37
Supplemental Characteristics
for all model numbers
dc Floating Voltage: Output terminals can
be floated up to ±240 Vdc from chassis
ground
Remote Sensing: Up to half the rated
output voltage can be dropped in each
load lead. The drop in the load leads
subtracts from the voltage available for
the load.
Output Programming Response Time:
The rise and fall time (10/90% and
90/10%) of the output voltage is less
than 15 ms. The output voltage change
settles within 1 LSB (0.025% x rated
voltage) of final value in less than 60 ms.
Down Programming: An active down
programmer sinks approximately
20% of the rated output current
Modulation: (Analog programming of
output voltage and current)
Input signal: 0 to –5 V
Input impedance: 10 k Ohm nominal
ac Input: (ac input frequency 47 to 63 Hz)
Voltage 100 Vac 120 Vac 220 V ac 240 Vac
Current 12 A 10 A 5.7 A 5.3 A
Input Power: 1,380 VA, 1,100 W at full load;
120 W at no load
Regulatory Compliance: Listed to UL 1244;
certified to CSA556B; conforms to
IEC 61010-1.
Size: 425.5 mm W x 132.6 mm H x
497.8 mm D (16.75 in x 5.22 in x
19.6 in) See page 101 for more details
Weight: Net, 25 kg (54 lb); shipping,
28 kg (61 lb)
Warranty Period:One year
Single-Output: 500 W (Continued)
Specifications
(at 0˚to 55˚C unless
otherwise specified)
Power Products Catalog 2002-2003
For more detailed specifications see the product manual at
www.agilent.com/find/power
Agilent Performance dc Power Supplies speed and accuracy for test optimization
6551A-J01 6551A-J03 6553A-J04 6553A-J17
Special Order Special Order Special Order Special Order
Option Option Option Option
Number of outputs 111 1
GPIB No No No No
Output ratings
Output voltage 10 V 6 V 40 V 30 V
Output current (40° C) 50 A 60 A 12.5 A 17.5 A
Maximum current (50° C/55° C)
45 A/42.5 A 54 A/51 A 11.25 A/10.6 A 15.75 A/14.87 A
Programming accuracy
at 25°C ±5°C
Voltage 0.06% + 6 mV 5 mV 17.5 mV 15 mV
Current 0.15% + 60 mA 75 mA 13 mA 16 mA
Ripple and noise
from 20 Hz to 20 MHz
Voltage rms 300 µV 300 µV 1.6 mV 400 µV
peak-peak 3 mV 3 mV 5 mV 4 mV
Current rms 25 mA 30 mA 5 mA 6 mA
Load regulation
Voltage 1 mV 1 mV 3.5 mV 3 mV
Current 2 mA 6.5 mA 1 mA 0.5 mA
Line regulation
Voltage 0.5 mV 0.5 mV 1 mV 1 mV
Current 2 mA 2 mA 0.75 mA 0.75 mA
Transient response time Less than 100 µs for the output voltage to recover to its previous level
(within 0.1% of the voltage rating of the supply or 20 mV, whichever is greater)
following any step change in load current of up to 50% of rated current
Supplemental Characteristics (Non-warranted characteristics determined by design and
useful in applying the product)
Average resolution
Voltage 2.5 mV 2 mV 12 mV 10 mV
Current 15 mA 18 mA 4 mA 5 mA
OVP 16 mV 12 mV 65 mV 54 mV
OVP accuracy 200 mV 160 mV 750 mV 700 mV