AFX SHP620ACSCTD User Manual

SHP Series Fluorescent Pendant
Models 413/420/613/620
Safety Precautions
It is recommended that a qualified electrician perform all wiring. This fixture must be wired in accordance with all national and local electrical codes.
Do not handle any energized fixture or attempt to energize any fixture with wet hands or while standing on a wet or damp surface or in water.
Make sure that the power source conforms to the requirements of the fixture. (See labels on fixture housing).
Assembly Instructions
1. Preparing for installation.
A. Disconnect electrical power before installing or servicing any part of this fixture. B. Unpack and lay out all fixture components to verify everything is included to fully assemble the fixture. C. Please affix all stems with supplied thread locker to prevent stems from coming undone when assembled.
2. Fixture assembly - Lighting fixture is partially assembled
A. Take the fixture power wires (black and white) and slide them through the 1 ½”stem assembly (8). Thread the
stem assembly on to the fitting (9) on top of the socket plate until secure.
B. Insert wires through stem (7) and screw stem on to top nipple of the 1 ½” stem assembly (8). C. Slide diffuser support (11-only found on 6-lamp unit) over 1 ½” stem assembly and allow it to rest on top of the
ballast/lamp mounting tray. For the 4-lamp unit, there is a diffuser support ring pre-attached. NOTE: Verify Step 2C is completed prior to moving on for the 6-lamp unit only.
D. Slide wires through ¾” threaded nipple (5) and screw nipple ¼” into stem assembly. Slide wires through swivel
NOTE: Two 6” and two 12” stems included for desired height between hanger assembly and canopy.
3. Fixture mounting.
A. Install short screws provided into threaded holes near ends
B. Insert 1 ½” (1) screws through slots in mounting bracket (2)
4. Wiring. Caution: Make sure power is off at fuse or circuit breaker box.
Check power wires for damage or scrapes. If power supply wires are within three inches of ballast use wire suitable for at least 90C (194F). Note: Most dwellings built before 1985 have supply wire rated to 60C. Consult a qualified electrician before installing.
A. This unit will not operate properly unless connected to a
*MV model shown with 4-pin CFLs
*MV model shown with 4-pin CFL’s
Page 1 of 2 8060317 Rev. 7
Models ending in MV power source 120-277V Non-dimmable
Models ending in SCTD power source 120V (Self Ballasted dimmable CFL) Usable on a dimming circuit with dimmable lamps
To reduce the risk of electrical shock, and to assure proper operation, this fixture must be adequately grounded. To accomplish proper grounding there must be a separate ground wire (green) or bare metal contact (metal conduit) between this fixture and the ground connection of your main power supply panel.
This fixture is intended for use as general lighting in dry or damp locations.
(4) and canopy (3) assembly, and tighten.
of mounting bracket (2). Be sure these screws line up with holes in canopy (3).
and secure to junction box in ceiling (not provided). Be sure short screws in bracket point towards floor. Slide supply wires through center hole of mounting bracket.
“grounded” electrical circuit. Electrical shock, over heating, low or now light output, and shortened lamp life can result if proper grounding is not done. Securely attach green (or green and yellow) wire to ground.
SHP Series Fluorescent Pendant
Models 413/ 613
B. For models ending in SCTD – using wire connectors provided, connect white supply wire to white ballast lead.
Connect black hot supply wire to black ballast lead. For models ending in MV – Using luminaire disconnect (provided), insert white supply wire into the hole across from white ballast lead. Insert black hot supply wire into hole across from black ballast lead. Do not mix wires. Pull on each wire to make sure connections are secure. Make certain no bare wires are exposed outside of wire connectors.
C. Line up the two holes in the canopy (3) with the two screws in the mounting bracket. Secure fixture to screws
with the two thumb nuts (6) provided.
5. Lamp Installation (Lamps included on models ending with “SCTD”).
A. For model ending in MV, use only 13 watt fluorescent, quad 4-pin lamps (10). To
install, line-up lamp pins with the corresponding holes in the lamp socket (12) and push lamp into place until a click is heard. Repeat for each lamp.
B. For models ending in SCTD (See Detail B) usable on a dimming circuit with
dimmable GU24 base lamps, use only GU24 base lamps (26W max.). To install, line up lamp pins with the corresponding holes in lamp socket and turn clockwise until a click is heard. Repeat for each lamp.
NOTE: BE CAREFUL NOT TO ROTATE PENDANT DURING LAMP INSTALLATION/REPLACEMENT
6. Diffuser Installation
A. On the 6-lamp unit, line up the diffuser support (11) with the tabs (15) on the inside of
the diffuser (14); they should rest under each tab.
B. Thread long nipple with cap (13) into fitting in bottom of ballast housing assembly
approximately ¼”. Line up center hole in diffuser (14) with cap, center hole in cap to nipple and secure with finial (15).
C. For the 4-lamp unit (see Detail C), there is a hang straight (D) for the diffuser. Thread the long nipple (C) into the
coupling (G) on hub (A) and use hexnut (B) to keep the stem from rotating. Next, thread the hang straight (D) onto the nipple (C). Place the diffuser collar (E) into the center hole on the diffuser (F) and place them into the threaded part of the hang straight and tighten with finial (F). Use a level to adjust the diffuser from the top side.
DETAIL C
Limited Factory Warranty American Fluorescent Corporation hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under normal operating conditions for a period of 2 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture or components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.
DETAIL B
Page 2 of 2 8060317 Rev. 7
Loading...