AFX CLF2232BKT User Manual

CLF2232
Model CLF2232
Safety Precautions
Read all safety precautions and installation instructions carefully before installing or servicing this fixture. Failure to comply with these instructions could result in potentially fatal electric shock and/or property damage.
It is recommended that a qualified electrician perform all wiring. This fixture must be wired in accordance with all national and local electrical codes.
Do not handle any energized fixture or attempt to energize any fixture with wet hands or while standing on a wet or damp surface or in water.
Fluorescent Ceiling Fixture
This fixture is designed for use in a 110-120VAC, 60Hz fused circuit. Do not use on a dimming circuit.
To reduce the risk of electrical shock, and to assure proper operation, this fixture must be adequately grounded. To accomplish proper grounding, there must be a separate ground wire (green) or bare metal contact (metal conduit) between this fixture and the ground connection of your main power supply panel. The green ground screw location is clearly marked on the fixture housing.
This fixture is intended for use for general indoor lighting in dry or damp locations only.
Assembly Instructions
1.
Preparing for installation
A. Disconnect electrical power before installing or servicing any part of this fixture.
2.
Wiring All wiring must take place inside junction box.
Caution: Make sure power is off at fuse or circuit breaker box.
Check power wires for damage or scrapes. If power supply wires are within three inches of ballast, use wire suitable for at least 90C (194F). Note: Most dwellings built before 1985 have supply wire rated to 60C. Consult a qualified electrician before installing.
A. This unit will not operate properly unless connected to a
B. Using orange wire connectors (provided), connect white
“grounded” electrical circuit. Electrical shock, over heating, low or no light output, and shortened lamp life can result if proper grounding is not done. Securely attach green (or green and yellow) wire to ground supply wire.
supply wire to white ballast lead. Connect black hot supply wire to black ballast lead. Connect the ground wires. Do not mix wires. Pull on each wire lead to make sure connections are secure. Make certain no bare wires are exposed outside of wire connectors.
3.
Mounting
A. Junction box mounting: Attach fixture pan (1) directly
to Junction box through eyelet holes with two #8 –32 x 1” screws (4) (provided).
4.
Lamps mounting
A. Install 22- and 32-watt circline lamps (5) using three clips (2), and connect the wire harness connector (3) from the ballast to
the lamp. Notes – engage clips (2) one at a time; either connector (3) can be plugged into either lamp (5). Route connector wires between lamps & ceiling pan to avoid seeing a shadow when lit.
5.
Diffuser installation
A. Align the three slots in the diffuser (6) with the three metal clips along the perimeter of the ceiling pan (1). Rotate the
diffuser clockwise until it stops in place, held between the clips and the ceiling pan. Note – removal of diffuser is the reverse of installation.
B. Restore power at fuse or circuit breaker box.
Limited Factory Warranty AFX hereby warranty that this fixture is free from defects in materials and workmanship when installed and used under normal operating conditions for a period of 2 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture or components; it does not cover failure due to improper installation, misuse, mishandling or damage incurred in transit.