A User’s Guide to Agilent 3458A Front Panel Operation
Short Cuts
Reading/Menu Display
Function/Range Keys
• Alphanumeric Reading, Units, and Functions
• Command Menu
• Status Annunciators
• MORE INFO (additional information viewable with )
A 5-Minute Tutorial of Front Panel Operation
Example 1: Making a measurement with any function after turning
on the Agilent 3458A. The ACV function serves as a typical example
of the immediate execute keys found in the Function/Range key
group. Connect the appropriate signal to the input terminals and
press the keys shown.
Command Key Group Key Sequence
ACV
ACV
ACV Function/R ange
(Any other function key in the Function/Range Key Group acts
similarly; the Agilent 3458A changes function, automatically
ranges, and begins measurements.)
RESET Function/Range
(RESET returns the Agilent 3458A to the powered-on state.)
Example 2: Making a precision Vdc measurement on the 10 V range.
Command Key Group Key Sequence
RESET Function/Range
DCV Function/Range
10 V Range Function/Range
(The and keys are
displayed: in this case, XX.XXXXX V DC (X is any number).
Leading zeros are always displayed for easy range identification.)
NPLC 100 Menu
(Measurement will take about 3 seconds.)
NDIG 8 Function/Range
(Sets the display to 8 1/2 digits.)
pressed until the desired range is
Numeric/User
Menu
Numeric/User
ACVACV
(blue)
(blue)
(blue)(blue)
Reset
(blue)
(blue)
(blue)(blue)
Reset
DCV
DCV
DCVDCV
or
NPLC
NPLC
NPLCNPLC
1 0 0
(blue)
(blue)
(blue)(blue)
N
Enter
8
Enter
Menu Keys
• Immediate Execute Function Keys
• MAnual Range and Menu
•Display Window
• GPIB Bus Address
The shifted Menu Keys allow alphabetic access to all
Agilent 3458A commands and command parameters. The commands and command parameters are scrolled from A to Z by using
the Menu Scroll keys ( and ) found in the Function/Range
keys. Command parameters are accessed by using the Display/
Window keys and , also found in the Function/Range
keys, after the command is located.
Example 3: Making a very precise Vac measurement using the Synchronous ACV measurement function. (At power-on, the Agilent
3458A is set to the generally more useful Analog ACV measurement
function if you select ACV, but you should use Synchronous ACV for
very precise measurements of periodic waveforms.)
Command Key Group Key Sequence
RESET Function/Range
ACV Function/Range
SETACV SYNC Function/Range
Menu S
Function/Range
Numeric/User
(The MORE INFO annunciator should be illuminated. The MORE
INFO annunciator indicates that some part of the measurement
configuration is in a non-standard state. To view this information
press . Your display should show SETACV SYNC. Now press
• Commonly Used Commands
• Shifted Alphabetic Entry Points
into Command Menu
(blue)
(blue)
(blue)(blue)
Reset
ACV
ACV
ACVACV
(blue)
(blue)
(blue)(blue)
Enter
again; the display is returned to the measurement state.)
(blue)
RES .002 Function/Range
Menu R
Function/Range
Numeric/User
(The RES command sets the % resolution of the measurement. A
function change causes RES to default to RES .01 (0.01%) with
reading rate of 1 per 3 s.)
LFILTER ON Function/Range
Menu L
Function/Range
Numeric/User
(Suggested for inputs with frequencies below 50kHz.)
(blue)
(blue)(blue)
. 0 0 2
(blue)
(blue)
(blue)(blue)
Enter
Enter
Numeric/User Keys
• 10-Key Pad for Numeric Entry
• Deep RECALL buffer of Executed Commands
• MENU type selection
• 10 Battery Backed Up User Definable Keys F0-F9
Auto-Calibration (ACAL)
The Agilent 3458A Auto-Calibration (ACAL) function removes measurement
errors caused by component temperature and time drift. For maximum
accuracy, ACAL should be performed every 24 hours. For example, additional Vdc volts gain errors due to temperature changes are reduced from
°C to 0.15 ppm/°C (over 6:1) using ACAL. In ACV volts, additional
1 ppm/
gain error due to temperature changes are reduced from 30 ppm/
than 1 ppm/
°C (over 30:1) using ACAL. The time to perform a complete
ACAL is about 12 minutes. ACAL ACV takes about 1 minute, ACAL DCV
takes about 2 minutes, and ACAL OHM takes about 9 minutes. For monitoring temperature changes, the Agilent 3458A provides the TEMP? command
(found in the command Menu) to measure the internal instrument temperature. Refer to the User’s Guide for more details. ACAL keystroke sequence.
Auto
Auto
AutoAuto
Cal
Cal
CalCal
, 3 4 5 8
Enter
Configuration for Highly Accurate Measurements
with the Agilent 3458A
(You should perform an ACAL every 24 hours for the appropriate function after the
Agilent 3458A has been powered-on and in a stable temperature environment for a minimum
of four hours.)
Function Comment Key Sequence
____________________________DCV____________________________
RESET Power-on state (VDC)
NPLC 200
Integration Time
(1)
NDIG 8 8 1/2 Digits
____________________________ACV____________________________
RESET Power-on state
ACV Function Vac
SETACV SYNC Synchronous AC
RES .002 Max AC Reading Res.
LFILTER ON
Internal LP Filter
(2)
__________________________OHMS____________________________
RESET Power-on state
OHMF Function Four-Wire Ohms
OCOMP ON
DELAY 1
NPLC 200
1. Longer integration times reduce measurement noise and increase measurement resolution.
2. Recommended for frequencies less than 50kHz.
3. OCOMP ON turns on the offset compensation feature of the Agilent 3458A. OCOMP ON minimizes the effect of any thermally generated offset voltage from creating errors in resistance
measurements.
4. Adds 1 s settling delay to reduce effects of dielectric absorption errors of cabling and the
resistor under test
For R <= 100 kOhms
Adds 1 s delay
(4)
Integration Time
(blue)
(blue)
(blue)(blue)
NPLC
NPLC 2 0 0
NPLCNPLC
(blue)
(blue)
(blue)(blue)
(blue)
(blue)
(blue)(blue)
ACV
ACV
ACVACV
(blue)
(blue)
(blue)(blue)
(blue)
(blue)
(blue)(blue)
(blue)
(blue)
(blue)(blue)
(blue)
(blue)
(blue)(blue)
(blue)
(blue)
(blue)(blue)
Offset
Offset
OffsetOffset
(3)
Comp
Comp
CompComp
(blue)
(blue)
(blue)(blue)
NPLC
NPLC 2 0 0
NPLCNPLC
Reset
Enter
8
N
Reset
S
. 0 0 2
R
L
Reset
OHMF
Enter
9
C
1
°C to less
Enter
Enter
Enter
Enter
Enter
Enter
Store and Recall Instrument Setups
Store and Recall can significantly reduce the number of keystrokes necessary for a complex configuration. Simply pressing , pressing a Numeric
Key X (0-127) and pressing , stores the state of the Agilent 3458A as a
state to recall by pressing X. Shipped with the Agilent 3458A is a small
Recall
Recall
RecallRecall
State
State
StateState
Enter
Store
Store
StoreSt ore
State
State
StateSta te
plastic overlay that fits on key 5 to document your User Key and Stored
State definitions. Use Example 3 and perform the following:
Command Key Group Key Sequence
Store
Store
SSTATE 1 Menu
Numeric/User
StoreSt ore
State
State
StateSta te
Enter
1
(Stores the Agilent 3458A’s state in stored state 1.)
(blue)
RESET Function/Range
(blue)
(blue)(blue)
Reset
(RESET returns the Agilent 3458A to the powered-on state.)
Recall
Recall
RSTATE 1 Menu
Numeric/User
RecallRecall
State
State
StateState
Enter
1
(Returns the Agilent 3458A to stored state 1.)
User Definable Keys
In addition to the State Store and Recall commands, you can also define any
of the User keys, F0-F9, in the Numeric/User Key Group to be any string of
commands.
Let's use Example 3 one more time to show how this feature works.
Command Key Sequence
DEFKEY DEFAULT
(blue)
(blue)
(blue)(blue)
Def Key
(Clears all previously defined User Definable keys.)
DEFKEY F0,
"
0
(Ready to accept commands.)
FUNC ACV
(blue)
(blue)
(blue)(blue)
E (three times)
(The delimiter used to separate commands is " ; ".
The delimiter used to separate parameters is " , ".)
SETACV SYNC
RES .002
LFILTER ON
DEFKEY F1,
MATH NULL
"
(blue)
(blue) (blue)
(blue)(blue)
S
(blue)
(blue)
(blue)(blue)
R
(blue)
(blue)
(blue)(blue)
L
1
(blue)
(blue)
(blue)(blue)
L (four times)
(MATH NULL displays the difference between the first and subsequent measurements.)
Now Use It!
Enter
(blue)
(blue)
(blue)(blue)
f0
Enter
(blue)
(blue)
(blue)(blue)
f1
(Note the MATH annunciator is turned on.)
Command Recall Buffer Operation
The command recall buffer recalls previously entered commands. If you
have performed the sequence in the User Definable Keys you can expect to
have the results listed below.
Enter
(blue)
(blue)
(blue)
(blue)(blue)
Enter
(blue)(blue)
;
(four times)
. 0 0 2
(eight times)
;
(blue)
(blue)
(blue)(blue)
;
Enter
Command Key Group Key Sequence
RECALL Function/Range
Numeric/User Recall
(MATH NULL should appear in the Display.)
The MENU Command
To access the commands alphabetically, you use the Menu Keys. As the
Agilent 3458A is shipped, only the most commonly used commands are
available in this "SHORT" menu. To access all the commands, you have to use
the Menu Key with the "FULL' parameter.
(blue)
(blue)
(blue)(blue)
Command Key Group Key Sequence
MENU FULL Function/Range
Numeric/User Menu
Function/Range
Numeric/User
(blue)
(blue)
(blue)(blue)
Enter
*03458-90007*
03458-90007