For models with serial number below 20070608001
Remove Packaging
Your ice machine has been packed for shipment with all parts that could be damaged by movement securely fastened. Before installing the ice machine, be sure all packing materials and tape have been removed.
Important
Save the carton packaging until your ice machine has been thoroughly inspected and found to be in good condition. If there is damage, the packaging will be needed as proof of damage sustained in transit.
Starting Out
All specifications and product design subject to change without notice.
Such revisions do not entitle the buyer to corresponding changes, improvements,
additions, replacements or compensation for previously purchased products.
2
Installation
Select Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Cabinet Clearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Electrical Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Grounding Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Drain Plumbing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Water Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
Caring for Your Ice Machine
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Care of the Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Help Prevent Tragedies . . . . . . . . . . . . . . . . . . . . . . . . . .6
Cleaning Your Ice Machine . . . . . . . . . . . . . . . . . . . . . .7
Things to Remember . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Obtaining Service
Before Calling for Service . . . . . . . . . . . . . . . . . . . . . . . .9
How to Obtain Service . . . . . . . . . . . . . . . . . . . . . . . . . .9
For Your Records . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Troubleshooting
Troubleshooting One . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Troubleshooting Two . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Troubleshooting Three . . . . . . . . . . . . . . . . . . . . . . . . .12
Troubleshooting Four . . . . . . . . . . . . . . . . . . . . . . . . . .13
Warranty Information
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Installation
All specifications and product design subject to change without notice.
Such revisions do not entitle the buyer to corresponding changes, improvements,
additions, replacements or compensation for previously purchased products.
3
Cabinet Clearance
Ventilation is required for the bottom front section of the unit where the grille is located. Keep this area open and clear of any obstructions.
Adjacent cabinets and countertop can be built around the unit as long as no top trim or countertop is installed lower than the top of the hinge. Make certain that the glides supplied with the ice machine are installed according to instructions. Make certain your ice machine is level. Leveling adjustments can be made by raising or lowering the glides on the bottom of the unit.
Electrical Connection
Check the serial nameplate for the correct power supply. Use only the electrical power supply specified on the serial nameplate. Do not use an extension cord.
Grounding Method
This ice machine is equipped with a power supply cord with ground. It must be plugged into a mating grounding type receptacle in accordance with the National Electrical Code and applicable local codes and ordinances.
THIS UNIT SHOULD NOT, UNDER ANY CIRCUM-
STANCES, BE UNGROUNDED.
DISCONNECT POWER SOURCE BEFORE
ADJUSTING LEVELING LEGS
Select Location
The proper location will ensure peak performance of your ice machine. Choose a location away from heat and out of direct sunlight. Best performance will be maintained when installed within the following parameters:
Ideal Ambient Temperature Range*
built-in freestanding
* Ice Machine will not perform correctly in ambient temperatures less than 55°F.
55-80°F 55-90°F
Installation: Drain Plumbing
All specifications and product design subject to change without notice.
Such revisions do not entitle the buyer to corresponding changes, improvements,
additions, replacements or compensation for previously purchased products.
4
Drain Plumbing
Your ice machine uses a gravity drain, (figure 1) that requires 5/8" I.D. tubing from the back of the ice machine to a plumbed connection to a sanitary sewer. Remove the access panel to plumb in drain connection. Gravity drain location for built-in units can be within the area shown in figure 3. An optional drain pump, (figure 2) can be purchased for your ice machine if a gravity drain is not accessible.
OBSERVE AND FOLLOW ALL LOCAL CODES WHEN INSTALLING ICE MACHINE.
Gravity Drain Location
* With optional filler kit
FAILURE TO USE ADEQUATE DRAINAGE SYSTEM
WILL RESULT IN SURROUNDING WATER DAMAGE
AND/OR POOR ICE PRODUCTION.
figure 1
figure 2
figure 3
Water Supply
All specifications and product design subject to change without notice.
Such revisions do not entitle the buyer to corresponding changes, improvements,
additions, replacements or compensation for previously purchased products.
5
Water Supply
This ice machine must be connected to a potable, active cold water supply line delivering water pressure at a minimum of 20 psi and maximum of 120 psi.
• Water connection is made through a right angle garden hose fitting. See garden hose fitting for detailed instruc­tion sheet.
• A water filter is recommended for this unit. A quality filter can remove particles as well as remove taste and odors from water. Do not use any thread sealers.
• Softened water is not recommended. This will produce mushy, cloudy ice cubes that will stick together.
• De-ionized water is not recommended. This water will not form solid ice cubes.
• A water specialist can recommend proper water treat­ment.
• After installation of water line, turn on water and check for any leaks. Additional tightening may be needed.
• Allow for extra water line for built-in installations for easy removal of unit and to help prevent the water line from kinking.