Agilent 83006A Operations Guide

87421/22A Power Supply
Operating and Service Manual
Agilent Part Number: 87421-90001 Printed in USA April 2001 Supersedes: September 1998
The information contained in this document is subject to change without notice.
Agilent Technologies makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material.
Agilent Technologies assumes no responsibility for the use or reliability of its software on equipment that is not furnished by Agilent Technologies.
This document contains proprietary information which is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated to another language without prior written consent of Agilent Technologies.
Restricted Rights Legend
Use, duplication, or disclosure by the U.S. Government is subject to restrictions as set forth in subparagraph (c)(1)(ii) of the Rights in Technical Data and Computer Software clause at DFARS 252.227-7013 for DOD agencies, and subparagraphs (c)(1) and (c)(2) of the Commercial Computer Software Restricted Rights clause at FAR 52.227-19 for other agencies.
Agilent Technologies, Inc. Santa Rosa Systems Division 1400 Fountaingrove Parkway Santa Rosa, CA 95403-1799, U.S.A.
© Copyright 1992, 1998, 2001 Agilent Technologies, Inc.
ii 87421/22A Operating and Service Manual

Warranty

Certification Agilent Technologies certifies that this product met its published
specifications at the time of shipment from the factory. Agilent Technologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology (NIST,
formerly NBS), to the exte nt allowed by the Institute’s calibration facility, and to the calibration facilities of other International Standards Organization members.
Warranty This Agilent Technologies system product is warranted against defects in
materials and workmanship for a period corresponding to the individual warranty periods of its component products. Instruments are warranted for a period of one year . During the w arranty period, Agile nt T echnol ogies will, at its option, either repair or replace products that prove to be defective.
W ar ranty ser vice for products i nstalle d b y Agilent an d certain other p roducts
designated by Agilentwill be performed at Buyer’s facility at no charge within Agilent service travel areas. Outside Agilent service travel areas, warranty service will be performed at Buyer’s facility only upon HP’s prior agreement and Buyer shall pay HP’s round trip travel expenses. In all other areas, products must be returned to a service facility designated by HP.
For products returned to Agilent for wa rranty servi ce, Buyer shall prepay shipping char ges to Agilent and Agilent s hall pay shipping char ges to return the product to Buyer. However , Buyer shall pay all shipping charges, duties, and taxes for products returned to Agilent from another country.
Agilent warrants that its software and firmware designated by Agilent for use with an instrument will execute its programming instructions when properly installed on that instrument. Agilent does not warrant that the operation of the instr ument, or softw are, or fir mware will be un interrupted or error free.
LIMITATION OF WARRANTY. The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer, Buyer-supplied software or interfacing, unauthorized modification or misuse, operation outside of the environmental specifications for the product, or improper site preparation or maintenance.
NO OTHER WARRANTY IS EXPRESSED OR IMPLIED. AGILENT SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OR MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
EXCLUSIVE REMEDIES. THE REMEDIES PROVIDED HEREIN ARE BUYER’S SOLE AND EXCLUSIVE REMEDIES. AGILENT SHALL
87421/22A Operating and Service Manual iii
NOT BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER BASED ON CONTRACT, TORT, OR ANY OTHER LEGAL THEORY.

Assistance Product maintenance agreements and other customer assistance agreements

are available for Agilent Technologies products. For assistan ce, ca ll your local Agi lent Technologies Sales and Service Of f ice
(refer to “Service and Support” on page v).
iv 87421/22A Operating and Service Manual

Service and Support

By internet, phone, or fax, get assistance with all your test and measurement needs.
Online assistance: www.agilent.com/find/assist United States
(tel) 1 800 452 4844
New Zealand
(tel) 0 800 738 378 (fax) (+64) 4 495 8950
Latin America
(tel) (305) 269 7500 (fax) (305) 269 7599
Japan
(tel) (+81) 426 56 7832 (fax) (+81) 426 56 7840
Canada
(tel) 1 877 894 4414 (fax) (905) 282-6495
Australia
(tel) 1 800 629 485 (fax) (+61) 3 9210 59 47
Europe
(tel) (+31) 20 547 2323 (fax) (+31) 20 547 2390
Asia Call Center Numbers
Country Phone Number Fax Number
Singapore 1-800-375-8100 (65) 836-0252 Malaysia 1-800-828-848 1-800-801664 Philippines (632) 8426802
1-800-16510170 (PLDT Subscriber Only)
Thailand (088) 226-008 (outside Bangkok)
(662) 661-3999 (within Bangkok)
Hong Kong 800-930-871 (852) 2506 9233
(632) 8426809 1-800-16510288 (PLDT Subscriber Only)
(66) 1-661-3714
Taiwan 0800-047-866 (886) 2 25456723
People’s Republic of China
India 1-600-11-2929 000-800-650-1101
800-810-0189 (preferred) 10800-650-0021
10800-650-0121
87421/22A Operating and Service Manual v

Safety and Regulatory Information

Review this product and related documentation to familiarize yourself with safety markings and instructions before you operate the instrument. This product has been designed and tested in accordance with international standards.
WARNING The WARNING notice denotes a hazard. It calls attention to a procedure,
practice, or the like, that, if not correctly performed or adhered to, could result in personal injury. Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met.
CAUTION The CAUTION notice denotes a hazard. It calls attention to an operating
procedure, practice , or t he like, which, if not correctly performed or adhered to, could result in damage to the product or loss of important data. Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met.
Instrument Markings
When you see this symbol on your instrument, you should refer to the instrument’s instruction manual for important information.
!
This symbol indicates hazardous voltages.
The laser radiation symbol is marked on products that have a laser output.
This symbol indicates that the instrument requires alternating current (ac) input.
The CE mark is a registered trademark of the European Community. If it is accompanied by a year, it indicates the year the design was proven.
The CSA mark is a registered trademark of the Canadian Standards Association.
1SM1-A This text indicates that the instrument is an Industrial Scientific and Medical Group 1
Class A product (CISPER 11, Clause 4). This symbol indicates that the power line switch is ON.
This symbol indicates that the power line switch is OFF or in STANDBY position.
vi 87421/22A Operating and Service Manual
Safety and Regulatory Information
Safety Earth Ground
This is a Safety Class I product (provided with a protective earthing terminal). An uninterrup ti ble saf et y ear th gr ound must be pr o vided from the main power source to the product input wiring terminals, pow er cord, or supplied power cord set. Whenever it is likely that the protection has been impaired, the product must be made inoperative and secured against any unintended operation.
Befor e Applying Power Verif y that the pro duct is configured to match the available main power
source as d escribed in the input power c onfiguration instructions in this manual. If this product is to be powered by autotransformer, make sure the common terminal is connected to the neutral (grounded) side of the ac power supply.
87421/22A Operating and Service Manual vii
Safety and Regulatory Information
viii 87421/22A Operating and Service Manual

Declaration of Conformity

Declaration of Conformity
87421/22A Operating and Service Manual ix

87421/22A Power Supply

The 87421A and 87422A power supplies are universal input, dc switching power supplies designed to provide the bias voltages needed to operate microwave system amplifiers.

87421A Power Supply The 87421A is a 25 watt,

83006A, 83017A, and 87415A microwave system amplifiers.
The power suppl y includes an A C po wer cor d with protect i ve grou nd for
connection to 90-240 Vac.
Also included is a 2 meter cable wi th a 3-pin conne ctor on one end and a
D-subminiature connector (83006-60005) on the other end for direct connection to the microwave system amplifiers.
The 87421A may also be used to provide bias voltages for the 83440C high speed lightwave converter. Using the 83440-60009 lightwave converter power supply adapter, the 87421A becomes a compact convenient power supply for use with the lightwave converter.
12 V dc power supply designed to power the
±
Figure 1 87421A Power Supply Diagram
87421/22A Operating and Service Manual 1
87421/22A Power Supply

87422A Power Supply The 87422A is a 90 watt,

83020A microwa v e system power amplifie r. One additional ±12 V dc output is provided to power a preamplifier such as the 83006A or 83017A.
The power supply includes an AC power cord with protective ground for connection to 90-240 Vac and two 2 meter cables:
one cable (83006-60005) with a 3-pin connector on one end and a
D-subminiature connector on the other end
one cable (87422-60001) for direct connection to the 83020A amplifier
15 V power supply designed to power the
±
Figure 2 87422A Power Supply Diagram
2 87421/22A Operating and Service Manual

Specifications

Table 1 Specifications
Product Specifications
Model Number 87421A 87422A
Specifications
Output voltage/current + 12 V at 2 A
- 12 V at 200 mA
Output power 25 W 90 W Line regulation 0.1% 0.1% Load regulation
(20% to full load) Output ripple 25 mV RMS max 25 mV RMS max Output noise 2% peak to peak max 2% peak to peak max Overvoltage limit protected Yes Yes Short circuit protection Current limited for overload and
AC input voltage 90-250 Vac, 50/60 Hz 90-240 Vac, 50/60 Hz Fuse 1 A, slow blow T 3.15 A
2.0% 1.0%
short circuit protection. Normal operation returns upon removal of overload.
General Specifications
+ 15 V at 4.0 A
-15V at 20 mA +12V at 2 A
-12V at 200mA
Current limited for overload and short circuit protection. Normal operation returns upon removal of overload.
Weight 0.9 kg (2.0 lb) 2.1 kg (4.6 lb) Shipping Weight 1.8 kg (4.0 lb) 3.2 kg (7.0 lb)
Environment Specifications
0
Operating temperature 0 Storage temperature -40
C to +550 C full load 0 0 C to +550 C full load
0
C to +700 C-40
Product Safety
CAN/CSA 234 !EC 1010 UL 1950
0
C to +700 C
CAN/CSA 234 !EC 1010 UL 1950
×
87421/22A Operating and Service Manual 3

Operating and Service

Operating and Service
Operating Instructions To operate the power supplies, connect the power supplies output to the
amplifier dc input with the cable provided. The power supplies include a power cord with protective ground for connection to 90-240 Vac.
Mounting holes are provided as shown in the diagrams. The power supplies may be mounted in any orientation with user supplied hardware.
NOTE
To ensure continued compliance to product safety and EMC
specifications, connect the power supplies to an amplifier only with the cable provided.
Do not attempt to modify or extend the dc output cable. Contact your
local Agilent Technol ogies Sales a nd Service office for help with s pecial applications requiring longer cables.
Fuse Replacement The power supplies have a fuse located next to the IEC appliance inlet. If it
is necessary to replace the fuse, disconnect the power supply from both AC power and the amplifier. Using a slotted screw driver, open the fuse cover and replace the fuse.
Service Information The power supplies contain no user serviceable parts (with the exception of
the fuse). If service is required, contact your nearest Agilent Technologies Service Center. Refer to “Service and Support” on pagev.
Available Instruments and Accessories
83006A microwave system amplifier 0.01-26.5 GHz
83017A microwave system amplifier 0.5-26.5 GHz
83018A microwave system amplifier 2-26.5 GHz
83020A microwave system power amplifier 2-26.5 GHz
87415A microwave system amplifier 2-8 GHz
83440C high speed lightwave converter dc-20 GHz, 1000-1600 nm
83440-60009 lightwave converter power supply adapter
487421/22A Operating and Service Manual