AFL Technologies FAST SC, FAST LC, FAST ST Installation Manual

Page 1
FAST CONNECTOR TERMINATION AND ASSEMBLY INSTRUCTIONS
This document provides termination instructions for AFL’s FAST SC, LC and ST connectors. Read these instructions carefully before proceeding. Termination instructions are provided for 250 μm, 900 μm, 2 mm and 3 mm ber/cable. Different termination options after cleaving the ber are provided for each ber type. Please choose the best option for your application.
MATERIALS
6 7
1
2
3
4
5
16
8
14 18
15
17
19
20
21
9
11 12 13
10
FAST Connector Universal Tool Kit FAST SC Connector Kit FAST ST Connector KitFAST LC Connector Kit
1. Blue Tool Bag
2. Fiber Preparation Fluid
3. Lint-free Wipes
4. CT-30A Cleaver
5. Strip template
ORDERING INFORMATION
SC CONNECTORS
Fiber Type Color
Multimode 62.5/125 µm, OM1 Beige FAST-SC-MM62.5-6 FAST-SC-MM62.5-100
Multimode 50/125 µm, OM2 Black FAST-SC-MM50-6 FAST-SC-MM50-100
Multimode 50/125 µm 10G, OM3 Aqua FAST-SC-MM50L-6 FAST-SC-MM50L-100
Single-mode, UPC Blue FAST-SC-SM-6 FAST-SC-SM-100
Single-mode, APC-AU Green FAST-SC-SMAU-6 FAST-SC-SMAU-100
LC CONNECTORS
Fiber Type Color
Multimode 62.5/125 µm, OM1 Beige FAST-LC-MM62.5-6 FAST-LC-MM62.5-100
Multimode 50/125 µm, OM2 Black FAST-LC-MM50-6 FAST-LC-MM50-100
Multimode 50/125 µm 10G, OM3 Aqua FAST-LC-MM50L-6 FAST-LC-MM50L-100
Single-mode, UPC Blue FAST-LC-SM-6 FAST-LC-SM-100
6. FAST Assembly Tool
7. 0.25/0.9 mm Cable Clamp
8. 2 mm Cable Clamp
9. 3 mm Cable Clamp
10. Marker
AFL No. Pack of 6 Pack of 100
AFL No.
Pack of 6 Pack of 100
11. Kevlar® Scissors
12. Fiber Stripper
13. FAST Termination Instructions
14. Clear Protective Tubing
15. FAST SC Connector
ST CONNECTORS
Fiber Type Color
Multimode 62.5/125 µm, OM1 Beige FAST-ST-MM62.5-6 FAST-ST-MM62.5-100
Multimode 50/125 µm, OM2 Black FAST-ST-MM50-6 FAST-ST-MM50-100
Multimode 50/125 µm 10G, OM3 Aqua FAST-ST-MM50L-6 FAST-ST-MM50L-100
Single-mode, UPC Blue FAST-ST-SM-6 FAST-ST-SM-100
BOOT KITS
Item Description
2 mm Boot Kit, SC/LC/ST FAST-BOOT-2MM-6 FAST-BOOT-2MM-100
3 mm Boot Kit, SC/LC/ST FAST-BOOT-3MM-6 FAST-BOOT-3MM-100
TOOL KITS
Item Description AFL No.
FAST Universal Tool Kit with CT-30A Cleaver CS001201
FAST Universal Tool Kit with CT-05A Cleaver CS010975
16. 250 µm Tubing
17. 900 µm Boot
18. Clear Protective Tubing
19. FAST LC Connector
20. 250 µm Tubing
24
25
21. 900 µm Boot
22. Clear Protective Tubing
23. FAST ST Connector
24. ST Connector Housing
25. 250 µm Tubing
26. 900 µm Boot
AFL No.
Pack of 6 Pack of 100
AFL No. Pack of 6 Pack of 100
22
23
26
(800) 235-3423 • (864) 433-0333 • www.AFLglobal.com
Page 2
250 µm FIBER TERMINATION
1: Insert the clear protective tubing,
250 μm protective tubing and 900 μm boot onto the ber.
2: Strip 35 mm of 250 μm coating
from the ber.
3: Clean the ber with a lint-free
wipe and ber preparation uid.
TERMINATION OPTION A: MANUAL
1: Squeeze top and bottom of the
wedge to ensure that it is engaged.
2: Insert ber into connector. Bring
250 μm protective tubing forward. Create a slight bend in the ber to maintain connection.
3: Release the wedge clip by
squeezing both sides. Remove the wedge clip.
TERMINATION OPTION B: VISUAL FAULT IDENTIFIER (VFI)
4: Set the ber on the cleaver at the
10.5 mm cleave length. Cleave the ber.
4: Slide the boot onto the connector
body. Bring the clear protective tubing over the end of the 250 μm protective tubing. Termination is complete.
1: Squeeze top and bottom of
the wedge to ensure that the wedge is engaged.
2: Remove the dust cap.
Insert the connector into the VFI. Window 1 of the wedge clip will glow red.
FOR ST ONLY
Apply the connector housing to the connector body. You will not be able to reengage the wedge clip after the housing is applied.
3: Insert the ber into the
connector. Bring 250 μm protective tubing forward. The light will dim when a connection is made.
(800) 235-3423 • (864) 433-0333 • www.AFLglobal.com
4: Release the wedge clip by
squeezing both sides. Remove the wedge clip.
5: Slide the boot onto the
connector body. Bring the clear protective tubing over the end of the 250 μm protective tubing. Termination is complete.
Page 3
900 µm FIBER TERMINATION
1: If you are using a 900 μm
fanout/breakout kit, place into 900 μm cable clamp about 10" from the end of the cable.
2: Place the 900 μm boot on
the cable.
3: Strip 35 mm of 900 μm
and 250 μm coating off.
4: Clean the ber with a
lint-free wipe and ber preparation uid.
TERMINATION OPTION A: MANUAL
1: Squeeze top and bottom of the
wedge to ensure that it is engaged.
2: Insert the ber into the connector
with mark facing up. Create a slight bend in the connector to maintain connection.
3: Release the wedge clip by
squeezing both sides. Remove the wedge clip.
TERMINATION OPTION B: VISUAL FAULT IDENTIFIER (VFI)
5: Set the ber on the cleaver
at the 10.5 mm cleave length. Cleave the ber.
4: Slide the boot onto the connector
body. Termination is complete.
1: Squeeze top and bottom of
the wedge to ensure that the wedge is engaged.
2: Remove the dust cap.
Insert the connector into the VFI. Window 1 of the wedge clip will glow red.
FOR ST ONLY
Apply the connector housing to the connector body. You will not be able to reengage the wedge clip after the housing is applied.
3: Insert the ber into the
connector with the mark facing up. The light will dim when a connection is made.
(800) 235-3423 • (864) 433-0333 • www.AFLglobal.com
4: Release the wedge clip by
squeezing both sides. Remove the wedge clip.
5: Slide the boot onto the
connector body. Termination is complete.
Page 4
2 MM AND 3 MM FIBER TERMINATION
1: Place the cable into
the appropriate cable clamp about 10" from
2: Insert the appropriate
boot onto the cable.
3: Remove 70 mm of
cable jacket.
4: Strip off 35 mm of
900 μm and 250 μm coating.
the end of the cable.
TERMINATION OPTION A: FAST ASSEMBLY TOOL
1: Place the connector into
the assembly tool. Squeeze top and bottom of the wedge to ensure that it is engaged.
2: Insert the ber into
connector with mark upward until a slight bend is made in the ber.
3: Disengage the wedge
by squeezing both sides. Remove cable from assembly tool cable grip.
4: Divide the Kevlar® into
two portions and place them in the Kevlar® grips. Bring boot forward and screw on halfway.
TERMINATION OPTION B: MANUAL
5: Clean the ber with
a lint-free wipe and ber preparation uid.
5: Remove from
assembly tool. Remove wedge clip completely. Trim excess Kevlar Kevlar® scissors.
®
using the
6: Set the ber on the
cleaver at the 10.5 mm cleave length. Cleave the ber.
6: Screw the boot on
completely. Termination is complete.
1: Squeeze top and bottom
of the wedge to ensure that it is engaged.
2: Insert ber into connector
making sure the mark is facing up. Create a slight bend to maintain connection.
3: Release the wedge clip
by squeezing both sides. Remove the wedge clip.
4: Divide the Kevlar
evenly on both sides. Screw the boot on halfway.
®
TERMINATION OPTION C: VISUAL FAULT IDENTIFIER (VFI)
1: Squeeze top and
bottom of the wedge to ensure that the wedge is engaged.
2: Remove the dust cap.
Insert the connector into the VFI. Window 1 of the wedge clip will glow red.
3: Insert the ber into
the connector with the mark facing up. The light will dim when a connection is made.
4: Release the wedge
clip by squeezing both sides. Remove the wedge clip.
5: Divide the Kevlar
evenly on both sides. Screw the boot on halfway.
FOR ST ONLY
5: Trim excess Kevlar
using the Kevlar® scissors.
®
6: Trim excess Kevlar
using the Kevlar® scissors.
®
6: Screw the boot on
completely. Termination is complete.
®
7: Screw the boot on
completely. Termination is complete.
Place the connector into the assembly tool. Squeeze top and bottom of the wedge to ensure that it is engaged. You will not be able to reengage the wedge clip after the housing is applied.