Agilent E4403B Data Sheet

Page 1
product overview
When speed and accuracy count as much as your budget
Expanded to 3 and 26.5 GHz!
ESA-L Series
Spectrum Analyzers
Page 2
2
Speed, Accuracy, Affordability
Help key quickly communicates hardkey/softkey functions on screen.
Built-in tracking generator provides an RF source for scalar network analysis (optional).
Weather-resistant front panel allows operation in tough environments.
5ms sweep time and virtual real-time display update for easier circuit tuning.
High-resolution, high-contrast monochrome display makes viewing multiple traces easy.
Rugged package with rubber-encased frames resists transportation stresses.
Snap-on battery for portability (optional).
Automatic background alignment eliminates calibration worries.
Disk drive and parallel printer port provide PC compatibility and data archiving.
Page 3
3
Your budget is limited – your test equipment doesn’t have to be.
Now you can get the speed and accuracy you need and still have money left in your budget. HP ESA-L series of portable spectrum analyzers have a remarkable five-millisecond full-span RF sweep time and virtual real-time measurement updates to the display or through HP-IB interface. With excellent accuracy and easy, reliable operation, the HP ESA-L series is full of innovations, like a con­tinuously phase-locked synthesizer, all at a surprisingly low cost.
Frequency Frequency Phase Noise Residual FM Resolution Maximum Overall Maximum Measurement Range Accuracy (10 kHz offset) Bandwidth Amplitude Amplitude Dynamic to display 9 kHz to: (at 1 GHz) Range Range Accuracy Range (characteristic)
(2nd/3rdorder)
HP E4411B 1.5 Ghz ±2 kHz –90 dBc/Hz 150 Hz 1 kHz to –119 ±1.1 dB 77 dB/83 dB >28 updates/sec HP E4403B 3 GHz peak to peak 5 MHz –117 79 dB/83 dB HP E4408B 26.5 GHz –116 78 dB/82 dB
to +30 dBm
Specification summary
Designed for performance measurements
• Fast measurements
• Accurate results
• Rugged and reliable
• Quick and easy to use
HP E4411B
HP E4403B
HP E4408B
9 kHz 1.5 GHz 3 GHz 26.5 GHz
For complete specifications, see page 9. Ordering information is shown on page 12.
Available Frequency Ranges
Page 4
4
HP ESA-L series features and benefits
5-ms full-span RF sweep time Combined with 28 measurements per second, provides virtual real-time updates. Responsive
display makes circuit adjustment easier, while increasing the probability of intercepting
intermittent signals. High-speed data transfer (HP-IB) Fast processing reduces measurement time in ATE environments (optional). Fully synthesized design Provides continuously phase-locked precision throughout the entire sweep. Assures frequency
accuracy, stability, and measurement repeatability, eliminating drift. Fast time-domain sweeps Sweeps as fast as 2 microseconds per division in zero span (optional). Amplitude correction Calibrates out frequency-related amplitude effects with built-in amplitude correction. Automatic background alignment Continuously calibrates the analyzer. Guarantees repeatability over changing temperatures. 85-dB calibrated display range Allows simultaneous display of large and small signals. Built-in tracking generator Combines spectrum and scalar test capability in a single instrument (optional). Synthesized
design eliminates tracking drift (HP E4411B only). One-button normalize function quickly
the setup. 5-dB step attenuator Optimizes distortion-free dynamic range. Built-in frequency counter With 1-Hz resolution, minimizes the need for an external frequency counter.
Fast warm-up Provides full measurement accuracy after just five minutes. Snap-on battery Eliminates the restrictions of power cords. Rubber-encased front and rear frames Provides impact protection in the field. Rain-resistant front panel Combined with louvered air vents, allows operation in diverse weather conditions. 12-Vdc power cable Allows direct operation from automotive and truck batteries.
Large, monochrome VGA display 16.5 cm, high-resolution monochrome display with wide viewing angle makes detailed with output VGA observations easy. Includes 15-pin VGA rear output connector for external monitor.
Parallel port Supports output to the most popular printers (optional). Disk drive Makes saving and moving measurement results to your PC quick and easy. One-button measurements Save set-up and measurement time with adjacent channel power, occupied bandwidth, channel
power, peaks table, and harmonics table features. AM demodulation Combines with the built-in speaker for tune and listen applications. 100 trace and 32 instrument state files Provides internal storage of measurement data and setups for future analysis or comparison. Marker functions Provides digital resolution of measurement details through peak search, delta markers, marker
table and carrier-to-noise ratio. Signal track keeps unstable signals centered on the screen
while band power calculates total power between user-defined limits. Softkey/hardkey interface Provides a simple user interface while retaining access to sophisticated features. Built-in help button with function display Eliminates carrying manuals into the field to determine keypad and softkey functions. Limit lines Built-in-limit lines and pass/fail messages simplify testing. Built-in clock/calendar Provides storage of time stamps and printed data. Automatic overload protection Protects RF input from overly large signals (only available on the 1.5 GHz HP E4411B). Automatic printer setup Identifies connected HP printer models automatically.
Performance
1
Portability
Ease-of-use
1. For higher performance requirements, HP also offers the HP ESA-E series of spectrum analyzers. With its cardcage architecture, the HP ESA-E series is an investment in a flexible platform and a wider range of options, such as narrow-resolution bandwidth filters for viewing closely spaced signals and a built-in high-gain, low-noise preamplifier for better sensitivity measurements. For more information, order the HP ESA family literature shown on page 12.
The HP ESA-L series now comes with a standard THREE-YEAR warranty!
Page 5
5
Increase manufacturing throughput
Get real-time measurement feedback for circuit tuning and adjustment with up to 28 measurement updates per second and 5-millisecond full-span RF sweep time.
Speed up manual or automated testing with built-in limits lines and easy-to-interpret pass/fail messages.
The HP ESA-L series is SCPI-compliant (Standard Commands for Program­mable Instruments) and reduces test time by automating repetitive measurements using the HP-IB interface and VXIplug&play drivers.
With a combination of performance, speed and accuracy at an affordable price, the HP ESA-L series is ideal for manufacturing.
Eliminate measurement speed bottlenecks
Decrease training time
Save training time with the easy-to-use hardkey/softkey interface.
Reduce operator uncertainty with the easy-to-view, high-resolution digital display and numeric marker readouts.
View large and small signals simulta­neously on screen with 85-dB calibrated display range.
Enlarge the display by removing the softkey interface or connecting to an external VGA monitor.
Increase measurement confidence and reliability
With ±1.1 dB amplitude accuracy, the HP ESA-L series instruments are fully synthesized and phase locked over the entire sweep for frequency accuracy, stability and repeatability.
Automatic background alignment improves accuracy and offers continuous calibration to assure measurement accuracy.
The HP ESA-L series is manufactured in an ISO 9001-registered facility to HP’s exacting standards.
Page 6
6
Calibrated field measurements in just FIVE minutes!
Easy-to-use, portable performance. Snap-on rechargeable battery for up
to 1.9 hours of cordless operation (optional).
12-Vdc power cable for running the analyzer on a vehicle battery (optional).
Built-in tracking generator and frequency counter means less equipment to carry (optional).
Flexible tilt handle for optimum viewing angles on the bench or floor.
Easy data transfer to a computer with built-in floppy disk drive.
Take lab-grade performance into the field
Get fully synthesized performance in a rugged portable package for lasting accuracy in tough environments.
Continuous background alignment provides accuracy over varying temperatures.
Conforms to the environmental specifications of MIL-PRF-28800F class 3.
Built-in help eliminates need to carry manuals into the field.
Designed for field applications, the HP ESA-L series provides accurate performance in a wide variety of environments.
Easy, worry-free field measurements
Page 7
Research and Development Education
7
Provide students with fast and accurate spectrum analysis while conserving your budget.
Now you don’t have to buy a high-priced spectrum analyzer to get advanced technology on every engineer’s bench.
Verify your designs with confidence
The HP ESA-L series offers ±1.1 dB amplitude accuracy, ±1% span accuracy, ±2 kHz frequency accuracy, and a continuously phase-locked synthesizer for stability and repeatability.
Transfer measurement results directly to your computer with the help of the HP EEsof Advanced Design System instrument link/driver or HP BenchLink Spectrum Analyzer software.
Sophisticated performance at a budget price eliminates the need to share analyzers.
Save money and stay competitive
Equip your students with fast, accurate spectrum analyzers, at an affordable price.
Fully synthesized digital design provides accurate and repeatable measurements.
Rugged design, such as the input overload protection available on the
1.5 GHz HP E4411B, guards against damage to the analyzer.
Easy-to-understand interface simplifies operation and aids access to more sophisticated functions.
Page 8
8
HP ESA-L series – a whole product solution
The performance of the HP ESA-L series spectrum analyzer is only a small part of what you get from Hewlett Packard. HP strives to provide complete solutions that go beyond our customers’ expectations. Only HP offers the depth and breadth of enhancements, software, services, connectivity, accessibility and support to help our customers reach their measurements objectives. Please contact HP for more information.
For the latest information on the HP ESA-L series see our web page at:
www.hp.com/go/esa
Post-sales support
• Standard three-year global warranty
• Worldwide Call Center and Service Center support network
• One-year calibration intervals
• Firmware upgrades downloadable from the web
Software
• Programming examples on CD ROM
• SCPI (Standard Commands for Programmable Instruments)
• EMI PC software
Training and access to information
• Factory service training
• Web-based support of frequently asked questions
• Manuals on CD ROM and on the web
PC connectivity
• Floppy disk drive
• HP-IB or RS232 interfaces
• VXI plug&play drivers
• HP BenchLink spectrum analyzer software (32 bit)
• HP EEsof Advanced Design System driver (instrument link)
Product and peripheral interfaces
• HP 8590-series/ESA programming conversion guide
• Printer support
Pre-sales service
• Rentals, leasing, and financing
• Application engineering services
• Application notes
• Custom product modifications
• Custom downloadable programs
Page 9
9
Specifications
Frequency Specifications
Frequency Range
HP E4411B
50 9 kHz to 1.5 GHz
75(Opt. 1DP) 1 MHz to 1.5 GHz HP E4403B 9 kHz to 3.0 GHz HP E4408B 9 kHz to 26.5 GHz Band LO harmonic = N
0 1 9 kHz to 3.0 GHz
1 1 2.85 GHz to 6.7 GHz
2 2 6.2 GHz to 13.2 GHz
3 4 12.8 GHz to 19.2 GHz
4 4 18.7 GHz to 26.5 GHz
Frequency Reference
Aging Rate ±2x10-6/year,
±1.0x10-7/day,
characteristic
Settability ±5x10
-7
Temperature Stability ±5x10
-6
Frequency Readout Accuracy
(Start, Stop, Center, Marker) ±(frequency readout x frequency
reference error1+ span accuracy + 15% of RBW + 10 Hz)
Marker Frequency Counter
Accuracy ±(marker frequency x frequency
reference error1+ counter resolution)
Resolution Selectable from 1 Hz to 100 kHz
Frequency Span
Range 0 Hz (zero span), and HP E4411B 100 Hz to 1.5 GHz HP E4403B 100 Hz to 3.0 GHz HP E4408B 100 x N
2
Hz to 26.5 GHz
Resolution Four digits or 2 Hz,
whichever is greater
Accuracy ±1% of span
Sweep Time
Range 5 ms to 2000 sec. Accuracy ±1% Sweep Trigger Free run, Single, Line, Video,
Delayed Trigger, and External
Resolution Bandwidth
Range (–3 dB bandwidth) 1 kHz to 3 MHz in 1-3-10 sequence
and 5 MHz
(–6 dB bandwidth) 9 kHz and 120 kHz
Accuracy
1 kHz to 1 MHz RBW ±10%
9 kHz, 120 kHz, 3 MHz ±15%
5 MHz RBW ±30% Selectivity
60 dB/3 dB bandwidth ratio
<15:1, characteristic
Video Bandwidth Range
(–3 dB bandwidth) 30 Hz to 1 MHz in 1-3-10 sequence,
3 MHz, characteristic
Stability
Noise sidebands (1 kHz RBW, 30 Hz VBW and sample detector) HP E4411B
10 kHz offset from CW signal –90 dBc/Hz 20 kHz offset from CW signal –100 dBc/Hz30 kHz offset from CW signal –102 dBc/Hz 100 kHz offset from CW signal –112 dBc/Hz
HP E4413B, E4408B 10 kHz offset from CW signal –90 dBc/Hz + 20 Log N
2
20 kHz offset from CW signal –98 dBc/Hz + 20 Log N
2
30 kHz offset from CW signal –100 dBc/Hz + 20 Log N
2
100 kHz offset from CW signal –112 dBc/Hz + 20 Log N
2
Residual FM
1 kHz RBW, 1 kHz VBW 150 Hz peak-to-peak x N2 in100 ms
System-Related Sidebands
30 kHz offset from –65 dBc + 20 Log N
2
CW signal
Amplitude Specifications
Absolute Amplitude Accuracy
Overall Amplitude Accuracy3±(0.6 dB +absolute frequency response)
20 to 30°C
At reference settings
6
±0.4 dB
Measurement Range Displayed average noise level
to maximum safe input level
Input Attenuator Range
HP E4411B 0 to 60 dB, in 5 dB steps HP E4403B, E4408B 0 to 65 dB, in 5 dB steps
Maximum Safe Input Level
Average Continuous Power HP E4411B (15 dB attenuation) +30 dBm (1W) HP E4403B, E4408B
(5 dB attenuation) +30 dBm (1W) Peak Pulse Power HP E4411B (15 dB attenuation) +30 dBm (1W) HP E4403B, E4408B
(5 dB attenuation) +50 dBm (100W) 1-dB Gain Compression (total power at input mixer)
4, 5
HP E4411B 0 dBm HP E4403B 0 dBm HP E4408B
50 MHz to 6.7 GHz 0 dBm
6.7 GHz to 13.2 GHz –3 dBm
13.2 GHz to 26.5 GHz –5 dBm
Displayed Average Noise Level
(Input terminated, 0 dB attenuation, sample detector, reference level = –70 dBm, 1 kHz RBW, 30 Hz VBW) HP E4411B
400 kHz to 1 MHz –117 dBm
1 MHz to 500 MHz –119 dBm
500 MHz to 1.0 GHz –117 dBm
1.0 GHz to 1.5 GHz –113 dBm
HP E4411B (Option 1DP)
1 MHz to 500 MHz –65 dBmV
500 MHz to 1.0 GHz –60 dBmV
1.0 GHz to 1.5 GHz –53 dBmV
All specifications apply over 0°C to +55°C. The analyzer will meet its specifications five minutes after it is turned on, when the analyzer is within one year of calibration cycle, after two hours of storage within the operating temperature range, and Auto Align All is selected. ITALICS = supplemental information, characteristics, typical performance, or nominal values.
1
Frequency reference error = (aging rate x period of time since adjustment + settability + temperature stability).
2
N = Harmonic mixing mode. N = 1 for E4411B and E4403B.
3
For reference level 0 to –50 dBm: input attenuation, 10 dB; 50 MHz; RBW, 3 kHz, VBW, 3 kHz; log range 0 to 50 dB;
sweep time coupled, signal input, 0 to –50 dBm; span, –60 kHz.
4
Mixer Power Level (dBm) = Input Power (dBm) – Input Attenuator. (dB).
5
For RBW 30 kHz, maximum input signal amplitude must be reference level + 10 dB.
6
Settings are: reference level –25 dBm for E4411B, –20 dBm for E4403B and E4408B; input attenuation 10 dB; center frequency
50 MHz; resolution bandwidth 3 kHz; video bandwidth 3 kHz; span 2 kHz; sweep time coupled; signal at reference level.
Page 10
10
Specifications, continued
HP E4403B
10 MHz to 1.0 GHz –117 dBm
1.0 GHz to 2.0 GHz –116 dBm
2.0 GHz to 3.0 GHz –114 dBm
HP E4408B
10 MHz to 1.0 GHz –116 dBm
1.0 GHz to 2.0 GHz –115 dBm
2.0 GHz to 6.0 GHz –112 dBm
6.0 GHz to 12.0 GHz –110 dBm
12.0 GHz to 22.0 GHz –107 dBm
22.0 GHz to 26.5 GHz –101 dBm
Spurious Responses
Second Harmonic Distortion HP E4411B
2 MHz to 750 MHz <–75 dBc for –40 dBm signal at
input mixer
1
HP E4403B, E4408B
10 MHz to 500 MHz <–60 dBc for –30 dBm signal at
input mixer
1
500 MHz to 1.5 GHz <–70 dBc for –30 dBm signal at
input mixer
1
1.5 GHz to 2.0 GHz <–80 dBc for –10 dBm signal at input mixer
1
2.0 GHz to 13.25 GHz <–95 dBc for –10 dBm signal at input mixer
1
Maximum Achievable Second Order Dynamic Range
HP E4411B (at 500 MHz) 77 dB HP E4403B (at 1 GHz) 79 dB
HP E4408B (at 1 GHz) 78 dB Third Order Intermodulation Distortion HP E4411B
10 MHz to 1.5 GHz <–75 dBc for two –30 dBm signals
at input mixer1, >50 kHz separation
HP E4403B, E4408B
100 MHz to 6.7 GHz <–75 dBc for two –30 dBm signals
at input mixer1, >50 kHz separation
6.7 GHz to 26.5 GHz <–70 dBc for two –30 dBm signals at input mixer1, >50 kHz separation
Maximum Achievable Third Order Dynamic Range
HP E4411B (at 1.0 GHz) 83 dB HP E4403B (at 1.0 GHz) 83 dB
HP E4408B (at 1.0 GHz) 82 dB Other Input-Related Spurious HP E4411B <–65 dBc, 30 kHz ≤offset ≤1.2 GHz,
for –20 dBm signal at input mixer
1
HP E4403B, E4408B <–65 dBc, >30 kHz offset, for –20 dBm
signal at input mixer
1
Residual Responses
Input terminated and 0 dB attenuation <–90 dBm
Display Range
Log Scale 0 to –85 dB from reference level is
calibrated; 0.1, 0.2, 0.5 dB/division and 1 to 20 dB/division in 1 dB steps;
ten divisions displayed. Linear Scale 10 divisions Scale units dBm, dBmV, dBµV, V, and W
Marker Readout Resolution
Log Scale 0.04 dB Linear Scale 0.01% of reference level
Reference Level
Range adjustable over amplitude
measurement range Resolution
Log Scale ±0.1 dB Linear Scale ±0.12% of reference level
Accuracy (at fixed frequency, a fixed attenuation, and reference to
–30 dBm + attenuation setting) Reference Level – Input Attenuation –10 dBm to –60 dBm ±0.3 dB –60 dBm to –85 dBm ±0.5 dB –85 dBm to –90 dBm ±0.7 dB
Frequency Response (10 dB attenuation, 20°C to 30°C)
Absolute2Relative
3
9 kHz to 3.0 GHz ±0.5 dB ±0.5 dB
3.0 GHz to 6.7 GHz ±1.5 dB ±1.0 dB
6.7 GHz to 13.2 GHz ±2.0 dB ±1.7 dB
13.2 GHz to 25 GHz ±2.5 dB ±2.0 dB 25 GHz to 26.5 GHz ±3.0 dB ±2.0 dB
Resolution Bandwidth Switching Uncertainty
(Referenced to 3 kHz RBW, at reference level) 1 kHz, 10 kHz to 3 MHz RBW ±0.3 dB 5 MHz RBW ±0.6 dB
Linear to Log Switching ±0.15 dB at reference level Display Scale Fidelity
Log Maximum Cumulative
0 to –85 dB from ±(0.3 dB + 0.01 x dB from reference level reference level)
Log Incremental Accuracy
reference level ±0.4 dB/4 dB
Linear Accuracy ±2% of reference level
General Specifications
Measurement Speed
Local measurement and
display update rate
4
28 per second, characteristic
Remote measurement and
HP-IB transfer rate
4,5
19 per second, characteristic
Temperature Range
Operating 0°C to +55°C Storage –40°C to +75°C Disk drive 10°C to 40°C
EMI Compatibility Conducted and radiated emission is in
compliance with CISPR Pub. 11/1990
Group 1 Class A
1
Mixer Power Level (dBm) = Input Power (dBm) – Input Attenuator. (dB).
2
Referenced to amplitude at 50 MHz.
3
Referenced to midpoint between highest and lowest frequency response deviations.
4
Autoalign Off, 5 ms sweep time, fixed center frequency.
5
Display Off, 401-point trace, and integer 32-bit data format, requires Option A4H.
Second Harmonic Distortion 10 MHz to 500 MHz Second Harmonic Distortion 500 MHz to 1.5 GHz Third Order Distortion 100 MHz to 3 GHz
DANL 10 MHz to 1 GHz
DANL 1 GHz to 2 GHz
DANL 2 GHz to 3 GHz
–70 –60 –50 –40 –30 –20 –10 0
Mixer Level (dBm)
–40
–50
–60
–70
–80
–90
DANL and distortion products relative to mixer level (dBm)
HP E4403B
Page 11
11
Audible Noise (ISO 7779) Sound Pressure at 25°C <40 dB, (<5.3 Bels power)
Power Requirements
ac Voltage 90 to 132 Vrms, 195 to 250 Vrms
Frequency 47 to 440 Hz, 47 to 66 Hz Power Consumption, On <300W Power Consumption, Standby <5W
dc Voltage 12 to 20 Vdc
Power Consumption <200W
Weight (without options) HP E4411B
12.6 kg (27.7 lb), characteristic
HP E4403B
14.9 kg (32.9 lb), characteristic
HP E4408B
16.2 kg (35.6 lb), characteristic
Dimensions
Height 222 mm (8.75 in) Width 373 mm (14.7 in) without handle
408 mm (16.1 in) with handle
Depth 409 mm (16.1 in) without handle
516 mm (20.3 in) with handle
Data Storage
Internal
200 traces or 50 states, nominal
Inputs/Outputs
Amplitude Reference
1
Internal HP E4411B
–25 dBm, nominal
HP E4411B, Option 1DP
+28.75 dBmV, nominal
External, BNC (f)
HP E4403B, E4408B
–20 dBm, nominal
Front Panel Connectors
Input Type N (f), 50Ω
nominal
Option 1DP (HP E4411B) BNC (f), 75Ω
nominal
Option BAB (HP E4408B) APC 3.5 (m)
RF Out
Option 1DN Type N (f), 50Ω
nominal
Option 1DQ (HP E4411B) BNC (f), 75Ω
nominal
Probe Power, Voltage/Current
+15 Vdc, –12.6 Vdc at 150 mA maximum
Speaker
Front-panel knob controls volume
Headphone 3.5 mm (1/8 in) miniature audio jack
Rear Panel Connectors
10 MHz Ref Output BNC (f), 50Ω
, >0 dBm, characteristic
10 MHz Ref Input BNC (f), 50Ω
, –15 to +10 dBm,
characteristic
External Trigger Input BNC (f),
(5V TTL)
VGA Output VGA compatible, 15-pin mini D-SUB,
640 x 480 resolution
IF Sweep and Video Ports (Option A4J) Aux IF Output BNC (f),
21.4 MHz, nominal –10 to
–70 dBm (uncorrected), characteristic
Aux Video Out BNC (f),
0 to 1 V (uncorrected),
characteristic
Hi Swp In BNC (f),
(5 V TTL)
Hi Swp Out BNC (f),
(5 V TTL)
Swp Out BNC (f),
0 to +10 V ramp, characteristic
HP-IB Interface
Option A4H IEEE-488 bus connector
Serial Interface
Option 1AX 9-pin D-SUB (m),
RS-232
Parallel Interface
Option A4H or 1AX 25-pin D-SUB (f),
printer port only
Tracking Generator (Option 1DN and Option 1DQ)
Output Frequency Range
HP E4411B 50(Opt. 1DN) 9 kHz to 1.5 GHz HP E4411B 75(Opt. 1DQ) 1 MHz to 1.5 GHz HP E4403B, E4408B (Opt. 1DN) 9 kHz to 3.0 GHz
Output Power Level
2
Range HP E4411B 50 0 to –70 dBm HP E4411B 75 +42.76 to –27.24 dBmV HP E4403B, E4408B 50 –1 to –66 dBm Vermier
HP E4411B
Range 10 dB Output Attenuator Range 0 to 60 dB, 10 dB steps
HP E4403B, E4408B
Range 9 dB Output Attenuator Range 0 to 56 dB, 8 dB steps
Output Power Sweep
2
Range HP E4411B 50 –15 dBm to 0 dBm –
(source attenuator setting) HP E4411B 75 +27.76 dBmV to +42.76 dBmV –
(source attenuator setting) HP E4403B, E4408B 50 –10 dBm to –1 dBm –
(source attenuator setting)
Output Flatness
HP E4411B 50(referenced to 50 MHz, 0 dB attenuation)
10 MHz to 1.5 GHz ±1.5 dB
HP E4411B 75(referenced to 50 MHz, 0 dB attenuation)
10 MHz to 1.5 GHz ±2 dB
HP E4403B, E4408B 50(referenced to 50 MHz, –20 dB signal level)
10 MHz to 3.0 GHz ±2 dB
Spurious Output
Harmonic Spurs HP E4411B, 50(0 dBm output), 75( +42.8 dBmV output)
20 MHz to 1.5 GHz <–25 dBc
HP E4403B, E4408B 50(–1 dBm output)
9 MHz to 3 GHz <–25 dBc
Dynamic Range Maximum output power level–
displayed average noise level
Output Tracking
HP E4411B
Drift No error Swept Tracking Error No error for coupled sweep times
HP E4403B, E4408B
Drift
1.5 kHz/5 minute, characteristic
Swept Tracking Error
Usable in 1 kHz RBW after 5 minutes
or warm up
Output VSWR
HP E4411B
<2.5:1, characteristic
HP E4403B, E4408B
0 dB attenuation
<2.0:1, characteristic
>8dB attenuation
<1.5:1, characteristic
Specifications, continued
1
Amplitude reference actual power might differ from the nominal value. Actual calibration power is stored internally.
2
E4411B: 20°C to 30°C.
Page 12
Data Subject to Change Copyright © 1999 Hewlett-Packard Company Printed in U.S.A. 3/99 5965-6309E
HP E4411B RF Spectrum Analyzer
9 kHz to 1.5 GHz
HP E4403B RF Spectrum Analyzer
9 kHz to 3.0 GHz
HP E4408B Microwave Spectrum Analyzer
9 kHz to 26.5 GHz
Options
A4H HP-IB and parallel (Centronics) interfaces
(not compatible with Option 1AX)
1AX RS-232 and parallel (Centronics) interfaces
(not compatible with Option A4H)
A4J IF, sweep, and video ports (not compatible
with Option AYX)
1DN 50-Ohm tracking generator
(9 kHz to 1.5 GHz for HP E4411B) (9 kHz to 3.0 GHz for HP E4403B and HP E4408B)
1DP 75-Ohm input impedance
(1 MHz to 1.5 GHz) HP E4411B only
1DQ 75-Ohm tracking generator
(1 MHz to 1.5 GHz) (requires Option 1DP)
1D7 50 to 75-Ohm matching pad
(type n (m) to BNC (f))
A5D 12-Vdc power cable0B0 Deletes manualsAYT Soft operating/carrying case (grey)AYU Soft operating/carrying case (yellow)AXT Hard transit caseUK9 Front-panel protective cover1CP Rack-mount kit with handles and slides0B1 Additional user and calibration guides0BW Assembly-level service guide UK6 Commercial calibration certificate with data8ZE Refurbished spectrum analyzer (as available)W32 Three-year calibrationW50/52 Additional two-year service and support/
five-year calibration
Accessories
HP C2950A Parallel printer cable (2 meter)HP 10833A HP-IB cable (1 meter)HP 24542U RS-232 cable (3 meter, 9 pin
F to 9 pin F) (for serial 9 pin PC connection to analyzer)
HP 24542G RS-232 cable (3 meter, 25 pin M
to 9 pin F) (for serial 25 pin PC or printer connection to analyzer)
HP 24542M RS-232 cable (3 meter, 25 pin M
to 9 pin F) (for serial 25 pin modem connection to analyzer)
HP 87405A Preamplifier (10 MHz to 3 GHz,
24 dB gain) (fastened to RF input, powered from analyzer)
HP 85905A 75 Ohm preamplifier (45 MHz to
1 GHz, 20 dB gain) (powered from analyzer)
HP 41800A Active probe (5 Hz to 500 MHz)HP 85024A High frequency active probe
(300 kHz to 3 GHz)
HP E1779A Battery packHP E4444A BenchLink Spectrum Analyzer
software (PC image and data transfer)
VXIplug&play instrument drivers available via the
worldwide web at: http://www.hp.com/go/inst_drivers (Click on VXIplug&play universal instrument drivers.)
Literature
HP ESA Self-Guided Demo 5968-3658ESpectrum Analysis Basics, AN 150 5952-0292HP ESA-E series
spectrum analyzer brochure 5968-3278E
HP ESA-E series specifications 5968-3386EHP 8560 E-series
spectrum analyzer brochure 5966-3559E
HP E4444A BenchLink
spectrum analyzer product overview 5966-0676E
HP E1779A rechargable battery pack 5966-1851E
For more information about Hewlett-Packard test and measure­ment products, applications, services, and for a current sales office listing, visit our web site, http://www.hp.com/go/tmdir.
Ordering information
Loading...