The following steps will guide you through configuring your E5061B.
Standard furnished item
DescriptionAdditional information
Installation guideContains the information necessary to start up with the E5061B.
CD ROM IO libraries
Power cable
Certifi cate of calibration
Note: Keyboard and mouse are not furnished as standard. Refer to “Step 5. Accessory option” for the selection of these
items.
Step 1. Choose test set option (mandatory)
DescriptionOption No.RequiresNot compatible Additional information
LF-RF network analyzer with
DC bias source, 5 Hz to 3 GHz
E5061B-3L5NoneNoneThis option has the following features.
- S-parameter test port (5 Hz to 3 GHz)
- Gain-phase test port (5 Hz to 30 MHz)
- Built-in DC bias source
Note: The E5061B-3L5 is the only one test set option as of Sep. 2009.
Step 2. Choose hardware option (If not required, go to step 3)
DescriptionOption No.RequiresNot compatible Additional information
High stability timebaseE5061B-1E5NoneNoneThis option improves the frequency accuracy
and stability of the E5061B.
Note: Refer to “Hardware upgrade” section for retrofit information on the above options.
Step 3. Choose hard disk drive option (mandatory)
DescriptionOption No.RequiresNot compatible Additional information
Standard hard disk driveE5061B-019NoneNone
Note: The E5061B-019 is the only one hard disk drive option. Removable hard disk drive is not provided for the E5061B.
Step 4. Choose software option (If not required, go to step 5)
DescriptionOption No.RequiresNot compatible Additional information
Time domain/fault location
analysis
E5061B-010NoneNoneAdds time domain and fault location analysis
function.
Note: Refer to “Software upgrade” section for retrofit information on the above options.
2
Step 5. Choose accessory option (If not required, go to step 6)
DescriptionOption No.RequiresNot compatible Additional information
Add keyboardE5061B-810NoneNoneAdds a keyboard.
Add mouseE5061B-820NoneNoneAdds a mouse.
Rack mount KitE5061B-1CMNoneE5061B-1CPAdds a rack mount kit.
Front Handle KitE5061B-1CNNoneE5061B-1CPAdds a front handle kit.
Rack mount and front
handle kit
E5061B-1CPNoneE5061B-1CM
E5061B-1CN
Adds a rack mount kit and a front handle kit.
Step 6. Choose calibration option
DescriptionOption No.Additional information
ISO 17025 compliant calibration E5061B-1A7Certifi cate of calibration compliant with ISO 17025 and test data is supplied.
ANSI Z540 compliant
calibration
E5061B-A6JCertifi cate of calibration compliant with ANSI Z540 and test data is supplied.
E5061B with mouse and keyboard
3
Test accessories and calibration kits
Test accessories and calibration kits that can be used with the E5061B are listed in this section. A complete line of test
accessories and calibration kits can be found at the Agilent RF and Microwave Test Accessories Web site:
www.agilent.com/find/accessories
Test accessories
Test accessories such as test port cable are necessary for a complete measurement system using the E5061B. Order test
accessories in accordance with the desired measurement system.
Calibration kits
Calibration is an accuracy enhancement procedure that effectively reduces the system errors that cause uncertainty in
network measurement. Calibration kit is necessary to perform the calibration.
• Mechanical calibration kits include standards, such as opens, shorts and loads, which are measured by the network
analyzer. Choose a calibration kit for each connector type to be used.
• Electronic calibration (ECal) modules1 replace mechanical calibration standards with one solid-state calibration module
that is controlled by the network analyzer via USB. ECal modules provide many different impedances to the test ports
which enables a full two-port calibration to be performed quickly with a single connection. This technique reduces
operator errors and connector wear and abrasion.
Mechanical calibration kits
1. ECal modules don’t cover the whole frequency range of the E5061B.
Check whether the frequency range of each ECal module meets your
measurement needs.
Electronic calibration (ECal) modules
4
Test accessories (for 50 Ω devices)
DescriptionModel No.RequiresAdditional information
Test Port Cable N6314ANone50 Ω type-N (m) to type-N (m) cable, DC to 12.4 GHz, 61 cm (24 in)
Test Port CableN6315ANone50 Ω type-N (m) to type-N (f) cable, DC to 12.4 GHz, 61 cm (24 in)
Test Port Cable11500ENone3.5 mm (m) to 3.5 mm (m) cable, 61 cm (24 in)
Test Port Cable11500FNone3.5 mm (m) to 3.5 mm (m) cable, 150 cm (24 in)
Test Port Cable11857DNone50 Ω 7 mm to 7 mm cable, 300 kHz to 6 GHz, 61 cm (24 in)
Test Port Cable8120-1838None50 Ω BNC (m) to BNC (m) cable, 30 cm (12 in)
Test Port Cable8120-1839None50 Ω BNC (m) to BNC (m) cable, 61 cm (24 in)
Adapter1250-0780None50 Ω type-N (m) to 50 Ω BNC (f) adapter
Adapter1250-1200None50 Ω BNC (f) to SMA (m) adapter
Adapter1250-2015None50 Ω BNC (m) to SMA (f) adapter
N6314A
11500F
11857D
N6315A
11500E
8120-1838
1250-1200
8120-1839
1250-0780
5
1250-2015
Test accessories (for 50 Ω devices, continued)
DescriptionModel No.RequiresAdditional information
None700 Hz to 26 GHz, 50 Ω SMA - SMA DC blocking capacitor.
The sexes of SMA connectors can be chosen as an option.
None100 kHz to 8 GHz, 50 Ω SMA (m) - SMA (f) DC blocking capacitor.
Aerofl ex / Weinschel 1507R
Pasternack Enterprises PE6008-50
North Hills Signal Processing 0017CC and Agilent E5061B
North Hills Signal Processing 0017CCPicosecond Pulse Labs 5508
Mini-Circuits BLK-89
Aeroflex / Weinschel web page: http://www.aeroflex.com/ams/weinschel/micro-weinschel-prods.cfm
North Hills Signal Processing web page: http://www.northhills-sp.com/index.html
Mini-Circuits web: http://www.minicircuits.com/index.html
Picosecond Pulse Labs web page: http://www.picosecond.com/
Pasternack Enterprises web page: http://www.pasternack.com/
9
Calibration kits (for 50 Ω devices)
DescriptionModel No.RequiresAdditional information
Economy calibration kit,
type-N, 50 Ω
Standard calibration kit,
type-N, 50 Ω
RF ECal module, Type-N,
50 Ω
Standard calibration kit, 3.5 mm 85033ENone50 Ω standard calibration kit, DC to 9 GHz. Includes;
85032ENone50 Ω economy calibration kit, DC to 6 GHz. Includes;
- Type-N (m) fi xed load
- Type-N (m) combined open/short
85032FNone50 Ω standard calibration kit, DC to 9 GHz. Includes;
- Type-N (m) fi xed load
- Type-N (f) fi xed load
- Type-N (m) Open
- Type-N (f) Open
- Type-N (m) Short
- Type-N (f) Short
85032F-100NoneAdds 50 Ω type-N (f) to type-N (f) adapter
85032F-200NoneAdds 50 Ω type-N (m) to type-N (m) adapter
85032F-300NoneAdds 50 Ω type-N (m) to type-N (f) adapter
85032F-500NoneAdds;
- 50 Ω type-N (m) to 7 mm adapter (2 qty.)
- 50 Ω type-N (f) to 7 mm adapter (2 qty.)
1
85092C
None2-port (50 Ω type-N), 300 kHz to 9 GHz. The sexes of the
connectors depend on the option.
85092C-M0F
85092C-00M
85092C-00F
2
NoneType-N (f) to Type-N (m) RF ECal module
2
NoneType-N (m) to Type-N (m) RF ECal module
2
NoneType-N (f) to Type-N (f) RF ECal module
85092C-00ANoneAdds;
- Type-N (f) to Type-N (f) adapter
- Type-N (m) to Type-N (m) adapter
3.5 mm (m) Load / 3.5 mm (m) Open / 3.5 mm (m) Short
- 3.5 mm (f) Load / 3.5 mm (f) Open / 3.5 mm (f) Short
- Torque wrench
85033E-100NoneAdds 3.5mm (f) to 3.5 mm (f) adapter
85033E-200NoneAdds 3.5mm (m) to 3.5 mm (m) adapter
85033E-300NoneAdds 3.5mm (f) to 3.5 mm (m) adapter
85033E-400NoneAdds;
- 3.5 mm (m) to 50 Ω type- N (m) adapter
- 3.5 mm (f) to 50 Ω type- N (f) adapter
- 3.5 mm (f) to 50 Ω type- N (m) adapter
- 3.5 mm (m) to 50 Ω type- N (f) adapter
85033E-500NoneAdds;
- 3.5 mm (m) to 7 mm adapter (2 qty.)
- 3.5 mm (f) to 7 mm adapter (2 qty.)
1. ECal doesn’t cover the whole frequency range of the E5061B.
Check whether the frequency range of the ECal module meets your
measurement needs.
2. Mixed connector options are also available. Visit our website for more
details about the ECal: www.agilent.com/find/ecal
10
Calibration kits (for 50 Ω devices, continued)
DescriptionModel No.RequiresAdditional information
RF ECal module, 3.5 mm 85093C
RF ECal module, selectable
connector type
Standard calibration kit,
7-16, 50 Ω
Standard calibration kit,
7-16, 50 Ω
Standard calibration kit,
7-16, 50 Ω
RF ECal module, 7-1685098C
Economy calibration kit,
7 mm, 50 Ω
1
None2-port (3.5 mm), 300 kHz to 9 GHz. The sexes of the connectors
depend on the option.
85093C-M0F
85093C-00M
85093C-00F
2
None3.5 mm (f) to 3.5 mm (m) RF ECal module
2
None3.5 mm (m) to 3.5 mm (m) RF ECal module
2
None3.5 mm (f) to 3.5 mm (f) RF ECal module
85093C-00ANoneAdds;
- 3.5 mm (f) to 3.5 mm (f) adapter
- 3.5 mm (m) to 3.5 mm (m) adapter
1
N4431B
None4-port, 9 kHz to 13.5 GHz. The connector type depends on the
option.
N4431B-010
N4431B-020
2
NoneFour 3.5 mm (f) connectors.
2
NoneFour 50 Ωtype-N (f) connectors
85038ANone50 Ω standard calibration kit, DC to 7.5 GHz. Includes;
- 7-16 (m) Load / 7-16 (m) Open / 7-16 (m) Short
- 7-16 (f) Load / 7-16 (f) Open / 7-16 (f) Short
- Torque wrench
- Open-end wrench
85038FNone50 Ω standard calibration kit, DC to 7.5 GHz. Includes;
- 7-16 (f) Load / 7-16 (f) Open / 7-16 (f) Short
- 7-16 (f) to 7-16 (f) adapter
85038MNone50 Ω standard calibration kit, DC to 7.5 GHz. Includes;
- 7-16 (m) Load / 7-16 (m) Open / 7-16 (m) Short
- 7-16 (m) to 7-16 (m) adapter
1
None2-port (7-16), 300 kHz to 7.5 GHz. The sexes of the connectors
depend on the option.
85098C-M0F
85098C-00F
85098C-00M
2
None7-16 (m) to 7-16 (f) RF ECal module
2
None7-16 (f) to 7-16 (f) RF ECal module
2
None7-16 (m) to 7-16 (m) RF ECal module
85098C-00ANoneAdds;
- 7-16 (m) to 7-16 (m) adapter
- 7-16 (f) to 7-16 (f) adapter
85031BNone50 Ω economy calibration kit, DC to 6 GHz. Includes;
- 7 mm Load (2 qty.)
- 7 mm combined Open/Short
1. ECal doesn’t cover the whole frequency range of the E5061B.
Check whether the frequency range of the ECal module meets your
measurement needs.
2. Mixed connector options are also available. Visit our website for more
details about the ECal: www.agilent.com/find/ecal
11
Test accessories (for 75 Ω devices)
DescriptionModel No.RequiresAdditional information
Test Port Cable11857BNone75 Ω type-N cable set, 61 cm (24 in), 300 kHz to 2 GHz. Includes;
- Type-N (m) to type-N (m) cable
- Type-N (m) to type-N (f) cable
Test Port Cable11857FNone75 Ω type-N to type-F cable set, 61 cm (24 in).
11857F-M0FNoneIncludes;
- Type-N (m) to type-F (m) cable
- Type-N (m) to type-F (f) cable
11857F-00FNoneIncludes;
- Type-N (m) to type-F (f) cable
11857F-00MNoneIncludes;
- Type-N (m) to type-F (m) cable
Minimum Loss Pad11852BNoneType-N minimum loss pad. DC to 3 GHz,
50 Ω type-N (f) to 75 Ω type-N (m)
11852B-004None50 Ω type-N (m) to 75 Ω type-N (f)
11857B
11852B
12
Calibration kits (for 75 Ω devices)
DescriptionModel No.RequiresAdditional information
Standard calibration kit, type-N,
75 Ω
Economy calibration kit,
type-N, 75 Ω
RF ECal module, Type-N, 75 Ω85096C
Economy calibration kit, type-F,
75 Ω
RF ECal module, Type-F85099C
85036BNone75 Ω standard calibration kit, DC to 3 GHz. Includes;
- Type-N (m) broadband load
- Type-N (f) broadband load
- Type-N (m) short
- Type-N (f) short
- Type-N (m) open
- Type-N (f) open body
- Type-N (f) open center conductor extender
- Type-N (m) to type-N (m) adapter
- Type-N (f) to type-N (f) adapter
- Type-N (m) to type-N (f) adapter
85036ENone75 Ω economy calibration kit, DC to 3 GHz. Includes;
- Type-N (m) broadband load
- Type-N (m) combined Open/Short
1
None2-port (75 Ω type-N), 300 kHz to 3 GHz. The sexes of the
connectors depend on the option.
85096C-M0FNoneType-N (m) to Type-N (f) RF ECal module
85096C-00FNoneType-N (f) to Type-N (f) RF ECal module
85096C-00MNoneType-N (m) to Type-N (m) RF ECal module
85096C-00ANoneAdds;
- Type-N (f) to Type-N (f) adapter
- Type-N (m) to Type-N (m) adapter
85039BNone75 Ω economy calibration kit, DC to 3 GHz.
85039B-M0FNoneIncludes;
- Type-F (m) Load / Type-F (m) Open / Type-F (m) Short
- Type-F (f) Load / Type-F (f) Open / Type-F (f) Short
- Type-F (m) to type-F (m) adapter
- Type-F (f) to type-F (f) adapter
- Type-F (f) to type-N (m) adapter
- Type-F (m) to type-N (f) adapter
85039B-00FNoneIncludes;
- Type-F (f) Load
- Type-F (f) Short
- Type-F (f) Open
- Type-F (f) to type-F (f) adapter
85039B-00MNoneIncludes;
- Type-F (m) Load
- Type-F (m) Short
- Type-F (m) Open
- Type-F (m) to type-F (m) adapter
1
None2-port (type-F), 300 kHz to 3 GHz. The sexes of the connectors
depend on the option.
85099C-M0FNoneType-F (m) to Type-F (f) RF ECal module
85099C-00FNoneType-F (f) to Type-F (f) RF ECal module
85099C-00MNoneType-F (m) to Type-F (m) RF ECal module
85099C-00ANoneAdds;
- Type-F (f) to Type-F (f) adapter
- Type-F (m) to Type-F (m) adapter
1. ECal doesn’t cover the whole frequency range of the E5061B.
Check whether the frequency range of the ECal module meets your
measurement needs.
13
General accessories
DescriptionModel/Part No.RequiresAdditional information
GPIB Cable, 1 m (3.3 ft)10833ANoneProvides a connection from a GPIB port to GPIB port.
GPIB Cable, 2 m (6.6 ft)10833BNone
GPIB Cable, 4 m (13.1 ft)10833CNone
GPIB Cable, 0.5 m (1.6 ft)10833DNone
GPIB Cable, 6 m (19.7 ft)10833FNone
GPIB Cable, 8 m (26.2 ft)10833GNone
GPIB to USB Interface82357BNoneProvides a direct connection from a USB port to GPIB port.
Rack Mount Kit5063-9216NoneRack mount kit for use without handles. Can be ordered as
option 1CM.
Front Handle Kit5063-9229NoneFront handle kit. Can be ordered as option 1CN.
Rack mount and front handle
kit
Rack mount rail kitE3663ACNoneRack mount rail kit for use with 5063-9216 or 5188-4430.
Transit case−−Transit case for the E5061B is not provided.
Testmobile Scope Cart1180CZNoneProvides convenient mobility of test equipment.
5188-4430NoneRack mont kit and front handle kit are included. Can be
ordered as option 1CP.
82357B1180CZ10833A
14
Instrument upgrade
The following options of the E5061B are available as an upgrade option. You can add these options to the existing E5061B
by ordering an upgrade kit.
Hardware upgrade (Installed by the Agilent service center)
Agilent E5061B Network Analyzer Data Sheet5990-4392EN
Web resources
Have access to the following website to acquire the latest news, product and support information, application literature
and more. http;//www.agilent.com/find/ena
15
www.agilent.com/find/emailupdates
Get the latest information on the
products and applications you select.
www.agilent.com/find/agilentdirect
Quickly choose and use your test
equipment solutions with confidence.
www.lxistandard.org
LXI is the LAN-based successor to
GPIB, providing faster, more efficient
connectivity. Agilent is a founding
member of the LXI consortium.
Removealldoubt
Our repair and calibration services
will get your equipment back to
you, performing like new, when
promised. You will get full value out
of your Agilent equipment throughout its lifetime. Your equipment
will be serviced by Agilent-trained
technicians using the latest factory
calibration procedures, automated
repair diagnostics and genuine parts.
You will always have the utmost
confidence in your measurements.
For information regarding self maintenance of this product, please
contact your Agilent office.
Agilent offers a wide range of additional
expert test and measurement services
for your equipment, including initial
start-up assistance, onsite education
and training, as well as design, system
integration, and project management.
For more information on repair and
calibration services, go to:
www.agilent.com/find/removealldoubt
www.agilent.com
For more information on Agilent
Technologies’ products, applications
or services, please contact your local
Agilent office. The complete list is
available at:
www.agilent.com/find/contactus
Americas
Canada (877) 894-4414
Latin America 305 269 7500
United States (800) 829-4444
Asia Pacific
Australia 1 800 629 485
China 800 810 0189
Hong Kong 800 938 693
India 1 800 112 929
Japan 0120 (421) 345
Korea 080 769 0800
Malaysia 1 800 888 848
Singapore 1 800 375 8100
Taiwan 0800 047 866
Thailand 1 800 226 008
Europe & Middle East
Austria 01 36027 71571
Belgium 32 (0) 2 404 93 40
Denmark 45 70 13 15 15
Finland 358 (0) 10 855 2100
France 0825 010 700*
*0.125 €/minute
Germany 07031 464 6333
Ireland 1890 924 204
Israel 972-3-9288-504/544
Italy 39 02 92 60 8484
Netherlands 31 (0) 20 547 2111
Spain 34 (91) 631 3300
Sweden 0200-88 22 55
Switzerland 0800 80 53 53
United Kingdom 44 (0) 118 9276201
Other European Countries:
www.agilent.com/find/contactus
Revised: July 2, 2009
Product specifications and descriptions
in this document subject to change
without notice.