Agilent E4351B Data Sheet

The Agilent one-box Solar Array Simulator (SAS) is a dc power source that simulates the output characteristics of a solar array. The SAS is primarily a current source with very low output capacitance and is capable of simulating the I-V curve of different arrays under dif­ferent conditions (i.e., temperature, age etc.). The I-V curve is program­mable over the IEEE-488.2 bus and is conveniently generated within the SAS. The SAS provides three current operating modes:
1. Simulator Mode: An internal algo­rithm is used to approximate a SAS I-V curve. Four input parame­ters: Voc (open circuit voltage), Isc (short circuit current), Imp and Vmp (current and voltage at the peak power point on the curve) are needed to establish a curve in this mode.
2. Table Mode: For a fast and accurate I-V simulation, the SAS provides a table mode. The I-V curve is set by a user-defined table of points. A table can have any length up to 4000 points (a point corresponds to a specific value of I and V). As many as 30 tables may be stored in each of the SAS built-in volatile and non-volatile memory.
Agilent Application Specific dc Power Supplies tailored solutions for specific needs
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
69
Fast and accurate simulation of any type of solar array Multiple simulation modes Fast recovery time Easy to simulate environmental conditions
Solar Array Simulators
Specifications
(at 0˚to 55˚C unless otherwise specified)
E4350B E4351B E4350B- E4350B-
J01 J02
Special Order Special Order Option Option
Number of outputs 111 1 GPIB Yes Yes Yes Yes Output ratings
(Simulator and Table Modes) Max. Power 480 W 480 W 480 W 480 W Voc. Max. 65 V 130 V 54 V 86.6 V Isc. Max. 8 A 4A 9.6 A 6 A Output ratings (for mixed mode) Max Power 480 W 480 W 480 W 480 W V rated 0-60 V 0-120 V 0-50 V 0-80 V I rated 0-8 A 0-4 A 0-9.6 A 0-6 A
Programming accuracy
at 25˚C ±5˚C Voltage (Fixed Mode) 0.075% + 10 mV 0.075% + 20 mV 0.075% + 8.5 mV 0.075% + 13.5 mV Current (Simulator and Fixed Mode) 0.2% + 20 mA 0.2% + 10 mA 0.2% + 25 mA 0.2% + 15 mA
Ripple and noise
from 20 Hz to 20 MHz Voltage rms 16 mV 24 mV 16 mV 21 mV Voltage p-p 125 mV 195 mV 125 mV 175 mV Current rms 4 mA 4 mA 4 mA 4 mA
I
ac
I
mp
P
max
I
V
V
mp Voo
I
rated
P
max
I
V
V
rated
E4350B, E4351B
Simulator Mode Fixed Mode
70
Supplemental Characteristics for all model numbers
Load Switching Recovery Time: < 5 µs when
switched from short circuit to variable load, to within 1.5 A of an operating point on the I-V curve.
Remote Sensing: Up to 2 V+ (Voc-Vmp). Add 3 mV to the voltage load regulation specification for each 1 volt change in the positive output lead due to load current change.
Analog Programming of Output Current
Input Signal: 0 to -4.0 V Input Impedance: 20 k Ohms nominal
Shunt Regulation: Switching frequency
up to 50 kHz
Solar Array Simulators (Continued)
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
Agilent Application Specific dc Power Supplies tailored solutions for specific needs
Non-volatile memory can store a maximum of 3500 points. The tables (I-V curves) are easily stored and recalled with an IEEE-488.2 com­mand. The table(s) stored in this memory will be retained when the power is turned off. Volatile memo­ry greatly increases the flexibility by saving up to 30,000 points. Multiple tables are easily accessed with IEEE-488.2 command. These tables will be erased after power is removed.
In Table Mode, current and voltage offsets can be applied to the select­ed table to simulate a change in the operating conditions of the solar array.
3. Fixed Mode: This is the default mode when the unit is powered on. The unit has the rectangular I-V characteristics of a standard power supply, when an output capacitor is added in this mode.
Specifications
(at 0˚to 55˚C unless otherwise specified)
E4350B- E4350B- E4350B­J03 J04 J06
Special Order Special Order Special Order Option Option Option
Number of outputs 111 GPIB Yes Yes Yes Output ratings
(Simulator and Table Modes) Max. Power 480 W 480 W 480 W Voc. Max. 52 V 47 V 74 V Isc. Max. 10 A 11 A 7 A Output ratings (for mixed mode) Max Power 480 W 480 W 480 W V rated 0 - 48 V 0 - 43.5 V 0 - 68 V I rated 0.10 A 0 - 10 A 0 - 7 A Programming accuracy at 25˚C ±5˚C Voltage (Fixed Mode) 0.075% + 8 mV 0.075% + 8 mV 0.075% + 11.5 mV Current (Simulator and Fixed Mode) 0.2% + 27.5 mA 0.2% + 30.5 mA 0.2% + 17.5 mA
Ripple and noise
from 20 Hz to 20 MHz Voltage rms 16 mV 16 mV 19 mV Voltage p-p 125 mV 125 mV 150 mV Current rms 5.5 mA 6.5 mA 4 mA
Series Regulation: Switching frequency up to 50 kHz
OVP and OCP: Overvoltage and overcur­rent protection triggers in 100 us
Capacitive Load: In fixed mode, the maxi­mum load capacitance (without causing instability) is 2000 uF. In simulator and table mode, it is unconditionally stable at all capacitive loads.
Inductive Load: The maximum load inductance (without causing instability) is 200 µH
Regulatory Compliance: Listed to UL3101, certified to CSA 22.2 No. 1010.1, complies with EN 61010-1.
RFI Suppression: Complies with CISPR-11, Group 1, Class A
Size: 425.5 mm W x 132.6 mm H x
497.8 mm D (16.75 in x 5.25 in x 19.6 in) See page 102 for more details.
Weight: Net, 25 kg (54 lb); shipping, 28 kg (61 lb)
Warranty: Three years
Ordering Information
Opt 100 87 to 106 Vac, 47 to 63 Hz Opt 120 104 to 127 Vac, 47 to 63 Hz Opt 220 191 to 233 Vac, 47 to 63 Hz
Opt 240 209 to 250 Vac, 47 to 63 Hz * Opt 908 Rackmount Kit, p/n 5062-3977 * Opt 909 Rackmount Kit with Handles,
p/n 5063-9221
Opt 0L2 Extra Standard
Documentation Package
Opt 0B3 Service Manual
Opt 0B0 No documentation package * Support rails required
Accessories p/n 1252-3698 7-pin Analog Plug p/n 1252-1488 4-pin Digital Plug p/n 5080-2148 Serial Link Cable
2 m (6.6 ft)
p/n 1494-0059 Accessory Slide Kit