Agilent 8163A Data Sheet

9
Agilent Solution
Optical Component Test
Agilent 8163A + 81636B
Fast Power Measurement
Save costs in optical component test and speed-up time to market with very fast and highly accurate power measurement
Fast and accurate
Low PDL: +/- 0.015 DB
100.000 data points
Dynamic range: >55 dB per range
Extra slot available for additional measurements
Offer limited until 30th of April, 2002
Order Now!
Best Price-
Performance Ratio
for Optical Power
Measurement
Fast Power Measurement Solution
Agilent 8163A + 81636B
Take advantage of Agilent’s Power Meter Solution with unpreceden­ted performance and measurement power to test optical components.
8163A Lightwave Multimeter
The Agilent 8163A Lightwave Multimeter System is a mainframe that allows plug-in of a variety of modules, like the 81636B. It is flexible to be used in different test set-ups, requiring:
single or dual channel power meters
fixed of tunable laser sources
loss test applications
Return loss and insertion loss applications
The Agilent 8163A + 81636B offer high performance and at the same time reduce cost of test substantially to strengthen your competitive positioning.
Test Configuration
81636B
Fast Powermeter
The Agilent Fast Powermeters feature high-speed data acquisition and a high dynamic range.
Alignment and adjustment tasks performed manually or by auto­mation are typical applications for using the Agilent 81636B Fast Power Powermeter.
Fast Power Measurement Solution
Best Price-Performance for Optical Power Measurement
Display Graphical display 190 x 300 points visible, monochrome
Display resolution 0.0001dB/dBm, 0.01pW to 10pW (depending on power range),
up to 6 1/2 digits (user definable)
Compatibility The Agilent 8163A mainframe supports all modules from the 8153A
and 8163A Lightwave Multimeter series.
Data acquisition
Memory 4000 measurement results/channel (remote 12000) Selectable data averaging time depending on sensor module Selectable data total acquisition time 1s to 23:59h
Trigger True synchronous on all channels
Environmental
Storage temperature –40ºC to +70ºC Operating temperature 0ºC to +45ºC Humidity <95% rH from 0ºC to 45ºC
These products are designed for pollution degree 2. The maximum operation altitude is 2000m
Power AC 100 — 240V ± 10%, 50/60Hz ±5%, 120VA max.
Dimensions (Height x Weight x Length) 88mm x 213mm x 380mm (3.5” x 8.4” x 15”)
Weight net 4.200kg (9,3lbs), shipping 6.5kg (14.5lbs)
GPIB capability All modes and parameters accessible via GP-IB interface
GPIB capability function codes SCPI Standard
Interfaces Parallel port (Centronics)
Serial port (RS232)
Number of modules 2 Modules
Agilent 8163A Specifications
Agilent 81636B Specifications
Sensor element InGaAs Wavelength range 1250 to 1640 nm Power range +10 to –80 dBm Applicable fiber type Standard SM and MM up to
62.5 µm core size, NA <
0.24
Uncertainty (accuracy) at +3% reference conditions (1260 nm to 1630 nm)
Total uncertainty ±5% to ±20pW
(1260 nm to 1630 nm)
Relative uncertainty
due to polarization typ. ± 0.015 dB spectral ripple typ. ± 0.015 dB
(due to interference)
Linearity (power) CW +10 to –60 dBm
at 23ºC ±5ºC (1280 nm to 1630 nm) at operating temp. range <±0.02 dB ±20nW
<±0.06 dB ±20nW
Return loss >40 dB Noise (peak to peak) <20 pW Averaging time (minimal) 25µs Dynamic Range at manual range mode
at +10dBm range typ. >55dB at ±0dBm range typ. >55dB at –10dBm range typ. >52dB at –20dBm range typ. >45dB
Linearity (power) CW +10 to –60 dBm at manual range mode (1280 nm to 1630 nm)
at +10dBm range <±0.02 dB ±50nW at ±0dBm range <±0.02 dB ±5nW at –10dBm range <±0.02 dB ±1nW at –20dBm range <±0.02 dB ±500pW
Choose your connector type
81000AI Diamond HMS10
81000FI FC/PC/SPC
81000FI NEC D4
81000JI SMA
81000KI SC
81000PI E-2000
81000SI DIN 47256/4108 81000VI ST 81000LI LC 81000FB Bare Fiber Adapter 81000FI FC/PC/SPC 81000NI FC/APC
Order Information
Agilent 8163A + 81636B
Single channel powermeter solution consisting of Agilent 8163A Mainframe and Agilent 81636B Powersensor
[
Agilent Technologies
Passive Component Test Optical Amplifier Test Bit Error Ratio Test
Mux/DeMux/V-Mux
TFF Test
FBG Filter Test
Connector Test
Switch Test
TFF Align-/Adjustment
Fiber to AWG Alignment/
AWG Chip Test
Couper/Splitter/Combiner
Isolator/Circulator
Variable Optical Attenuator
Gain Flattening Filter
EDFA
Raman Amplifiers
SOA
Rx/Tx
Line Card
System Test
Tunable Laser
••• •••••••
81480A, 81640A, 81680A
Tunable Laser
••••
81642A, 81682A
Compact Tunable Laser
•• ••••
81649A, 81689A/B
Distributed Feedback (DFB) Laser
•••
81662A, 81663A
Fabry-Perot Laser
••••••
Power Meter
••••••• •••• •••
8163xB
Optical Heads
••• •
Return Loss Modules
••••••••••
81610A, 81611A, 81612A 81613A, 81614A
Attenuator
••
81560A, 81561A, 81566A, 81567A
Polarization Controller
••• ••••••
8169A
Polarization Controller
•• •••
11896A
Digital Communications Analyzer
(DCA)
Bit Error Ratio Tester (BERT)
SONET/SDH Tester
••
Optical Spectrum Analyzer (OSA)
•••
Mainframes 8163A/B
•••
8164A/B
••• •••••••••••
8166A/B
••
Photonic Foundation Library
••• •••••••
Optical Component Test
Test Innovations That Improve Your Bottom Line
For related literature please visit http//: www.agilent.com/cm/rdmfg/oct/literature/octselection.pdf
By internet, phone, or fax, get assistance with all your test & measurement needs
For further information, please visit
www.agilent.com/comms/comp-test
Phone or Fax United States: Europe: Latin America: New Zealand: Asia Pacific: Canada: Japan: Australia: (tel) 1 800 452 4844 (tel) (31 20) 547 2323 (tel) (305) 269 7500 (tel) 0 800 738 378 (tel) (852) 3197 7777 (tel) 1 877 894 4414 (tel) (81) 426 56 7832 (tel) 1 800 629 485
(fax) (31 20) 547 2390 (fax) (305) 269 7599 (fax) 64 4 495 8950 (fax) (852) 2506 9284 (fax) (905) 282-6495 (fax) (81) 426 56 7840 (fax) (61 3) 9210 5947
Product specifications and descriptions in this document subject to change without notice.
Printed February 1, 2002 Copyright © 2001 Agilent Technologies 5988-4030EN
Loading...