Agilent Inert Flow Path Solutions Reference Guide

Quick Reference Guide
Agilent Inert Flow Path Solutions
Agilent’s 7890B, 8890, and 8860 Inert Flow Path Split/Splitless Inlet option ensures the inertness of flow path surfaces, allowing analytes to safely pass from injector to detector. For best trace level analysis, maintain your Inert Flow Path with Agilent Inert Flow Path components.
Agilent Ultra Inert liners and touchless packaging
High inertness, productivity, and reproducibility
Description Volume (μL) ID (mm) 1/pk 5/pk 25/pk 100/pk*
Single taper, Ultra Inert liner
Single taper, Ultra Inert liner with glass wool
900 4 5190-2292 5190-3162 5190-3166 5190-3170
900 4 5190-2293 5190-3163 5190-3167 5190-3171
Double taper, Ultra Inert liner
Dimpled
Splitless, UI, fritted liner, low
Inlet liner, UI, splitless, straight
Split Inlet Liners
Straight, Ultra Inert liner with glass wool
Low pressure drop, Ultra Inert liner with glass wool
Inlet liner, universal, UI, mid-frit
SPME, Headspace Injection
Straight Ultra Inert liner for SPME
Straight, Ultra Inert liner
Each liner ships with a preinstalled, nonstick O-ring. *The 100/pk is not in the touchless packaging. O-rings must be purchased separately.
800 4 5190-3983 5190-4007
200 2 5190-2297 5190-4006
870 4 5190-5112 5190-5112-005 5190-5112-025
250 2 5190-6168
990 4 5190-2294 5190-3164 5190-3168 5190-3172
870 4 5190-2295 5190-3165 5190-3169 5190-3173
870 4 5190-5105 5190-5105-005 5190-5105-025
35 0.75 5190-4048
65 1 5190-4047
Agilent Ultra Inert gold seals and washers
A smooth, leak-free surface for active analytes
Description 1/pk 10/pk 50/pk
Ultra Inert gold seal and washer
5190-6144 5190-6145 5190-6149
Agilent UltiMetal Plus and gold-plated Flexible Metal ferrules
No column breakage, no leaks, no activity
Description Unit Part No.
UltiMetal Plus Flexible Metal ferrule with 0.4 mm id For fused silica tubing 0.1-0.25 mm id
UltiMetal Plus Flexible Metal ferrule with 0.5 mm id For fused silica tubing 0.32 mm id
UltiMetal Plus Flexible Metal ferrule with 0.8 mm id For fused silica tubing 0.45-0.53 mm id
UltiMetal Plus Flexible Metal ferrule with no hole To plug capillary flow technology fittings
UltiMetal Plus Flexible Metal ferrule Use with 0.25 mm and 0.32 mm UltiMetal column tubing
UltiMetal Plus Flexible Metal ferrule Use with 0.53 mm UltiMetal column tubing
Gold-plated Flexible Metal ferrule with 0.4 mm id For fused silica tubing 0.1-0.25 mm id
Gold-plated Flexible Metal ferrule with 0.5 mm id For fused silica tubing 0.32 mm id
Gold-plated Flexible Metal ferrule with 0.8 mm id For fused silica tubing 0.45 - 0.53 mm id
Gold-plated Flexible Metal ferrule Use with 0.25 and 0.32 mm UltiMetal column tubing
Gold-plated Flexible Metal ferrule Use with 0.53 mm UltiMetal column tubing
10/pk G3188-27501
10/pk G3188-27502
10/pk G3188-27503
10/pk G3188-27504
10/pk G3188-27505
10/pk G3188-27506
10/pk G2855-28501
10/pk G2855-28502
10/pk G2855-28503
10/pk G2855-28505
10/pk G2855-28506
Agilent Inert Flow Path upgrade kit
The components you need, all in one place
Description Part No.
Complete Agilent Inert Flow Path upgrade kit G3970A
Capillary inlet shell weldment assembly, UltiMetal Plus treated G3452-60570
Insert weldment, UltiMetal Plus treated G3452-60586
Ultra Inert gold seal 5190-6144
Ultra Inert single taper splitless liner with wool 5190-2293
UltiMetal ferrules for 0.25 mm id fused silica columns, 10/pk G3188-27501
Self-Tightening column nut, inlet/detector nut G3440-81011
Self-Tightening column nut, MSD G3440-81013
Four easy ways to create your inert flow path:
1. Request Option 114 when you purchase either the Agilent 7890B GC or 8890 GC system.
2. Add an Inert Flow Path Split/ Splitless Inlet to your 7890 with accessory p/n G3453B. For the 8890, order p/n G3549A*.
3. Upgrade a 7890 Split/Splitless Inlet with inert components (p/n G3970A).
4. Purchase individual Inert Flow Path components separately, as needed.
* Contact your local Agilent representative
for more information.
Additional flow path supplies
Expand the capabilities of your inert flow path
Description Part No.
Purged Ultimate Union assembly, inert G3186-60581
3-way splitter with makeup gas, inert G3183-60501
Ultimate Union kit, UltiMetal Plus deactivated G3182-60581
Compact Deans switch manifold assembly, UltiMetal Plus treated G2855-60501
Compact splitter with makeup gas, inert G3180-60501
2
Agilent J&W Ultra Inert GC columns
Engineered for low bleed, high thermal stability, and excellent inertness
DB-1ms Ultra Inert
ID (mm) Length (m) Film (μm) Temp Limits (°C) Part No.
0.18 20 0.18 -60 to 325/350 121-0122UI
0.25 15 0.25 -60 to 325/350 122-0112UI
30 0.25 -60 to 325/350 122-0132UI
60 0.25 -60 to 325/350 122-0162UI
0.32 15 0.25 -60 to 325/350 123-0112UI
30 0.25 -60 to 325/350 123-0132UI
DB-35ms Ultra Inert
HP-1ms Ultra Inert
ID (mm) Length (m) Film (μm) Temp Limits (°C) Part No.
0.18 20 0.18 -60 to 325/350 19091S-677UI
0.25 15 0.25 -60 to 325/350 19091S-931UI
30 0.25 -60 to 325/350 19091S-933UI
0.50 -60 to 325/350 19091S-633UI
1.00 -60 to 325/350 19091S-733UI
0.32 15 0.25 -60 to 325/350 19091S-911UI
25 0.52 -60 to 325/350 19091S-612UI
30 0.25 -60 to 325/350 19091S-913UI
1.00 -60 to 325/350 19091S-713UI
DB-5ms Ultra Inert
ID (mm) Length (m) Film (μm) Temp Limits (°C) Part No.
0.18 20 0.18 -60 to 325/350 121-5522UI
0.36 -60 to 325/350 121-5523UI
0.25 15 0.25 -60 to 325/350 122-5512UI
1.00 -60 to 325/350 122-5513UI
25 0.25 -60 to 325/350 122-5522UI
30 0.25 -60 to 325/350 122-5532UI
0.50 -60 to 325/350 122-5536UI
1.00 -60 to 325/350 122-5533UI
50 0.25 -60 to 325/350 122-5552UI
60 0.25 -60 to 325/350 122-5562UI
1.00 -60 to 325/350 122-5563UI
0.32 30 0.25 -60 to 325/350 123-5532UI
0.50 -60 to 325/350 123-5536UI
1.00 -60 to 325/350 123-5533UI
60 1.00 -60 to 325/350 123-5563UI
HP-5ms Ultra Inert
ID (mm) Length (m) Film (μm) Temp Limits (°C) Part No.
0.18 20 0.18 -60 to 325/350 19091S-577UI
0.25 15 0.25 -60 to 325/350 19091S-431UI
30 0.25 -60 to 325/350 19091S-433UI
0.50 -60 to 325/350 19091S-133UI
1.00 -60 to 325/350 19091S-233UI
60 0.25 -60 to 325/350 19091S-436UI
0.32 30 0.25 -60 to 325/350 19091S-413UI
1.00 -60 to 325/350 19091S-213UI
DB-624 Ultra Inert
DB-Select 624 UI for <467>
DB-UI 8270D Ultra Inert
*Only available in the U. S.
ID (mm) Length (m) Film (μm) Temp Limits (°C) Part No.
0.18 20 0.18 50 to 340/360 121-3822UI
0.25 15 0.25 50 to 340/360 122-3812UI
30 0.25 50 to 340/360 122-3832UI
0.32 30 0.25 50 to 340/360 123-3832UI
ID (mm) Length (m) Film (μm) Temp Limits (°C) Part No.
0.18 20 1.00 -20 to 260 121-1324UI
0.25 30 1.40 -20 to 260 122-1334UI
60 1.40 -20 to 260 122-1364UI
0.32 30 1.80 -20 to 260 123-1334UI
60 1.80 -20 to 260 123-1364UI
0.53 30 3.00 -20 to 260 125-1334UI
75 3.00 -20 to 260 125-1374UI
ID (mm) Length (m) Film (μm) Temp Limits (°C) Part No.
0.25 30 1.40 40 to 260 122-0334UI
60 1.40 40 to 260 122-0364UI
0.32 30 1.80 40 to 260 123-0334UI
60 1.80 40 to 260 123-0364UI
0.53 30 1.80 40 to 260 125-0334UI
ID (mm) Length (m) Film (μm) Temp Limits (°C) Part No.
0.18 20 0.36 -60 to 325/350 121-9723
0.25 30 0.25 -60 to 325/350 123-0334UI
-60 to 325/350 122-9732, 6/pk*
0.50 -60 to 325/350 122-9736
3
Agilent J&W Ultra Inert GC columns
Engineered for low bleed, high thermal stability, and excellent inertness
DB-WAX Ultra Inert
ID (mm) Length (m) Film (μm) Configuration Part No.
0.18 20 0.18 7 in. 121-7022UI
0.30 7 in. 121-7023UI
0.20 25 0.20 7 in. 128-7022UI
0.25 15 0.25 7 in. 122-7012UI
30 0.25 7 in. 122-7032UI
0.25 Intuvo 122-7032UI-INT
0.50 7 in. 122-7033UI
0.50 Intuvo 122-7033UI-INT
60 0.25 7 in. 122-7062UI
0.25 Intuvo 122-7062UI-INT
0.50 7 in. 122-7063UI
0.32 15 0.25 7 in. 123-7012UI
30 0.25 7 in. 123-7032UI
0.25 Intuvo 123-7032UI-INT
0.50 7 in. 123-7033UI
0.50 Intuvo 123-7033UI-INT
60 0.25 7 in. 123-7062UI
0.50 7 in. 123-7063UI
0.50 Intuvo 123-7063UI-INT
0.53 15 1.00 7 in. 125-7012UI
30 0.25 7 in. 125-7031UI
0.50 7 in. 125-7037UI
1.00 7 in. 125-7032UI
60 1.00 7 in. 125-7062UI
DB-FATWAX Ultra Inert
ID (mm) Length (m) Film (μm) Configuration Part No.
0.18 20 0.18 7 in. G3903-63007
0.18 Intuvo G3909-63002
0.25 30 0.25 7 in. G3903-63008
0.25 Intuvo G3909-63003
0.32 30 0.25 7 in. G3903-63009
0.50 Intuvo G3909-63004
DB-BAC1 Ultra Inert and DB-BAC2 Ultra Inert
ID (mm) Length (m) Film (μm) Config. Phase Part No.
0.32 30 1.20 7 in. DB-BAC1 123-9334UI
1.20 Intuvo DB-BAC1 123-9334UI-INT
1.80 7 in. DB-BAC2 123-9434UI
1.80 Intuvo DB-BAC2 123-9434UI-INT
0.53 30 2.00 7 in. DB-BAC2 125-9434UI
3.00 7 in. DB-BAC1 125-9334UI
HP-5ms Ultra Inert with Smart Key (For 8890 GC system only)
ID (mm) Length (m) Temp Limits (°C) Part No.
0.25 15 -60 to 325/350 19091S-431UI-KEY
30 -60 to 325/350 19091S-433UI-KEY
DB-5ms Ultra Inert with Smart Key (For 8890 GC system only)
ID (mm) Length (m) Temp Limits (°C) Part No.
0.25 30 -60 to 325/350 122-5532UI-KEY
Detector jets
Description Part No.
FID jet, universal fit, 0.011 inch id 5200-0176
FID jet, universal fit, 0.018 inch id 5200-0177
FID jet, universal fit, 0.030 inch id 5200-0178
NPD jet, universal fit, 0.011 inch id 5200-0179
www.agilent.com/chem/ultrainert
DE44151.4488541667
This information is subject to change without notice.
© Agilent Technologies, Inc. 2021 Printed in the USA, January 2, 2021 5991-2381EN