81000BI Bare Fiber Connectivity Set for 81630B, 81634B Sensors
(not to be used for 81635A and 81636B)
81004BH 10 Bare Fiber Holder for fibers <400µm diameter
81009BH 10 Bare Fiber Holder for fibers 400 - 900µm diameter
(bare fiber)
Note: All sensor inputs are non-contact and accept both straight and angled connectors.
Page 8 of 16
Optical Heads (5 mm sensor)
OPTIONAL
For advanced accuracy
see
„Special Calibration“
options C01/02 and
C85/86
Accessories
81624CE 4 m extension cable
81624DD additional D-shape quick change adapter
81624RM Half-rack Mount Kit for 2 Heads
81625RM Rack Mount Kit for 4 Heads
Connector Adapters
(threaded)
81000BT Bare Fiber Connectivity Set
(Threaded)
81000FA FC/PC/APC
81000KA SC/PC/APC
81000VA ST
81003LA LC
81000PA E-2000
Interface Module
Optical Heads for:
Connectorized Fiber,
Bare Fiber and
Open beam NA ≤ 0.3
Connector
Adapters
(threaded).
Interface Modules
81618A Single Head Interface Module
81619A Dual Head Interface Module
Optical Heads
81623B Ge +10dBm to –80 dBm (spec for 750 – 1800nm)
81624B InGaAs +10dBm to –90 dBm
81626B InGaAs +27dBm to –70 dBm
D-Shaped Adapter 81624DD
(supplied with head)
Filter Holder
[1]
Filter / Holder
81010BL Lens for 1300/1550 nm,
single mode
81050BL Lens for 1300/1550 nm, multi
mode
Connector Adapters
(with integral D-Shape)
81624DD D-Shaped adapter not
required
81000BC Bare Fiber Connectivity
Set (D-shaped)
81001FA FC
81001KA SC
81001LA LC
81001MA MU
81001PA E-2000
81001ZA BLANK Adapter
Integral
D-Shaped Adapters
Page 9 of 16
High Power Optical Head (with integrating sphere)
OPTIONAL
Accessories
81624CE 4 m extension cable
Interface Module
High Power
Optical Head for:
Connectorized Fiber,
Bare Fiber and
Open beam NA ≤ 0.3
81628B InGaAs
+40 dBm to –60 dBm
Connector Adapters
(threaded).
Interface Modules
81618A Single Head Interface Module
81619A Dual Head Interface Module
Connector Adapters
(threaded)
81000BT Bare Fiber Connectivity Set
(Threaded)
81000FA FC/PC/APC
81000KA SC/PC/APC
81000VA ST
81003LA LC
81000PA E-2000
Page 10 of 16
Return Loss modules
OPTIONAL
For Laser Safety information see page 14
Return Loss
Module
Angled
contact interfaces
Connector Interface
for angled contacts
81610A Return Loss Module (without internal source)
81613A Return Loss Module (1310/1550 nm internal source)
Connector Interfaces for angled connectors
2 ea required for 81610A.
1 ea required for 81613A,
(2 ea required if using external source input).
81000FI FC/APC key width 2.2 mm
81000NI FC/APC key width 2.0 mm
81000HI E-2000/APC
81000KI SC/APC
81000SI DIN 47256/APC
81000VI ST/APC
81000LI LC/APC
81000MI MU/APC
Reference Cable
81610CC Reference Cable – for calibration of all 8161xA Return Loss Modules
Connectors - DIN 47256/APC (connects to module) and FC/PC (supplied with calibrated return
loss values to open air)
An 81000SI connector interface is required to connect this cable to the module.
This cable is used for calibration only, not for measurements.
Caution: Do not make physical contact to the FC/PC connector and do not attach another
connector to it. This could change the calibrated (open) return loss values.
Page 11 of 16
81610CC
DIN 47256/APC
Standard patch
cord
81000UM 81000BR
FC/PC
or
Optical Attenuator modules
OPTIONAL
Optical Attenuators with
Straight Contact Connectors
81576A (dual slot)
Optical Attenuator with
Power Control for high power
Connector Interfaces
(input and output):
2 ea required
81000FI FC/PC key width 2.2 mm
81000HI E-2000 PC
81000KI SC/PC
81000LI LC/PC
81000MI MU/PC
81000SI DIN 47256/PC
81000VI ST/PC
Optical
Attenuator
Straight Contact
Connectors
Connector
Interface for
straight
connectors
Optical
Attenuator
Angled Contact
Connectors
Connector
Interface for
angled
connectors
Optical Attenuators with
Angled Contact Connectors
81571A (single slot)
Optical Attenuator for high power
81577A (dual slot)
Optical Attenuator with
Power Control for high power
Connector Interfaces
(input and output):
2 ea required
81000FI FC/APC key width 2.2 mm
81000NI FC/APC key width 2.0 mm
81000HI E-2000 APC
81000KI SC/APC
81000LI LC/APC
81000MI MU/APC
81000SI DIN 47256/APC
81000VI ST/APC
Page 12 of 16
Optical Switch modules
OPTIONAL
Optical Switches (multi-mode)
with Straight Contact Connectors
81591B #062 (single slot)
Optical switch 1x2 for
multi-mode applications
81594B #062 (single slot)
Optical switch 2x2 for
multi-mode applications
81595B #062 (single slot)
Optical switch 1x4 for
multi-mode applications
Multi-mode
Optical Switch
with
Straight Contact
FC/PC
Connectors
Single-mode
Optical Switch
with
Angled Contact
FC/APC – R
Connectors
(key width
2.0mm)
Optical Switches (single-mode)
with Angled Contact Connectors
81591B #009 (single slot)
Optical switch 1x2 for
single-mode applications
81594B #009 (single slot)
Optical switch 2x2 for
single-mode applications
81595B #009 (single slot)
Optical switch 1x4 for
single-mode applications
Page 13 of 16
Laser Safety Information
81613A 1310/1550nm RL
81650A 1310 nm FP
81651A 1550 nm FP
81654A 1310/1550 nm
The laser sources listed directly above are classified as
Class 1 according to IEC 60825-1 (2001).
All laser sources comply with 21 CFR 1040.10 except for
deviations pursuant to Laser Notice No. 50,
dated 2001-July-26.
CLASS 1 LASER PRODUCT
(IEC 60 825-1 / 2001)
81655A #E01 850 nm FP
81655A 1310 nm FP
81656A 1550 nm FP
81657A 1310/1550 nm FP
81662A C- and L-Band DFB
81663A C-band DFB
81600B #200 1440 nm – 1640 nm All-band TLS
81600B #140 1370 nm – 1495 nm low SSE TLS
81600B #150 1450 nm – 1590 nm low SSE TLS
81600B #160 1495 nm – 1640 nm low SSE TLS
81600B #130 1260 nm – 1375 nm low SSE TLS
81600B #132 1260 nm – 1375 nm high power TLS
81600B #142 1370 nm – 1495 nm high power TLS
81940A 1520 nm – 1630 nm compact TLS
81944A 1525 nm – 1625 nm compact TLS
81949A 1520 nm – 1630 nm compact TLS
81980A 1465 nm – 1575 nm compact TLS
81989A 1465 nm – 1575 nm compact TLS
All laser sources specified directly above are classified
as Class 1M according to IEC 60825-1 (2001).
All laser sources comply with 21 CFR 1040.10
except for deviations pursuant to Laser Notice No. 50,
dated 2001-July-26.
Page 14 of 16
This page intentionally left blank
Page 15 of 16
Agilent Technologies’ Test and Measurement Support, Services, and Assistance
Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and
measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent
products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five
years beyond the production life of the product. Two concepts underlie Agilent's overall support policy: "Our Promise" and "Your Advantage."
Our Promise
Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new
equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test
engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for
the use of specified capabilities, at no extra cost upon request. Many self-help tools are available.
Your Advantage
Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your
unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, outof-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering
services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your
Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products.
By Internet, phone, or fax, get assistance with all your test & measurement needs