AFX CSF12122C941EN User Manual

CSS Series Low Profile Soft Edge Fixture
Models 2013, 2022, 2026, 2032, 2039, 2054, 2072
Safety Precautions
It is recommended that all wiring be performed by a qualified electrician. This fixture must be wired in accordance with all national and local electrical codes.
Do not handle any energized fixture or attempt to energize any fixture with wet hands or while standing on a wet or damp surface or in water.
Assembly Instructions
1. Preparing for installation
A. Disconnect electrical power before installing or servicing any part of
this fixture.
B. Remove diffuser, unlatch levers (9) on opposite sides and gently remove
diffuser.
2. Wiring.
All wiring must take place inside junction box. Caution: Make sure
power is off at fuse or circuit breaker box. Check power wires for damage or scrapes. If power supply wires are within three inches of ballast use wire suitable for at least 90C (194F). Note: Most dwellings built before 1985 have supply wire rated to 60C. Consult a qualified electrician before installing.
Make sure that the power source conforms to the requirements of the fixture. (See labels on fixture housing).
To reduce the risk of electrical shock, and to assure proper operation, this fixture must be adequately grounded. To accomplish proper grounding, there must be a separate ground wire (green) or bare metal contact (metal conduit) between this fixture and the ground connection of your main power supply panel. The green ground screw location is clearly marked on the fixture housing.
This fixture is intended to be used for general indoor lighting in dry or damp locations only.
A. This unit will not operate properly unless connected to a “grounded”
electrical circuit. Electrical shock, over heating, low or no light output, and shortened lamp life can result if proper grounding is not done. Securely attach green (or green and yellow) wire to ground supply wire.
B. Using wire connectors (provided), connect white supply wire to white
ballast lead. Connect black hot supply wire to black ballast lead. Do not mix wires. Pull on each wire lead to make sure connections are secure. Make certain no bare wires are exposed outside of wire connectors.
3. Mounting.
A. Mount housing (4) to junction box (not provided) with the two #8-32 x 7/8” screws (7) (provided) through keyhole slots (8).
4. Lamps
A. Circline- Install (small) lamp (2) around three inner clips (5) and connect the
wire harness connector from the ballast to the lamp that matches the lamp wattage. Install large lamp (3) around three outer clips (6) and connect the remaining wire harness connector from the ballast to the lamp.
B. Compact – Install lamps (11) by inserting lamp pins into lamp holder and press
until lamp snaps in place.
5. Diffuser mounting.
A. Install the square plastic diffuser (1). Align the diffuser (1) inside the bends and
to lock the diffuser in place you must rotate the latch until it stops. Make sure you locked all latches.
6. Power to the fixture can now be restored.
Limited Factory Warranty American Fluorescent Corporation hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under normal operating conditions for a period of 2 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture or components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.
Page 1 of 1 8060176 rev.2