Agilent E6003B Data Sheet

Field Installation & Maintenance
394
HP 8147 HP E6000A
Optical Time Domain Reflectometer
• High resolution and dynamic range in each module
• Pre-programmable procedures
• Full on-line analysis and remote operation
• Exceptionally flexible
HP 8147
HP 8147 Optical Time Domain Reflectometer 1
8
The HP 8147 is a high performance optical time domain reflectometer for installation, commissioning and bench applications. It is designed for fast and accurate measurement and analysis of a fiber link, all at the touch of a single button.
“Easy Mode” lets you pre-program complete procedures, so that with a couple of keystrokes, you get standardized measurements. That way, regardless of the operator’s experience level, you get accurate and repeatable results ever y time.
Extended in-depth analysis including two-way measurements, delta measurements and comparison of up to four traces, is now avail­able online. A return loss graph allows you to see the reflectance of indi­vidual events at a glance, as well as the total return loss of the link.
The HP 8147 remote ability provides the centralized operation, collection and analysis of results from remotely-stationed OTDRs. As a result, you can maximize the use of scarce test expertise throughout your network.
At only 9 kg (20 lbs), the HP 8147 can be carried easily into those awkward places.
A variety of performance classes can now be selected to ensure you have just the right performance for your application. Many stan­dard interfaces and options are available to ensure that the OTDR can be configured to your exact needs.
Specifications
HP 8147 Dynamic Attenuation OTDR Wavelength Fiber Type Range (typ) Deadzone (typ)
HP E4311A 1310 ± 15 nm Single-mode 30 dB 10 m HP E4312A 1550 ± 15 nm Single-mode 30 dB 12 m HP E4313A 1310/1550 ± 15 nm Single-mode 30/30 dB 10/12 m HP E4314A 1310 ± 15 nm Single-mode 35 dB 10 m HP E4315A 1550 ± 15 nm Single-mode 34 dB 12 m HP E4316A 1310/1550 ± 15 nm Single-mode 35/34 dB 10/12 m HP E4317A 1310 ± 15 nm Single-mode 40 dB 10 m HP E4318A 1550 ± 15 nm Single-mode 39 dB 12 m HP E4319A 1310/1550 ± 15 nm Single-mode 40/39 dB 10/12 m HP E4321A 1625 ± 15 nm Single-mode 42 dB 14 m HP E4324A 1310/1550 ± 15 nm Single-mode 45/43 dB 10/12 m
Key Literature
HP 8147 Optical Time Domain Reflectometer, Technical Specifications
p/n 5964-1986E HP 8147 Optical Time Domain Reflectometer, Configuration Guide
p/n 5964-1987E
• Fast and accurate fault characterization
• One button automatic measurement and analysis
• Small, rugged and lightweight
• Excellent resolution
• Ultra high dynamic range
HP E6000B and modules
Ordering Information
At least one user-exchangeable connector interface (HP 81000xI) is required for the module.
HP E4310A Optical time domain reflectometer mainframe
Opt 001 DC input: 11–30 V Opt 002 Thermal printer Opt 003 Color screen, VGA-LCD Opt 004 HP-IB interface Opt 005 LAN interface
Opt AB2 Chinese user interface HP E4311A 1310 nm single-mode module (30 dB) HP E4312A 1550 nm single-mode module (30 dB) HP E4313A 1310/1550 nm single-mode module (30 dB) HP E4314A 1310 nm single-mode module (35 dB) HP E4315A 1550 nm single-mode module (34 dB) HP E4316A 1310/1550 nm single-mode module(35/34 dB) HP E4317A 1310 nm single-mode module (40 dB) HP E4318A 1550 nm single-mode module (39 dB) HP E4319A 1310/1550 nm single-mode module (40/39 dB) HP E4321A 1625 nm single-mode module (40 dB) HP E4324A 1310/1550 nm single-mode module (45/43 dB) HP E6090A ODTR Toolkit Software
HP E6000B Mini-Optical Time Domain Reflectometer
The HP E6000B mini-OTDR maximizes your network uptime by locat­ing and characterizing faults quickly and accurately. The unrivalled combination of 16,000 data points and a minimum sample spacing of 8 cm allows the powerful analysis algorithm to determine the exact loca­tion and characteristic of an event. Add to this the 20 m attenuation dead­zone, and you really can measure and resolve closely-spaced events along the whole fiber link.
Its one button operation, combined with its intuitive user inter­face, makes it easy even for those with minimal training to quickly make advanced, reliable OTDR measurements.
Its high dynamic range of up to 45 dB not only gives you the possi­bility to look at long stretches of fiber, but also helps you increase the speed at which you can accurately determine a certain event.
The HP E6000B, however, goes beyond a mini-OTDR. Its fiber break locator mode looks exclusively for breaks, and these are then dis­played quickly. The real-time mode gives you instant feedback on para­meter changes you make, so that the optimal setup can be found quickly.
Field Installation & Maintenance
Specifications
HP E6000B Dynamic Attenuation Mini-OTDR Wavelength Fiber Type Range Deadzone
HP E6001A 1310 ± 25 nm Single-mode 28 dB 10 m HP E6002A 1310 ± 25 nm Single-mode 35 dB 10 m HP E6003A 1310/1550 ± 25 nm Single-mode 35/34 dB 10/12 m HP E6003B 1310/1550 ± 25 nm Single-mode 40/38 dB 10/12 m HP E6004A 1310/1550 ± 25 nm Single-mode 28/28 dB 10/12 m HP E6008B 1310/1550 ± 25 nm Single-mode 45/43 dB 10/12 m HP E6010A 1625 ± 20 nm Single-mode 40 dB 14 m HP E6012A 1550/1625 ± 25/10 nm Single-mode 43/40 dB 12/14 m HP E6005A 850/1300 ± 30 nm Multimode 26/34 dB 10/10 m HP E6009A 850/1300 ± 30 nm Multimode 18/23 dB 10/10 m
Additional Modules
The HP E6000B mini-OTDR is not just a high performance OTDR for single-mode fiber networks. Additional modules and sub-modules en­hance its capabilities, without adding any significant weight. The mod­ules simply plug into the existing instrument, making the mini-OTDR the right tool for versatile, optical fiber test measurements.
Multimode Modules
These modules are designed to test all popular multimode fibers at both 850 nm and 1300 nm wavelengths. With an event deadzone of less than three meters, the HP E6005A multimode module offers a dynamic range of up to 34 dB.
Ultra High Performance 1625 nm Modules
The HP E6010B, HP E6012A, HP E4321A and HP E6060A OTDR mod­ules enable testing of Optical Supervisor y Channel capability of WDM links and fast and accurate fiber testing at 1625 nm. Out of band testing also allows users to perform a fiber test while transmitting data at 1310 nm or 1550 nm.
Optical Power Meter Sub-Module
This high performance, miniature and extremely light (130 g) sub­module provides a measurement range of +10 dBm to –70 dBm with 5% accuracy, 0.01 dB resolution and automatic zeroing. The power meter can be used to perform end-to-end loss testing, characterize optical passive components and test transmitter power levels.
A simple user interface and a hold data function make this power meter easy-to-use. A reference power level can be stored at each wave­length for loss measurements when the source is not available. It can even detect various modulation frequencies used to identify the wave­length being sent by the source. Now it’s possible to perfor m end-to-end loss testing without communicating with the other end of your link.
The power meter has high return loss and low polarization-depen­dent loss. This ensures accurate measurements, especially for high coherent laser sources, such as in Dense Wavelength Division Multiplex­ing (D-WDM) and CATV applications. It is fast, providing more than three updates each second. Its non-contact ferrule enhances reliability and facilitates cleaning in the field.
Visual Fault Finder Sub-Module
This visible light source helps you to identify bends, breaks and stress points along individual fibers at the patch panel. The bright red light allows you to locate these faults within the deadzone of an OTDR, and at distances of up to 5 km. The Visual Fault Finder can be used to identify fibers within a cable and also to check the quality of your patchcords and connections. The 1 Hz modulation causes the light to flash, making it easier to identify fibers and locate faults.
Optical Fiber Test Set–Everything in Your Hands
The mini-OTDR from Hewlett-Packard provides much more than just the fastest OTDR measurements; all the HP OTDR modules also act as pow­erful stabilized continuous wave (CW) light sources, and with the Optical Power Meter Sub-Module in place, you’re able to perfor m loss and power measurements. Within half a minute, you can switch from locating a break with the Visual Fault Finder to checking the multimode LAN.
All the OTDR modules use HP connector interfaces, which are easy to clean, interchangeable and provide flexibility.
At less than 2.8 kg (6.2 lbs), the HP E6000B, with its rugged design, is ideal to be carried even into those inaccessible places. Containing the most advanced smart battery technology, you never need be caught without power. The battery delivers exact information on the charge status—with an accurate on-screen “fuel gauge”. A full recharge takes less than 3 hours.
Optical Time Domain Reflectometer (cont’d)
There’s no need to switch instruments, for multimode or single­mode measurements; with the HP mini-OTDR, you have a complete optical fiber test set in one instrument.
Key Literature
Fiber Optic Test Solutions for Network Installation and Maintenance,
Color Brochure, p/n 5965-1256E HP E6000B Mini-Optical Time Domain Reflectometr, Technical
Specifications, p/n 5965-1298E
For more information, visit our web site:
http://www.hp.com/go/lightwave
Ordering Information
At least one user-exchangeable connector interface (HP 81000xI) is required for the module.
HP E6000B Mini-OTDR Mainframe
Opt 002 Hardcase
Opt 003 Color Display
Opt 004 Software Upgrade Kit
Opt 005 20 MB Flashdisk Card
Opt 006 B/W Display
Opt 007 Mini keyboard
Opt AB1 Korean user interface
Opt AB0 Traditional Chinese user interface
Opt AB2 Simplified Chinese user interface
Opt AB8 Turkish user interface
Opt AB9 Portuguese user interface
Opt ABD German user interface
Opt ABE Spanish user interface
Opt ABF French user interface
Opt ABJ Japanese user interface
Opt ACB Russian-Cyrillic user interface
Opt AKB Czech user interface HP E6001A 1310 nm single-mode module (30 dB)
Opt UK6 Calibration Report HP E6002A 1310 nm single-mode module (35 dB)
Opt UK6 Calibration Report HP E6003A 1310/1550 nm single-mode module (35/34 dB)
Opt UK6 Calibration Report
Opt 022 Angled Connector HP E6003B 1310/1550 nm single-mode module (40/38 dB)
Opt UK6 Calibration Report
Opt 022 Angled Connector HP E6004A 1310/1550 nm single-mode module (30/30 dB)
Opt UK6 Calibration Report
Opt 022 Angled Connector HP E6005A 850/1300 nm multimode module
(high performance) (26/34 dB)
Opt UK6 Calibration Report HP E6006A Optical Power Meter Sub-Module
Opt UK6 Calibration Report HP E6007A Visual Fault Finder Sub-Module HP E6008B 1310/1550 nm ultra high performance
single-mode module (45/43 dB)
Opt UK6 Calibration Report
Opt 022 Angled Connector HP E6009A 850/1300 nm multimode module
(economy) (18/23 dB)
Opt UK6 Calibration Report HP E6010A 1625 nm ultra high performance single- mode
module (40 dB) HP E6012A 1550/1625 nm ultra high performance single- mode (43/40 dB)
Opt UK6 Calibration Report
Opt 022 Angled Connector HP E6090A OTDR Toolkit Software HP 81000AI/FI/GI/HI/KI/SI/VI/WI Connector Interfaces
HP E597xA Handheld Fiber Optic Test Equipment
Please refer to Product Overview 5963-6656E.
395
HP 8147 HP E6000B
8
Internet URL www.hp.com/go/tmc00 Product & Order Info See page 607
Loading...