AFX DEF18226QMVSN User Manual

Delta Flushmount Fluorescent Fixtures
Model: DEF226MV
Safety Precautions
Read all safety precautions and installation instructions carefully before installing or servicing this fixture. Failure to comply with these instructions could result in potentially fatal electric shock and/or property damage.
It is recommended that all wiring be performed by a qualified electrician. This fixture must be wired in accordance with all national and local electrical codes.
Do not handle any energized fixture or attempt to energize any fixture with wet hands or while standing on a wet or damp surface or in water.
Assembly Instructions
1. Preparing for installation
A. Disconnect electrical power before installing or servicing
any part of this fixture.
B. Remove fixture from carton; remove backpan assembly,
diffuser and hardware kit.
C. Install four metal brackets (2) on the diffuser (1) with four
(3) screws.
D. Thread two (5) screws (provided) into the cross gem bar
(6). Leave about ½” length exposed.
E. Install cross gem bar (6) on the junction box (not provided) by securing it with two (4) screws.
2. Wiring
All wiring must take place inside junction box. Caution: Make sure power is off at fuse or circuit breaker box. Check power
wires for damage or scrapes. If power supply wires are within three inches of ballast use wire suitable for at least 90C (194F). Note: Most dwellings built before 1985 have supply wire rated to 60C. Consult a qualified electrician before installing.
Make sure that the power source conforms to the requirements of the fixture. (See labels on fixture housing). Model numbers ending in MV are designed for use in a 120-277VAC, 60Hz fused circuit (Do not use on a dimming circuit). To reduce the risk of electrical shock, and to assure proper operation, this fixture must be adequately grounded. To accomplish proper grounding, there must be a separate ground wire (green) or bare metal contact (metal conduit) between this fixture and the ground connection of your main power supply panel.
This fixture is intended to be used for general indoor lighting in dry or damp locations only.
A. This unit will not operate properly unless connected to a
“grounded” electrical circuit. Electrical shock, over heating,
low or no light output, and shortened lamp life can result if proper grounding is not done. Securely attach green (or green and yellow) wire to ground supply wire.
B. For wiring ballast power leads and power supply
wires use Ballast disconnect Instructions (provided).
C. Tuck all connections neatly into junction box.
3. Mounting
A. Align the backpan (7) keyslots with screws (5). Insert screws
(5) through the keyslot openings. Twist backpan and secure it by tightening screws (5).
4. Lamps
A. Install compact fluorescent lamps (8) (not provided) into
sockets (9).
5. Diffuser mounting
A. Raise diffuser to ceiling pan and align diffuser brackets with
all 4 ceiling pan slots.
B. Insert diffuser over slots and then rotate 1/8 turn clockwise
until diffuser brackets rest in corresponding notches.
C. Verify brackets are properly seated in notches by attempting to rotate diffuser. It should NOT rotate if properly installed.
6. Power to the fixture can now be restored.
Limited Factory Warranty American Fluorescent Corporation hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under
normal operating conditions for a period of 2 years from date of shipment from factory. This warranty covers all component parts and extends only to replacement of defective fixture or components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred
in transit.
Page 1 of 1 8060688 R1