Data Sheet
PDFINFO H 5 6 1 1 - 0 1
Six 1x4, 50 Ω RF Multiplexer
Agilent E1472A
• 1-Slot, C-size, register based
• Six 1x4 multiplexers
• Switch signals up to 1.3 GHz
• SMB male connectors for high performance
• Controls E1473A/E1475A RF expanders
• Tree-switching for high isolation, low VSWR
Agilent E1472A
Description
The Agilent E1472A 50 Ω RF Multiplexer is a C-size, 1-slot,
register-based VXI module. It is the ideal choice to route
test signals from your application to your test instruments
(i.e., oscilloscope and spectrum, network, distortion
analyzers, or other RF equipment). The E1472A is functionally
identical to the E1474A except for output impedance.
The RF multiplexer can be used as six multiplexers or
combined with others to form a larger tree-switched
multiplexer or a limited stubless matrix. You can easily and
inexpensively expand the E1472A via the E1473A 50Ω RF
multiplexer expander or via the E1475A 75Ω RF multiplexer
expander.
The E1472A can easily be programmed with SCPI commands
to scan multiple channels, where each channel is switched to
its common, one at a time. This module is arranged as six
independent banks of channels (Bank 0 through Bank 5),
each acting as a 1x4 one-wire multiplexer. Only one channel
in each bank can be connected to its common at any time.
The multiplexer relays are arranged in a tree-switched
configuration, providing high isolation and low VSWR. Each
channel consists of a nonlatching armature relay.
Refer to the Agilent Technologies Website for instrument
driver availability and downloading instructions, as well as for
recent product updates, if applicable.
Agilent Technologies

PDFINFO H 5 6 1 1 - 0 2
2
Cables and Connectors
Various 50 Ω cables are available from Agilent for connecting
to the SMB connectors on the front panel of the multiplexer.
Adapters and other connectors are also available. Connectors
are also available from Johnson Components.
Johnson Components:
U.S.A. Tel.: 1-800-247-8256
Outside U.S.A. Tel.: (507) 835-6222
Fax.: (507) 835-8356
Product Specifications
Input
Maximum voltage (center
or shield-to-center, shield
or chassis): 42 V
Maximum current (per channel or common):
DC: 1 A
AC rms: 1 A
Maximum power (per channel or common):
DC: 24 W
AC: 24 VA
DC
Maximum thermal offset: 6 µV
Closed channel resistance
(typical): <1 Ω initial
Insulation resistance
(between any two
terminals): >10E8 Ω≤40 °C, ≤65% RH
AC
Note: For AC performance, ZL=ZS=ZO, ≤40 °C, RH ≤95% for C-size, RH
≤65% for B-size
Characteristic impedance
(Zo):
50 Ω
Insertion loss:
<10 MHz: <0.1 dB
<100 MHz: <0.4 dB
<500 MHz: <0.9 dB
<1.3 GHz: <1.5 dB
<3 GHz (typ): <8.0 dB
Crosstalk (channel-to-channel):
<10 MHz: <–90 dB
<100 MHz: <–80 dB
Crosstalk (channel-to-channel, one channel closed or channel-tocommon) (terminated):
<200 MHz: n/a
<500 MHz: <–62 dB
<1.3 GHz: <–50 dB
<3 GHz (typ): n/a
VSWR:
<10 MHz: <1.05
<100 MHz: <1.15
<200 MHz: n/a
<500 MHz: <1.35
<1.3 GHz: <1.5
<3 GHz: n/a
Risetime: <300 ps
Signal delay: <3 ns
Capacitance:
Center-shield: n/a
Chassis-shield: n/a
General Characteristics
Relays: Non-latching armature
Power up/down state: All open
Minimum relay life:
No load: 5x10E6 operations
Rated load: 10E5 operations
General Specifications
VXI Characteristics
VXI device type: Register based, A16, slave only
Size: C
Slots: 1
Connectors: P1/2
Shared memory: None
VXI busses: None
C-size compatibility: n/a
Configuration
Each channel consists of a non-latching armature relay. At
power-on or reset, channels 00, 10, ... 50 are connected to
COM 00, 10, ... 50, respectively, and all other channels are
open (unterminated).
The RF multiplexer can be used as six multiplexers or
combined with others to form a larger tree-switched
multiplexer or a limited stubless matrix as shown in the
accompanying diagram.
To expand the E1472A refer to the E1473A 50Ω RF
multiplexer expander or the E1475A 75Ω RF multiplexer
expander. The E1472A can control other external relays
requiring 5V, 12V, or 24V drive.

PDFINFO H 5 6 1 1 - 0 3
3
Instrument Drivers
See the Agilent Technologies Website (http://www.agilent.com/find/
inst_drivers) for driver availability and downloading.
Command module
firmware: Downloadable
Command module
firmware rev: A.02
I-SCPI Win 3.1: Yes
I-SCPI Series 700: Yes
C-SCPI LynxOS: Yes
C-SCPI Series 700: Yes
Panel Drivers: Yes
VXI
plug&play
Win
Framework: Yes
VXI
plug&play
Win95/NT
Framework: Yes
VXI
plug&play
HP-UX
Framework: No
Module Current
I
PM
I
DM
+5 V: 0.1 0.1
+12 V: 0.36 0.01
–12 V: 00
+24 V: 00
–24 V: 00
–5.2 V: 00
–2 V: 00
Cooling/Slot
Watts/slot: 6.00
∆P mm H
2
O: 0.10
Air Flow liter/s: 0.50
Ordering Information
Description Product No.
Six 1x4 50 Ω RF Multiplexer E1472A
Service Manual E1472A 0B3
Agilent E1472A front panel detail

Agilent Technologies’ Test and Measurement Support, Services,
and Assistance
Agilent Technologies aims to maximize the value you receive, while minimizing
your risk and problems. We strive to ensure that you get the test and
measurement capabilities you paid for and obtain the support you need.
Our extensive support resources and services can help you choose the right
Agilent products for your applications and apply them successfully. Every
instrument and system we sell has a global warranty. Two concepts underlie
Agilent's overall support policy: "Our Promise" and "Your Advantage."
Our Promise
Our Promise means your Agilent test and measurement equipment will meet
its advertised performance and functionality. When you are choosing new
equipment, we will help you with product information, including realistic
performance specifications and practical recommendations from experienced
test engineers. When you receive your new Agilent equipment, we can help
verify that it works properly, and help with initial product operation.
Your Advantage
Your Advantage means that Agilent offers a wide range of additional expert test
and measurement services, which you can purchase according to your unique
technical and business needs. Solve problems efficiently and gain a competitive
edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty
repairs, and onsite education and training, as well as design, system
integration, project management, and other professional engineering services.
Experienced Agilent engineers and technicians worldwide can help you
maximize your productivity, optimize the return on investment of your Agilent
instruments and systems, and obtain dependable measurement accuracy for
the life of those products.
www.agilent.com/find/emailupdates
Get the latest information on the products and applications you select.
Agilent T&M Software and Connectivity
Agilent's Test and Measurement software and connectivity products, solutions
and developer network allows you to take time out of connecting your
instruments to your computer with tools based on PC standards, so you can
focus on your tasks, not on your connections.
www.agilent.com/find/connectivity for more information.
Visit
For more assistance with all your test and measurement needs or to find your local
Agilent office go to www.agilent.com/find/assist
Product specifications and descriptions in this document
subject to change without notice.
© Agilent Technologies, Inc. 2005
Printed in the USA May 1, 2005
5965-5611E