Agilent 16700A Product Overview

Page 1
HP 16600A and 16700A Series Logic Analysis System Mainframes
Product Overview
The Advantage of Insight
Debugging today’s digital systems is tougher than ever. Increased prod­uct requirements, complex software, and innovative hardware technolo­gies make it difficult to meet your time-to-market goals.
Solutions for Digital System Debug
As a digital designer, you need test equipment that quickly provides reliable insight into your toughest problems. That is why HP has com­bined logic analysis, emulation and software tools into one integrated system — to give you a complete view of your prototype, from signals to source code.
HP has a solution to help you completely outfit your team while providing budgetary flexibility. With HP’s scalable systems, you won’t waste money on features you'll never use. And you won’t be faced with scrapping recently bought tools just because you changed micro­processors.
Page 2
Key Features Overview
2
Figure 2. Acquire state data at 333 MHz and timing data at up to 2 GHz through the same connection.
Figure 3. Configure your HP 16700A Series system for your spe­cific application with modular mainframes.
Features Benefits
___________________________________________________________________________________________________________________________
Scalable System
• State/timing analyzers • Select the optimum combination of performance, features, and price that you need
• Oscilloscopes for your specific application today, with the flexibility to add to your system as your
• High-speed timing measurement needs change.
• Pattern generator • View system activity from signals to source code.
• Emulation module
___________________________________________________________________________________________________________________________
Timing Zoom Technology • Simultaneously acquire data at up to 2 GHz timing and 333 MHz state through the same connection.
___________________________________________________________________________________________________________________________
VisiTrigger Technology • Use graphical views and sentence-like structure to help you define a trace event .
___________________________________________________________________________________________________________________________
Processor and Bus Support • Get control over your microprocessor’s internal and external data.
___________________________________________________________________________________________________________________________
Post-Processing Analysis Tools • Rapidly consolidate large amounts of data into displays that provide insight into your
___________________________________________________________________________________________________________________________
Setup Assistant • Quickly configure the logic analysis system for your target microprocessor. (See pg 5).
___________________________________________________________________________________________________________________________
Tabbed Interface • Groups like tasks together so you can quickly find and complete the task you want to perform.
___________________________________________________________________________________________________________________________
Multi-Windowed View of • View your cross-domain measurements, time-correlated on the same screen. (See pg 5) Target System Activity • Debug faster because you can view system activity at a glance.
___________________________________________________________________________________________________________________________
Global Markers • Track a symptom in one domain (timing) to its cause in another domain (analog).
___________________________________________________________________________________________________________________________
• Room to grow
Timing Zoom is available across all channels, all the time. (See pg 9)
• Select trigger functions as individual trigger conditions or as building blocks to easily customize a trigger for your specific task.
• Quickly and reliably connect to the device under test. (See pg 10-11)
system’s behavior. (See pg 10)
• Spend your time solving problems, not setting up a measurement.
Page 3
Key Features Overview
3
(cont.)
Features Benefits
___________________________________________________________________________________________________________________________
Resizable Windows and Data Views • Magnify your view or zoom in on a boxed area of interest.
_____________________________________________________________________________________________________________________________
Web-Enabled System • Directly access the instrument’s web page from your web browser. (See pgs. 6 & 7)
___________________________________________________________________________________________________________________________
Direct Link to Microsoft®Excel via • Automatically move your data from the logic analyzer into Microsoft Excel with just a HP BenchLink XL 16700 click of the mouse. (See pg 7)
___________________________________________________________________________________________________________________________
Direct Links to Industry • Debuggers provide visibility into software execution for systems running software written Standard Debuggers and in C and C++ as well as active microprocessor execution control (run control). (See pg. 11) High-Level Language Tools • Import symbol files created by your language tools. Symbols allow you to set up trigger
___________________________________________________________________________________________________________________________
Direct Links to EDA Tools • Use captured logic analysis waveforms to generate simulation test vectors.
___________________________________________________________________________________________________________________________
Transfer Data for Offline • Fast binary (compressed binary) from the FileOut tool provides highest performance transfer rate. Analysis – Data Export • ASCII format provides same format as listing display, including inverse-assembled data.
___________________________________________________________________________________________________________________________
Transparent File System Access • Access, transfer, and archive files.
___________________________________________________________________________________________________________________________
Documentation Capability • Save graphics in standard TIFF, PCX, and EPS formats.
___________________________________________________________________________________________________________________________
Remote Programming with • Perform pass/fail analysis, stimulus response tests, data acquisition for offline analysis, and Microsoft’s COM Using system verification and characterization tests. Microsoft Visual Basic or • Powerful-yet-efficient command set focuses on your programming tasks, resulting in a shorter Visual C++ learning curve while maintaining necessary functionality.
___________________________________________________________________________________________________________________________
Network Security • Protect your networked assets and comply with your company’s security requirements with
___________________________________________________________________________________________________________________________
• Resize waveforms and data or quickly change colors to highlight areas of interest.
• Remotely check the instrument’s measurement status without disturbing the acquisition.
• Remotely access, monitor and control your logic analysis system.
• Use Microsoft Excel’s powerful functions to post-process captured trace data to get the insight you need.
conditions and review waveform and state listings in easily recognized terms that relate directly to the names used for signals on your target and the functions and variables in your code.
• Easily find problems by comparing captured waveforms with simulated waveforms.
• Stay synchronized with your source code by mapping shared directories and file systems from your Windows 95/98/NT-based PC directly onto the logic analyzer and vice versa.
• Move data files to and from the logic analyzer for archive or use elsewhere.
• Print screen shots and trace listings to a local or networked printer.
• Save your lab notes and trace data in the same file by entering relevant information in the Comments tab of the display.
(See pg. 14 for more information)
individual user logins that provide system integrity.
Page 4
4
Module Choices
State/Timing
HP offers a wide variety of state/timing modules to help you match your debug tools to your specific measurement needs. These modules include high-speed acquisition to capture glitches, wide channel counts to monitor all of the signals from a high-end processor system, and deep memory to capture elusive system crashes. See page 9.
Oscilloscope
Identify signal integrity issues and characterize signals quickly with automatic measurements of rise time, voltage, pulse width, and frequency.
High-Speed Timing
Precisely characterize setup/hold times over a wide channel count. Capture data over many clock cycles while retaining the highest multi­channel accuracy.
Pattern Generation
Use stimulus to substitute for missing system components or provide a stimulus-response test environment.
Key Features
Modularity is the key to the HP 16600A and 16700A Series logic analysis systems’ long term value. You purchase only the capability you need now, then expand as your needs evolve. All modules are tightly integrated to provide time-correlated, cross-domain measurements.
Figure 4. The power-up screen lets you identify and access the measurement capa­bility available in your logic analysis system.
Emulation
The emulation module connects to the debug port (BDM or JTAG) on your target. You have full access to processor execution control features of the module through the built-in emulation control interface or a third-party debugger.
Table 1. HP 16600A and 16700A Series Supported Measurement Modules
________________________________________________________________________________________________________________________
Use the target control port to activate your target’s reset or inter­rupt lines, making it convenient to control the target remotely.
Port-in/Port-out BNC connectors allow you to trigger or arm exter­nal devices or receive signals that can be used to arm acquisition modules within the logic analysis system.
Measurement HP Model Number Description Module Category
________________________________________________________________________________________________________________________ State and Timing 16717A
________________________________________________________________________________________________________________________ Oscilloscopes 16534A 2 channel, 500 MHz bandwidth
________________________________________________________________________________________________________________________ HIgh-Speed Timing 16517A/16518A 4 GHz timing, 1 GHz synchronous state, 64K memory depth (master/expander)
________________________________________________________________________________________________________________________ Pattern Generator 16522A 200 M vector/second pattern generator
________________________________________________________________________________________________________________________ Emulation E5901A Processor-specific device provides code download, register/memory modification,
________________________________________________________________________________________________________________________
1
Currently only supported in the HP 16700A Series.
1
_____________________________________________________________________________________________
1
16716A
_____________________________________________________________________________________________
1
16715A
_____________________________________________________________________________________________ 16710A/16711A/16712A 100 MHz state, 500 MHz timing, 8K/32K/128K deep memory depth
_____________________________________________________________________________________________ 16557D 140 MHz state, 500 MHz timing, 2/4 M memory depth
_____________________________________________________________________________________________ 16556A/D 100 MHz state, 400 MHz timing, 2/4 M memory depth
_____________________________________________________________________________________________ 16555A/D 110 MHz state, 500 MHz timing, 2/4 M memory depth
_____________________________________________________________________________________________ 16554A 100 MHz state, 250 MHz timing, 512 K/1M memory depth
_____________________________________________________________________________________________ 16550A 100 MHz state, 500 MHz timing, 4/8K memory depth
_____________________________________________________________________________________________ 16533A 2 channel, 250 MHz bandwidth
333 MHz state, 667 MHz timing, 2 GHz Timing Zoom, 2/4 M memory depth 167 MHz state, 667 MHz timing, 2 GHz Timing Zoom, 512K/1M memory depth 167 MHz state, 667 MHz timing, 2/4 M memory depth
and processor control (including break, run, reset, single step)
Page 5
Key Features (Cont.)
5
See the Big Picture of Your Prototype System’s Behavior
The large display with multiple, resizable windows on the HP 16600A and 16700A allows you to see at a glance more of your target system’s operation. A built-in, flat-panel display in the HP 16702A fits in envi­ronments with limited space. Color lets you highlight critical information so you can find it quickly.
Use one tool to examine target oper­ation from different perspectives. Multiple time-correlated views of data let you confirm both signal integrity and software execution flow. This is invaluable in solving cross-domain problems.
Figure 7. You can quickly isolate the root cause of system problems by examin­ing target operation across a wide analysis domain, from signals to source code.
Demo Center provides simple demos of the most commonly-used features.
Help enables you to access the online User’s Guide and measurement examples. The Help system includes full search and hypertext link capabilities.
Setup Assistant is a guided menu system that helps you config­ure the logic analysis system for your target microprocessor or bus. Online informa­tion guides you through the setup. (See Figure 5)
System Setup Is As Easy As a Mouse Click
Figure 5. Setup Assistant gets you up and run­ning quickly.
Figure 6. Icons in the power-up screen give you quick access to common tasks
System Admin allows you to set up the instrument on your network, establish printers, set up user accounts for security, or update software quickly.
Page 6
Key Features (cont.)
6
When your logic analysis system is connected to your company’s Intranet, you can directly access its web page from your web browser, whether you're in the office, at home, or at another site. Working from multiple locations has never been this convenient.
Expanding Possibilities with Network Connectivity
View and analyze the data any­where, anyplace, anytime
Web-enabled instrumentation gives you the freedom to access the sys­tem—anywhere, anytime. Have you ever needed to check on a measure­ment's status while you were in a remote location? Now you can!
With a Web Enabled Logic Analysis System You Can...
...access the logic analysis system’s web page from your browser by typing in the logic analy­sis system’s URL (hostname or IP address).
...access HP's web site for the latest online manuals and technical information.
...quickly check instrument status to determine if the analyzer is available for use.
...remotely check current measurement status to find out if the system has triggered.
...access the analyzer's user interface directly from within your browser, giving you full con­trol of all analyzer functions.
...install HP Benchlink XL 16700 to seamlessly transfer data from the analyzer to the PC.
Figure 8. Your logic analyzer is its own web site. From the Home Page you can per­form multiple remote functions.
Page 7
HP BenchLink XL 16700 Moves Your Data Automatically into Microsoft Excel for Advanced Offline Analysis
Use the HP BenchLink XL 16700 tool bar to connect to an HP logic analysis system. Select from the available labels and specify the destination cell location in Excel.
Import data from the current acquisition or data previously saved to a file via the File Out tool.
Use Microsoft Excel's powerful functions to post-process captured trace data for the insight you need.
Figure 9. From your web browser, you have full remote control of all logic analyzer functions.
Figure 10. Transfer data into Excel with just a click of the mouse.
Key Features (cont.)
7
Remote Control Helps to Improve the Efficiency of Your Debug Efforts.
Check up on long duration measurements to determine if you need to change a trigger specification or save captured data to a file.
Simultaneously share your measurement results with other team members in different locations. Work concurrently to make real­time decisions and solve problems.
Remotely access the target control port to reset the target, then set up a different mea­surement and start another acquisition.
Page 8
8
Table 2. Top-Level Comparison of the HP 16700A and 16600A Series Mainframes
Mainframe–HP Model 16700A 16702A 16600A/16601A/16602A/16603A
________________________________________
Slots for measurement modules 5 (10 total with HP 16701A 1
expansion frame)
_______________________________________________________________________________ Built in state/timing channels None None 204, 136, 102, 68
_______________________________________________________________________________ Number of emulation 2 (4 total with HP 16701A 1 module slots expansion frame)
_______________________________________________________________________________ HP 16701A expansion Yes Yes No frame support
_______________________________________________________________________________ Built-in display No 800
Selecting a System that’s Right for You
The following pages describe the components available to configure a system that meets your digital debug needs. For a list of all sup­ported measurement modules for the HP 16600A and 16700A Series mainframes, refer to page 4.
Your mainframe and measurement module selection depends on:
•Desired mainframe form factor
•Availability of extra slots for future measurement capabilities
•Number of state/timing analysis channels needed
•Additional measurement/analysis capabilities: oscilloscope, pattern generator, high-speed timing, emu­lation, microprocessor and bus support, and post-processing analysis software
•Accessories
•Service and support
•Budget
Available Mainframes
The HP 16700A Series platform is a modular system that can change as your needs grow. You decide which state and timing analysis module(s) you want, then you add other mea­surement modules to meet your debug needs.
The HP 16600A Series logic analysis system offers built-in state and timing capabilities from 68 to 204 channels. These channel configura­tions are fixed. However, each frame contains one expansion slot for addi­tional measurement capability, such as an oscilloscope, pattern generator, or analysis module.
_______________________________________________________________________________ External monitor supported 1280 × 1024 std.,1600 × 1200 opt. 003, or remote via web browser
_______________________________________________________________________________
× 600, 10.3” No
or X-windows
Table 3. Built-in Logic Analysis Capability of the HP 16600A Series Analyzers
HP Models 16600A 16601A 16602A 16603A
_______________________________________
Maximum state clock 100 MHz 100 MHz 100 MHz 100 MHz
_______________________________________________________________________________ Maximum timing sampling 125/250 MHz 125/250 MHz 125/250 MHz 125/250 MHz
rate (full/half channels)
_______________________________________________________________________________ Memory depth (full/half 64/128 K
channels)
_______________________________________________________________________________ Channels supported 204 136 102 68
_______________________________________________________________________________ Supports context store Yes Yes Yes Yes
_______________________________________________________________________________ Setup/hold time 0/4.5 ns to 4.5/0 ns adjustable in 500 ps increments
_______________________________________________________________________________
1
Increased memory depth in half channel timing mode only.
With Context Store, Capture Infrequent Problems Every Time They Occur
1
64/128 K
1
64/128 K
Hardware engineers can use con­text store when searching for the cause of events that occur infre­quently or randomly in time, but
1
64/128 K
that seem to be correlated to specif-
The HP 16600A Series mainframes and the HP 16710A, 16711A, and
ic conditions, such as interrupts or writes to certain address ranges.
16712A measurement modules support advanced state and timing acquisition technology, including context store.
When you are debugging software or trying to determine if the cause of a problem is in the hardware or software, context store makes it
Using context store, you can store the events that occur before and after a specific trigger condition in a time window centered approxi-
easy to identify the cause of memo­ry and pointer corruption problems without having to sort through large amounts of trace data.
mately around an event. Trace memory is filled only with data that is specific to the measurement you want to make.
1
Page 9
9
Table 4. New State and Timing Modules
NEW HP Models 16715A 16716A 16717A
________________________________________
Maximum state clock 167 MHz 167 MHz 333 MHz
_______________________________________________________________________________ Maximum timing 333/667 MHz 333/667 MHz 333/667 MHz sample rate 2 GHz Timing Zoom 2 GHz Timing Zoom (full/half channels)
_______________________________________________________________________________ Memory depth 2/4 M
1
512 K/1 M
1
2/4 M
1
full/half channels)
_______________________________________________________________________________ Channels/module 68 68 68
_______________________________________________________________________________ Maximum channels on 340 340 340 a single time base
_______________________________________________________________________________ Maximum channels in 680 680 680 an HP 16700 Series system with an HP 16701A
_______________________________________________________________________________ Setup/hold time 4.5/–2.0 ns to 4.5/–2.0 ns to 4.5/–2.0 ns to
–2.0/4.5 ns in –2.0/4.5 ns in –2.0/4.5 ns in 100 ps increments 2100 ps increments 2100 ps increments
2
_______________________________________________________________________________
Available State and Timing Analysis Measurement Modules
HP offers logic analysis modules that vary in channel count, acquisition speed, and memory depth so that you can select the capability that meets your needs as well as your budget.
The Speed and Triggering You Need for Tomorrow, Available Today
HP Timing Zoom Technology (HP 16716A and 16717A) Enables You To:
Simultaneously acquire up to
2 GHz timing and 333 MHz state data across all channels, all the time, through the same connection
•Vary the Timing Zoom sample rate from 250 MHz to 2 GHz
•Capture 16K memory depth
•Vary the placement of Timing Zoom data around the trigger point
•Efficiently characterize hardware with 500 ps resolution
HP VisiTrigger Technology (HP 16715A, 16716A and 16717A) Lets You:
Use graphical views and sentence-
like structure to help you define a trace event.
•Select trigger functions as individ­ual trigger conditions or as build­ing blocks to easily customize a trigger for your specific task.
•Set global counters to count events such as the number of times a function executes, or the number of accesses to an I/O port.
•Set, clear or evaluate flags by any module in the frame. Flags allow you to set up a trigger that is dependent on activity from more than one bus in the system.
•Specify four-way arbitrary IF/THEN/ELSE branching.
Selecting a System that’s Right for You (cont.)
HP Model 16550A 16557D 16517A, 16710A,
1-4 Modules 5 Modules 16518A 16711A,
16712A
________________________________________
Maximum state clock 100 MHz 140 MHz 100 MHz 1 GHz 100 MHz
________________________________________________________________________________ Maximum timing 500 MHz 500 MHz 4 GHz 500 MHz sampling rate
________________________________________________________________________________ Memory depth 4/8 K 2/4 M
1
64/128 K
1
8/16K1,
(full/half channels) 32/64K1,
128/256K
1
________________________________________________________________________________ Channels/module 102 68 16 102
________________________________________________________________________________ Maximum channels 204 272 304 80 204 (on a single time base and trigger)
________________________________________________________________________________ Maximum channels 1020 680 160 1020 in an HP 16700 series system (w/ HP 16701A expansion mainframe)
________________________________________________________________________________
Table 5. State and Timing Modules for the HP 16600A and 16700A Series Mainframes
Setup/hold time 3.5/0 ns to 3.0/0 ns to –0.5/3.5 ns 350 ps/ 350 ps 4.5/0 ns to 0/4.5 ns
________________________________________________________________________________
1
Increased memory depth in half channel timing mode only.
2
Minimum setup/hold time specified for single edge, single clock acquisition. Multi-clock, multi-edge add 0.5 ns.
3
Minimum setup/hold time specified for single edge, single clock acquisition. Single clock,
multi-edge setup/hold window is 5.0 ns. Multi-clock, multi-edge setup hold window is 5.5 ns.
0/3.5 ns, adjustable in adjustable in 500 ps adjustable in 500 ps increments increments 500 ps increments
3
Page 10
10
Selecting a System that’s Right for You (cont.)
Post-Processing Tool Sets Provide Rapid Insight Into Your Toughest Debug Problems
When you want to really under­stand what your target is doing and why, you need to be able to view acquisition results in a format that quickly guides you to problem identification.
Each tool set described in Table 6 is an optional post-processing soft­ware package for the HP 16600A and 16700A Series logic analysis systems. The tool sets offer you a variety of views of the same real­time data to give you insight into your specific application.
Speed Problem Solving with Off-the-Shelf Solutions for Many Common Microprocessors
Table 6. Optional Software Tool Sets for the HP 16600A and 16700A Series Mainframes.
Application Product Name HP Model
_______________________________________________________________________________ Debug your real-time code at the source level. Source Correlation B4620B Correlate the logic analyzer trace with the Tool Set high-level source code that produced it. Set up the logic analyzer trace by simply pointing and clicking on a line of source code.
_______________________________________________________________________________ Customize your trace for greater insight. Tool Development Kit B4605B Create custom tools using the C programming language. Custom tools can analyze captured data and present it in a form that makes sense to you. Analysis systems do not require the Tool Development Kit to run generated tools.
_______________________________________________________________________________ Optimize your system’s performance. System Performance B4600B Profile your system’s performance to identify Analysis Tool Set system bottlenecks and to identify areas needing optimization.
_______________________________________________________________________________ Solve your serial communication problems. Serial Analysis B4601B Convert serial bit streams to parallel format for Tool Set easy viewing and analysis. Supports serial data with or without an external clock reference and protocols that use bit stuffing to maintain clock synchronization. Works at speeds up to 1 GHz.
_______________________________________________________________________________
Number
To help you design and debug your microprocessor-based target systems, HP offers different micro­processor specific products that let you get control and visibility over your microprocessor’s internal and external data.
An analysis probe allows you to quickly connect an HP logic analyzer to your target system. The analysis probe provides non-intrusive capture and disassembly of microprocessor and bus activity.
Analysis probes are available for over 200 microprocessors and microcontrollers. Bus probes allow probing of popular bus architec­tures such as PCI, AGP, USB, VXI, SCSI, and many others.
Flexible physical probing schemes give quick and reliable connections to almost any device on your prototype.
Figure 11. HP analysis probes (formerly known as preprocessors) make it easy to connect a logic analyzer to your target system.
Page 11
11
Figure 12. Emulation Control Interface
On-Chip Emulation Tools Make Fixing Bugs Easier
For specific microprocessor families that feature on-chip emu­lation, you can add an emulation module to your system to connect the on-board debugging resources of the microprocessor to the logic analysis system.
The microprocessor’s BDM or JTAG technology provides control over processor operation even if there is no software monitor on the target system. This feature is particularly helpful during the development of your target system’s boot code.
Emulation Control Interface
The emulation control interface is accessed from the power up screen of the HP 16600A or 16700A Series system. The interface is included standard for those microprocessors supported with the HP E5901A emulation module.
Designed for hardware engineers, this generic graphical user interface provides the following features:
•Control over processor execution: run/break/reset/step
•Register display/modification
•Memory display/modification in various formats including disassem­bly for code visualization. Memory modification or memory bloc fill can be done to check processor memory access or to reinitialize memory areas.
•Multiple breakpoint configuration: hardware, software, and processor internal breakpoint registers.
•Code download to the target
•Command scripts to reproduce test sequences.
•The ability to trigger a measure­ment module on a processor break or receive a trigger from the logic analysis system’s measurement modules.
Integrated Debugger Support
When the hardware turn-on phase is completed, the same HP emula­tion module can be connected to high-level debuggers for C or C++ software development.
You can achieve the functionality of a full-featured emulator by using a third-party debugger to drive the installed HP emulation module. This gives you active and complete microprocessor execution control (run control).
Selecting a System that’s Right for You (cont.)
Page 12
584.2 (23.0)
469.9 (18.5)
190.5  (7.5)
482.6 (19.0)
254 (10.0)
243.8 (9.6)
774.7 (30.5)
866.1 (34.1)
116.8 (4.6)
594.4 (23.4)
652.8 (25.7)
772.2 (30.4)
Accessories and Support
12
Figure 13. HP 1184A testmobile cart
Weight
_____________________________________ HP 1184A 48.0 kg (106.0 lb) 59.0 kg (130.0 lb)
_____________________________________
Max Net Max. Shipping
HP 1184A Testmobile
The HP 1184A testmobile gives you a convenient means of organizing your HP logic analysis system mainframes and accessories.
The testmobile includes the following:
•Drawer for accessories (probes, cables, power cords)
•Keyboard tray with adjustable tilt and height
•Mouse extension on keyboard tray accommodates either right or left hand operation
•Locking casters for safety on uneven surfaces
•Strap provided to stabilize the monitor
•Load limits:
Top tray: 68.2 kg (150.0 lb.) Lower tray: 68.2 kg (150.0 lb.) Total: 136.4 kg (300.0 lb.)
HP Support and Services
HP’s family of support services com­plements your logic analysis system to provide a complete solution. HP’s expertise allows you to concentrate on your particular design projects and applications, rather than your debug tools, result­ing in increased productivity.
HP can provide consulting to assist in making specific measurements, applying debug techniques, and understanding the issues related to specific processors. On-site assis­tance can be provided for initial turn­on of your target system. Contact your local HP representative for more information on HP consulting services available in your area.
HP training courses include extensive hands-on and are designed to pay off immediately in real-world situations. HP training can be delivered through scheduled classes, on-site classes, or one-on-one con­sulting. For training offered in your geography and language, consult the HP test and measurement education web site:
http://www.hp.com/go/tmeducation
Figure 14. HP 1184A testmobile cart dimensions. Dimensions: mm (inches).
HP on-line support professionals can help you better use digital system debug tools to maximize your investment and minimize your debug time. Operational verification and standard measurement assistance can be provided via vari­ous methods including phone, fax, e-mail, or web.
The standard warranty for your system may be enhanced via a return-to-HP warranty extension, a conversion to on-site warranty, installation services, and calibration services.
Page 13
HP 16600A and 16700A Series
13
Technical Information
System Software
All features and functionality described in this document are available with system software version A.01.40.00
Mass Storage
____________________
Hard Disk Drive 4 GB formatted disk drive
______________________________________
Floppy Disk Drive
Capacity 1.44 MB formatted Media 3.5 inch floppy Formats MS-D0S (Read, write, for­______________________________________
Internal System RAM
____________________
Standard 64 MB
______________________________________
Option 003 (Must 160 MB total be ordered at time of frame purchase)
______________________________________
Supported Monitor Resolutions
____________________
Standard 640 x 480 through 1280 x 1024
______________________________________
Option 003 Adds support for up to (Must be ordered 1600 x 1200 at time of frame purchase)
______________________________________
LAN, IEEE 802.3
____________________
Physical 10BaseT (Ethertwist): RJ-45 Connectors 10Base2 (Thinlan): BNC
______________________________________
Protocols TCP/IP Supported NFS
______________________________________
X-Window X Window system version Support 11, release 6, as a client and
______________________________________
Web Server
____________________
Supported from Measurement status check, Instrument Web remote display, installation Page of PC application software,
______________________________________
PC Pentium®(family) PC Requirements (200 MHz, 32 MB RAM) run-
______________________________________
Supported Web Internet Explorer 4.0 or Browsers (on higher, Netscape 4.0 or Your PC or higher Workstation)
______________________________________
mat), LIF (Read only)
(The HP 16702A has a built-in 800 x 600, 10.3” (26.2mm) diagonal monitor.)
CIFS (Windows® 95/98/NT) FTP NTP PCNFS
server
link to HP’s Test and Measurement site
ning Windows 95, Windows 98, or Windows NT 4.0 w/service pack 3 or higher
HP BenchLink XL 16700 Support
______________________________________
Installation of Directly from instrument web PC Application page Software
______________________________________
Microsoft Version 7.0 or higher Excel 97 Excel limits maximum trace
______________________________________
Available Data Formats
____________________
Fast Binary High performance transfer (Compressed rate. Includes source code Binary Format) to parse data. Available via
______________________________________
Uncompressed Includes utility routines. Binary Available via RPI.
______________________________________ ASCII Provides same format as list-
______________________________________
Intermodule Bus (IMB)
____________________
Time Correlation 2 ns (HP 16700A and Resolution 16702A only)
______________________________________
Port In/Out
____________________
Connectors BNC
______________________________________
Port In
____________________
Levels TTL, ECL, or user defined
______________________________________ Input Resistance 4 K
______________________________________ Input Voltage –6V at –1.5 mA to
______________________________________
Port Out
____________________
Levels 3V TTL compatible into 50
______________________________________ Functions Latched (latch operation is
1
______________________________________
Target Control Port
____________________
Number of signals 8
______________________________________ Levels 3V TTL compatible
______________________________________ Connector 2 rows of 5 pins, 0.1-inch
______________________________________
depth to 64K per sheet.
File Out.
ing display, including inverse-assembled data. Available via RPI and File Out.
+6V at 1.6 mA
module dependent) Pulsed, width from 66 ns to
143 ns
centers
Operating Environment
____________________
Temperature
Instrument 0 °C to 50 °C (32 °F to 122 °F) Disk Media 10 °C to 40 °C (50 °F to 104 °F) Probes/cables O °C to 65 °C (32 °F to 149 °F)
______________________________________ Altitude To 3000m (10,000 ft)
____________________
Humidity 8 to 80% relative humidity at ______________________________________
Printing
____________________
Printer Interface Parallel interface for
______________________________________
Printers PostScript®printers and Supported printers that support the
______________________________________ Graphics Graphics can be printed
______________________________________ 1
User and share level control supported for Windows NT 4.0. Share level control only supported for Windows 95/98.
40 °C (104 °F)
Centronics compatible printers
HP Printer Control Language (PCL)
directly to the printer or to a file. Graphic files can be cre­ated in black-and-white or color TIFF format, PostScript, PCX, or XWD formats.
Page 14
HP Remote Programming
14
Interface (RPI)
HP RPI Overview
_________________________________________
Typical Applications Manufacturing Test
_______________________________________________________________________________
Remote Programming 1. Set up the logic analyzer and save the test configuration. Steps 2. Create a program that remotely enables you to:
_______________________________________________________________________________ Physical Connection Remote programming is done via the LAN connection
_______________________________________________________________________________
Requirements
_________________________________________
HP 16600A and HP RPI is standard with HP16600X-700X system software version 16700A Series A.01.30.00 or higher analysis systems
_______________________________________________________________________________ PC Programming is done via Microsoft® ActiveX/COM automation
_______________________________________________________________________________ Unix Programming is done via procedural commands
_______________________________________________________________________________
Command Set Overview
_________________________________________
System System Configuration Query,
_______________________________________________________________________________
Logic Analysis Load/Save Configuration and Data, Modules Trigger Setup,
_______________________________________________________________________________
Oscilloscope Load/Save Configuration and Data, Modules Trigger Setup,
_______________________________________________________________________________ Pattern Generator Load/Save Configuration and Data,
_______________________________________________________________________________ Emulation Module Reset Processor,
_______________________________________________________________________________ Listing Tool Status,
_______________________________________________________________________________ Compare Tool Execute Compare,
_______________________________________________________________________________ File Out Tool Transfer Data to File
_______________________________________________________________________________
Additional Information
_________________________________________
Instrument Online Help Programming Information in instrument online help
_______________________________________________________________________________ Web Sites Full remote programming documentation (pdf) available on the hard drive.
_______________________________________________________________________________
Data Acquisition for Offline Analysis System Verification and Characterization Pass/Fail Analysis Stimulus Response Tests
• Load a test configuration
• Start the acquisition process
• Check measurement status (verify completion)
• Act on the results of the data acquisition
• Save configuration and captured data
• Export data
• Execute a compare
• Modify the trigger setup or trigger value for the next acquisition
• Access oscilloscope’s automatic measurements
Pentium (family) PC with one of the following:
Windows 95 Windows 98 Windows NT 4.0 w/ Service Pack 3 or higher
Visual Basic or Visual C++ (Version 5.0 or higher)
Load/Save Configuration and Data, Start/Stop Measurement, Current Run Status
Acquisition Data and Parameters
Acquisition Data and Parameters, Query Automatic Measurements
Load ASCII file (vectors), Modify Vector
Run Processor, Break Processor, Single Step
Acquisition Data and Parameters, Transfer Data (includes inverse assembled information)
Set Compare Mask, Query Compare Result
Sample programs are provided.
Page 15
Supplemental Characteristics
15
1.5 pF
HP 16500 Woven Cable Model + Flying Lead
370
7.4 pF
GROUND
100 K
for the HP 16600A, 16601A, 16602A, and 16603A
Probes
_________________________________________
Minimum voltage swing 500 mV peak-to-peak
_______________________________________________________________________________ Threshold range ±6.0 V, adjustable in 50 mV increments
_______________________________________________________________________________
State Analysis
_________________________________________
Setup/hold time
_______________________________________________________________________________ Minimum state clock width 3.5 ns
_______________________________________________________________________________ State clock/qualifiers 6/6 (HP 16600A/16601A/16602A)
_______________________________________________________________________________ Time tag resolution 8 ns
_______________________________________________________________________________
Maximum time count 39 hours between states
_______________________________________________________________________________ Number of machines available 2 state or 1 state/1 timing (HP 16600A, 16601A, 16602A)
_______________________________________________________________________________ Context Store block sizes 16/32/64 states
_______________________________________________________________________________
Timing Analysis
_________________________________________
Sample period accuracy 0.01% of sample period
_______________________________________________________________________________ Channel-to-channel skew 2 ns typical
_______________________________________________________________________________ Time interval accuracy ± (sample period + channel-to-channel skew + 0.01%
_______________________________________________________________________________
1
4.5/0 ns through 0/4.5 ns adjustable in 500 ps increments
4/4 (HP 16603A)
1 state or 1 timing (HP 16603A)
of time interval reading)
Figure 15. Equivalent probe load for the general-purpose lead set.
Triggering
_________________________________________
Maximum sequencer speed 100 MHz
_______________________________________________________________________________ State sequence levels 12
_______________________________________________________________________________ Timing sequence levels 10
_______________________________________________________________________________ Maximum occurrence counter value 1,048,575
_______________________________________________________________________________ Pattern recognizers 10
_______________________________________________________________________________ Range recognizers 2
_______________________________________________________________________________ Range width 32 bits each
_______________________________________________________________________________ Timers 2
_______________________________________________________________________________ Timer value range 400 ns to 500 seconds
_______________________________________________________________________________ 1
Minimum setup/hold time specified for single-edge, single clock acquisition. Single-clock multi­edge setup/hold window is 5 ns. Multi-clock, multi-edge setup/hold window is 5.5 ns. All setup/hold windows are adjustable in 500 ps increments.
Page 16
HP 16600A Series
LAN 10Base-T
SCSI-2 Single Ended
LAN 10Base2
Parallel Port
Monitor
RS-232
Target Control Port
Mouse Keyboard Port IN
Port OUT
One Slot for Measurement Modules
16000A
LOGIC ANALYSIS SYSTEM
POWER
16610A MPC800 EMULATION MODULE
RESET STOP RUN
POD 11 / POD 12 POD 9 / POD 10 POD 7 / POD 8 POD 5 / POD 6
POD 3 / POD 4 POD 1 / POD 2
One Slot for Emulation Module 3.5 inch Floppy Disk Drive
Up to 204 Channels for State and Timing Measurements
482.6 (19.0")
425.7 (16.76")
139.7 (5.50")
487.7 (19.2")
16
Physical Characteristics
Figure 16. HP 16600A Series front panel
Power
_________________
HP 16600A 115/230 V, 48 to 66 Hz, 285 W max HP 16601A 115/230 V, 48 to 66 Hz, 285 W max HP 16602A 115/230 V, 48 to 66 Hz, 285 W max HP 16603A 115/230 V, 48 to 66 Hz, 285 W max
______________________________________
Weight*
_________________
Max Net Max Shipping
HP 16600A 10.0 kg (22.1 lb) 25.2 kg (55.6 lbs) HP 16601A 10.0 kg (22.1 lb) 25.2 kg (55.6 lbs) HP 16602A 10.0 kg (22.1 lb) 25.2 kg (55.6 lbs) HP 16603A 10.0 kg (22.1 lb) 25.2 kg (55.6 lbs)
______________________________________
* Weight of module ordered with mainframes will add 0.9 kg (2.0 lb) per module.
Figure 17. HP 16600A Series rear panel
Figure 18. HP 16600A Series exterior dimensions. Dimensions: mm (inches).
Page 17
HP 16700A Series
425.7 (16.76" )
482.6 (19.0" )
548.64 ( 21.6" )
556.3 ( 21.9" )
234.2 (9.22")
167 02A
LOGIC ANALYSI S SYSTE M
H
3.5 inch Floppy Disk Drive
Built-in LCD Display
Screen Intensity Adjustment
Keypads for Alpha-Numeric Entry
On/Off Power Switch
Parallel Port Monitor RS-232
Five Slots for Measurement Modules
A B C D E
Target Control Port
Port IN Port OUT
Mouse
Keyboard
HP 16701A Expansion Frame Cable Connector
1 2
Two Slots for Emulation  Modules
LAN 10Base-T
SCSI-2 Single Ended
LAN 10Base2
17
Physical Characteristics
Power
_________________
HP 16700A 115/230 V, 48 to 66 Hz, 610 W max HP 16701A 115/230 V, 48 to 66 Hz, 545 W max HP 16702A 115/230 V, 48 to 66 Hz, 610 W max
______________________________________
Weight*
_________________
HP 16700A 12.7 kg (27.0 lb) 34.2 kg (75.4 lbs) HP 16701A 10.4 kg (23.0 lb) 32.0 kg (70.6 lbs) HP 16702A 15.2 kg (32.4 lb) 36.7 kg (80.8 lbs)
______________________________________
* Weight of modules ordered with mainframes will add 0.9 kg (2.0 lb) per module.
Max Net Max Shipping
Figure 19. HP 16702A front panel Figure 20. HP 16700A and 16702A rear panel
Figure 21. HP 16700A, 16701A and 16702A exterior dimensions. Dimensions: mm (inches).
Page 18
18
Ordering Information
Table 8. Mainframe Options
___________________________________________________________________________________
Option # Description HP 16700A or 16702A HP 16701A HP16600A Series
___________________________________________________________________________________
001 Add 17-inch 1280 x 1024 monitor and cable
___________________________________________________________________________________
003 Performance system upgrade — 160 Mbyte
total system RAM, 2 Mbyte total video RAM. (Must order at time of frame purchase)
___________________________________________________________________________________
004 Add CD-ROM Drive
___________________________________________________________________________________
010 Add two sets of 17-channel probe leads
(34 channels)
___________________________________________________________________________________
0B3 Add service guide
___________________________________________________________________________________
1CM Add rack-mount kit
___________________________________________________________________________________
ABJ Japanese Localization
___________________________________________________________________________________
W17 Convert one year return-to-HP warranty to
one year on-site warranty
___________________________________________________________________________________
W30 Extend standard warranty to three year
return-to-HP warranty
___________________________________________________________________________________
W50 Extend standard warranty to five year
return-to-HP warranty
___________________________________________________________________________________
Table 7. Mainframes and Testmobile
___________________________________________________________________________________
Product # Description Includes
___________________________________________________________________________________
HP 16700A
__________________________________________________________________________ • One ten-conductor, flying-lead cable
HP 16702A
__________________________________________________________________________ cables (HP16600A Series only)
HP 16600A Series
___________________________________________________________________________________
HP 16701A Expansion frame with five 1 ft. and 3 ft. interface cables
___________________________________________________________________________________
HP 1184A Testmobile Drawer, keyboard tray, mouse tray,
___________________________________________________________________________________
1
1
1, 2
Modular frame with five measurement module • One DIN keyboard slots and two emulation module slots. • One three-button DIN mouse
Modular frame with built-in 800 X 600 for target control port LCD display, five measurement module • Training kit slots and two emulation module slots. • Two 17-conductor flying-lead probe
Built-in logic analyzer 1 measurement module slot, 1 emulation module slot HP 16600A – 204 channels HP 16601A – 136 channels HP 16602A – 102 channels HP 16603A – 68 channels
measurement module slots and two emulation module slots. Requires HP 16700A or 16702A
strap for stabilizing monitor
RECOMMENDATIONS:
1
For HP 16700A and all 16600A Series mainframes, order a monitor (option 001) and at least one CD-ROM drive (option 004).For the HP 16702A, order at
least one CD-ROM drive (option 004). The CD-ROM drive is necessary to install future system software upgrades.
2
Each HP 16600A Series mainframe includes two sets of 17-channel probe leads (34 channels total). If you require additional pairs of probe leads,
order option 010.
Page 19
19
Publication Title Publication Type HP Publication
Number
_______________________________________________________________________________
Table 9. Related HP Literature
Refer to the documents below for more information on HP logic analysis systems and accessories.
State and Timing Analyzers for HP Logic Analysis Systems
_______________________________________________________________________________
Oscilloscope Modules for HP Logic Analysis Systems
_______________________________________________________________________________
HP 16522A 200 MVector/sec Pattern Generator Module
_______________________________________________________________________________
Processor and Bus Support for HP Logic Analyzers
_______________________________________________________________________________
Post-processing Tool Sets
_______________________________________________________________________________
Probing Solutions for HP Logic Analysis Systems
_______________________________________________________________________________
Product overview 5966-3367E
Product overview 5966-3150E
Product overview 5964-2250E
Configuration guide 5966-4365E
Product overview 5966-3147E Product overview 5968-4632E
Warranty
HP hardware products are warranted against defects in materials and workmanship for a period of one year from date of shipment. If you send us a notice of such defects during the warranty period, we will either repair or replace hardware products that prove to be defective. Some newly manufactured HP products may contain remanufactured parts, which are equivalent to new in performance.
HP software and firmware products that are designated by HP for use with a hardware product are warranted for a period of one year from date of shipment to execute their programming instructions when prop­erly installed. If you send us notice of defects in materials workmanship during the warranty period, we will repair or replace these products, so long as the defect does not result from buyer-supplied hardware or interfacing. The warranty period is controlled by the warranty statement included with the product and begins on the date of shipment.
Page 20
For more information about the HP 16600A and 16700A Series logic analysis systems, visit our web site at: http://www.hp.com/go/las-data For more information about Hewlett-Packard Test & Measurement products, applications, services, and for a current sales office listing, visit our web site at: http://www.hp.com/go/tmdir You can also contact one of the follow­ing centers and ask for a test and measurement sales representative.
United States:
Hewlett-Packard Company Test and Measurement Call Center P.O. Box 4026 Englewood, CO 80155-4026 1 800 452 4844
Canada:
Hewlett-Packard Canada Ltd. 5150 Spectrum Way Mississauga, Ontario L4W 5G1 (905) 206 4725
Europe:
Hewlett-Packard European Marketing Centre P.O. Box 999 1180 AZ Amstelveen, The Netherlands (31 20) 547 9900
Japan:
Hewlett-Packard Japan Ltd. Measurement Assistance Center 9-1, Takakura-Cho, Hachioji-Shi, Tokyo 192, Japan Tel: (81) 426 56 7832 Fax: (81) 426 56 7840
Latin America:
Hewlett-Packard Latin American Region Headquarters 5200 Blue Lagoon Drive 9th Floor Miami, Florida 33126 U.S.A. Tel: (305) 267-4245/4220 Fax: (305) 267-4288
Australia/New Zealand:
Hewlett-Packard Australia Ltd. 31-41 Joseph Street Blackburn, Victoria 3130, Australia Tel: 1 800 629 485 (Australia)
0800 738 378 (New Zealand)
Fax: (61 3) 9210 5489
Asia Pacific:
Hewlett-Packard Asia Pacific Ltd. 17-21/F Shell Tower, Times Square, 1 Matheson Street, Causeway Bay, Hong Kong Tel: (852) 2599 7777 Fax: (852) 2506 9285
Netscape is a U.S. trademark of Netscape Communications Corp. Microsoft is a U.S. registered trademark of Microsoft Corp. Pentium is a U.S. registered trademark of Intel Corp. PostScript is a trademark of Adobe Systems Incorporated. Windows 95, 98 and NT are U.S. registered trademarks of Microsoft Corp. Unix is a registered trademark of the Open Group.
Technical information in this document is subject to change without notice.
Printed in the U.S.A. 05/99 5966-3107E
Loading...