Aga marvel MO15CRS1XS User Manual

Installation Operation and Maintenance Instructions
Ice Machine
MO15CRS1XS (Outdoor)
Installation Operation and Maintenance Instructions
Contents
Safety
Safety and Warning
Disposal and Recycling
Installation
Environmental Requirements
Electrical
Cutout Dimensions
Product Dimensions
Side by Side Installation
Water Hookup
Anti-Tip Bracket
General Installation
Service
Troubleshooting
Warranty
Obtaining Service
Grille Installation
Door Swing
Door Adjust
Operating Instructions
First Use
Ice
Airflow and Product Loading
Maintenance
Cleaning
Cleaning Condenser
Extended Non-Use
2
Installation Operation and Maintenance Instructions
Welcome to the Marvel Experience
Congratulations on adding a new Marvel crescent ice maker to your home and thank you for choosing our quality American-built product. You’ll enjoy years of crescent ice in the comfort and convenience of your home, backed by our full worry-free warranty. We are thrilled to welcome you to our growing community of Marvel owners, who trust in our products and our support.
The information in this guide is intended to help you install and maintain your new Marvel crescent ice maker to protect and prolong the lifetime of your unit. We encourage you to contact our Technical Support team at (800) 223-3900 with any questions.
Cheers!
3
Safety and Warning
NOTICE
Please read all instructions before installing, operating,
or servicing the appliance.
Use this
appliance for its intended purpose only and
follow these general precautions with those listed
throughout this guide:
SAFETY ALERT DEFINITIONS
Throughout this guide are safety items labeled with a
Danger, Warning or Caution based on the risk type:
! DANGER
Danger means that failure to follow this safety statement
will result in severe personal injury or death.
! WARNING
Warning means that failure to follow this safety
statement could result in serious personal injury or
death.
! CAUTION
Caution means that failure to follow this safety
statement may result in minor or moderate personal
injury, property or equipment damage.
Installation Operation and Maintenance Instructions
Disposal and Recycling
! DANGER
RISK OF CHILD ENTRAPMENT. Before you throw away
your old refrigerator or freezer, take off the doors and
leave shelves in place so children may not
inside.
If the unit is being removed from service for disposal, check
and obey all federal, state and local regulations regarding
the disposal and recycling of refrigeration appliances, and
follow these steps completely:
easily climb
1. Remove all consumable contents from the unit.
2. Unplug the electrical cord from its socket.
3. Remove the door(s)/drawer(s).
Environmental Requirements
This unit is designed to operate between 50°F (10°C) and
100°F (38°C). Higher ambient temperatures may reduce the
unit’s ability to reach low temperatures and/or reduce ice
production on applicable models.
For best performance, keep the unit out of direct sunlight
and away from heat generating equipment.
In climates where high humidity and dew points are present,
condensation may appear on outside surfaces. This is
considered normal. The condensation will evaporate when
the humidity drops.
! WARNING
CALIFORNIA PROPOSITION 65
This product contains chemicals known to the state
of California to cause cancer and birth defects or
other reproductive harm.
www.P65warnings.CA.gov
! CAUTION
Damages caused by ambient temperatures of 40°
F (4°C) or below are not covered by the warranty.
4
Electrical
! WARNING
SHOCK HAZARD Electrical Grounding Required.
Never attempt t
o repair or perform
maintenance
on
the
unit unt
il
the electricity has been disconnected.
Never remove the round grounding prong from the plug
and never use a two-prong grounding adapter.
Altering, cutting or removing power cord, removing
power plug, or direct wiring can cause serious injury,
fire, loss of property and/or life, and will void the
warranty.
Never use an extension cord to connect power to the unit.
Always keep your working area dry.
NOTICE
Electrical installation must observe all state and local
codes. This unit requires connection to a grounded
(three-prong), polarized receptacle that has been placed
by a qualified electrician.
The unit requires a grounded and polarized 115 VAC, 60
Hz, 15A power supply (normal household current). An
individual, properly grounded branch circuit or circuit breaker
is recommended. A GFCI (ground fault circuit interrupter) is
usually not required for fixed location appliances and is not
recommended for your unit because it could be prone to
nuisance tripping. However, be sure to consult your local
codes.
See CUTOUT DIMENSIONS for recommended receptacle
location.
Installation Operation and Maintenance Instructions
Cutout Dimensions
PREPARE SITE
Your AGA Marvel product has been designed for either free-
standing or built-in installation. When built-in, your unit does
not require additional air space for top, sides, or rear. However,
the front grille must NOT be obstructed, and clearance is
required for an electrical connection in the rear.
! CAUTION
Unit can NOT be installed behind a closed cabinet door.
CUTOUT DIMENSIONS
Preferred location for water line and eletrical outlet is in
34-1/4"
(870 mm)
to 35"
(889 mm)
adjacent cabinet.
7"
(178 mm)
4"
(102 mm)
15-1/4"
(387 mm)
24"
(610 mm)
(16 mm)
5/8"
5
Installation Operation and Maintenance Instructions
Product Dimensions
Not Including Handle
*Add 3/4" To Depth For Water Line Clearance
6
Side-by-Side Installation
Two units may be installed side-by-side.
Cutout width for a side-by-side installation is the
cutout dimension of a single unit times two.
No trim kit is required. However, 1/4" (6 mm) of space
needs to be maintained between the units to ensure
unobstructed door swing.
Units must operate from separate, properly grounded
electrical receptacles placed according to each unit’s
electrical specifications requirements.
Side-by-Side Installation with Bracket
1. Slide both units out so screws on top of units are easily
accessible.
2. Remove screws as shown below.
3. Place bracket over holes and attach to unit with two
screws removed in step 2 using a T-25 Torx driver.
Tighten screws fully.
4. Gently push units into position. Be careful not to entangle
the electrical cord or water line, if applicable.
5. Re-check the leveling, from front to back and side to side.
Make any necessary adjustments. The unit’s top surface
should be approximately 1/8" (3 mm) below the
countertop.
Installation Operation and Maintenance Instructions
7
Water Hookup
PREPARE PLUMBING
The water valve uses a standard 1/4" (6.35 mm)
compression fitting.
! CAUTION
Plumbing installation must observe all state and local
codes. All water and drain connections MUST BE made
by a licensed/qualified plumbing contractor. Failure to
follow recommendations and instructions may result in
damage and/or harm.
Water Supply Connection
When connecting the water supply, please note the following:
Before installing the unit and connecting to the cold water
supply, review the local plumbing codes.
The water pressure should be between 20 and 120 psi
(138 and 827 kPa).
The water line MUST have a shut-off valve in the supply
line.
The water line should be looped into 2 coils. This will allow
the unit to be removed for cleaning and servicing. Make
certain that the tubing is not pinched or damaged during
installation.
! CAUTION
Do not use any plastic water supply line. The line is under
pressure at all times. Plastic may crack or rupture with
age and cause damage to your home.
Do not use tape or joint compound when attaching a
braided flexible water supply line that includes a rubber
gasket. The gasket provides an adequate seal other
materials could cause blockage of the valve.
Failure to follow recommendations and instructions may
result in damage and/or harm, flooding or void the
product warranty.
! CAUTION
Turn off water supply and disconnect electrical supply
to unit prior to installation.
Use caution when handling back panel. The edges
could be sharp.
1. Turn off water supply and disconnect electrical supply to
product prior to attempting installation.
2. Remove the back panel.
Installation Operation and Maintenance Instructions