Agilent 8501A Data Sheet

High-end Analyzer at a Low-end Price
R2590 Communications System Analyzer
2
The R2590 system analyzer sets a new standard for value in two-way communications testing. The unit’s light weight (28 lbs.), small footprint (7” x 13.5” x 12”) and optional battery with two hours of run time combine to make it as valuable in the field as on the bench.
Here are just a few of the features that are standard on every R2590:
1GHz RF Signal Generator with AM/FM/PM
modulation, 1Hz resolution, and output range from –10dBm to –125dBm
Duplex Generator with a fully adjustable
(0 Hz to 1GHz) frequency offset
1GHz RF Receiver with 2µV sensitivity and 1Hz
resolution, frequency error meter with actual fre­quency display, and AM/FM demodulation meters
Broadband and Selective Power Meters
1GHz Spectrum Analyzer with powerful
analytical tools usually found only in expensive stand-alone instruments
50kHz Oscilloscope with voltage and frequency
measurements
Audio Modulation Synthesizer, including:
Dual tone generator, sub-audible tone generator, DTMF generator, and external modulation input
Signal Strength Indicator
SINAD Meter with AUTO Mode
CTCSS, DCS, and DTMF Decoder
6.4” color LCD Display with external VGA output
RS232 Port for computer control and “flash”
software updates
Additional optional features include:
CLEARCHANNEL
LTR
Paging encoder: 2 tone, 5/6 tone, programmable
sequence, POCSAG
Tracking GeneratorCable Fault/Antenna Analyzer with Return
Loss Bridge
Internal battery with up to 2 hours of run time
Powerful, portable, and priced to fit within your budget, the R2590 is the new standard for two-way communica­tions service monitors.
Big solutions on a small budget.
R2590 Communications System Analyzer
3
Standard System Features
Feature Description Benefits
Tracking Generator (option)
View the performance characteristics of many RF devices with this convenient tracking generator. A sweep range from 5 KHz to 1 GHz, with a resolution of 1 Hz, permits accurate device alignment.
Allows the operator to quickly and easily diagnose critical problems with receiver front ends, IFs, helical filters, cavities, combiners and duplexers.
Full Featured Spectrum Analyzer
The R2590 comes complete with a powerful, yet very easy to use spectrum analyzer. Independent Start, Stop, and Span settings permit ready adjustment of the displayed spectrum from a 5 KHz window to a full 1 GHz span width. A fully adjustable reference level, and a set of four individual markers allows for precise measurements of levels and frequencies.
Stop, Average, Peak Hold functions and one-button measurements such as Occupied Bandwidth make for a powerful analyzer that can handle almost any situation.
Our unique ‘Scanning Spectrum Audio’ function replaces the typical ‘look and listen’ capability by tuning the receiver (and the recovered audio) to an adjustable marker frequency, rather than the center frequency of the spectrum display.
The R2590 comes packed with features typically found on stand-alone spectrum analyzers, and much more.
This feature is handy when attempting to identify a variety of signals without the need to continually change the center frequency of the spectrum display.
AM/FM Receiver
With a typical sensitivity of less than 2 microvolts at the antenna port, the R2590 can be used for the off-the-air monitoring of remote transmitters. Variable squelch aids in picking up weak signals, but can be set tighter to ensure the proper S/N ratio for measurement accuracy.
This feature reduces service costs by enabling frequent preventative maintenance checks for system degradation or interference identifica­tion without ever leaving the shop.
AM/FM/PM Generator
The R2590 includes a 250 KHz to 1 GHz AM/FM/PM signal generator that has an adjustable output level from –125 dBm to –10 dBm.
The generator output port is fuse-protected, assuring against damage by the inadvertent application of power, therefore saving a trip to the repair shop.
Selectable metering includes a ‘One Button’ SINAD measurement with adjustable target setting. The R2590 will automatically determine the RF level needed to produce a specified SINAD reading.
This flexible signal generator reduces receiver test time by displaying all the necessary control information simultaneously. The wide range of output levels cover all manner of troubleshooting situations.
The R2590 simplifies routine measurements with ‘One Button’ convenience.
Full Band Duplex Offset Generator
Full output level control from –125 dBm to –10 dBm over the entire frequency range of the instrument is available from the duplex offset generator.
Duplex frequency offsets are also fully variable, from 0 Hz to 1 GHz in 1 Hz steps.
The duplex generator provides enhanced capability to service equipment such as repeaters and full duplex radios.
The 1 Hz frequency offset resolution extends functionality to cross-band repeaters and component level receiver and transmitter troubleshooting.
4
Feature Description Benefits
Standard System Features – continued
Broadband and Selective Power Meters
The built-in power meter automatically switches from a selective meter at low power levels, to a true RMS broadband meter at higher power levels. Accurate power meter measurements can be made up to 150 Watts.
Accurately make true RMS power meter measurements without a stand-alone power meter, or bulky external attenuators. The R2590 can safely dissipate up to 200 watts of RF power, 150 watts continuously (@20˚C).
Electronic Software Updates
A high speed serial port and flashable memory permit programming firmware updates from an external PC. The standard bi-directional RS232 port is also available for remote control of the R2590 by an external controller.
Quick and easy access to future software updates.
Cable Fault/Antenna Analyzer (Option)
The return loss bridge included with the Antenna Analyzer option is specially designed to interface to the R2590. It plugs directly into the ‘antenna in’ and ‘generate out’ ports – no external cables needed.
In conjunction with the tracking generator feature, it allows you to view the frequency characteristics of an attached antenna, while providing a one-button measurement for both SWR and return loss.
The Cable Fault feature assists the technician with isolating cable defects and anomalies. A high precision, FFT based Frequency Domain Reflectometer (FDR) allows fault analysis out to 800 feet, with a resolution down to 4 inches.
Quickly and easily verify the tuned frequencies of an antenna.
Visually determine the operating characteristics of an antenna.
This feature allows validation of cable performance by detecting high insertion loss and faulty connectors and couplers, while also verifying cable lengths. In addition, quick setup, and fully automatic operation, maximize your on-site productivity.
High Stability Oscillator (Option)
The standard oscillator in the R2590 is an OCXO rated at a temperature stability of .2 ppm. With a warm-up time of less than 3 minutes, you can quickly be assured of accurate test results.
The optional high stability oscillator is also an OCXO, yet increases the temperature stability to .02 ppm. Accuracy is guaranteed within 5 minutes of turn-on.
Be assured of accurate frequency measurements within minutes of turn-on.
Current consumption of the high stability oscillator is comparable to the standard oscillator, causing minimal effect on battery life.
Audio Modulation Synthesizer
The standard audio modulation synthesizer includes dual tone, DTMF, and PL/DPL (CTCSS/DCS) generators. The dual tone generators are fully adjustable up to 25 KHz in .1 Hz steps.
The optional paging encoder adds support for 5/6 tone, 2-tone, a user defined programmable sequence, plus digital paging formats.
This feature ensures overall system performance by providing readily available built-in modulation sources.
Internal Battery/External DC Operation
The R2590 can be powered from a variety of AC and DC sources. When on the bench, the AC mains will automatically accept from 100 VAC to 240VAC (50 to 60 Hz). At remote loca­tions, the R2590 can be powered from external DC sources. For the ultimate in versatility, the internal battery option will power the unit for up to 2 hours. The built-in charger keeps the battery fully charged when plugged in to an AC source.
The R2590 was designed to go where you go. Typical power consumption when used with a DC power source is only 35 watts, assuring extended operation when used in remote field locations.
5
Feature Description Benefits
Standard System Features – continued
CLEARCHANNEL LTR (Option)
The CLEARCHANNEL LTR trunking option adds the capability to simulate an LTR repeater system. Complete versatility is provided by selectable messaging parameters including; Area, Goto/In Use, Home, Group, and Free.
An “Auto Setup” function simplifies data entry by automatically capturing the repeater and mobil data settings.
Selectable messaging types, such as Continuous, Idle, Busy, Oneshot, and Handshake, permit comprehensive troubleshooting of LTR repeater systems.
One button configuration of the R2590 minimizes setup errors, and allows more time for troubleshooting the LTR radio system.
SPECTRUM ANALYZER
Range: 250 KHz – 1.0 GHz
Frequency Resolution: 1 Hz
Frequency Span: 5 KHz to 1.0 GHz (0 KHz)
Resolution
Bandwidth Filters: 3 KHz to 3 MHz (1-10 sequence)
Sweep Time: 50 mS to 30 S
Dynamic Range: 80dB
Reference Level: -50 dBm to +60 dBm (0.1 dBm steps)
Video Bandwidth Filters: 1 KHz to 3 MHz (1-3-10 sequence)
Display Range: +60 to -130 dBm
Vertical Resolution: .25 dB
Log Linearity: ±2 dB (-90 dB to –20 dB)
Additional Functions: Video Average (2 to 255 traces), Freeze,
Peak Hold, Track Peak, Occupied Bandwidth, Return Loss, N dB points (N=0 to –70.0 dBm), Full Band Peak Search
Markers (4): Delta or absolute frequency and level
Marker Audio: Continuous, Toggle
SIGNAL STRENGTH
INDICATOR
(Antenna Port)
Range: 250 KHz – 1.0 GHz
Sensitivity: -85 dBm
Accuracy: ±4 dB
POWER METER
(RF I/O Port)
Measurement Range: 0.25W to 150W (Broadband Meter),
5 MHz to 1 GHz.
Input Impedance: 50 ohms, max VSWR of 1.5:1
Accuracy: ±1.5 dB (input level <+35 dBm), ±15%
(input level >3W to 50W), ±10% (input level >50W). 125 MHz to 1 GHz.
Maximum
Continuous Rating: 150W (@ 20˚C)
Intermittent Rating: 250W for limited periods. High
temperature overload warning.
FREQUENCY
Range: 250 KHz – 1.0 GHz
Resolution: 1 Hz
Accuracy: Refer to Accuracy of Master Oscillator
ANTENNA INPUT
PROTECTION Antenna Port: 10 W (with audible alarm)
SENSITIVITY (FM): <2.0 µV typical
FREQUENCY
ERROR METER
Type of Displays: Auto ranging plus actual frequency
Resolution: 1 Hz
Range: 0 Hz to 10 KHz
FM DEVIATION
MEASUREMENT
Demodulation Range: Up to ±80 KHz
Accuracy: ±10%
Frequency Response: Selectable 300 Hz LP, 300 Hz HP, 4KHz
LP, 4KHz HP, 20 KHz LP, 0.3 – 4.0 KHz BP, 1 KHz Notch
De-emphasize: Selectable 680 µS, 470 µS, 68 µS
AM DEMODULATION
MEASUREMENTS
Demodulation Range: 0 to 90%
Accuracy: ±10%
Frequency Response: Selectable 300 Hz LP, 300 Hz HP, 4KHz
LP, 4KHz HP, 20 KHz LP, 0.3 – 4.0 KHz BP, 1 KHz Notch
DUAL MODULATION
SOURCE
Frequency Range: 200 Hz to 25 KHz
Frequency Resolution: 0.1 Hz
Tone Distortion: <1% THD (sine waveform)
Wave shapes: Sine
SUB-AUDIBLE
TONE GENERATOR:
Frequency Range: 30 Hz to 300 Hz
Frequency Resolution: 0.1 Hz
Tone Distortion: <1% THD @ 100 Hz
Formats: PRIVATE LINE (CTCSS), and DIGITAL
PRIVATE LINE (DCS and DCS Inv)
DTMF GENERATOR
Digits: 0-9, *, #, A, B, C, D.
Duration: 0 to 5 S in 1 mS steps
Pause: 0 to 5 S in 1 mS steps
Twist: -20.0 to +20.0 dB in 0.1 dB steps
FREQUENCY
Range: 250 KHz – 1.0 GHz
Resolution: 1 Hz
Accuracy: Refer to Master Oscillator
INPUT PROTECTION
Generate Port: 0.25 W
RF I/O Port: 200 W
OUTPUT
Generate Port: -80 dBm to -10 dBm
RF I/O Port: -125 dBm to -60 dBm
Accuracy: ±4 dB
DUPLEX GENERATOR
Range: 250 KHz – 1.0 GHz
Frequency Resolution: 1 Hz
Output Level: -125 dBm to -10 dBm
Frequency Offset: 0 to 1 GHz in 1 Hz steps
Accuracy: Same as Signal Generator
SPECTRAL PURITY
Spurious: -30 dBc
Harmonics: -20 dBc
FM MODULATION
Deviation Range: 0 to 250 KHz
Accuracy: Same as Master Oscillator
Residual FM: 20 Hz max @ 300 Hz - 3 KHz from fc
Internal
Frequency Range: See Modulation Synthesizer
External
Frequency Range: 0 Hz to 5.0 KHz
External
Modulation Sensitivity: User Adjustable
AM MODULATION
Range: 0-90%
Accuracy: Same as Master Oscillator
Residual AM: 1.0% max @ 300 to 3 KHz from fc
Internal
Frequency Range: See Modulation Synthesizer
External
Frequency Range: 0 Hz to 5.0 KHz
External
Modulation Sensitivity: User Adjustable
PHASE MODULATION
Range: 0.01 to 10 radians
Accuracy: Same as Master Oscillator
Resolution: .01 radians
Internal
Frequency Range: See Modulation Synthesizer
External
Frequency Range: 0 Hz to 5.0 KHz
External
Modulation Sensitivity: User Adjustable
6
RF SIGNAL GENERATOR
RF RECEIVER
METERING AND MEASUREMENT
AUDIO MODULATION SYNTHESIZER
Technical Specifications
PAGING ENCODER (OPTIONAL)
5/6 Tone: EIA, CCIR, ZVEI1, ZVEI2, DZVEI, PZVEI,
EEA, NATEL, MODAT
Two-tone: Motorola, GE, Reach, and NEC
Custom: 9 tone programmable sequence
Digital: POCSAG
Display: 6.4” Diagonal TFT color LCD
Line Voltage: 100 - 240 VAC (50 to 60 Hz)
AC Input Fuse: 1 amp Slow-blow fuse
DC Input: +11 to +15 VDC, 35 watts typical DC Current Draw: 3 amps max. DC Input Polarity: Tip positive, sleeve ground
Battery Option: 7 AH, 12 V, up to 2 hours run time
Dimensions: 7.0” high x 13.5” wide x 12” deep,
(17.7 cm x 34.2 cm x 30.5 cm)
Weight: 28 pounds (Base model excluding
options and accessories)
Temperature: 0 to +50˚C (operating),
-40 to +85˚C (storage)
REAR PORTS
RS232: Bi-directional port for instrument
control and software updates. Baud rates to 115,200 bps, DB-9
VGA: Drives a standard VGA Display
Monitor, DB15
AC Input: 1 AMP slo-blow fused
DC Input: External DC power source, 2.5 mm
Tone Out: Tone generator output, BNC
Demod Out: Receiver demodulation, BNC
10 MHz Reference: Selectable internal/external reference
oscillator signal, BNC
FRONT PORTS
Antenna: Low level RF inputs (<0 dBm), BNC
Generate: High Level RF Output, BNC (fused)
Scope / Ext Mod In: External modulation and Oscilloscope
input, BNC
RF I/O: Bi-directional RF, type “N”
MIC: External modulation input, RJ-45
HEADPHONE: 1/8” headphone jack for private
monitoring of speaker output
Part No. Description
R2590A Communications System Analyzer
Includes US power cord and operators manual.
R2590AP R2590 Plus package
Includes the R2590A and the following options as standard equipment: RLN5303A, RLN5304A, RLN5308A, and the RLN5378A.
Options and accessories
RLN5303A High Stability Oscillator
Replaces standard internal frequency reference
RLN5304A Tracking Generator
Tracked and fixed generator output with selectable sweep from 5KHz to 1 GHz.
RLN5305A Paging Protocols
Includes 5/6 tone (EIA, CCIR, ZVEI1, ZVEI2, DZVEI, PZVEI, EEA, NATEL, MODAT), 2-tone (Motorola, Reach, GE, NEC), custom 9 tone programmable sequence, and POCSAG.
RLN5306A CLEARCHANNEL LTR™ RLN5308A Cable Fault/Antenna Analyzer
Includes return loss bridge. Requires option RLN5304A.
RLN5333A Internal Battery
12V, 7 AH. Provides typical run-time of 2 hours
RLN5378A Accessory Kit
Includes antenna, microphone, BNC to N adapter, serial programming cable, oscilloscope probe, and DC power connection kit.
1580384M96 Canvas case with accessory pocket
R2590 Model Nomenclature
TRACKING GENERATOR (OPTIONAL)
Range: 250 KHz – 1.0 GHz
Tracking or Fixed Generator output
Sweep Range: 5 KHz to 1.0 GHz
Display Range: +60 to -130 dBm
OSCILLOSCOPE
Frequency Response: 0 to 50 KHz (-3 dB point)
Vertical Input Range: 5 mV to 50 V per division
Coupling: AC, DC
Maximum Input: 100 Vpk
Sweep Ranges: 20 µS to 10 mS per division
Trigger: Automatic, normal
Additional Functions: AC Voltmeter (RMS and pk to pk),
DC Voltmeter, Frequency and Period Counter
Markers: Delta Voltage, Frequency, and Time
SINAD METER
Input Level: .5 V to 10 V pk-pk
Range: 1 to 20 dB
Resolution: 0.1 dB
Accuracy: ±1 dB at 12 dB SINAD
TONE DECODE
Modulation Types: PRIVATE LINE (CTCSS), and DIGITAL
PRIVATE LINE (DCS and DCS Inv with error display), DTMF
TIME BASE
Standard: Aging 1 ppm/yr, Temperature 0.5 ppm
Optional: Aging .5 ppm/yr, Temperature .05 ppm
7
POWER AND ENVIRONMENTAL
8201 E. McDowell Road Scottsdale, AZ 85252 • Please call the General Dynamics representative in your area for assistance with product information, pricing and orders. In the United States • Telephone: 877-449-0600 (Toll Free) • FAX: 480-441-7169 Web Site: www.gdc4s.com/cte
B-R2590-2-0803
R2590 Communications System Analyzer
All trademarks indicated as such herein are trademarks of General Dynamics ® Reg. U.S. Pat. & Tm. Off. All other product or service names are the property of their respective owners. © 2003 General Dynamics. All rights reserved. General Dynamics reserves the right to make changes in its products and specifications at any time and without notice.
Service, maintenance and technical support
For support on General Dynamics test equipment contact:
United States and Canada:
General Dynamics C4 Systems Communications Test Equipment 8201 E. McDowell Road, H755 Scottsdale, AZ 85252 Phone: 877-449-0600 or 480-441-0664
Europe, the Middle East, and Africa:
Motorola Test Equipment Service Center Heinrich-Hertz Strasse 1 65232 Taunusstein-Neuhof Phone: +49-6128-700
Asia and the Pacific Rim (excluding Japan):
Motorola Electronics Pte Ltd Motorola Innovation Centre, CGISS-7th Floor 12 Ang Mo Kio Street 64 Ang Mo Kio Industrial Park 3 Singapore 569088 Phone: +65-6486-3256 Fax: +65-6486-3257
Service is also available in other areas around the world. Please contact your local General Dynamics sales or service representative for the facility nearest you.
Japan:
Nextec Japan Ltd 3-24-22 Kita-Yamada Tsuzuki-ku Yokohama, Japan 224 Phone: +81-045-410-2287 Fax: +81-045-592-0994
Australia and New Zealand:
Australian Support Center Motorola Australia Pty Ltd 10 Wesley Court Tally Ho Business Park East Burwood, VIC 3151 Australia Phone: +61-3-9847-7725 Fax: +61-3-9847-7755
“Test Drive” the R2590 today!
Download the R2590 simulator program by visiting our Website: www.gdc4s.com/cte
Loading...