophisticated model to get your job done, you want the most you can get for your money. The full line of InfiniiVision X-Series oscilloscopes – 30 models – ensure that you get exactly what you need today with room to grow in the future.
Overview of the Agilent InfiniiVision X-Series oscilloscopes
InfiniiVision 2000 X-Series InfiniiVision 3000 X-Series
Analog channels 2 and 4 analog channels Bandwidth (upgradable) 70, 100, 200 MHz 100, 200, 350, 500 MHz, 1 GHz Maximum sample rate 1 GSa/s per channel
2 GSa/s half-channel interleaved mode
Maximum memory depth 100 kpts (standard) 2 Mpts standard, 4 Mpts optional
Waveform update rate 50,000 waveforms per second 1,000,000 waveforms per second Digital timing channels 8 on MSO models or with
DSOX2MSO upgrade
WaveGen built-in 20 MHz function/arbitrary waveform generator
Integrated Digital Voltmeter Yes (option DSOXDVM) Yes (option DSOXDVM) Search and navigate No Yes Serial protocol analysis No Yes (multiple options), see page 18 Segmented memory Yes (Option DSOX2SGM) Yes (Option DSOX3SGM) Mask limit testing Yes (Option DSOX2MASK) Yes (Option DSOX3MASK) AutoProbe interface No Yes Power Analysis No Yes (Option DSOX3PWR) Advanced Waveform Math No Yes (Option DSOX3ADVMATH)
Yes (Option DSOX2WAVEGEN) No AWG capability
2 GSa/s per channel (2.5 GSa/s on 1 GHz models) 4 GSa/s half-channel interleaved mode (5 GSa/s on 1 GHz models)
(Option DSOX3MemUp)
16 on MSO models or with DSOX3MSO (for 500 MHz models and below) and DSOXPERFMSO for 1 GHz models upgrade
Yes (Option DSOX3WAVEGEN) With AWG capability
Need more memory or a bigger screen?
See the InfiniiVision 7000B Series oscilloscopes
• 12” display - nearly 40% larger than the nearest competitor.
• 100 MHz to 1 GHz DSO and MSO models
• 8 Mpts memory standard.
• Upgradability for MSO channels and measurement applications
• Hardware-based measurement applications including serial decode
• Xilinx FPGA dynamic probe support
• Altera FPGA dynamic probe support
• Standard LAN, USB, and XGA video out connectivity
See www.agilent.com/find/7000 for more details
2
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
More scope
The InfiniiVision 3000 X-Series offers entry-level price points to fit your budget with superior performance and optional capabilities that are not available in any other oscilloscope in its class. Our breakthrough technology delivers more scope for the same budget.
With more scope, you can:
• See more of your signal more of the time with the largest screen in its class, the deepest memory and the fastest waveform update rates
• Do more with the power of 5 instruments in 1: oscilloscope, logic timing analyzer, WaveGen built-in 20 MHz function/arbitrary waveform generator (optional), integrated digital voltmeter and protocol analyzer (optional)
• Get more investment protection with the industry’s only fully upgradable scope, including bandwidth and the most measurement applications available
3
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
See more of your signal, more of the time
Largest display
Engineering for the best signal visibility starts with the largest display. Our 8.5-inch WVGA display offers 50% more viewing area with 4 times the resolution (WVGA 800x480 versus WQVGA 400x240) so you can view analog, digital and serial signals easily on screen.
Fastest update rate
With Agilent-designed MegaZoom IV custom ASIC technology, the 3000 X-Series updates waveforms up to 1 million times per second. If an oscilloscope updates waveforms slowly, it can make using the oscilloscope very frustrating. Fast waveform update rates can improve oscilloscope display quality to show subtle waveform details such as noise and jitter with display intensity modulation. Most importantly, fast waveform update rates improve the probability of capturing random and infrequent events that would not be captured using an oscilloscope with a lower waveform update rate.
Notice that the Agilent 3000 X-Series allows you to see more of your signals, and captures the infrequent glitch and jitter that you are unable to see on other oscilloscopes in this class.
4
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
See more of your signal, more of the time
Deeper memory for longer time capture
With up to 4 Mpts of MegaZoom IV deep memory, you can capture long, non-repeating signals while maintaining a high sample rate, then quickly zoom in on areas of interest.
The InfiniiVision X-Series optimizes your deep memory oscilloscope measurements by using MegaZoom IV technology to make the most effective trade-offs in sample rate, memory depth and waveform update rate. Although you may think deeper memory is always better, using deep memory means making tradeoffs for many other scopes on the market today.
Scopes with deep memory are typically priced higher, and require additional waveform processing time to acquire deep memory waveforms. This typically means waveform update rates will be reduced, sometimes significantly. For this reason, most other scopes have manual memory-depth selections, and the typical default memory depth setting is usually relatively shallow (10 to 100 kpts). If you want to use deep memory in these other scopes, you must manually turn it on and deal with the update rate tradeoff. So you have to know when it is important to use deep memory and when it is not.
Agilent’s exclusive MegaZoom IV technology automatically selects deeper memory when needed in order to maintain fast sample rates while also updating quickly.
How does Agilent do that?
Agilent-designed MegaZoom IV custom ASIC technology combines the capabilities of an oscilloscope, logic analyzer, protocol analyzer, and WaveGen built-in function generator in a compact form factor at an affordable price. 4th genera­tion MegaZoom technology enables the industry’s fastest waveform update rate with responsive deep memory acquisitions.
5
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Do more with the power of 5 instruments in 1
Best-in-class oscilloscope
The InfiniiVision 3000 X-Series features the deepest memory in its class with up to 4 Mpts of Agilent’s patented MegaZoom IV technology that is always enabled and always responsive providing the industry’s fastest update rate at up to 1 million waveforms per second, with no compromise if you turn on measurements or add digital channels.
In addition, the 3000 X-Series offers 33 automated measurements, nine parametric triggers, serial protocol triggers, as well as waveform math functions including FFT. All of this at a comparable price to the Tektronix DPO2000 oscilloscope.
Industry’s only upgradable, integrated mixed signal oscilloscope (MSO)
The 3000 X-Series is the first instrument in its class to offer an integrated and upgradable logic timing analyzer. Digital content is everywhere in today’s designs and tradi­tional 2 and 4 channel oscilloscopes do not always provide enough channels for the job at hand.
With an additional 16 integrated digital timing channels, you now have up to 20 channels of time-correlated trigger­ing, acquisition and viewing on the same instrument. Buy a 2 or 4 channel DSO and at anytime, upgrade it yourself to an MSO with a license to turn on those integrated 16 digital timing channels.
Industry-exclusive WaveGen built-in 20 MHz function/arbitrary waveform generator
An industry first, the 3000 X-Series offers an integrated built-in 20 MHz function/arbitrary waveform generator. The integrated function generator provides stimulus output of sine, square, ramp, pulse, DC, Sinc (x) exponential rise/fall, cardiac, Gaussian Pulse and noise waveforms to your device under test.
With AWG functionality, you can store the waveforms from analog channels or reference memory to the arbitrary memory and output from WaveGen. Easily create/edit the waveform using built-in editor or by using Agilent’s free Benchlink Waveform Builder Basic:
www.agilent.com/find/33503.
Turn on WaveGen at any time by ordering the DSOX3WaveGen option and install the license yourself.
6
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Do more with the power of 5 instruments in 1
Integrated digital voltmeter
An industry first, the 3000 X-Series offers an integrated 3-digit voltmeter (DVM) and 5-digit frequency counter inside the oscilloscopes. The voltmeter operates through the same probes as the oscilloscope channels, however, the measurements are de-coupled from the oscilloscope triggering system so that both the DVM and triggered oscilloscope measurements can be made with the same connection. The voltmeter results are always displayed, keeping these quick characterization measurements at your fingertips. Turn on DVM at any time by ordering the
DSOXDVM option.
Hardware-based serial protocol decode and triggering
• Embedded serial triggering and analysis (I2C, SPI)
• Computer serial triggering and analysis (RS232/422/485/UART)
• Automotive and industrial serial triggering and analysis (CAN,LIN)
• FlexRay automotive triggering and analysis
• Audio serial triggering and analysis (I2S)
• Aerospace and Defense serial triggering and analysis (MIL-STD 1553 and ARNC 429)
Agilent’s InfiniiVision Series oscilloscopes are the industry’s only scopes to use hardware-based serial protocol decoding. Other vendors scopes use software post-processing techniques to decode serial packets⁄ frames. With these software techniques, waveform and decode-update rates tend to be slow (sometimes seconds per update). That’s especially true when using deep memory, which is often required to capture multiple packetized serial bus signals. Faster decoding with hardware-based technology enhances scope usability, and more importantly, the probability of capturing infrequent serial communication errors.
After capturing a long record of serial bus communication using the InfiniiVision scope’s MegaZoom IV deep memory, you can easily perform a search operation based on specific criteria, and then quickly navigate to bytes/frames of serial data that satisfy that search criteria. Sometimes it may be necessary to correlate data from one serial bus to another. Agilent’s InfiniiVision 3000 X-Series oscilloscope can decode and list two serial buses simultaneously using hardware-based decoding. as well as display the captured data in a time interleaved “Lister” display.
7
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Get more investment protection with the industry’s only fully upgradable oscilloscope
Upgradability:
Project needs change, but traditional oscilloscopes are fixed – you get what you pay for at the time of purchase. With the 3000 X-Series, your investment is protected. If you need more bandwidth (up to 1 GHz), digital channels, WaveGen, DVM or measurement applications in the future, you can easily add them all after the fact.
See pages 32 and 33 for more detailed information on available upgrades.
Mask testing
Add at the time of your purchase or upgrade later:
• Bandwidth
• Digital channels (MSO)
• WaveGen built-in 20 MHz function/arbitrary waveform generator
• Integrated digital voltmeter
• Measurement applications
◦ Serial protocol analysis ◦ Power measurement analysis ◦ HDTV video triggering and analysis ◦ Advanced math analysis ◦ Mask testing ◦ Segmented memory ◦ Educators’ lab kit
Whether performing pass/fail tests to specified standards in manufacturing or testing for infrequent signal anomalies in R&D debug, the mask test option can be a valuable productivity tool. The 3000 X-Series features the industry’s only hardware-based mask testing and can perform up to 200,000 tests per second.
Multiple test criteria can be selected including the ability to run tests for a specific number of acquisitions, time, or until detection of a failure. Pass/fail masks can be auto­matically created based on an input reference waveform along with user-specified tolerance bands, or can be cre­ated on a PC and then imported via a USB memory stick.
8
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Get more investment protection with the industry’s only fully upgradable oscilloscope
Segmented memory
When capturing low-duty cycle pulses or data bursts, you can use segmented memory acquisition to optimize acquisition memory. Segmented memory acquisition lets you selectively capture and store important segments of signals without capturing unimportant signal idle/dead­time. Segmented memory acquisition is ideal for applica­tions including packetized serial buses, pulsed laser, radar bursts and high-energy physics experiments. Up to 1000 segments can be captured on the 3000 X-Series models with a minimum re-arm time under 1 µs.
Power Measurement and Analysis
When working with switching power supplies and power devices, the DSOX3PWR power measurements application provides a full suite of power measurements and analysis that runs in the oscilloscope. Measurements include:
• Current harmonics
• Efficiency
• Inrush current
• Modulation
• Power quality
• Switching response
• Transient response
• Turn on/turn off
• Output ripple
• Power Supply Rejection Ratio (PSRR)
• Slew rate Also included at no additional charge is a license for
the U1881A PC-based power analysis software package which provides additional offline measurements and report generation.
9
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Get more investment protection with the industry’s only fully upgradable oscilloscope
HDTV video triggering and measurement analysis.
Whether debugging consumer electronics with HDTV or characterizing a design, the DSOX3VID measurement appli­cation provides support for a variety of HDTV standards including:
• 480p/60
• 567p/50
• 720p/50
• 720p/60
• 1080i/50
• 1080i/60
• 1080p/24
• 1080p/25
• 1080p/30
1080p/50
• 1080p/60
• Generic (custom bi-level and tri-level sync video standards)
Advanced math analysis
In addition to the standard waveform math functions (add, subtract, multiply, integrate, differentiate, square root, FFT), the optional DSO3ADVMATH application provides additional advanced waveform transforms, filters, and visualization tools including:
Transforms
• Ax + B
• Square (x2)
• Absolute value (|x|)
• Common logarithm (log)
• Natural logarithm (ln)
• Exponential (eX)
• Base 10 exponential (10X)
Filters
• Low pass filter (4th order Bessel-Thompson filter with selectable -3dB frequency)
• High pass filter (single-pole high pass filter with selectable -3dB frequency)
Visualizations Tools
• Magnify
• Measurement trend
• Chart logic bus timing
• Chart logic bus state
10
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Get more investment protection with the industry’s only fully upgradable oscilloscope
InfiniiView Oscilloscope Analysis Software (N8900A)
Agilent’s InfiniiView PC-based analysis oscilloscope soft­ware allows you to do additional signal viewing, analysis and documentation tasks away from your scope. Capture waveforms on your scope, save to a file, and recall the waveforms into InfiniiView. The application supports a variety of popular waveform formats from multiple oscilloscope vendors and includes the following features:
Navigate
• Pan and zoom to anywhere in the data record. Navigate in time, or between bookmarks.
View
• Up to 8 waveforms simultaneously, 1, 2, or 4 grids (stacked, side by side, custom layout, zoom)
Measurements
• Over 50 automated measurements
• View up to 20 simultaneously
• User-customizable result window (size, position, information)
• X & Y markers with dynamic delta values
View and analyze away from your scope and target system
Analyze
• 20 math operators including FFT and filters
• Up to four independent/cascaded math functions
• Measurement histogram
View Windows
• Analog, math, spectral, measurement results (simultaneous, tabbed, or undocked)
Documentation
• Right-click to copy
• Up to 100 bookmarks
• Annotated axis values
• Markers with dynamic delta value updates when moved
• One step save/load setup and all waveforms
Analysis Upgrades (Optional)
• Protocol decode for I2C/SPI, RS232/UART, CAN/ LIN/FlexRay, SATA, 8B/10B, digRF v4, JTAG , MIPI D-Phy, SVID, Ehernet 10G KR, PCIe 1, 2, 3, USB 2, 3, HSIC
• Jitter analysis
• Serial data analysis
Use familiar scope controls to quickly navigate and zoom in to any event of interest.
Add bookmarks and call outs to produce friendly and useful documentation.
11
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Other productivity tools
Agilent Spectrum Visualizer (ASV) Software
This PC-based software package connects to the scope via USB or ethernet connection and uses the Agilent I/O libraries to communicate. It provides advanced FFT frequency domain analysis at a cost-effective price as well as spectrum and spectrogram analysis with an intuitive user interface that RF engineers are familiar with. Tools include:
Spectrum Measurements
• Power (dBm) vs. frequency
• Horizontal (x-axis): Specify center frequency and frequency span, or start and stop frequencies
• Vertical (y-axis): Specify reference level (dBm) and scale (dB/div)
• Settable resolution bandwidth
• Flat top, Guassian, or Hanning windows applied to the time domain data for the FFT analysis
• Marker to peak amplitude, and marker to center frequency.
• Marker peak search can be enabled for time-varying signals
• Multiple marker, with delta X and delta Y readouts
Waterfall View for ASV Spectrogram Measurement
Acquisition and Display Modes
• Free Run (continuous ), Triggered, Stop, Single, Preset
• Triggered mode: specify trigger power level (dBm), single or continous sweep
• Enable/disable y-axis label
• Enable/disable main trace display
• Max hold display mode
• Gated Measurements
• Multiple viewing options
- Spectrogram
- waterfall
- 3D
• Changeable scaling settings on main window
• Local language support
• Multiple oscilloscopes can be configured to allow user to rapidly switch between multiple instruments
Arbitrary Waveform Generator Source Control
• 20 MHz sine wave
• 10 MHz square wave
• Pulsed waveform
• WaveGen source settings can be altered while ASV is running for interactive signal source and analysis capability
Close-Up Detail on Frequency Shift Keying (FSK) Characteris­tics with the ASV Spectrogram Measurement
12
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Other productivity tools
Reference waveforms
Store up to two waveforms in the scope’s non-volatile reference waveform memory locations. Compare these reference waveforms with live waveforms, and perform post analysis and measurements on stored data. You can also store waveforms on a removable USB memory device in *.h5 format and recall them back into scope’s reference waveform memory later. Save and/or transfer waveforms to a PC as XY data pairs in a comma-separated values format (*.csv) or store bitmap images and transfer them to a PC for documentation purposes in a variety of image formats including: 8-bit bitmaps (*.bmp), 24-bit bitmaps (*.bmp), and PNG 24-bit images (*.png).
Localized GUI and help
Operate the scope in the language most familiar to you. The graphical user interface, built-in help system, front panel overlays, and user’s manual are available in 11 languages. Choose from: English, Japanese, simplified Chinese, traditional Chinese, Korean, German, French, Spanish, Russian, Portuguese and Italian. During operation, access the built-in help system just by pressing and hold­ing any button.
Probe solutions and compatibility
Get the most out of your 3000 X-Series scope, by using the right probes and accessories for your application. Agilent offers a complete family of innovative probes and accessories for the InfiniiVision 3000 X-Series scopes. For the most up-to-date and complete information about Agilent’s probes and accessories, visit our Web site at
www.agilent.com/find/scope_probes.
Also available is the N2744A T2A (Tektronix TekProbe® interface to Agilent AutoProbe) probe interface adapter. This adapter allows users of Tektronix TekProbe active probes to connect directly to the InfiniiVision 3000 X-Series AutoProbe interface BNC input. Protect your previ­ous probe investment while taking advantage to the
InfiniiVision 3000 X-Series’ unique capabilities and value.
Autoscale
Quickly display any active signals and automatically set the vertical, horizontal and trigger controls for optimal viewing with the press of the autoscale button. (This feature can be disabled or enabled for the education environment).
13
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Other productivity tools
Connectivity and LXI compatibility
Built-in USB host (one front, one back) and USB device ports make PC connectivity easy. Operate the scope from your PC and save/recall stored waveforms as well as set-up files via LAN. The optional LAN/VGA module gives you network connectivity and complete LXI class C support as well as the ability to connect to an external monitor. An optional GPIB module is also available. Only one module may be used at a time.
Intuilink toolbars and Data Capture gives you a quick way to move screen shots and data into Microsoft Word and Excel. These toolbars can be installed from
www.agilent.com/find/intuilink
Virtual front panel
Use the VNC viewer via your internet browser to remotely control your oscilloscope from your computers web browser. The virtual front panel looks and acts as the real front panel on the oscilloscope with the same associated keys and knobs. Use this capability in cases where remote training and learning of the oscilloscope are required. This instrument is fully LXI complaint with the LAN/VGA connection module.
Warranty and calibration
Through improved quality processes and rigorous testing, the Agilent InfiniiVision X-Series Oscilloscopes are now able to perform at specification for two years without yearly calibration thereby reducing cost of ownership to you.
Secure Environment Mode (SEC)
The secure environment mode comes standard with all models and provides the highest level of security by ensur­ing that internal non-volatile memory is clear of all setup and trace settings. This option stores setups and traces to internal volatile memory only, and volatile memory is cleared during the power off cycle of the instrument. This procedure ensures that all setup and trace settings are removed from memory.
14
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Designed with research and development in mind
Find more glitches and infrequent events quickly
Debugging and fixing designs is one of the most important tasks of R&D engineers so that they can ship reliable prod­ucts to their customers. Finding the infrequent and random circuit problem is often like looking for a needle in a hay­stack. In addition to fast waveform updates, which improve a scope’s probability of capturing infrequent anomalies, it is often necessary to search waveform records and/or trigger on specific pulse parametric violation conditions. Agilent’s InfiniiVision 3000 X-Series oscilloscope provide the most comprehensive set of search & navigation capabilities, as well as the most advanced set of pulse parameter triggering selections of any oscilloscope in its class. Get a long scope life and keep repair costs to a minimum with a standard 3-year warranty and an instrument reliability you’ve come to expect from the leader in test and measurement equipment.
Search and navigation
When capturing long complex waveforms using the scope’s deep acquisition memory, manually scrolling through stored waveform data to find specific events of interest can be slow and cumbersome. But with the InfiniiVision 3000 X-Series scope’s automatic search & navigation capability, you can easily set up specific search criteria and then quickly navigate to “found and marked” events using the scope’s front panel forward and back navigation keys. Available search criteria include: edges, pulse width (time-qualified), rise/fall times (time-qualified), runt pulses (time- and level-qualified), and serial.
In the example shown in the screen image on the right, the scope was set up to capture a 1 millisecond time-span of a complex digital data stream. Using the scope’s search & navigation capability, the scope was able to find, mark (white triangles shows location of each runt), and then quickly navigate to 20 occurrences of “runt” pulses.
Advanced parametric and serial bus triggering
With today’s more complex signals, it is also often neces­sary to trigger on complex signal conditions in order to synchronize the scope’s acquisition on specific events of interest. Agilent’s InfiniiVision 3000 X-Series scopes can trigger on the following conditions: edge, pulse width (time-qualified), pattern, rise/rall time, Nth edge burst, runt, setup & hold, video, USB, Serial1, and Serial2.
15
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Designed with education in mind
Quickly and easily set up or upgrade a teaching lab
Teach your students what an oscilloscope is and how to perform basic measurements with the Educator’s Oscilloscope Training Kit (DSOXEDK). It includes training tools created specifically for electrical engineering and physics undergraduate students and professors. It contains an array of built-in training signals, a comprehensive oscilloscope lab guide and tutorial written specifically for the undergraduate student and an oscilloscope fundamentals PowerPoint slide set for professors and lab assistants. For more information, refer to:
www.agilent.com/find/EDK. With features such as the
ability to disable autoscale and the 50 Ohm input path, the InfiniiVision X-Series is a perfect choice for education
Get your students to quickly put the scope to work
Intuitive localized front panel design with pushable knobs for quick access to commonly used oscilloscope functions, help students spend more time learning the concepts and less time learning how to use the oscilloscope. Enable your students to answer their own questions with the localized built-in help system that provides quick access by simply
pressing and holding any button.
Stretch your budget over the long term
Save money with an industry-exclusive built-in WaveGen function/arbitrary waveform generator instead of buying a separate function generator. Buy what you need today and protect your investment in the future with the only oscilloscopes in this class with upgradable bandwidth, 16 digital channels (MSO), upgradable WaveGen, integrated digital voltmeter and measurement applications. Get a long scope life and keep repair costs to a minimum with a standard 3-year warranty and an instrument reliability you’ve come to expect from the leader in test and
measurement equipment.
Optimize lab bench space
With 5 instruments in 1, you will save on precious lab bench space by getting an oscilloscope, logic timing analyzer, protocol analyzer, WaveGen built-in 20 MHz function/arbitrary waveform generator and integrated digital voltmeter all in one innovative instrument with a footprint that is only 5.57inches deep. With the large
8.5-inch WVGA display, you can easily view all signals on one screen with enough viewing area for more than one
student to view.
16
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Designed with manufacturing in mind
Stretch a limited budget
Production needs change, but traditional oscilloscopes are fixed – you get what you pay for at time of purchase. With the 3000 X-Series, your investment is protected. If you need more bandwidth (up to 1 GHz) or measurement applications like mask testing in the future, you can easily add them all when you need it.
Get your technicians to quickly put the scope to work
Intuitive localized front panel design and pushable knobs for quick access to commonly used oscilloscope functions, allow technicians to spend more time testing and less time learning where the menus are on the oscilloscope. Enable your technicians to answer their own questions with the localized built-in help system that provides quick access by simply pressing and holding any button.
Get a long scope life and keep repair costs to a minimum with a standard 3-year warranty and a 2-year calibration interval, you get the instrument reliability you’ve come to expect from the leader in test and mea­surement equipment.
Faster, low failed device escape test throughput
With the fastest architecture in its class, featuring up to 1,000,000 waveforms/sec, you will capture more of those elusive problems you worry about and ensure they don’t ship to customers. With the mask limit testing measure­ment application, you can quickly test up to 200,000 waveforms per second to a known good waveform with a quick go/no-go test results, saving you valuable test time while having more certainty.
Optimize test bench space
With 5 instruments in 1, you will save on precious line bench space by getting an oscilloscope, logic timing analyzer, protocol analyzer, WaveGen built-in 20 MHz function/arbitrary waveform generator, and integrated digital voltmeter all in one innovative instrument with a footprint that is only 5.57inches deep. With the large
8.5-inch WVGA display, you can easily view all signals on one screen even when the scope is sitting far away from the operator.
17
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Oscilloscope shown actual size
8.5-inch high resolution wide screen display reveals subtle details that most scopes don’t show you
WaveGen – Industry first built-in function generator/AWG
Get up to sixteen integrated digital channels
18
Built-in USB port makes it easy to save your work and update your system software quickly
Quick summary display of sample rate, channel settings and measurements
Search and navigate front panel controls make it easy to find and view specific signal activity quickly play, stop, rewind and fast forward through waveforms
Quickly pan and zoom for analysis with MegaZoom IV’s instant response and optimum resolution
Autoscale lets you quickly display any analog or digital active signals, automatically setting the vertical, horizontal and trigger controls for the best display, while optimizing memory
Dedicated keys for quick access to serial, digital channels, math functions and reference waveforms
Demo and training signals
All front panel knobs are pushable
Integrated digital voltmeter
AutoProbe interface automatically configures the attenuation ratio of the probe and provides the probe power for Agilent’s active probes
19
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Configuring your InfiniiVision X-Series oscilloscope
Step 1. Choose your bandwidth, number of channels and memory depth.
InfiniiVision 3000 X-Series scopes
DSOX3012A MSOX3012A
Bandwidth
100 MHz 100 MHz 200 MHz 350 MHz 350 MHz 500 MHz 500 MHz 1 GHz 1 GHz
(upgradable)* Analog
channels Digital channels
(MSO) Memory 2 Mpts half-channel standard, or 4 Mpts half-channel (DSOX3MEMUP)*
* See pages 26 and 27 for more detailed upgradability information.
Step 2. Tailor your scope with measurement applications to save time and money.
Application 3000 X-Series
WaveGen (built-in function/arbitrary waveform generator) DSOX3WAVEGEN Integrated digital voltmeter DSOXDVM Benchlink Waveform Builder Pro and Basic 33503A Educator’s kit DSOXEDK Mask testing DSOX3MASK Segmented memory DSOX3SGM Embedded serial triggering and analysis (I Computer serial triggering and analysis (RS232/422/485/UART) DSOX3COMP Automotive serial triggering and analysis (CAN, LIN) DSOX3AUTO Automotive triggering and analysis (FlexRay) DSOX3FLEX Audio serial triggering and analysis (I Aerospace and defense serial triggering and analysis
(MIL-STD 1553 and ARNIC429) Power measurement and analysis DSOX3PWR HDTV Video triggering and analysis DSOX3VID Advanced math analysis DSOX3ADVMATH InfiniiView oscilloscope analysis software N8900A Agilent spectrum visualizer (ASV) 64997A Vector signal analyzer software 89601B (Version 15 and higher only)
* See pages 27 and 28 for more detailed upgradability information, and installation process.
DSOX3014A MSOX3014A
DSOX3024A MSOX3024A
DSOX3032A MSOX3032A
DSOX3034A MSOX3034A
DSOX3052A MSOX3052A
DSOX3054A MSOX3054A
DSOX3102A MSOX3102A
DSOX3104A MSOX3104A
24424 2 42 4
16 integrated digital channels (optional)*
2
C, SPI) DSOX3EMBD
2
S) DSOX3AUDIO
DSOX3AERO
20
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Configuring your InfiniiVision X-Series oscilloscope
Step 3. Choose your probes - For complete list of compatible probes, see Agilent document 5968-8153EN.
Probes 3000 X-Series
N2862B Passive probe 150 MHz 10:1 attenuation 1 per channel included 100 MHz models N2863B Passive probe 300 MHz, 10:1 attenuation 1 per channel included 200 MHz models N2890A Passive probe 500 MHz, 10:1 attenuation 1 per channel included 350/500 MHz/1 GHz models N6450-60002 16 digital channel MSO cable 1 per scope included on all MSO models and
DSOX3MSO (500MHz models and below)
DSOXPERFMSO (1 GHz model) upgrades N2889A Passive probe 350 MHz 10:1/1:1 switchable attenuation Optional 10076B Passive probe 250 MHz 100:1 attenuation Optional N2771B Passive probe 50 MHz 1000:1 attenuation Optional N2795A Single-ended active probe 1 GHz ±8 V with AutoProbe interface Optional N2790A Differential active probe 100 MHz ±1.4 kV with AutoProbe interface Optional N2791A Differential active probe 25 MHz ±700 V Optional N2792A Differential active probe 200 MHz ±20 V Optional N2793A Differential active probe 800 MHz ±15 V Optional 1146A AC/DC Current probe 100 kHz 100 A Optional 1147A AC/DC Current probe 50 MHz 15 A with AutoProbe interface Optional N2893A AC/DC Current probe 100 MHz 15 A with AutoProbe interface Optional
* See page 27 for probe compatability table
Step 4. Add the final touches.
Recommended accessories 3000 X-Series
LAN/VGA connection module DSOXLAN GPIB connection module DSOXGPIB Rack mount kit N6456A
Soft carrying case and front panel cover N6457A Hard copy manual N6459A Front panel cover only N2747A
21
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Performance characteristics
DSOX3000 Series (digital signal oscilloscope) MSOX3000 Series (mixed signal oscilloscope)
DSOX3012A
MSOX3012A
Characteristics
Bandwidth*
100 MHz 100 MHz 200 MHz 350 MHz 350 MHz 500 MHz 500 MHz 1 GHz 1 GHz
(-3dB) Analog input
channels Calculated rise
≤ 3.5 ns ≤ 3.5 ns ≤ 1.75 ns ≤ 1 ns ≤ 1 ns ≤ 700 ps ≤ 700 ps ≤ 450 ps ≤ 450 ps
time
Hardware bandwidth limits 20 MHz selectable Input coupling AC, DC Input impedance Selectable: 1 MΩ ± 1%; II 14 pF, 50 Ω ± 1.5% Input sensitivity range 100 MHz to 500 MHz: 1 mV/div to 5 V/div** (1 MΩ and 50 Ohm)
Maximum sample rate 2 GSa/s per channel, 4 GSa/s half-channel interleaved (100 to 500MHz models)
Maximum memory depth (record length)
Display 8.5-inch WVGA with 64 levels of intensity grading Waveform update rate (max) 1,000,000 waveforms/s Vertical resolution 8 bits Horizontal resolution 2.5 ps Maximum input voltage CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk
DC vertical accuracy ±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale] ** DC vertical gain accuracy* Channel-to-channel isolation > 100:1 from DC to maximum specified bandwidth of each model
Offset range
DC vertical offset accuracy ±0.1div ± 2mV ± 1% of offset setting
DSOX3014A
MSOX3014A
DSOX3024A
MSOX3024A
DSOX3032A
MSOX3032A
DSOX3034A
MSOX3034A
DSOX3052A
MSOX3052A
DSOX3054A
MSOX3054A
DSOX3102A
MSOX3102A
DSOX3104A
MSOX3104A
244242424
All 3000 X-Series models
1 GHz model: 1 mV/div to 5 V/div** (1 MΩ), 1mV/div to 1V/div (50 Ohm)
2.5 GSa/s, 5 GSa/s half-channel interleaved (1 GHz models) 1 Mpt per channel, 2 Mpts half-channel interleaved (standard),
2 Mpts per channel, 4 Mpts half-channel interleaved (optional with DSOX3MEMUP)
CAT II 300 Vrms, 400 Vpk With N2862A, N2863A or N2890A 10:1 probe: 300 Vrms
±2% full scale**
(measured with same V/div and coupling on channels)
±2 V (1 mV/div to 200 mV/div) ±50 V (> 200 mV/div to 5 V/div)
* Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature. ** 1 mV/div and 2 mV/div are a magnification of 4 mV/div setting. For vertical accuracy calculations, use full scale of 32 mV for 1 mV/div and 2 mV/div sensitivity setting.
22
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Performance characteristics
Vertical system digital channels
All MSO 3000 X-Series models and on all DSO 3000 X-Series models with after purchase upgrade
Characteristics
Digital input channels 16 digital (D0 to D15) Thresholds Threshold per set of 8 channels Threshold selections TTL (+1.4 V)
User-defined threshold range ±8.0 V in 10 mV steps Maximum input voltage ±40 V peak CAT I; transient overvoltage 800 Vpk Threshold accuracy* ±(100 mV + 3% of threshold setting) Maximum input dynamic range ±10 V about threshold Minimum voltage swing 500 mVpp Input impedance 100 kΩ ±2% II at probe tip Probe loading ~8 pF Vertical resolution 1 bit
5 V CMOS (+2.5 V) ECL (–1.3 V) User-definable (selectable by pod)
Horizontal system analog channels
All 3000 X-Series models
Characteristics
Maximum sample rate 4 GSa/s half-channel interleaved, 2 Gsa/s per channel (100 to 500MHz models)
Maximum record length 2 Mpts half-channel interleaved, 1 Mpts per channel (Standard)
Maximum duration of time captured at highest sample rate (all channels)
Time base range (s/div)
DSOX3012A
MSOX3012A
5 ns/div to 50 s/div
DSOX3014A
MSOX3014A
5 ns/div to 50 s/div
Time base delay time range Pre-trigger – Greater of 1 screen width or 250 µs
Channel-to-channel deskew range ± 100 ns Time base accuracy* 25 ppm ± 5 ppm per year (aging) ∆ Time accuracy (using cursors) ±(time base acc. x reading) ± (0.0016 x screen width) ± 100 ps Modes Main, zoom, roll, XY
5 GSa/s half-channel interleaved, 2.5 Gsa/s per channel (1GHz models)
4 Mpts half-channel interleaved, 2 Mpts per channel (Optional with DSOX3MEMUP) 500Kpts (analog and digital channels) with 4M memory upgrade (DSOX3MEMUP)
DSOX3024A
MSOX3024A
2 ns/div to 50 s/div
DSOX3032A
MSOX3032A
2 ns/div to 50 s/div
DSOX3034A
MSOX3034A
2 ns/div to 50 s/div
DSOX3052A
MSOX3052A
1 ns/div to 50 s/div
DSOX3054A
MSOX3054A
1 ns/div to 50 s/div
DSOX3102A
MSOX3102A
500 ps/div to 50 s/div
All 3000 X-Series models
Post-trigger – 1 s to 500 s
DSOX3104A
MSOX3104A
500 ps/div to 50 s/div
XY On channels 1 and 2 only Z Blanking on Ext Trigger Input, 1.4 V threshold Bandwidth:
Maximum bandwidth Phase error at 1 MHz: < 0.5 degree
* Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.
23
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Performance characteristics
Horizontal system digital channels
All MSO models and DSO models with MSO upgrade
Characteristics
Maximum sample rate 1 GSa/s; 1.25 GSa/s (1 GHz models) Maximum record length 1 Mpts per channel standard, max 1.25 GSa/s for the 1 GHz model (with digital channels only)
2 Mpts per channel with DSOX3MEMUP memory upgrade option(with digital channels only) Minimum detectable pulse width 5 ns Channel-to-channel skew 2 ns (typical); 3 ns (maximum)
Trigger system
All 3000 X-Series models
Characteristics
Trigger modes • Normal (triggered): requires trigger event for scope to trigger
• Auto: triggers automatically in absence of trigger event
• Single: triggers only once on a trigger event, press [Single] again for scope to find another trigger event, or press [Run] to trigger continuously in either Auto or Normal mode
• Force: front panel button that forces a trigger
Trigger coupling DC: DC coupled trigger
AC: AC coupled trigger, cutoff frequency: < 10 Hz (internal); <50 Hz (external) HF Reject: High frequency reject, cutoff frequency ~ 50 kHz LF Reject: Low frequency reject, cutoff frequency ~ 50 kHz Noise Reject: Selectable OFF or ON, decreases sensitivity 2x
Trigger holdoff range 40 ns to 10.00 s
Trigger sensitivity
Internal* <10 mV/div: greater of 1 div or 5 mV; ≥ 10 mV/div: 0.6 div External* 200 mVpp from DC to 100 MHz
350 mVpp 100 MHz to 200 MHz
Trigger level range
Any channel ± 6 div from center screen External ± 8 V
* Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.
24
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Performance characteristics
Trigger type selections
All 3000 X-Series models
Characteristics
Edge Trigger on a rising, falling, alternating or either edge of any source Pulse width Trigger on a pulse on a selected channel, whose time duration is less than a value, greater
Runt Trigger on a position runt pulse that fails to exceed a high level threshold. Trigger on a
Setup and hold Trigger and clock/data setup and/or hold time violation from < 0.0 to 10 s Rise/fall time Trigger on rise time or fall time edge speed violations (< or >) based on user-selectable
th
edge bust Trigger on the Nth edge of a burst that occurs after a specified idle time.
N Pattern Trigger when a specified pattern of high, low, and don’t care levels on any combination of
Time-qualified pattern Trigger on a multi-channel pattern whose time duration is less than a value, greater than a
OR Trigger Trigger on any selected edge across multiple analog or digital channels Edge then Edge (B Trigger) Arm on a selected edge, wait a specified time, then trigger on a specified count of
Video (Standard) Trigger on all lines or individual lines, odd/even or all fields from composite video, or
Enhanced Video (optional) Trigger on lines and fields of enhanced and HDTV standards (480p/60, 567p/50, 720p/50,
USB Trigger on start of packet, end of packet, reset complete, enter suspend, or exit suspend.
2
C (optional) Trigger on I2C (Inter-IC bus) serial protocol at a start/stop condition or user defined frame
I
than a value, or inside a time range
• Minimum duration setting: 2 ns- 10 ns (depends on bandwidth)
• Maximum duration setting: 10 s
negative runt pulse that fails to exceed a low level threshold. Trigger on either polarity runt pulse based on two threshold settings. Runt triggering can also be time-qualified (< or >) with a minimum time setting of 4 ns and maximum timesetting of 10 s.
threshold. Time settings range from (< or >) or 2 ns to 10 s.
analog, digital , or trigger channels is [entered | exited]. Pattern must have stabilized for a minimum of 2 ns to qualify as a valid trigger condition.
value, greater than a time value with a timeout, or inside or outside of a set of time values.
• Minimum duration setting: 2 ns - 10 ns (depends on bandwidth)
• Maximum duration setting: 10 s
another selected edge
broadcast standards (NTSC, PAL, SECAM, PAM-M)
720p/60, 1080p/24, 1080p/25, 1080p/30, 1080p/50, 1080p/60, 1080i/50, 1080i/60).
Support USB low-speed and full-speed.
with address and/or data values. Also trigger on missing acknowledge, address with no accq, restart, EEPROM read, and 10-bit write.
SPI (optional) Trigger on SPI (Serial Peripherial Interface) data pattern during a specific framing period.
RS-232/422/485/UART (optional) Trigger on Rx or Tx start bit, stop bit or data content
I²S (optional) Trigger on 2’s complement data of audio left channel or right channel (=, ≠, <, >, > <, < >,
CAN (optional) Trigger on CAN (controller area network) version 2.0A and 2.0B signals. Trigger on the start
LIN (optional) Trigger on LIN (Local Interconnect Network) sync break, sync frame ID, or frame ID and data.
FlexRay (optional) Trigger on FlexRay signals based on frame ID, frame type (sync, start-up, null, normal), cycle-
MIL-STD 1553 (optional) Trigger on MIL-STD 1553 signals based on word type (Data or Command/Status), Remote
ARINC 429 (optional) Trigger on ARINC 429 signals based on label, data, and errors (parity, word, gap).
Supports positive and negative Chip Select framing as well as clock Idle framing and user­specified number of bits per frame.
increasing value, or decreasing value)
of frame (SOF) bit (standard). Remote frame ID (RTR), data frame ID (~RTR), remote or data frame ID, data frame ID and data, error frame, all errors, acknowledge error and overload frame.
repetitive, cycle-base, and errors.
Terminal Address, data, and errors (parity, sync, Manchester encoding).
25
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Performance characteristics
Acquisition modes
All 3000 X-Series models
Characteristics
Normal Peak detect Capture glitches as narrow as 250-ps at all timebase settings Averaging Selectable from 2, 4, 8, 16, 64, ... to 65,536 High Resolution Mode 12 bits of resolution when ≥10 µs/div at 4 GSa/s and 5 GSa/s (1 GHz models) or ≥20-µs/div
at 2 GSa/s
Segmented (optional) Re-arm time = 1 µs (minimum time between trigger events)
Waveform measurements
All 3000 X-Series models
Characteristics
Cursors** • Single cursor accuracy:
±[DC vertical gain accuracy + DC vertical offset accuracy + 0.25% full scale]
• Dual cursor accuracy:
±[DC vertical gain accuracy + 0.5% full scale]*
• Units: Seconds(s), Hz (1/s), Phase (degrees), Ratio (%)
Automatic measurements Measurements continuously updated with statistics. Cursors track last selected
measurement. Select up to four measurements from the list below:
• Voltage: peak-to-peak, maximum, minimum, amplitude, top, base, overshoot, pre-shoot,
average- N cycles, average- full screen, DC RMS- N cycles, DC RMS- full screen, AC RMS- N cycles, AC RMS- full screen (standard deviation), ratio (RMS1/RMS2)
• Time: period, frequency, counter, + width, - width, burst width, duty cycle, rise time, fall time,
delay, phase, X at min Y, X at Max Y
• Count: positive pulse count, negative pulse count, rising edge count, falling edge count
• Mixed: area- N cycles, area- full screen
Counter Built-in frequency counter:
• Source: on any analog or digital channel
• Resolution: 5 digits
• Maximum frequency: bandwidth of scope
Waveform math
All 3000 X-Series models
Characteristics
Arithmetic f (g(t))
g(t): { add, subtract, multiply between any 2 channels} f(t): {FFT(g(t)), differentiate d/dt g(t), integrate ∫ g(t) dt, square root √g(t) } Enabled between any combination of two channels
Arithmetic DSOX3ADVMath advanced waveform math option adds Ax + B, Square, Absolute,
Common Log, Natural Log, Exponential, Base 10 Exponential, LP Filter, HP Filter, Magnify, Measurement Trend, Chart Logic Bus (Timing or State).
FFT Up to 64 kpts resolution
Set FFT Window to: Hanning, Flat Top, Rectangular, Blackman-Harris
* Denotes warranted specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature. ** 1 mV/div and 2 mV/div is a magnification of 4 mV/div setting. For vertical accuracy calculations, use full scale of 32 mV for 1 mV/div and 2 mV/div sensitivity setting.
26
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Performance characteristics
Display characteristics
All 3000 X-Series models
Characteristics
Display 8.5-inch WVGA Resolution 800 (H) x 480 (V) pixel format (screen area) Graticules 8 vertical divisions by 10 horizontal divisions with intensity controls. Format YT and XY Maximum waveform update rate > 1,000,000 wfms/s Persistence Off, infinite, variable persistence (100 ms - 60 s) Intensity gradation 64 intensity levels
Input/output ports
All 3000 X-Series models
Port
USB 2.0 hi-speed host port Two USB 2.0 hi-speed host ports, front and real panel
Supports memory devices and printers USB 2.0 hi-speed device port One USB 2.0 hi-speed device port on rear panel LAN port 10/100Base-T (requires DSOXLAN module) Video out port Connect oscilloscope display to an external monitor or projector (requires DSOXLAN module) GPIB port To allow easy migration into existing test systems (requires DSOXGPIB) Probe compensator output Square wave: 2.5 Vpp, 1 kHz Kensington style lock Rear-panel security slot connects to standard Kensington-style lock WaveGen out Front-Panel BNC Connector
WaveGen – Built-in function/arbitrary waveform generator
Waveforms Sine, Square, Ramp, Pulse, DC, Noise, Sine Cardinal (Sinc), Exponential Rise, Exponential Fall,
Cardiac, Gaussian Pulse, and Arbitrary.
Sine • Frequency range: 0.1 Hz to 20 MHz
• Amplitude flatness: ±0.5 dB (relative to 1 kHz)
• Harmonic distortion: –40 dBc
• Spurious (non harmonics): –40 dBc
• Total harmonic distortion: 1%
• SNR (50 ohm load, 500 MHz BW) : 40 dB (Vpp > = 0.1 V); 30 dB (Vpp < 0.1V)
Square wave /pulse • Frequency range: 0.1 Hz to 10 MHz
• Duty cycle: 20 to 80%
• Duty cycle resolution: Larger of 1% or 10 ns
• Pulse width: 20 ns minimum
• Rise/fall time: 18 ns (10 to 90%)
• Pulse width resolution: 10 ns or 5 digits, whichever is larger
• Overshoot: < 2%
• Asymmetry (at 50% DC): ±1% ± 5 ns
• Jitter (TIE RMS): 500 ps
Ramp/triangle wave • Frequency range: 0.1 Hz to 200 kHz
• Linearity: 1%
• Variable symmetry: 0 to 100%
• Symmetry resolution: 1%
Noise Bandwidth: 20 MHz typical
27
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
Performance characteristics
WaveGen – Built-in function/arbitrary waveform generator
Sine Cardinal (Sinc) Frequency range: 0.1 Hz to 1.0 MHz Exponential Rise/Fall Frequency range: 0.1 Hz to 5.0 MHz Cardiac Frequency range: 0.1 Hz to 200.0 kHz Gaussian Pulse Frequency range: 0.1 Hz to 5.0 MHz Arbitrary • Waveform length: 1 to 8k points
• Amplitude Resolution: 10 bits (including sign bit)***
• Repetition Rate: 0.1Hz to 12MHz
• Sample Rate: 100 MSa/s
• Filter Bandwidth: 20 MHz
Frequency • Sine wave and ramp accuracy:
◦ 130 ppm (frequency < 10 kHz) ◦ 50 ppm (frequency > 10 kHz)
• Square wave and pulse accuracy: ◦ [50+frequency/200] ppm (frequency < 25 kHz) ◦ 50 ppm (frequency ≥ 25 kHz)
• Resolution: 0.1 Hz or 4 digits, whichever is larger
Amplitude • Range:
◦ 20 mVpp to 5 Vpp into Hi-Z** ◦ 10 mVpp to 2.5 Vpp into 50 ohms**
• Resolution: 100 μV or 3 digits, whichever is higher
• Accuracy: 2% (frequency = 1 kHz)
DC offset • Range:
◦ ±2.5 V into Hi-Z** ◦ ±1.25 V into 50 ohms**
• Resolution: 100 μV or 3 digits, whichever is higher
• Accuracy: ±1.5% of offset setting ±1.5% of amplitude ±1 mV
Trigger output Trigger output available on Trig out BNC Main Output • Impedance : 50 ohms typical
• Isolation: not available, main output BNC is grounded
• Protection: overload automatically disables output
* Gaussian Pulse: 4 Vpp maximum into Hi-Z; 2 Vpp maximum into 50 ohms. ** Sinc, Cardiac and Gaussian Pulse: ±1.25 V into Hi-Z; +- 625 mV into 50ohms *** Full resolution is not available at output due to internal attenuator stepping.
Integrated digital voltmeter
Functions ACrms, DC, DCrms, Frequency
Resolution ACV/DCV: 3 digits Frequency: 5.5 digits Measuring Rate 100 times/ second Autoranging Automatic adjustment of vertical amplification to maximize the dynamic range of measurements. Range Meter Graphical display of most recent measurement, plus extrema over the previous 3 seconds.
Measurement Range
Frequency Range Vertical Range
ACRms 20 Hz-100KHz 100 MHz to 500 MHz: 1 mV/div to 5 V/ DCRms 20 Hz-100KHz [DC vertical gain accuracy + DC vertical offset
DC NA [DC vertical gain accuracy + DC vertical offset
Frequency counter
1Hz – BW of Scope <10 mV/div: greater of 1 div or 5 mV; ≥
div** (1 MΩ and 50 Ohm) 1 GHz model: 1 mV/div to 5 V/div** (1 MΩ), 1mV/div to 1V/div (50 Ohm)
10 mV/div: 0.6 div
28
Vertical Accuracy
[
DC vertical gain accuracy + 0.5% full scale
accuracy + 0.25% full scale]
accuracy + 0.25% full scale] 25 ppm ± 5 ppm per year (aging)
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
InfiniiVision X-Series physical characteristics
Instrument
Dimensions mm Inches
Width 380.6 14.98 Height 204.4 8.05 Depth 141.5 5.57
Weight kg lb
Instrument only 3.85 8.5 With accessories 4.08 9.0
Instrument shipping – package dimensions mm Inches
Width 450 17.7 Height 250 9.84 Depth 360 14.17
Rack mount mm Inches
Width 481.6 18.961 Height 221.5 8.72 Depth 189.34 7.454
Environmental
Characteristic
Power line consumption 100 watts Temperature Operating: 0 to +55 °C
Nonoperating: -30 to +71 °C
Humidity Operating: Up to 80% RH at or below +40 °C; up to 45% RH up to +50 °C
Non-operating: Up to 95% RH up to 40 °C; up to 45% RH up to 50 °C Altitude Operating and non-operating: up to 4,000 m Electromagnetic compatibility Meets EMC Directive (2004/108/EC), meets or exceeds IEC 61326-1:2005/EN
61326-1:2006 Group 1 Class A requirement
CISPR 11/EN 55011
IEC 61000-4-2/EN 61000-4-2
IEC 61000-4-3/EN 61000-4-3
IEC 61000-4-4/EN 61000-4-4
IEC 61000-4-5/EN 61000-4-5
IEC 61000-4-6/EN 61000-4-6
IEC 61000-4-11/EN 61000-4-11
Canada: ICES-001:2004
Australia/New Zealand: AS/NZS Safety UL61010-1 2nd edition, CAN/CSA22.2 No. 61010-1-04 Vibration Meets IEC60068-2-6 and MIL-PRF-28800; class 3 random Shock Meets IEC 60068-2-27 and MIL-PRF-28800; class 3 random;(operating 30g,
½ sine. 11 ms duration, 3 shocks/axis along major axis, total of 18 shocks
29
Oscilloscopes redefined: Breakthrough technology delivers more scope for the same budget
InfiniiVision X-Series physical characteristics
Connectivity
Standard ports One USB 2.0 high-speed device port on rear panel
Two USB 2.0 high-speed host ports, front and rear panel
Supports memory devices and printers Optional ports GPIB, LAN, VGA
Nonvolatile storage
Reference waveform display 2 internal waveforms or USB thumb drive Waveform storage Setup, .bmp, .png, .csv, ASCII, XY, reference
waveforms .alb, .bin, lister, mask, HDFS Max USB flash drive size Supports industry standard flash drives Set ups without USB flash drive 10 internal setups Set ups with USB flash drive Limited by size of USB drive
Accessories included
Standard 3- year warranty Standard SEC mode (Secure Environment)
Certificate of Calibration Documentation CD
Standard Probe N2862B Passive probe 150 MHz 10:1 attenuation 1 per channel included 100 MHz models N2863B Passive probe 300 MHz, 10:1 attenuation 1 per channel included 200 MHz models N2890A Passive probe 500 MHz, 10:1 attenuation 1 per channel included 350/500 MHz and 1 GHz models N6450-60001 16 digital channel MSO cable 1 per scope included on all MSO models and
DSOX3MSO (for 500 MHz models and below) DSOX3PERFMSO (for 1 GHz Models)
Built-in help language support for English, Japanese, simplified Chinese, traditional Chinese, Korean, German, French, Spanish, Russian, Portuguese and Italian
Interface language support
GUI menus: English, Japanese, simplified Chinese, traditional Chinese, Korean, German, French, Spanish, Russian, Portuguese and Italian
Localized power cord
For MET/CAL procedures, click on the Cal Labs solutions link below
http://www.callabsolutions.com/MetCALandCLS.asp
These procedures are FREE to customers
Related literature
Publication title Publication type Publication number
Serial Bus Applications for Agilent InfiniiVision 3000 X-Series Oscilloscopes
Power Measurements for Agilent InfiniiVision 3000 X-Series oscilloscope
Mask/Waveform Limit Testing For Agilent InfiniiVision Series Oscilloscopes
30
Data sheet 5990-6677EN Data sheet 5990-8869EN Data sheet 5990-3269EN
Probe Compatibility Table
To assist you in selecting the proper probe for your application: Use our probe compatibility table below to find the probes
that are recommended for use with your 2000 and 3000 X-Series InfiniiVision oscilloscope. For more information about the probes and accessories for InfiniiVision Series oscilloscope, check out the InfiniiVision oscilloscope probes and acces­sories data sheet with the Agilent literature number, 5968-8153EN.
Probe Type Probe Model MSO/DSO
2000 X-Series
Passive probes, N2862B 10:1 150 MHz
(included in 70/100 MHz models) N2863B 10:1 300 MHz (included in 200 MHz models) N2890A 10:1 500 MHz (included in 350/500 MHz and 1 GHz models models)
N2889A 1:1/10:1 350 MHz Recommended Recommended
High-voltage passive probes, 10076B 4 kV Recommended Recommended
N2771B 30 kV Recommended Recommended
Differential active probes, 1130A 1.5 GHz Incompatible Compatible
1141A 200 MHz (use with 1142A) Incompatible Recommended N2791A 25 MHz Recommended Recommended N2891A 70 MHz Recommended Recommended N2790A 100 MHz (with AutoProbe) Incompatible Recommended N2792A 200 MHz Recommended N2793A 800 MHz Recommended
Single-ended active probes, N2795A 1 GHz (with AutoProbe) Incompatible Recommended (limit 2)
1157A 2.5 GHz (with AutoProbe) Recommended Recommended
MSO logic probes, 01650-61607 16-channel Incompatible Compatible
N6459-60001 8-channel MSO cable (included in 2000 X-Series MSOs)
N6450-60002 16-channel MSO cable (included in 3000 X-Series MSOs)
Current probes, 1146A 100 kHz Recommended Recommended
N2780B 2 MHz (use with N2779A) Recommended Recommended N2781B 10 MHz (use with N2779A) Recommended Recommended N2782B 50 MHz (use with N2779A) Recommended Recommended N2783B 100 MHz (use with N2779A) Recommended Recommended 1147A 50 MHz (with AutoProbe) Incompatible Recommended N2893A 100 MHz (with AutoProbe) Incompatible Recommended
Recommended Recommended
Recommended Compatible
Incompatible Recommended
1
2
2
MSO/DSO 3000 X-Series
Recommended Recommended
1. The 2000 X-Series does not support AutoProbe interface active probes.
2. Use a 50 ohm feedthrough terminator.
31
Oscilloscopes redefi ned: Breakthrough technology delivers more scope for the same budget
License-only bandwidth upgrades and measurement applications
Entitlement
certificate
Agilent sales
partner
USB drive containing
Stick-0n
label sheet
(for bandwidth
upgrades)
license file
Agilent software
licensing website
Customer
5
Email containing
attached licensed file
Bandwidth Upgrade Models
3000 X-Series
DSOX3BW24 100 MHz to 200 MHz, 4 ch, License only
DSOX3BW32* 100 MHz to 350 MHz, 2 ch, Service center DSOX3BW34* 200 MHz to 350 MHz, 4 ch, Service center
DSOX3BW52 350 MHz to 500 MHz, 2 ch, License only
DSOX3BW54 350 MHz to 500 MHz, 4 ch, License only
DSOX3BW12 500 MHz to 1 GHz, 2 ch, Service center DSOX3BW14 500 MHz to 1 GHz, 2 ch, Service center
Measurement Applications
DSOX3WAVEGEN WaveGen (built -in function generator with AWG) DSOXDVM Integrated digital voltmeter DSOXEDK Educator’s kit DSOX3MASK Mask testing DSOX3SGM Segmented memory DSOX3ADVMATH Advanced waveform math DSOX3VID Enhanced video triggering DSOX3EMBD Embedded serial triggering and analysis (I DSOX3COMP Computer serial triggering and analysis
(RS232/422/485/UART) DSOX3AUDIO Audio serial triggering and analysis (I DSOX3AUTO Automotive serial triggering and analysis
(CAN, LIN) DSOX3FLEX FlexRay serial triggering and analysis DSOX3AERO Aerospace serial triggering and analysis
(MIL-STD 1553, ARINC 429) DSOX3PWR Power measurements and analysis DSOX3MSO MSO upgrade: add 16 digital timing channels
2
C, SPI)
2
S)
Process Description
Place order for a license only bandwidth upgrade or measurement application product to an Agilent sales partner. If multiple bandwidth upgrade steps are needed, order all the corresponding upgrade products required to get from current bandwidth to desired bandwidth. In the case where the new bandwidth requires higher bandwidth passive probes, they are included with the upgrade. For the DSOX3BW24, the N2863B 10:1 300 MHz passive probes (1 per channel) will be sent with the upgrade. DSOX3BW32, DSOX3BW34, DSOX3BW52, DSOX3BW54, DSOX3BW12 and DSOX3BW14, the N2890A 10:1 500MHz passive probe (1 per channel) will be sent with the upgrade.
For measurement applications, you will receive a paper or electronic .pdf Entitlement Certifi cate. For bandwidth upgrades only, you will receive a stick-on label document indicating upgraded bandwidth specifi cation in addition to a paper Entitlement Certifi cate.
Use Entitlement Certifi cate containing instructions and certifi cate number needed to generate a license fi le for a particular 2000 or 3000 X-Series oscilloscope model number and serial number unit.
Receive the licensed fi le and installation instructions via email.
Copy license fi le (.lic extension) from email to a USB drive and follow instructions in email to install the purchased bandwidth upgrade or measurement application on the oscilloscope.
For bandwidth upgrades only, attach bandwidth upgraded stick-on label to front and rear panels of the oscilloscope. Model number and serial number of the oscilloscope do not change.
* See page 30 for return-to-Agilent service center upgrade process for these products
32
Oscilloscopes redefi ned: Breakthrough technology delivers more scope for the same budget
Return-to-Agilent Service Center Bandwidth Upgrades
Agilent Business
Center
Ship scope per
instructions
Agilent sales
partner
Bandwidth Upgrade Models
3000 X-Series
DSOX3BW24* 100 MHz to 200 MHz, 4 ch, License only
DSOX3BW32 100 MHz to 350 MHz, 2 ch, Service center
DSOX3BW34 200 MHz to 350 MHz, 4 ch, Service center
DSOX3BW52* 350 MHz to 500 MHz, 2 ch, License only DSOX3BW54* 350 MHz to 500 MHz, 4 ch, License only
DSOX3BW12 500 MHz to 1 GHz, 2 ch, Service center
DSOX3BW14 500 MHz to 1 GHz, 2 ch, Service center
Customer
Agilent service
center
Upgraded scope
shipped back
Process Description
Place order for a return-to-Agilent Service Center bandwidth upgrade product to an Agilent sales partner. Service Center installation cost is in addition to bandwidth upgrade product price. Service Center calibration is included in the bandwidth upgrade product price. If multiple upgrade steps are needed, order all the corresponding upgrade products required to get from current bandwidth to desired bandwidth. In the case where the new bandwidth requires higher bandwidth passive probes, they are included with the upgrade. For the DSOX3BW24, the N2863B 10:1 300 MHz passive probes (1 per channel) will be sent with the upgrade. DSOX3BW32, DSOX3BW34, DSOX3BW52, DSOX3BW54, DSOX3BW12 and DSOX3BW14, the N2890A 10:1 500MHz passive probe (1 per channel) will be sent with the upgrade.
Agilent Business Center will contact you regarding process and timing of the Service Center installation. Continue to use oscilloscope until contacted again later when parts are available at Service Center.
Ship the oscilloscope per provided instructions (freight paid by Agilent) to Service Center.
Service Center ships back upgraded oscilloscope with stick-on labels applied to front and rear panels indicating upgraded bandwidth specifi cation. Model number and serial number of the oscilloscope do not change.
* See page 29 for license-only upgrade process for these products
33
Agilent Technologies Oscilloscopes
Multiple form factors from 20 MHz to >90 GHz | Industry leading specs | Powerful applications
www.agilent.com
www.agilent.com/find/3000X-Series
Agilent Email Updates
www.agilent.com/find/emailupdates
Get the latest information on the products and applications you select.
www.axiestandard.org
AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA® for general purpose and semiconductor test. Agilent is a founding member of the AXIe consortium.
http://www.pxisa.org
PCI eXtensions for Instrumentation (PXI) modular instrumentation delivers a rugged, PC-based high­performance measurement and automation system.
Agilent Channel Partners
www. agilent.com/find/channelpartners
Get the best of both worlds: Agilent’s measurement expertise and product breadth, combined with channel partner convenience.
Agilent Advantage Services is com­mitted to your success throughout your equipment’s lifetime. We share measurement and service expertise to help you create the products that change our world. To keep you com­petitive, we continually invest in tools and processes that speed up calibra­tion and repair, reduce your cost of ownership, and move us ahead of your development curve.
www.agilent.com/find/advantageservices
www.agilent.com/quality
Microsoft® is a registered trademark of Microsoft Corporation in the United States and other countries.
For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent
office. The complete list is available at:
www.agilent.com/find/contactus
Americas
Canada (877) 894 4414 Brazil (11) 4197 3600 Mexico 01800 5064 800 United States (800) 829 4444
Asia Pacific
Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Other AP Countries (65) 375 8100
Europe & Middle East
Belgium 32 (0) 2 404 93 40 Denmark 45 45 80 12 15 Finland 358 (0) 10 855 2100 France 0825 010 700*
*0.125 €/minute
Germany 49 (0) 7031 464 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 United Kingdom 44 (0) 118 927 6201
For other unlisted countries:
www.agilent.com/find/contactus
Revised: January 6, 2012
Product specifications and descriptions in this document subject to change without notice.
© Agilent Technologies, Inc. 2012 Published in USA, April 12, 2012 5990-6619EN
Loading...