Agilent 81101A Data Sheet

Agilent 81100 Family of Pulse/Pattern Generators
The Agilent Technologies 81101A pulse generator belongs to the 81100 family. All members have the same programming and user interfaces that are compatible with the well­established Agilent 8110A. Migration is therefore easy and cost effective.
Signals for testing digital designs and components
The 81101A generates all of the standard pulses needed to test current logic technologies (CMOS, TTL, ECL, etc.);
• Variable pulse parameters.
• Can be triggered in syncrony.
Glitch-free timing changes
Now you can sweep your timing values without the danger of spurious pulses or dropouts that could cause measure­ment errors (applies to continuous mode, values < 100 ms, consecutive values between 0.5 and twice the previous value).
Reliable measurements
The 81101A provides clean, accurate pulses with excellent repeatability, thus contributing to measurement integrity.
Easy to use
Features such as the clear graphical display, autoset, help, store/recall, preset TTL/ECL levels, selectable units (such as current/voltage, width/ duty-cycle), and load compensation ensure a high level of convenience.
Smooth integration into automated test systems
The 81101A can be integrated easily into all phases of test system develop­ment, such as planning, rack integra­tion, and test program generation. Test programs are 100% upwardly compatible to the 81104A and 81110A, ensuring that growth with future needs is just as easy as exchanging the instruments themselves. This results in low integration costs, in addition to low costs of ownership, through proven hardware reliability.
Agilent 81101A
50 MHz One-Channel Pulse Generator
Data Sheet
Key Features
• Agilent 8110A user interface.
• Variable transitions.
• Up to10 Vpp (20 Vpp) into 50 Ω.
• 3.5 digits timing resolution, best case 5 ps.
• 0.01% frequency accuracy.
• Fully SCPI programmable.
• Broad range of trigger and syn­chronization capabilities.
• Dropout and glitch free change of any timing parameters.
• 8.9 cm height, full rack width.
• Graphical display.
2
Burst Count: 2 to 65536 (single or double pulses).
Delay: Delay, phase, or % of period. Double pulse delay: Double pulse and
delay are mutually exclusive. Duty cycle: Set between 0.1% and 95% (subject to width limits; 99.9% with overprogramming).
Transition times: These can be entered as leading/trailing edge or % of width. Leading and trailing edges are inde­pendent within one of the following overlapping segments (1:20 ratio): 5 ns - 20 ns, 10 ns - 200 ns, 100 ns - 2 µs, 1µs - 20 µs, 10 µs - 200 µs, 100 µ s - 2 ms, 1 ms - 20 ms, 10 ms - 200 ms.
Output timing fidelity: Period, delay, and width are continuously variable with­out any output glitches or dropouts. Repeatability: Is typically four times better than accuracy.
Mainframe Agilent 81101A
Frequency range 1 mHz to 50 MHz
Timing resolution 3.5 digits, 5 ps best case
RMS jitter (period, width, delay)
With PLL ± 0.001% ± 15 ps With VCO
[1]
± 0.01% ± 15 ps
Period range 20 ns to 999.5 s Accuracy with PLL ± 0.01% (± 5%)
[1]
Width range 10.0 ns to (period - 10.0 ns) Accuracy ± 5% ± 250 ps
[2]
Additional variable delay range 0 ns to (period - 20 ns) Accuracy
[3]
± 5% ± 1 ns
Double pulse delay range (width + 10.0 ns) to
(period - width - 10.0 ns)
Accuracy ± 5% ± 500 ps
Transition time range (10/90) 5 ns to 200 ms variable Accuracy ± 10 % ± 200 ps Linearity 3% typ. for transitions > 100 ns
[1] If the startable oscillator (VCO) is used (PLL not active). [2] Changing of amplitude may add 0.5 ns. [3] Width accuracy specification is valid up to 5.5 Vpp amplitude. Above this amplitude, the width will typically
increase up to 300ps.
Specifications
Specifications describe the instrument’s warranted performance. Non­warranted values are described as typical. All specifications apply after a 30-minute warm-up phase with 50 source/load resistance and separate channels. All specifications are valid from 0°C to 55°C ambient temperature.
Timing Characteristics
Measured at 50% amplitude at fastest transitions, in continuous mode, and 50 source impedance.
3
Level parameters:
Can be entered as voltage or current, as high and low level, or as offset and amplitude.
Load compensation:
The actual load value can be entered (for loads 50 ) to display actual output values.
On/off:
Relays connect/disconnect output (HiZ).
Normal/complement:
Selectable
Limit:
Programmable high and low levels can be limited to protect the device­under-test.
Trigger Modes
Continuous:
Continuous pulses, double pulses, or bursts (single or double pulses).
External triggered:
Each active input transition (rising, falling or both) generates a single or double pulse or burst.
External gated:
The active input level (high or low) enables pulses, double pulses, or bursts. The last single/double pulse or burst is always completed.
External width:
The pulse shape can be recovered, while period and width of an external input signal are maintained. Levels and transitions can be set.
Manual:
Simulates an external input signal.
Internal triggered:
Internal PLL replaces an external trigger source.
Inputs and Outputs
Clock input/PLL reference and external input: One input (BNC connector at
rear panel) is used for clock input or alternatively for the PLL. PLL Reference: The internal PLL is locked to an external 5 MHz or 10 MHz reference frequency. Clock input: The output period is deter­mined by the signal at CLK input Ext. input: Used for trigger, gate, or external width.
Input impedance: 50 /10 kselectable Threshold: -10 V to +10 V Max. input voltage: ±15 Vpp Sensitivity: 300 mVpp typical Input transitions: <100 ns Frequency: Dc to 50 MHz Minimum pulsewidth: 10 ns
Level/Pulse Performance Characteristics
Level specifications are valid after a 30 ns typical settling time.
Agilent 81101A
Amplitude 50 into 50 100 mVpp to 10.0 Vpp
1 kinto 50 200 mVpp to 20.0 Vpp
Level window 50 Ω into 50 -10.0 V to +10.0 V
1 kinto 50 -20.0 V to +20.0 V
Accuracy 50 Ω into 50 ± (3% + 75 mV)
1 kinto 50 ± (3% + 150 mV)
[1]
Resolution 50 Ω into 50 10 mV
1 kinto 50 20 mV
Output connectors BNC single-ended
Source Impedance Selectable 50 or 1 k
Accuracy Typ. ± 1%
Max. external voltage ± 24 V
Short circuit current ±400 mA max.
Base line noise 10 mV RMS typ.
Overshoot/preshoot/ringing ± 5% of amplitude ± 20 mV
[1] In ±19 V level window.
Strobe output and trigger output
Strobe: Marks the beginning of each
burst Trigger format: One pulse per period with 50% duty cycle typical
External mode: 9 ns typical Level: TTL or ECL selectable Output impedance: 50 typical Max. external voltage: -2 V/+7 V Transition times: 1.0 ns typical for TTL,
600 ps typical for ECL
User Interface
Overprogramming: Values can be
entered, exceeding the specified range, to fully exploit the hardware limits. Setting check: Warning messages indicate potentially conf licting param­eters due to inaccuracy. Error mes­sages indicate conf licting parameters. Help key: Displays a context sensitive message. Autoset key: Resolves all timing conflicts. Non-volatile memory: The current setting is saved on power-down. Up to nine user settings and one fixed default setting are stored in the instrument. Memory card: 99 settings can be stored on a 1 MB PCMCIA card (MS-DOS).
Remote Control: Operates according to IEEE standard 488.2, 1987 and SCPI
1992.0
Function Code: SH1,AH1,T6,L4,SR1, RL1,PP0,DC1,DT1,C0 Programming times: All checks and display off
Typical delay times Agilent 81101A
Instrument mode From To Typical value
External width EXT. INPUT STROBE/TRIGGER OUT 8.5 ns
OUTPUT 1/OUTPUT 2 22.5 ns
All other modes EXT. INPUT/CLK INPUT STROBE/TRIGGER OUT 12.0 ns
OUTPUT 1/OUTPUT 2 29 ns
STROBE/TRIGGER OUT OUTPUT 1/OUTPUT 2 17 ns
ASCII command Typical exec. time
One parameter or mode 30 ms typical
Recall setting 250 ms typical
4
5
General
Operating temperature: 0°C to +55°C Storage temperature: -40°C to +70°C Humidity: 95% r.h. up to 40°C ambient
temperature EMC: Conforms to EN50082-1, EN 55011, Class B
Noise emission: 5.7 bel typical Battery: Lithium CR2477-N Safety: IEC1010, CSA1010 Power requirements:
100-240 Volts ac, ± 10%, 50-60 Hz 100-120 Volts ac, ± 10%, 400 Hz
Power consumption: 300 VA max. Max. dimensions (H x W x D):
89 mm x 426 mm x 521 mm
Weight: 9.2 kg net, 13.8 kg shipping Recalibration period: One year
recommended Warranty: Three years standard
6
Ordering Information
Each Agilent 81101A includes just one output channel (in comparison to the other models of the 81100A family).
The English Quick Start Guide (81101-91010) and Reference Guide (81101-91011) are supplied with each instrument for all configurations. A memory card is not included.
81101A 50 MHz one-channel Pulse Generator, 10V
Accessories Opt UN2 Rear Panel Connectors (instead of front panel) Opt 1CP Rack Mount and Handle Kit (5063-9219) Opt 1CN Handle Kit (5063-9226) Opt 1CM Rack Mount Kit (5063-9212) Opt 1CR Rack Slide Kit (1494-0059) Opt UFJ 1 MB SRAM Memory Card (0950-3380) 15104A Pulse Adder/Splitter
Quick Start Guide language options Opt ABF French Guide (81101-91210) Opt ABJ Japanese Guide (81101-91510) Opt AB0 Taiwan Chinese Guide (81101-91610) Opt AB1 Korean Guide (81101-91710) Opt AB2 Chinese Guide (81101-91810)
Additional documentation options Opt 0BW Service Manual (81101-91021) 81101-91031 Service Documentation (Component Level)
Support Options Opt 1BP MIL Std. 45662A Calibration with Test Data Opt UK6 Commercial cal. certificate Opt W32 3 Year Customer Return Calibration Coverage Opt W34 3 Year MIL Calibration Service Opt W50 5 Year Customer Return Repair Coverage Opt W52 5 Year Customer Return Calibration Coverage Opt W54 5 Year Customer Return Calibration Coverage
Agilent Technologies’ Test and Measurement Support, Services, and Assistance
Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measure­ment capabilities you paid for and obtain the support you need. Our extensive sup­port resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the produc­tion life of the product. Two concepts underlie Agilent’s overall support policy: “Our Promise” and “Your Advantage.”
Our Promise
“Our Promise” means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product informa­tion, including realistic performance spec­ifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabil­ities, at no extra cost upon request. Many self-help tools are available.
Your Advantage
“Your Advantage” means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve prob­lems efficiently and gain a competitive edge by contracting with us for calibration, extra­cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project man­agement, and other professional services. Experienced Agilent engineers and techni­cians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measure­ment accuracy for the life of those products.
Get assistance with all your test and measurement needs at:
www.agilent.com/find/assist
Product specifications and descriptions in this document subject to change without notice.
Copyright © 1998, 2000 Agilent Technologies Printed in U.S.A. 5/00 5967-6274E
Related Literature Pub. Number
Agilent Family of Pulse/Pattern Generators, brochure 5980-0489E
Agilent 81100 Family of Pulse/Pattern Generators, 5980-1215E
data sheet
Agilent 8110A Pulse/Pattern Generator, data sheet 5980-1212E
Agilent 8114A 100V/2A Programmable Pulse Generator, 5980-1213E
data sheet
Agilent 8133A 3 GHz Pulse Generator, data sheet 5980-1214E
Radar Distance Test to Airbourne Planes, product note 5968-5843E
The Dual Clock Gbit Chip Test, product note 5968-5844E
Magneto-Optical Disk Drive Research, product note 5968-5845E
Simulation of Jittering Synchronization Signals 5968-5846E for Video Interfaces, product note
Electronic Functional Test of the Consolidated Automated 5968-5998E Support System (CASS), case study