Agilent Part Number: 87421-90001
Printed in USA
April 2001
Supersedes: September 1998
Notice
The information contained in this document is subject to change without
notice.
Agilent Technologies makes no warranty of any kind with regard to this
material, including, but not limited to, the implied warranties of
merchantability and fitness for a particular purpose. Agilent Technologies
shall not be liable for errors contained herein or for incidental or
consequential damages in connection with the furnishing, performance, or
use of this material.
Agilent Technologies assumes no responsibility for the use or reliability of
its software on equipment that is not furnished by Agilent Technologies.
This document contains proprietary information which is protected by
copyright. All rights are reserved. No part of this document may be
photocopied, reproduced, or translated to another language without prior
written consent of Agilent Technologies.
Restricted Rights Legend
Use, duplication, or disclosure by the U.S. Government is subject to
restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical
Data and Computer Software clause at DFARS 252.227-7013 for DOD
agencies, and subparagraphs (c)(1) and (c)(2) of the Commercial Computer
Software Restricted Rights clause at FAR 52.227-19 for other agencies.
Agilent Technologies, Inc.
Santa Rosa Systems Division
1400 Fountaingrove Parkway
Santa Rosa, CA 95403-1799, U.S.A.
CertificationAgilent Technologies certifies that this product met its published
specifications at the time of shipment from the factory. Agilent Technologies
further certifies that its calibration measurements are traceable to the
United States National Institute of Standards and Technology (NIST,
formerly NBS), to the exte nt allowed by the Institute’s calibration facility,
and to the calibration facilities of other International Standards
Organization members.
WarrantyThis Agilent Technologies system product is warranted against defects in
materials and workmanship for a period corresponding to the individual
warranty periods of its component products. Instruments are warranted for a
period of one year . During the w arranty period, Agile nt T echnol ogies will, at
its option, either repair or replace products that prove to be defective.
W ar ranty ser vice for products i nstalle d b y Agilent an d certain other p roducts
designated by Agilentwill be performed at Buyer’s facility at no charge
within Agilent service travel areas. Outside Agilent service travel areas,
warranty service will be performed at Buyer’s facility only upon HP’s prior
agreement and Buyer shall pay HP’s round trip travel expenses. In all other
areas, products must be returned to a service facility designated by HP.
For products returned to Agilent for wa rranty servi ce, Buyer shall prepay
shipping char ges to Agilent and Agilent s hall pay shipping char ges to return
the product to Buyer. However , Buyer shall pay all shipping charges, duties,
and taxes for products returned to Agilent from another country.
Agilent warrants that its software and firmware designated by Agilent for
use with an instrument will execute its programming instructions when
properly installed on that instrument. Agilent does not warrant that the
operation of the instr ument, or softw are, or fir mware will be un interrupted or
error free.
LIMITATION OF WARRANTY. The foregoing warranty shall not apply
to defects resulting from improper or inadequate maintenance by Buyer,
Buyer-supplied software or interfacing, unauthorized modification or
misuse, operation outside of the environmental specifications for the
product, or improper site preparation or maintenance.
NO OTHER WARRANTY IS EXPRESSED OR IMPLIED. AGILENT
SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OR
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
EXCLUSIVE REMEDIES. THE REMEDIES PROVIDED HEREIN ARE
BUYER’S SOLE AND EXCLUSIVE REMEDIES. AGILENT SHALL
87421/22A Operating and Service Manual iii
NOT BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER BASED
ON CONTRACT, TORT, OR ANY OTHER LEGAL THEORY.
AssistanceProduct maintenance agreements and other customer assistance agreements
are available for Agilent Technologies products.
For assistan ce, ca ll your local Agi lent Technologies Sales and Service Of f ice
(refer to “Service and Support” on page v).
iv 87421/22A Operating and Service Manual
Service and Support
By internet, phone, or fax, get assistance with all your test and measurement needs.
Online assistance: www.agilent.com/find/assist
United States
Review this product and related documentation to familiarize yourself with
safety markings and instructions before you operate the instrument. This
product has been designed and tested in accordance with international
standards.
WARNING The WARNING notice denotes a hazard. It calls attention to a procedure,
practice, or the like, that, if not correctly performed or adhered to, could result
in personal injury. Do not proceed beyond a WARNING notice until the
indicated conditions are fully understood and met.
CAUTION The CAUTION notice denotes a hazard. It calls attention to an operating
procedure, practice , or t he like, which, if not correctly performed or adhered
to, could result in damage to the product or loss of important data. Do not
proceed beyond a CAUTION notice until the indicated conditions are fully
understood and met.
Instrument Markings
When you see this symbol on your instrument, you should refer to the instrument’s
instruction manual for important information.
!
This symbol indicates hazardous voltages.
The laser radiation symbol is marked on products that have a laser output.
This symbol indicates that the instrument requires alternating current (ac) input.
The CE mark is a registered trademark of the European Community. If it is
accompanied by a year, it indicates the year the design was proven.
The CSA mark is a registered trademark of the Canadian Standards Association.
1SM1-AThis text indicates that the instrument is an Industrial Scientific and Medical Group 1
Class A product (CISPER 11, Clause 4).
This symbol indicates that the power line switch is ON.
This symbol indicates that the power line switch is OFF or in STANDBY position.
vi 87421/22A Operating and Service Manual
Safety and Regulatory Information
Safety Earth
Ground
This is a Safety Class I product (provided with a protective earthing
terminal). An uninterrup ti ble saf et y ear th gr ound must be pr o vided from the
main power source to the product input wiring terminals, pow er cord, or
supplied power cord set. Whenever it is likely that the protection has been
impaired, the product must be made inoperative and secured against any
unintended operation.
Befor e Applying PowerVerif y that the pro duct is configured to match the available main power
source as d escribed in the input power c onfiguration instructions in this
manual. If this product is to be powered by autotransformer, make sure the
common terminal is connected to the neutral (grounded) side of the ac power
supply.
87421/22A Operating and Service Manual vii
Safety and Regulatory Information
viii 87421/22A Operating and Service Manual
Declaration of Conformity
Declaration of Conformity
87421/22A Operating and Service Manual ix
87421/22A Power Supply
The 87421A and 87422A power supplies are universal input, dc switching
power supplies designed to provide the bias voltages needed to operate
microwave system amplifiers.
87421A Power SupplyThe 87421A is a 25 watt,
83006A, 83017A, and 87415A microwave system amplifiers.
•The power suppl y includes an A C po wer cor d with protect i ve grou nd for
connection to 90-240 Vac.
•Also included is a 2 meter cable wi th a 3-pin conne ctor on one end and a
D-subminiature connector (83006-60005) on the other end for direct
connection to the microwave system amplifiers.
The 87421A may also be used to provide bias voltages for the 83440C high
speed lightwave converter. Using the 83440-60009 lightwave converter
power supply adapter, the 87421A becomes a compact convenient power
supply for use with the lightwave converter.
12 V dc power supply designed to power the
±
Figure 187421A Power Supply Diagram
87421/22A Operating and Service Manual 1
87421/22A Power Supply
87422A Power SupplyThe 87422A is a 90 watt,
83020A microwa v e system power amplifie r. One additional ±12 V dc output
is provided to power a preamplifier such as the 83006A or 83017A.
The power supply includes an AC power cord with protective ground for
connection to 90-240 Vac and two 2 meter cables:
•one cable (83006-60005) with a 3-pin connector on one end and a
D-subminiature connector on the other end
•one cable (87422-60001) for direct connection to the 83020A amplifier
15 V power supply designed to power the
±
Figure 287422A Power Supply Diagram
2 87421/22A Operating and Service Manual
Specifications
Table 1 Specifications
Product Specifications
Model Number87421A87422A
Specifications
Output voltage/current+ 12 V at 2 A
- 12 V at 200 mA
Output power25 W90 W
Line regulation0.1%0.1%
Load regulation
(20% to full load)
Output ripple25 mV RMS max25 mV RMS max
Output noise2% peak to peak max2% peak to peak max
Overvoltage limit protectedYesYes
Short circuit protectionCurrent limited for overload and
AC input voltage90-250 Vac, 50/60 Hz90-240 Vac, 50/60 Hz
Fuse1 A, slow blowT 3.15 A
2.0%1.0%
short circuit protection. Normal
operation returns upon removal
of overload.
General Specifications
+ 15 V at 4.0 A
-15V at 20 mA
+12V at 2 A
-12V at 200mA
Current limited for overload and
short circuit protection. Normal
operation returns upon removal of
overload.
Weight0.9 kg (2.0 lb)2.1 kg (4.6 lb)
Shipping Weight1.8 kg (4.0 lb)3.2 kg (7.0 lb)
Environment Specifications
0
Operating temperature0
Storage temperature-40
C to +550 C full load0 0 C to +550 C full load
0
C to +700 C-40
Product Safety
CAN/CSA 234
!EC 1010
UL 1950
0
C to +700 C
CAN/CSA 234
!EC 1010
UL 1950
×
87421/22A Operating and Service Manual 3
Operating and Service
Operating and Service
Operating Instructions To operate the power supplies, connect the power supplies output to the
amplifier dc input with the cable provided. The power supplies include a
power cord with protective ground for connection to 90-240 Vac.
Mounting holes are provided as shown in the diagrams. The power supplies
may be mounted in any orientation with user supplied hardware.
NOTE
•To ensure continued compliance to product safety and EMC
specifications, connect the power supplies to an amplifier only with the
cable provided.
•Do not attempt to modify or extend the dc output cable. Contact your
local Agilent Technol ogies Sales a nd Service office for help with s pecial
applications requiring longer cables.
Fuse Replacement The power supplies have a fuse located next to the IEC appliance inlet. If it
is necessary to replace the fuse, disconnect the power supply from both AC
power and the amplifier. Using a slotted screw driver, open the fuse cover
and replace the fuse.
Service Information The power supplies contain no user serviceable parts (with the exception of
the fuse). If service is required, contact your nearest Agilent Technologies
Service Center. Refer to“Service and Support” on pagev.
Available Instruments
and Accessories
•83006A microwave system amplifier 0.01-26.5 GHz
•83017A microwave system amplifier 0.5-26.5 GHz
•83018A microwave system amplifier 2-26.5 GHz
•83020A microwave system power amplifier 2-26.5 GHz
•87415A microwave system amplifier 2-8 GHz
•83440C high speed lightwave converter dc-20 GHz, 1000-1600 nm
•83440-60009 lightwave converter power supply adapter
487421/22A Operating and Service Manual