Safety Precautions
Read all safety precautions and installation instructions carefully before installing or servicing this fixture. Failure to comply with these instructions could result in potentially fatal electric shock and/or property damage.
It is recommended that a qualified electrician perform all wiring. This fixture must be wired in accordance with all national and local electrical codes.
Do not handle any energized fixture or attempt to energize any fixture with wet hands or while standing on a wet or damp surface or in water.
ASSEMBLY INSTRUCTIONS
1. Preparing for installation
A. Disconnect electrical power at fuse or circuit breaker box
before installing or servicing any part of this fixture.
B. Carefully remove the fixture from the carton, and check
that all parts are included, as shown in Figure 1.
2. Wiring – all wiring must take place inside junction box Caution: Make sure power is off at fuse or circuit breaker
box. Check power wires for damage or scrapes. If power supply wires are within three inches of the ballast power supply, use wire suitable for at least 90C (194F). Note: Most dwellings built before 1985 have supply wire rated to 60C. Consult a qualified electrician before installing.
A. Connect the power source ground wire to the green or bare
copper wire from the fixture assembly.
B. Using wire nuts, connect white supply wire to white fixture lead. Connect black supply wire to
black fixture lead. Do not mix wires. Pull on each wire lead to make sure connections are secure. Make certain no bare wires are exposed outside of wire connectors. Note: fixtures with universal voltage power supplies are pre-wired with a disconnect. Refer to the included guide for using the disconnect.
C. Tuck all connections neatly into junction box.
Make sure that the power source conforms to the requirements of the fixture (see labels on fixture housing).
To reduce the risk of electrical shock, and to assure proper operation, this fixture must be adequately grounded. To accomplish proper grounding, there must be a separate ground wire (green) contact between this fixture and the ground connection of your main power supply panel.
This fixture is intended to be used for general indoor lighting in damp locations.
3. Mounting
A. Install fixture by securing the ceiling pan (1) to the ceiling using the semi-circular slots and/or
outer keyhole slots (Figure 2). Note: over-tightening can warp/bend the ceiling pan.
B. If required, install lamps (6). For CFQ lamps: push lamp into lamp holder until it snaps in
place. For GU24 lamps: insert lamp into lamp holder and turn it clockwise until it snaps in place.
C. Place diffuser (2) over ceiling pan. Install trim ring (4) and brackets (3)
using thumb nuts (5). Note – to enable single-person mounting, install trim ring with one bracket and thumb nut, then insert diffuser and install remaining brackets (Figure 3).
4. Restore power at fuse or circuit breaker box
8060360 r0