Agilent 83711B Data Sheet

5
HP 83711B HP 83712B HP 83731B HP 83732B
206 CW and High-Performance Microwave
Signal Sources
Typical single-sideband phase noise at 50 MHz, 1 GHz and 20 GHz, 25˚ C, CW mode. Offsets less than 100 Hz require the high stability timebase, Option 1E5.
HP 83711B/12B and HP 83731B/32B 2 Signal Sources
Clean Signals with Plenty of Power
Choose the HP 83711B/83731B, 1 to 20 GHz, or the HP 83712B/ 83732B, 10 MHz to 20 GHz, for your receiver and system test applications. Fun­damental oscillators and switched low-pass filters deliver < –55 dBc har­monics, eliminate subharmonics, and suppress spurious to < –60 dBc. These signal sources provide plenty of output power (typically > + 14 dBm), while spectral purity is maintained even at high power levels (typical out­put power at frequencies below 1 GHz is + 20 dBm). These signal sources deliver >100 dB dynamic range. Level resolution is 0.01 dB with typical accuracy of ±1.0 dB at any frequency or power level. User Level Correction simplifies generating accurate, leveled power at distant test ports.
HP 83731B and HP 83732B Provide Unmatched Modulation Performance
Sophisticated modulation lets you simulate real-world signals. Test state-of-the-art radar and EW receivers with high-fidelity pulse modula­tion. < 10 ns pulse rise/fall times, < 25 ns pulse width, and > 80 dB pulse on/off ratio give you the per formance you need to verify modern receivers. A built-in multimode pulse generator adds the flexibility to generate triggered, doublet and gated burst pulse modes.
In addition, logarithmic and linear AM is a standard feature in the HP 83731B/32B. Use the > 60 dB depth log AM and the fast pulse mod­ulation simultaneously (scan modulation) for accurate simulation of antenna scanning patterns, or sweep power linearly and accurately to test power-sensitive devices.
The HP 83731B/32B offer unmatched per for mance for testing satellite communications and telemetry r eceivers. 10 MHz peak FM and optional 100 radians peak phase modulation deviations, combined with the highest-modulation index available (> 300 for FM), simplify simulation of these difficult-to-generate signals. The HP 83731B/32B remain fully synthesized even at high-modulation indices, eliminating the troublesome frequency drift of other signal sources.
Real-world signals often combine two or more modulations. The HP 83731B/32B let you use all three modulations simultaneously with optional independent internal modulation generator without any degra­dation in perfor mance. FM and phase modulation cannot be applied simultaneously.
Versatile and Reliable
The HP 83711B/12B and HP 83731B/32B signal sources are the recom­mended local oscillators for the HP 8970B noise figure meter. Low broad­band noise minimizes errors in measurements of low gain devices. Use these signal sources with the HP 83550 series millimeter-wave modules to generate signals to 110 GHz. All front-panel functions are completely GPIB-programmable and SCPI-compatible.
These signal sources are designed to remain within factory speci­fications for the entire life of the instrument. The recommended two­year perfor mance verification cycle minimizes downtime and cost of ownership. If a unit ever drifts, automated adjustment routines can be run to retur n the unit to factory performance in less than six hours. Extensive use of surface-mount technology and a minimum number of adjustments combine to deliver an estimated MTBF of more than 20,000 hours. Built-in functional verification routines speed servicing.
Key Literature
HP 83711B/12B and HP 83731B/32B Technical Data Sheet, p/n 5963-6615E
Specifications
Frequency Characteristics Frequency Range:
HP 83711B, 1.0 to 20 GHz HP 83712B, 10 MHz to 20 GHz HP 83731B, 1.0 to 20 GHz HP 83732B, 10 MHz to 20 GHz
Frequency Resolution:1 kHz, 1 Hz with Option 1E8
Internal Reference Oscillator
Frequency:10 MHz Timebase Stability:
Standard Timebase Option 1E5
Aging Rate < 1.0 x 10–8⁄day < 1.5 x 10
–9
⁄day
Temperature < 5 x 10
–6
< 1 x 10
–7
Line Voltage N/A < 5 x 10
–10
(10% change in voltage)
Timebase Accuracy= ± aging rate ± temperature effects ±line voltage effects
Output Characteristics
Output Power(with Option 1E1):0.01 to 1 GHz + 13 dBm Maximum Leveled Output Power:1 to 18 GHz + 10 dBm; 18 to
20 GHz + 8 dBm
Minimum Leveled Output Power:–4 dBm; with Option 1E1, –110 dBm
5
HP 83711B HP 83712B HP 83731B HP 83732B
207CW and High-Performance Microwave
Signal Sources
Typical single-sideband phase noise at 50 MHz, 1 GHz, 10 GHz and 20 GHz, 25˚ C, CW mode. Offsets less than 100 Hz require the high-stability timebase, Option 1E5.
SSB phase noise (dBc/Hz, CW mode):
Offsets
Carrier Freq. 100 Hz 1 kHz 10 kHz 100 kHz
0.5 to <1 GHz -78 -92 -103 -115 1 to <2 GHz -73 -83 -92 -107 2 to <5 GHz -70 -78 -83 -100 5 to <10GHz -69 -78 -82 -100 10 to 20 GHz -65 -73 -76 -100
Phase noise decreases 6 dB/octave below 500 MHz and reaches a floor of <-140 dBc/Hz.
General Specifications
Operating Temperature Range:0˚ to + 55˚ C Size:426 mm W x 133 mm H x 498 mm D (16.8 in x 5.2 in x 19.6 in) Weight:< 16 kg (35 lb) Power:90 to 132 V , 48 to 440 Hz; 198 to 264 V, 48 to 66 Hz; 400 V A max. EMC:Meets or exceeds EN55011/CISPR 11/1990, Class A and
MIL-STD-461C Part 2 RE02, CE03, CS02, RS03
HP 83731B, 83732B Modulation Specifications
Pulse Modulation
On/Off Ratio:> 80 dB Rise/Fall Times:< 10 ns Minimum Pulse Width:< 25 ns, 1 to 20 GHz
Internal Multimode Pulse Modulation Source
Modes:Internal free-run, triggered, doublet, and gated burst modes Pulse Repetition Frequency:3 Hz to > 3 MHz Pulse Width:25 ns to 419 ms Pulse Delay:–419 ms to +419 ms, free-run mode; 225 ns to 419 ms,
triggered mode
Minimum Pulse Parameter Resolution:25 ns
Frequency Modulation
Rates:1 kHz to 1 MHz Maximum Deviation:10 MHz pk, 2 to 20 GHz; 5 MHz pk, 1 to 2 GHz;
decreases by a factor of 2 for each octave below 1 GHz
Maximum Modulation Index:> 300
Option 800 Analog Phase Modulation
Sensitivity:Two ranges Maximum Deviation:
Frequency Low range High range
2 to 20 GHz 4 rad 200 rad 1 to 2 GHz 2 rad 100 rad
0.5 to 1 GHz 1 rad 50 rad
0.256 to 0.5 GHz 0.5 rad 25 rad
Logarithmic Amplitude Modulation
Depth:> 60 dB Sensitivity:–10 dB/V Step Response:< 5 µs for 50 dB step
Linear Amplitude Modulation
Sensitivity:Two ranges selectable: 30% Vpk+ 100% V
pk
Maximum Depth:90% (> 90% typical)
Key Literature
HP 83711B/12B and HP 83731B/32B Technical Data, p/n 5963-6615E
Ordering Information
HP 83711BSynthesized CW Generator HP 83712BSynthesized CW Generator HP 83731BSynthesized Signal Generator HP 83732BSynthesized Signal Generator
The following options apply to all models:
Opt 1E1Add 110 dB Output Step Attenuator Opt 1E2Add High-Performance Modulation Generator
1
Opt 1E5Add High-Stability Timebase Opt 1E8Add 1 Hz Frequency Resolution Opt 1E93.5 mm RF Output Connector Opt 800Add Analog Phase Modulation
1
Opt 0B0Delete Manual Set Opt 0B1Extra User’ s Guide Opt 0BVService Manual (Component Level) Opt 0BWService Manual (Assembly Level) Opt 0BXService Manual (Assembly
and Component Level)
Opt 1CMRackmount Kit (HP p/n 5062-3977) Opt 1CPRackmount and Handle Kit (HP p/n 5062-3983) Opt 1CRRack Slide Kit (HP p/n 1494-0059) Opt W30Three Additional Years Return-to-HP Service:
HP 83711B HP 83712B HP 83731B HP 83732B
1
Available on the HP 83731B/32B only.
Resolution:0.01 dB Accuracy(–4 dBm to maximum specified leveled output power):
10 MHz to 50 MHz, ±1.3 dB 50 MHz to 20 GHz, ±1.0 dB
Accuracy(over all specified temperatures, and power levels):
10 MHz to 50 MHz, ±2.3 dB 50 MHz to 20 GHz, ±2.0 dB
Flatness:±0.5 dB
Spectral Purity
Harmonics:
HP 83711B/83712B, < –50 dBc (at levels < + 6 dBm) HP 83731B/83732B, < –55 dBc (at levels < + 6 dBm)
Sub-Harmonics:None Non-Harmonic Spurious(> 3 kHz):–60 dBc Phase Noise(@ 10 kHz offset):500 MHz: –103 dBc/Hz;
2 GHz: –92 dBc/Hz; 18 GHz: –76 dBc/Hz (Phase noise decreases 6 dB/octave below 500 MHz and reaches a floor of < –140 dBc/Hz)
Internet URL www.hp.com/go/tmc00 Product & Order Info See page 607
Loading...