Agilent E1412A Data Sheet

Data Sheet
6.5-Digit High-Accuracy Multimeter, C-Size
Agilent E1412A
1-Slot, C-size, message based
DCV, ACV, DCI, ACI, 2/4-wire , frequency, period
1000 reading/s into internal memory at 4.5 digits
Fast range/function changes
Reading storage with internal memory
Agilent E1412A
Description
The Agilent Technologies E1412A 6.5-Digit Multimeter is a C-size, 1-slot, message-based VXI module. It is identical in electrical design to the E1312A, differing only in size. It delivers the widest functionality in Agilent’s DMM line. It also delivers high performance and Agilent high quality at prices you’d expect to pay for a 5.5-digit DMM.
This multimeter’s wide product functionality includes volts, amps, ohms, and frequency with advanced tests including limit checks to drive a TTL output and dc voltage ratios. Standard measurements include ac/dc voltage, ac/dc
current, 2- and 4-wire , plus frequency/period. When
measuring dcV, this multimeter can deliver 65 range changes per second and 30 function changes per second.
Refer to the Agilent Technologies Website for instrument driver availability and downloading instructions, as well as for recent product updates, if applicable.
2
dc Accuracy ± (% of reading + % of range):
Specifications are for 1-hour warm-up at 6.5 digits.
dc voltage:
Range
(2)
Test Current or Burden Voltage
24 Hour
(1)
23° C ± 1° C
90 Day 23° C ± 5° C
1 Year 23° C ± 5° C
Temperature Coefficient 0° C - 18° C 28° C - 55° C
100.0000 mV 0.0030 + 0.0030 0.0040 + 0.0035 0.0050 + 0.0035 0.0005 + 0.0005
1.000000 V 0.0020 + 0.0006 0.0030 + 0.0007 0.0040 + 0.0007 0.0005 + 0.0001
10.00000 V 0.0015 + 0.0004 0.0020 + 0.0005 0.0035 + 0.0005 0.0005 + 0.0001
100.0000 V 0.0020 + 0.0006 0.0035 + 0.0006 0.0045 + 0.0006 0.0005 + 0.0001
300.0000 V 0.0020 + 0.0018 0.0035 + 0.0030 0.0045 + 0.0030 0.0005 + 0.0003
Range
Resistance:
(3)
Test Current or Burden Voltage
24 Hour
(1)
23° C ± 1° C
90 Day 23° C ± 5° C
1 Year 23° C ± 5° C
Temperature Coefficient 0° C - 18° C 28° C - 55° C
100.0000 1 mA 0.0030 + 0.0030 0.008 + 0.004 0.010 + 0.004 0.0006 + 0.0005
1.000000 k 1 mA 0.0020 + 0.0005 0.008 + 0.001 0.010 + 0.001 0.0006 + 0.0001
10.00000 k 100 µA 0.0020 + 0.0005 0.008 + 0.001 0.010 + 0.001 0.0006 + 0.0001
100.0000 k 10 µA 0.0020 + 0.0005 0.008 + 0.001 0.010 + 0.001 0.0006 + 0.0001
1.000000 M 5 µA 0.002 + 0.001 0.008 + 0.001 0.010 + 0.001 0.0010 + 0.0002
10.00000 M 500 nA 0.015 + 0.001 0.035 + 0.001 0.054 + 0.001 0.0030 + 0.0004
100.0000 M 500 nA || 10 M 0.300 + 0.010 0.800 + 0.010 0.800 + 0.010 0.1500 + 0.0002
Range
dc current: Test Current or
Burden Voltage
24 Hour 23° C ± 1° C
90 Day 23° C ± 5° C
1 Year 23° C ± 5° C
Temperature Coefficient 0° C - 18° C 28° C - 55° C
10.00000 mA <0.1 V 0.005 + 0.010 0.050 + 0.020 0.070 + 0.020 0.005 + 0.0020
100.0000 mA <0.6 V 0.01 + 0.004 0.040 + 0.005 0.070 + 0.005 0.006 + 0.0005
1.000000 A <1 V 0.10 + 0.006 0.130 + 0.010 0.150 + 0.010 0.005 + 0.0010
3.000000 A <2 V 0.70 + 0.020 0.720 + 0.020 0.720 + 0.020 0.005 + 0.0020
dc:dc Ratio:
Range
(2)
100 mV to 300 V: (Input Accuracy) + (Reference Accuracy)
Input Accuracy = accuracy specification for the HI-LO input signal Reference Accuracy = accuracy specification for HI-LO reference input signal
(1) Relative to calibration standards. (2) 20% overrange on all ranges, except 300 Vdc and 3 A range. (3) Specifications are for 4-wire function, or 2-wire using Math Null, Without Math Null, add 0.2 additional error in 2-wire function.
Product Specifications
dc Specifications
Specifications are for 1-hour warm-up at an integration time of 100 PLCs.
dc Summary
dc voltage: 300 V max.
Voltage accuracy (dc): ± 0.0019%
3
Integration Time Normal mode rejection
(1)
100 PLC/1.67s (2s) 60 dB
(2)
10 PLC/167 ms (200 ms) 60 dB
(2)
1 PLC/16.7 ms (20 ms) 60 dB
(2)
<1 PLC/3 ms (800 µs) 0 dB
(1) For power-line frequency ± 0.1%. (2) For power-line frequency ± 1%, subtract 20 dB; for ± 3%, subtract 30 dB.
System Speed
(Speeds are for 4.5 digits, Delay 0 and Autozero OFF. Includes measurement and data transfer over VXI backplane.)
Function change: 30/s
Range change: 65/s Autorange time: <30 ms
Max. internal trigger rate: 1000/s
Max. external trigger rate to memory: 1000/s
dc:dc Ratio
Measurement method: Input HI-LO/Reference HI-LO
Apply “Reference HI-LO” signal to Ohms 4-Wire Sense terminals.”
Input HI to Input LO: 100 mV to 300 V Reference HI to Input LO: <12 V on 100 mV to 10 V ranges
(autoranged)
Reference LO to Input LO: <2 V
Additional Error with Autozero OFF
Following instrument warm-up at calibration temperature ± 1° C and <10 minutes.
100mV-100V ranges: add 0.0002% reading + 5 µV 300 V range: add 0.0006% reading
dc Operating Characteristics
Readings speeds for 60 Hz and (50 Hz) operation, Autozero OFF.
Function NPLC Digits Reading/s Additional Noise
Error
DCV, DCI and 100 6.5 0.6 (0.5) 0% of range DCV, DCI and 10 6.5 6 (5) 0% of range DCV, DCI and 1 5.5 60 (50) 0.001% of range* DCV, DCI and .2 5.5 300 0.001% of range* DCV, DCI and .02 4.5 1,000 0.01% of range*
*For 300 V range: use 0.003% of range for 5.5 digits and 0.030% of range for 4.5 digits. For all ranges: add 20 µV for dc Volts, 4 µA for dc current, or 20 mfor resistance.
Considerations
Settling considerations: Reading settling times are affected by
source impedance, cable dielectric characteristics, and input signal changes.
Measurement considerations: Agilent recommends the use of Teflon
or other high impedance, low­dielectric absorption wire insulation for these measurements.
Measurement method: Continuously integrating, multi-slope
III A/D converter
A/D linearity: 0.0002% of reading + 0.0001% of
range
2/4-wire Ω: 100 M
Input resistance:
0.1 V, 1 V, 10 V ranges: Selectable 10 Mor 10 G 100 V, 300 V ranges: 10 M± 1%
Input bias current: <30 pA at 25° C
Input terminals: Copper alloy
Input protection: 300 V on all ranges
Resistance Measurement method: Selectable 4-wire or 2-wire
(Current
source referenced to low input)
Max. lead resistance: (4-wire ) 10% of range per lead for
100 and 1 kper lead on all other ranges
Input protection: 300 V on all ranges
dc Current
Shunt resistor: 0.1 for 1 A and 3 A, 5 for 10 mA
and 100 mA
Input protection: Externally accessible 3 A, 250 V fuse
Measurement Noise Rejection
60 Hz (50 Hz) (For 1 kunbalance in LO lead.)
dc CMMR: 140 dB
dc Voltage Characteristics
4
ac Accuracy ± (% of reading + % of range):
Specifications are for 1-hour warm-up at 6.5 digits, Slow ac filter, sinewave input.
True RMS ac Voltage
(3)
:
Range
(2)
Frequency 24 Hour
(1)
23° C ± 1° C
90 Day 23° C ± 5° C
1 Year 23° C ± 5° C
Temperature Coefficient 0° C - 18° C 28° C - 55° C
100.0000 mV 3 Hz-5 Hz 1.00 + 0.03 1.00 + 0.04 1.00 + 0.04 0.100 + 0.004
100.0000 mV 5 Hz-10 Hz 0.35 + 0.03 0.35 + 0.04 0.35 + 0.04 0.035 + 0.004
100.0000 mV 10 Hz-20 kHz 0.04 + 0.03 0.05 + 0.04 0.06 + 0.04 0.005 + 0.004
100.0000 mV 20 kHz-50 kHz 0.10 + 0.05 0.11 + 0.05 0.12 + 0.05 0.011 + 0.005
100.0000 mV 50 kHz-100 kHz 0.55 + 0.08 0.60 + 0.08 0.60 + 0.08 0.060 + 0.008
100.0000 mV 100 kHz-300 kHz 5.00 + 0.50 5.00 + 0.50 5.00 + 0.50 0.020 + 0.020
1.000000 V to 300.000 V
(4)
3 Hz-5 Hz 1.00 + 0.02 1.00 + 0.03 1.00 + 0.03 0.100 + 0.003
1.000000 V to 300.000 V
(4)
5 Hz-10 Hz 0.35 + 0.02 0.35 + 0.03 0.35 + 0.03 0.035 + 0.003
1.000000 V to 300.000 V
(4)
10 Hz-20 kHz 0.04 + 0.02 0.05 + 0.03 0.06 + 0.03 0.005 + 0.003
1.000000 V to 300.000 V
(4)
20 kHz-50 kHz 0.10 + 0.04 0.11 + 0.05 0.12 + 0.05 0.011 + 0.005
1.000000 V to 300.000 V
(4)
50 kHz-100 kHz 0.55 + 0.08 0.60 + 0.08 0.06 + 0.08 0.060 + 0.008
1.000000 V to 300.000 V
(4)
100 kHz-300 kHz
(5)
5.00 + 0.50 5.00 + 0.50 5.00 + 0.50 0.200 + 0.020
True RMS ac Current
(3)
:
Range Frequency 24 Hour
23° C ± 1° C
90 Day 23° C ± 5° C
1 Year 23° C ± 5° C
Temperature Coefficient 0° C - 18° C 28° C - 55° C
1.000000 A 3 Hz-5 Hz 1.05 + 0.04 1.05 + 0.04 1.05 + 0.04 0.100 + 0.006
1.000000 A 5 Hz-10 Hz 0.35 + 0.04 0.35 + 0.04 0.35 + 0.04 0.035 + 0.006
1.000000 A 10 Hz-1 kHz 0.15 + 0.04 0.15 + 0.04 0.15 + 0.04 0.015 + 0.006
1.000000 A 1 kHz-50 kHz 0.40 + 0.04 0.40 + 0.04 0.40 + 0.04 0.015 + 0.006
3.000000 A 3 Hz-5 Hz 1.70 + 0.06 1.70 + 0.06 1.70 + 0.06 0.100 + 0.006
3.000000 A 5 Hz-10 Hz 0.95 + 0.06 0.95 + 0.06 0.95 + 0.06 0.035 + 0.006
3.000000 A 10 Hz-1 kHz 0.75 + 0.06 0.75 + 0.06 0.75 + 0.06 0.015 + 0.006
3.000000 A 1 kHz-50 kHz 1.00 + 0.06 1.00 + 0.06 1.00 + 0.06 0.15 + 0.06
(1) Relative to calibration standards. (2) 20% overrange on all ranges, except 300 Vac and 3A ranges which have 1% overrange. (3) 100 mV to 100 V range specifications are for sine wave input >5% of range. For inputs from 1% to 5% of range and <50 kHz, add 0.1% of range additional error. For 50 kHz to 100 kHz, add 0.13% additional error. 300 V range specifications are for sinewave input >15% of range. For inputs from 3% to 15% of range and >50 kHz, add 0.30% of kHz, add
0.40% of range additional error. (4) For 300 V range, use (% reading) shown in table and multiply each (% range) x 3. (5) 300 Vac range limited to 50 kHz. For frequencies >50 kHz, signals must be ≤1.5 x 10
7
VHz.
Additional ac Specifications:
Low Freq. Errors
(% of reading)
Crest Factor Errors
(non-sinewave)*
Frequency ac Filter Crest Factor Error
Slow Medium Fast (% of reading)
10 Hz-20 Hz 0 0.74 1-2 0.05% 20 Hz-40 Hz 0 0.22 2-3 0.15% 40 Hz-100 Hz 0 0.06 0.73 3-4 0.30% 100 Hz-200 Hz 0 0.01 0.22 4-5 0.40% 200 Hz-1 kHz 0 0 0.18 >1 kHz 0 0 0
*For frequencies below 100 Hz, slow ac filter specified for sinewave input only.
Noise Rejection
(For 1 kunbalance in LO lead.)
ac CMMR: 70 dB
ac Specifications
ac Summary
ac voltage: 300 V max.
Voltage accuracy (ac): ± 0.07%
5
True RMS ac Current
Measurement method: Direct couple to the fuse and shunt.
ac-coupled True RMS measurement (measures the ac component only).
Shunt resistor: 0.1 for 1 A and 3 A ranges
Burden voltage:
1A range: <1 Vrms 3A range: <2 Vrms
Input protection: Externally accessible 3 A, 250 V fuse
ac Operating Characteristics
Maximum reading rates 0.01% of ac step additional error. Additional settling delay required when input dc level varies.
Function Digits Reading/s ac Filter
ACV and ACI 6.5 7 s/reading Slow ACV and ACI 6.5 1 Medium ACV and ACI 6.5 1.6
(1)
Fast ACV and ACI 6.5 10 Fast ACV and ACI 6.5 50
(2)
Fast
(1) For External Trigger or remote operation using default settling delay (Delay Auto). (2)Maximum useful limit with default settling delays used.
Systems Speeds
Maximum useful limit with default settling delays used; Speeds are for 4.5 digits, Delay 0, and Fast ac filter.
Function or range change: 5/s Autorange time: <0.8 s
ASCII reading to GPIB: 50/sec
Max. internal trigger rate: 50/s
Max. external trigger rate to memory: 50/s
Additional Low-Frequency Errors (% of reading)
Input >100 mV. For mV input, multiply % of reading error x 10.
Frequency 6.5 digits 5.5 digits 4.5 digits
3 Hz-5 Hz 0 0.12 0.12 5 Hz-10 Hz 0 0.17 0.17 10 Hz-40 Hz 0 0.2 0.2 40 Hz-100 Hz 0 0.06 0.21 100 Hz-300 Hz 0 0.03 0.21 300 Hz-1 kHz 0 0.01 0.07 >1 kHz 0 0 0.02
True RMS ac Voltage
Measurement method: ac-coupled True RMS — measures
the ac component of the input with up to 300 Vdc of bias on any range. (Max ac+dc = 300 V rms.)
Crest factor: Maximum 5:1 at full scale
ac filter bandwidth:
Slow: 3 Hz-300 kHz Medium: 20 Hz-300 kHz Fast: 200 Hz-300 kHz
Input impedance: 1 M±2%, in parallel with 100 pF
Input protection: 300 Vrms all ranges
Specifications are for 1-hour warm-up at 6.5 digits.
Frequency and Period Accuracy (% of reading)
Frequency and Period Specifications
Function Range
(2)
Frequency 24 Hour
(1)
23° C ± 1° C
90 Day 23° C ± 5° C
1 Year 23° C ± 5° C
Temperature Coefficient 0° C - 18° C 28° C - 55° C
Frequency, Period 100 mV to 300 V 3 Hz-5 Hz 0.10 0.10 0.10 0.005 Frequency, Period 100 mV to 300 V 5 Hz-10 Hz 0.05 0.05 0.06 0.005 Frequency, Period 100 mV to 300 V 10 Hz-40 Hz 0.03 0.03 0.03 0.001 Frequency, Period 100 mV to 300 V 40 Hz-300 kHz 0.006 0.01 0.01 0.001
(1) Relative to calibration standards. (2) 20% overrange on all ranges, except 300 Vac range which has 1% overrange.
6
Operating Characteristics
Speeds are for 4.5 digits, Delay 0, and Fast ac filter.
Function Digits Reading/s
Frequency, Period 6.5 1 Frequency, Period 5.5 9.8 Frequency, Period 4.5 80
Systems Speeds
Configuration rates: 14/s Autorange time: <0.6 s
Max. internal trigger rate: 80/s
Max. external trigger rate to memory: 80/s
Characteristics
Warmup time: 1 hour
State storage memory: Power-off state automatically saved
Functions
Idc: 3 A
Iac: 3 A
Frequency: 300 kHz Period: 3.3 µs
Temp.: Tm, Tc, RTD
General Specifications
VXI Characteristics
VXI device type: Message based
Data transfer bus: A16
Size: C
Slots: 1
Connectors: P1/2
Shared memory: n/a
VXI buses: n/a
Instrument Drivers - See the Agilent Technologies Website
(http://www.agilent.com/find/inst_drivers) for driver availability and downloading.
Command module firmware: n/a
Command module firmware rev: n/a
I-SCPI Win 3.1: n/a
I-SCPI Series 700: n/a
C-SCPI LynxOS: n/a
C-SCPI Series 700: n/a
Panel Drivers: No
VXI
plug&play
Win Framework: Yes
VXI
plug&play
Win 95/NT Framework: Yes
VXI
plug&play
HP-UX Framework: No
Module Current
I
PM
I
DM
+5 V: 0.2 0.1 +12 V: 0.7 0.06 –12 V: 00 +24 V: 00 –24 V: 00 –5.2 V 00 –2 V: 00
Cooling/Slot
Watts/slot: 9.40 P mm H
2
O: 0.05
Air Flow liter/s: 0.80
Ordering Information
Description Product No.
6.5-Digit Multimeter, High Accuracy E1412A ANSI Z540 Compliant Calibration E1412A A6J
Measurement method: Reciprocal-counting technique. ac-
coupled input using the ac voltage measurement function.
Voltage ranges: 100 mV rms full scale to 300 V rms.
Auto or manual ranges.
Gate time: 10 ms, 100 ms, or 1 s
Settling considerations: Errors will occur when attempting to
measure the frequency or period of an input following a dc offset voltage change. The input blocking RC time constant must be allowed to fully settle (up to 1 s) before the most accurate measurements are possible.
Measurement considerations: All frequency counters are susceptible
to error when measuring low-voltage, low-frequency signals. Shielding inputs from external noise pickup is critical for minimizing measurement errors.
Max. reading rate: 1K
Measuring Characteristics
Agilent Technologies’ Test and Measurement Support, Services, and Assistance
Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent’s overall support policy: "Our Promise" and "Your Advantage."
Our Promise
Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available.
Your Advantage
Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products.
By internet, phone, or fax, get assistance with all your test & measurement needs.
Online assistance:
www.agilent.com/find/assist
Phone or Fax
United States:
(tel) 1 800 829 4444
Canada:
(tel) 1 877 894 4414 (fax) (905) 282 6495
China:
(tel) 800 810 0189 (fax) 800 820 2816
Europe:
(tel) (31 20) 547 2323 (fax) (31 20) 547 2390
Japan:
(tel) (81) 426 56 7832 (fax) (81) 426 56 7840
Korea:
(tel) (82 2) 2004 5004 (fax) (82 2) 2004 5115
Latin America:
(tel) (305) 269 7500 (fax) (305) 269 7599
Taiwan:
(tel) 0800 047 866 (fax) 0800 286 331
Other Asia Pacific Countries:
(tel) (65) 6375 8100 (fax) (65) 6836 0252 (e-mail) tm_asia@agilent.com
Data Subject to Change © Agilent Technologies, Inc. 2001 Printed in the U.S.A. May 1, 2004 5965-5563E