AFX CRV221RBMV User Manual

CRV Series Fluorescent Vanity Fixture
Model 221
Safety Precautions
Read all safety precautions and installation instructions carefully before installing or servicing this fixture. Failure to comply with these instructions could result in potentially fatal electric shock and/or property damage.
It is recommended that a qualified electrician perform all wiring. This fixture must be wired in accordance with all national and local electrical codes.
Do not handle any energized fixture or attempt to energize any fixture with wet hands or while standing on a wet or damp surface or in water.
Assembly Instructions
1. Preparing for installation
A. Disconnect electrical power before installing or
servicing any part of this fixture.
B. After carefully unpacking the fixture, remove the ballast
cover (5) by removing the 2 thumbnuts (9) and pulling cover off mounting pan.
C. Install junction box cover plate (4) to junction box with
#8 screws (not provided).
D. Line up wire hole of mount pan with your junction box
(not provided). Use a level to be sure fixture is straight. Mark locations of mounting location with a pencil. Insert 1” wood screws (included) into marked holes leaving them about 1/8” away from wall. Where there is no joist for mounting use toggle bolts (not included) of suitable length to mount pan securely to wall.
E. Pull lead wires through wire hole, line up mounting slots
with screws and slide fixture in place. Tightening mount screws.
2. Wiring.
All wiring must take place inside junction box.
Caution: Make sure power is off at fuse or circuit breaker box. Check power wires for damage or scrapes. If power supply wires are
within three inches of ballast use wire suitable for at least 90C (194F). Note: Most dwellings built before 1985 have supply wire rated to 60C. Consult a qualified electrician before installing.
A. This unit will not operate properly unless connected to a “grounded” electrical circuit. Electrical shock, over heating, low or
no light output, and shortened lamp life can result if proper grounding is not done.
B. Using luminaire disconnect (provided), insert white supply wire into the hole across from white ballast lead. Insert black hot
supply wire into hole across from black ballast lead. Do not mix wires. Pull on each wire to make sure connections are secure. Make certain no bare wires are exposed outside of luminaire disconnect.
C. Replace the ballast cover by lining up the holes with the threaded studs (3) in the channel and thread thumbnuts (9) securely.
3.
Fixture Lamping.
A. This fixture uses 2 – 21 watt T5 linear fluorescent lamps (6 - not provided). B. Inserting lamp pins into sockets and rotate until lamp snaps into place.
This fixture is designed for use in a 120-277VAC, 60Hz fused circuit. Do not use on a dimming circuit.
To reduce the risk of electrical shock, and to assure proper operation, this fixture must be adequately grounded. To accomplish proper grounding, there must be a separate ground wire (green) or bare metal contact (metal conduit) between this fixture and the ground connection of your main power supply panel. The green ground screw location is clearly marked on the fixture housing.
This fixture is intended for use for general indoor lighting in dry or damp locations only.
4. Diffuser installation.
A. Line the holes (7) on diffuser (8) with holes on diffuser mounting bracket and slide diffuser into place. Attach using thumb
screws (1) and adjust diffuser for tight fit to wall. Tighten thumbscrews.
B. Restore power at fuse or circuit breaker box.
Limited Factory Warranty American Fluorescent Corporation hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under normal operating conditions for a period of 2 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture or components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.
Page 1 of 1 8060452 rev.6