AGA marvel MP24BCF4, MP24BCG4, MP24RAS4, MP24RAP4, MP24BRG4 Installation, Operinstallation, Operation And Maintenance Instructions

...
Page 1
EN Installation, Operation and Maintenance Instructions
FR Instructions d’installation, d’utilisation et d’entretien ES Instrucciones de instalación, operación y mantenimiento
Built in Refrigerators Réfrigérateurs intégrées Refrigeradores empotradas
MP15BCG4** MP15BCF4** MP24BCG4** MP24BCF4** MP24BRG4** MP24BRF4** MP24RAS4** MP24RAP4** MP24WBG4** MP24WBF4**
Page 2
INSTALLING YOUR APPLIANCE
Select Location
The proper location will ensure peak performance of your appliance. We recommend a location where the unit will be out of direct sunlight and away from heat sources. To ensure your product performs to specications, the recom­mended installation location temperature range is from 55 to 100°F (13 to 38°C).
Cabinet Clearance
Ventilation is required from the bottom front of the appli­ance. Keep this area open and clear of any obstructions. Adjacent cabinets and counter top can be installed around the appliance as long as the front grille remains unobstruct­ed. All Marvel Professional models with articulated hinges are intended for built-in applications only.
!
WARNING
An optional stacking kit, for 24" wide models, is re­quired to stack products. Failure to use a stacking kit could result in personal injury. Contact your dealer or Aga Marvel customer service at 800-223-3900 to order. For safety concerns 15" wide models should not be stacked.
Front Grille, keep this area open.
Front Leveling Legs
Figure 2
Rear
Leveling
Legs
Leveling Legs
Adjustable legs at the front and rear corners of the appli-
ance should be set so the unit is rmly positioned on the oor and level from side to side and front to back. The over-
all height of your Marvel appliance may be adjusted higher (by turning the leveling leg out, CCW) and lower (by turning the leveling leg in, CW) dimensions as shown in Table "A".
To adjust the leveling legs, place the appliance on a solid
surface and protect the oor beneath the legs to avoid scratching the oor. With the assistance of another person,
lean the appliance back to access the front leveling legs. Raise or lower the legs to the required dimension by turning the legs. Repeat this process for the rear by tilting the appli­ance forward using caution. On a level surface check the appliance for levelness and adjust accordingly.
!
CAUTION
Front Grille
Do not obstruct the front grille. The openings within the
front grille allow air to ow through the condenser heat ex­changer. Restrictions to this air ow will result in increased
energy usage and loss of cooling capacity. For this reason it is important this area to not be obstructed and the grille openings kept clean. AGA MARVEL does not recommend the use of a custom made grille as air ow may be restrict­ed. (See Figure 2).
The front grille screws may be loosened and the grille ad­justed to the desired height. When adjustment is complete tighten the two front grille screws. (See Figure 5).
Model Door Style
MP(15)(24)* (S) or (G)
MP(15)(24)* (F)
Minimum
Height
34"
(86.4 cm)
34"
(86.4 cm)
Table A
Maximum
Height
35"
(88.9 cm)
35"
(88.9 cm)
4
Page 3
INSTALLING YOUR APPLIANCE
!
WARNING
Figure 3
Do not remove ground prong
Figure 4
Electrical Shock Hazard
• Do not use an extension cord with this appliance. They can be hazardous and can degrade product performance.
• This appliance should not, under any circumstanc­es, be installed to an un-grounded electrical supply.
• Do not remove the grounding prong from the power cord. (See Figure 3).
• Do not use an adapter. (See Figure 4).
• Do not splash or spray water from a hose on the appliance. Doing so may cause an electrical shock, which may result in severe injury or death.
Electrical Connection
A grounded 115 volt, 15 amp dedicated circuit is required.
This product is factory equipped with a power supply cord that has a three-pronged, grounded plug. It must be plugged into a mating grounding type receptacle in accor­dance with the National Electrical Code and applicable lo­cal codes and ordinances (see Figure 6). If the circuit does not have a grounding type receptacle, it is the responsibility and obligation of the customer to provide the proper power supply. The third ground prong should not, under any cir­cumstances, be cut or removed.
Front grille
Front grille screw
Figure 5
Figure 6
NOTE
Ground Fault Circuit Interrupters (GFCI) are prone to nui­sance tripping which will cause the appliance to shut down. GFCI’s are generally not used on circuits with power equip­ment that must run unattended for long periods of time, un­less required to meet local building codes and ordinances.
5
Page 4
OVERLAY DOOR PANEL INSTALLATION
!
WARNING
Use extreme caution with the articulated hinges. The hinge is self closing and many pinch points exist prior to built-in installation. Do not remove the cabinet "Z"
bracket from the top of the cabinet.
Press and hold this down this tab on the wire connec­tor and pull the connector apart.
Step 2: Remove the door gasket
With the door laying on a at surface and starting at a
corner of the door remove the magnetic door gasket from the interior side of the door, see Figure 13. Set the gasket
aside on a at surface.
There are 10 holes in the gasket retainer extrusions, (3 on each side and 2 at the top and bottom which are used to fasten the panel to the front of the door. The screws are provided in the literature pack along with the door lock, which is provided on certain models.
Loosen (do not remove ) these 2 phillips head screws on the top and bottom hinges
Figure 11a
Cabinet "Z" Bracket
Figure 12
Holes in
gasket
retainer.
Figure 13a
Overlay panel
ush with top
and side of
door.
Overlay panel to be centered on width of door.
Figure 11
"P" clamp and screw
Figure 11b
Bottom of
door
Wire connector see Figure 12
Magnetic Gasket remove starting at a corner, grasp and pull away from the door.
Figure 13
Step 3: Cut and drill the overlay panel
Depending on your model cut the overlay door panel to the dimensions shown in Figures 14 to 21. The window cut out is for glass door models only. If your appliance has a lock also drill the lock hole in the panel, see Figure 22.
13
Page 5
Clearance for
screw head,
4 places
OVERLAY DOOR PANEL INSTALLATION
!
CAUTION
Weight of overlay door panel must not exceed 15 pounds (6.8 kg) for a solid door model or 10 pounds (4.5 kg) for a glass door model.
Clearance for hinge 2 places
Top of door
Clearance
for hinge
2 places
1" (25.4 mm) diameter counter bore 1⁄4" (6.4mm) deep 4 places.
327⁄32"
(9.7 cm)
31⁄8"
(7.9 cm)
Minimum
15⁄32"
(2.9 cm)
41⁄8"
(10.5 cm)
Minimum
Hinge side of door
Figure 14
Left Hand Hinged Door
15" (38.1 cm) wide appliance
143⁄4"
(37.5 cm)
5"
(12.7 cm)
13⁄16"
(3 cm)
1
⁄4" (6 mm)
radius is permissible
This side facing interior
47⁄8"
(12.4 cm)
1
31⁄8"
(7.9 cm)
31⁄8"
(7.9 cm)
Minimum
⁄4" (6 mm)
Deep
13⁄4"
(4.4 cm)
3011⁄32"
(77.1 cm)
Figure 16
Right Hand Hinged Door
15" (38.1 cm) wide appliance
1
⁄4" (6 mm)
13⁄4"
(4.4 cm)
3011⁄32"
(77.1 cm)
Deep
31⁄8"
(7.9 cm)
31⁄8"
(7.9 cm)
Minimum
(37.5 cm)
47⁄8"
(12.4 cm)
This side facing interior
143⁄4"
5"
(12.7 cm)
13⁄16"
(3 cm)
1
⁄4" (6 mm)
radius is permissible
Hinge side of door
Clearance for
screw head,
4 places
1" (25.4 mm) diameter counter bore 1⁄4" (6 mm) deep 6 places.
327⁄32"
(9.7 cm)
31⁄8"
(7.9 cm)
Minimum
15⁄32"
(2.9 cm)
111⁄16"
(4.3 cm)
11⁄2"
(3.8 cm)
typical
311⁄16"
(9.4 cm)
Figure 15
Left Hand Hinged Door
15" (38.1 cm) Wide Appliance
2"
(5.1 cm)
14
2"
(5.1 cm)
311⁄16"
(9.4 cm)
11⁄2"
(3.8 cm)
typical
111⁄16"
(4.3 cm)
Figure 17
Right Hand Hinged Door
15" (38.1 cm) wide appliance
41⁄8"
(10.5 cm)
Minimum
Page 6
OVERLAY DOOR PANEL INSTALLATION
Clearance for
screw head,
4 places
Top of door
24" (61 cm) wide appliance
233⁄4"
(60.3 cm)
Clearance for hinge at top and bottom
Hinge side of door
Figure 18
Left Hand Hinged Door
1
⁄4"
(6 mm)
Deep
Clearance
for hinge
Top of door
at top and
bottom
Hinge side of door
Figure 20
Right Hand Hinged Door
24" (61 cm) wide appliance
233⁄4"
1
⁄4"
(6 mm)
Deep
(60.3 cm)
Clearance for screw head, 4 places
31⁄8"
(7.9 cm)
15⁄32"
(2.9 cm)
111⁄16"
(4.3 cm)
11⁄2"
(3.8 cm)
typical
47⁄8"
(12.4 cm)
14"
(35.6 cm)
13⁄16"
(3 cm)
327⁄32"
(9.8 cm)
1
⁄4" (6 mm)
radius is permissible
31⁄8"
(7.9 cm)
This side to door
41⁄8"
(10.5 cm)
1" (2.5 cm) diameter x 1⁄4" (6 mm) deep 4 places
Figure 19
Left Hand Hinged Door
24" (61 cm) wide appliance
(4.4 cm)
31⁄8"
(7.9 cm)
311⁄16"
(9.4 cm)
13⁄4"
(5.1 cm)
3011⁄32"
(77.1 cm)
2"
15
(4.4 cm)
31⁄8"
(7.9 cm)
3011⁄32"
(77.1 cm)
2"
(5.1 cm)
13⁄4"
31⁄8"
(7.9 cm)
311⁄16"
(9.4 cm)
14"
(35.6 cm) 13⁄16"
(3 cm)
1
⁄4" (6 mm)
327⁄32"
(9.8 cm)
(12.4 cm)
radius is permissible
This side to door
41⁄8"
(10.5 cm)
1" (2.5 cm) diameter
x 1⁄4" (6 mm) deep
4 places
Figure 21
Right Hand Hinged Door
24" (61 cm) wide appliance
47⁄8"
31⁄8"
(7.9 cm)
15⁄32"
(2.9 cm)
111⁄16"
(4.3 cm)
11⁄2"
(3.8 cm)
typical
Page 7
!
CAUTION
OVERLAY DOOR PANEL INSTALLATION
Weight of overlay door panel must not exceed 15 pounds (6.8 kg) for a solid door model or 10 pounds (4.5 kg) for a glass door model.
Material Type #10 Wood Screw
Hardwood
Softwood
1
⁄8" (3.2 mm) Diameter. Pilot Hole
7
⁄64 (2.8 mm) Diameter. Pilot Hole
Table B
Step 4: Assemble the panel to the door
The preferred method of attaching the panel to the door is to clamp the panel to the door so it cannot move while drilling the screw pilot holes. Use bar clamps or "C" clamps with pads on the clamping surfaces that will not mar the panel or the door. The custom overlay panel should be
ush with the top of the door and centered along the width
of the door. See Figure 13a. Drill holes through the gasket extrusion using the 10 holes as pilot holes. Use the drill size from the chart in Table "B", being careful not to drill through the front surface of the panel. If the overlay panel is thinner than 5⁄8" (16 mm) thick shorter screws will have to be obtained. Fasten the panel to the door with the 10 screws provided in the literature pack. (See Figure 22a). Remove the clamps and replace the gasket in the gasket extrusion channels of the door. Some force may be required to seat the gasket into the channels. Be sure the gasket corners are seated properly.
#10 x 1⁄2"
screw
17
⁄32"
(13.7 mm)
Counter bore lock hole on back side.
Figure 22a
31⁄2"
(89 mm)
1
⁄2" (13 mm) diameter drill
through door panel, from other side (see detail above) 13⁄16" (20.5 mm) counter bore, 7⁄16" (11 mm) deep.
Hinge side of door
Figure 22
16
Page 8
OVERLAY DOOR PANEL INSTALLATION
Step 5: Assemble lock parts
Two (2) lock extensions are provided with the lock. Use the longer extension for 3⁄4" thick overlay panels and the shorter one for 5⁄8" thick overlay panels. Assemble the lock exten- sion, cam stop washer, spring washer, and set screw to the lock as shown in Figure 23 and 24.
Install this lock assembly into the lock hole in the overlay panel and secure with the retaining nut on the back side with a 15 mm socket and ratchet. Make sure the key slot in the front of the lock is vertical.
BRASS EXTENSION
SPRING WASHER
NUT
LOCK
1/2 HOLE
13/16 COUNTER
BORE 7/16 DEEP
CAM
PHILLIPS SCREW
Step 7: Install the door
Carefully open the top and bottom hinges on the door being careful as there are many pinch points. Place the hinges over the 4 screws in the cabinet, 2 at the top and 2 at the bottom and slide the door into position. Tighten the 4 hinge screws with a phillips screwdriver. (See Figures 11 and 11a). Place wire harness from the grille and mount to the bottom of the door with the screw and "P" clamp removed in step 1. (See Figure 11b). Reconnect the wire harness, (See Figure 12).
Step 8: Secure the cabinet
Use the #8 x 3⁄4" black screws from the literature pack to secure the counter top to the cabinet top through the holes in the cabinet "Z" bracket.
INNER
3/4 INCH
WOOD PANEL
SECTION A-A
SCALE 1 : 1
DOOR
Figure 23
Step 6: Install lock cam
Attach the lock cam to the back of the lock assembly with the phillips head screw provided. Orient the lock cam verti­cally when installing on the lock.
Screw
Brass extension (2 lengths provided)
Key
Retainer nut
Spring washer
Lock
Cam
Cam stop washer
Figure 24
Set screw
Cabinet "Z" bracket
#8 x 3⁄4" black screws (3 places)
Figure 25
17
Loading...