![](/html/a2/a2c3/a2c3aadb226991f8905ccd453884fb190490dab07a97fe238021d30468be457c/bg1.png)
Decorative Flushmount Fluorescent Ceiling Fixture
Model: 324620 & C213PBPLT 120VAC / 60Hz
Safety Precautions
Read all safety precautions and installation instructions carefully before
installing or servicing this fixture. Failure to comply with these
instructions could result in potentially fatal electric shock and/or
property damage.
It is recommended that a qualified electrician perform all wiring. This
fixture must be wired in accordance with all national and local
electrical codes.
Do not handle any energized fixture or attempt to energize any fixture
with wet hands or while standing on a wet or damp surface or in water.
ASSEMBLY INSTRUCTIONS
1. Preparing for installation
A. Disconnect electrical power at fuse or circuit breaker box before installing or servicing any part of this fixture.
B. Carefully remove the fixture from the carton, and check that all parts are included, as shown in figure below. Be careful not to misplace any
of the screws or parts which are needed for installing the fixture.
2. Wiring-all wiring must take place inside junction box.
Caution: Make sure power is off at fuse or circuit breaker box. Check power wires for damage or scrapes. If power supply wires are within
three inches of the ballast power supply, use wire suitable for at least 90C (194F). Note: Most dwellings built before 1985 have supply wire
rated to 60C. Consult a qualified electrician before installing.
A. Install two screws (3) (supplied) on gem bar (1) (supplied) leaving about 1 5/8” screw length exposed.
B. Secure gem bar (1) on the junction box (not supplied) with two screws (2) (not supplied).
C. Make all wire connections to appropriate wire. Secure with wire nuts (included).
D. Connect the green wires from the fixture and power source to the green screw on the gem bar (1).
E. The black wire from the fixture is connected to the black wire from power source.
F. The white wire from the fixture is connected to the white (neutral) wire from power source.
G. Tuck all connections neatly into junction box.
3. Mounting
A. Align backpan (4) mounting slotted holes with two screws (3). Place backpan over screws (3) and rotate it clockwise. Tighten screws (3).
B. Install stem (5) through the backpan into the gem bar. Secure stem with nut (6).
This fixture is designed for use in a 110-120VAC, 60Hz fused circuit.
Do not use on a dimming circuit.
To reduce the risk of electrical shock, and to assure proper operation,
this fixture must be adequately grounded. To accomplish proper
grounding, there must be a separate ground wire (green) contact
between this fixture and the ground connection of your main power
supply panel.
This fixture is intended to be used for general outdoor lighting in dry or
damp locations only.
8060651 R2
![](/html/a2/a2c3/a2c3aadb226991f8905ccd453884fb190490dab07a97fe238021d30468be457c/bg2.png)
Decorative Flushmount Fluorescent Ceiling Fixture
Limited Factory Warranty
American Fluorescent Corporation warrants this fixture is free from defects in materials and workmanship when installed and used under normal operating conditions
for a period of 2 years from date of purchase. This warranty covers all component parts and extends only to replacement of defective fixture or components; it does
not cover failure due to improper installation, misuse, mishandling or damage incurred in transit
Model: 324620 & C213PBPLT 120VAC / 60Hz
Lamp-Install appropriate lamp(s) (not provided) per label. Snap
lamp(s) (6) into lamp holder.
4. Diffuser-Install the diffuser (7) over threaded rod and secure
it with cover (8) and finial nut (9).
5. Restore power at fuse or circuit breaker box.
8060651 R2