Aervoe 1500 Energy Center Buddy OPERATING INSTRUCTIONS

Energy Center 1500 Buddy
OPERATING INSTRUCTIONS
Sierra Wave® Energy Center 1500 Buddy #9681
The Sierra Wave Energy Center 1500 Buddy is a secondary power storage unit that increases working capacity of the #9680 Energy Center 1500 to double the available power. The Buddy contains a rechargeable and replaceable 12V/120Ah AGM battery in an easy to maneuver metal housing with swivel caster wheels and telescoping handles. This makes it much easier to move around than standard 12V batteries. It also includes the 12V Battery Charging Cables to connect it to the Energy Center 1500 for charging and power draw.
Replacement battery #9682 may be purchased through aervoe.com.
IMPORTANT WARNINGS & SAFEGUARDS
Read all instructions thoroughly before operating this unit to avoid injury to self or property and avoid damage to the unit. Keep instructions handy for reference during use.
ENERGIZED EQUIPMENT - ELECTRICAL SHOCK & EXPLOSION HAZARD
GENERATES LETHAL VOLTAGE
DANGER
Do Not submerge in liquid or operate in wet environments. Device is not waterproof or
water resistant. Operate in dry environments only.
Do Not operate in flammable or explosive environments
Do Not operate if the unit is damaged in any way including loose electronics or if
charging cords are frayed and wires are exposed
Never cross connect POS (+) and NEG (-) terminals or battery cables
Do Not plug inverter 120V AC outlets into external 120V AC outlets of any kind
Do Not place foreign objects inside the power outlets
Do not replace fuses with larger amperage values
Do Not block the air inlets or vents
Not recommended for use or storage below 10º (-12ºC) or above 120ºF (49ºC). Place
out of direct sunlight to prevent overheating.
Not intended for use as an Uninterruptable Power Supply (UPS)
Administer close supervision when operating around children or persons with
disabilities
Do Not use to operate any medical life support equipment
Consult your physician before using with CPAP devices or other
non-life support medical equipment
The limited warranty described is the sole and exclusive warranty provided by Aervoe Industries, Inc. In no event will Aervoe be liable for any indirect or incidental damages or losses of any kind arising from or as a result of misuse or abuse, or the incorrect installation or operation of the product.
2
PARTS IDENTIFICATION
Main Power Switch & Key
Telescoping Handles
Interconnecting Terminal
The Buddy connects using the 12V Power Charging Cables
9680 1500 Watt Energy Center
(sold separately)
WIND&SOLAR HYBRID
CONTROLLER
Enter Esc
(-)(+)
ON OFF ON OFF
DC SWITCH
AC STATUS MONITOR
working
warning
fully charged
AC SWITCH
charging
Caster Wheels
12V Power Charging Cables
Interconnecting Terminal
3
SET-UP
1. Remove the Energy Center 1500 Buddy from its packaging and place on a level surface. Make sure caster wheels are moving freely and all packaging has been removed, especially around the COOLING FAN and vents.
2. Insert the telescoping handles into the mounted tubes on the back of the unit and clamp them securely at the desired height.
POWER CONTROL SWITCHES
MAIN POWER SWITCH & KEY: the main power switch has two functions.
1. Activates the battery, power inputs, and power outputs. Place in the
ON position during charging or when using power.
2. Security key. When in the OFF position, turn 45º to the left and
remove the key. This will make the Buddy inoperable to anyone without the key. Should be removed when stored for long periods.
MAIN POWER
SWITCH & KEY
INTERCONNECTING TERMINAL
The connection point that provides the input electrical charging from, and output power to, the Energy Center and the Buddy.
12V POWER CHARGING CABLES
24” cable provides the interconnection between the Energy Center and the Buddy. Includes heavy-duty Anderson Power Mod connectors with built-in non-reverse polarity protection.
BATTERY INFORMATION, INSTALLATION, AND SPECIAL PRECAUTIONS
The buddy includes a high efficiency AGM (absorbed glass mat) battery, which is valve regulated, sealed, and deep cycle rated. It offers long life cycle compared to traditional SLA batteries when charged and maintained according to operating instructions.
Service
The battery and fuse are the only user serviceable parts. All other repairs must be performed by Aervoe Industries or an authorized repair facility. Failure to follow these guidelines can damage the unit, cause injury and voids the warranty. Contact Aervoe for additional troubleshooting information.
ELECTRIC SHOCK - SHORT CIRCUIT & EXPLOSION HAZARD
GENERATES LETHAL VOLTAGE
Only qualified persons with experience handling 12V batteries and power systems should perform the removal and installation of this battery or fuse.
Follow all instructions and be familiar with the important safeguards listed.
Before removing the battery access panels, the user must make sure the MAIN POWER SWITCH is in the OFF position.
Remove all external power charging sources (AC, solar, or wind)
Remove any devices connected to power outputs (120V AC, 12V DC or USB).
4
Battery Replacement
In the event that the battery requires replacement, please follow these instructions. Aervoe recommends utilizing a qualified technician. Battery replacement instructions for the #9680 Energy Center 1500 are available on our website www.aervoe.com. IMPORTANT: replace with a matching 12V/120Ah AGM specified battery (#9682 available from Aervoe Industries, Inc.). Other batteries and capacities could produce incorrect charging or poor performance.
1. Turn the MAIN POWER SWITCH to the OFF position.
2. Disconnect all external batteries, cables, and devices.
3. Remove the side panels of the unit by carefully removing the screws using an Allen wrench or hex key.
4. Locate the battery (+) and (-) terminals and carefully remove the protective caps on the battery terminals.
5. Disconnect the Negative Terminal (-) cable from the battery and set aside. Should be placed to prevent arcing other cables and components.
6. Disconnect the Positive Terminal (+) cable.
7. Loosen the bolts that attach the battery to the metal frame and carefully remove the battery from the compartment. Do not disrupt any other electronics.
8. Replace with a new battery, reversing the previous steps. Before replacing the side panel double check that all connections are secure.
9. Once the battery is installed, it will need to be fully charged using any of the methods described in the following section.
10. Dispose of the used battery by contacting your local Hazard Waste Center.
Battery Fuse Replacement
Includes a 200A battery protection fuse and must be replaced with the exact type as listed in the technical specifications. Contact Aervoe Industries, Inc. at 800-227-0196 for replacement fuses and additional installation instructions.
1. Turn the MAIN POWER SWITCH to the OFF position.
2. Disconnect all external batteries, cables, and devices.
3. Remove the side panels of the unit by carefully removing the screws using an Allen wrench or hex key.
4. Loosen and remove the fuse from the fuse block and replace with a new fuse.
5. Before replacing the side panel double check that all connections are secure.
Connecting and Charging the Energy Center 1500 & Energy Center Buddy Together
1. Read the instructions provided with the #9680 Energy Center 1500
2. Place the Buddy within 2 ft. of the Energy Center so that the 12V POWER CHARGING CABLES reach the INTERCONNECTING TERMINALS of each unit.
3. Turn the MAIN POWER SWITCH to the OFF position on both units. NOTE: Failure to do so could cause damage to the unit.
4. Remove the DUST CAPS from the INTERCONNECTING TERMINALS on both units.
5. Use the 12V POWER CHARGING CABLES provided with the Buddy to connect the two units together. Securely insert each end of the CABLE into the TERMINALS of each unit (either end will work in either unit). Reverse polarity protection is built into the terminals.
6. The Buddy is now connected to the Energy Center 1500 for charging and disbursement of power. For additional information about either unit, please review the Product Data Sheet available on­line.
5
CHARGING
Charging
1. Follow the charging instructions for the #9680 Energy Center 1500.
2. First turn ON the MAIN POWER SWITCH on the Energy Center 1500 and then on the Energy Center Buddy.
3. For maximum efficiency and battery life, fully charge before first use, after each use, and every 30 days during storage.
4. Disconnect all power sources when not using.
5. The cooling fan on the Energy Center 1500 will run intermittently during charging to prevent overheating.
6. For faster charging, do not use the power output during charging.
CARE AND MAINTENANCE
Dust regularly with a clean dry cloth to prevent dust and dirt from building up on the vents and power inputs/outputs
Store inside in a clean, dry place when not in use. Keep from exposing to extreme cold and hot environments.
Charge after each use and every 30 days when stored so it is ready to use when needed
Turn all power switches OFF when not in use and remove the MAIN POWER SWITCH/KEY
TROUBLESHOOTING
If your Energy Center fails to operate as specified, follow these troubleshooting steps to correct the issue. If you still experience issues, please contact a Product Specialist at Aervoe Industries, Inc. at 800-227-0196 or www.aervoe.com.
Problem: Charging not working
If using 120V AC power, confirm the 120V AC POWER CORD is fitted securely in the input port of the Energy Center 1500 and electrical wall outlet; and that the GFI or circuit breakers have not been tripped
Make sure the MAIN POWER SWITCH is in the ON position of both units prior to charging and that the CHARGING LED is illuminated under the AC STATUS MONITOR of the Energy Center 1500
Verify the 10A AC protection fuse is not broken or missing (located above the 120V charging input of the Energy Center 1500). Replace with a new fuse if necessary as specified in this manual.
Verify the 12V battery fuse has not faulted (follow instructions in this instruction manual)
Check the 12V POWER CHARGE CABLES for damage and replace if needed.
If the problem has not cleared up, call Aervoe for further assistance.
SERVICE AND REPAIR
The battery and fuse replacement are the only features serviceable by the user. All other repairs must be performed by Aervoe Industries, Inc. or an authorized repair facility. Failure to follow these guidelines can damage the unit, cause injury, and voids the product warranty. Call Aervoe and ask to speak with a product specialist for additional instructions or troubleshooting information.
6
TECHNICAL INFORMATION
SPECIFICATIONS
BATTERY 12V DC/120Ah AGM deep cycle sealed
PROTECTION FUSE Battery: MIDI® style bolt-down fuse 32V/200A
12V DC INPUT & OUTPUT TERMINALS Anderson PowerMod
12V POWER CHARGING CABLES Size: 2AWG x 24” OAL with Anderson PowerMod connectors
OPERATING TEMPERATURE 32ºF TO 104ºF (0ºC TO 40ºC)
STORAGE TEMPERATURE -4ºF TO 120ºF (-20ºC TO 49ºC)
DIMENSIONS 26” x 10” x 18” (66 x 25.4 x 46cm)
WEIGHT 120 lbs. (54.5Kg)
Dimensions: 16” x 6.85” x 9’17” (407 x 174 x 209mm) Cycle Charge Life: 500 plus (based on 80% discharge and full recharge cycles)
CHARGE TIME
Times are estimates based on ideal power conditions. Actual times will
depend on the battery’s charge state and solar and wind conditions.
#9680 Alone #9680 & #9681 Together
120V AC Charging 8-10 hours 18-24 hours
Solar Charging: 1-#9590 120W Solar Collector 2-#9590 120W Solar Collectors
Wind Turbine Charging 10-20 MPH wind speed 20-25 MPH wind speed
12-14 hours
6-8 hours
15-18 hours
8-12 hours
24-28 hours 12-16 hours
25-35 hours 14-22 hours
120V AC DEVICE: SAMPLE RUN TIMES
18.8 cu. ft. Refrigerator (100-150W)
Based on an already chilled refrigerator.
DIY Paint Sprayer (100-150W) 8-10 hours 18-20 hours
Sump or Water Pump (150-200W) 6-8 hours 16-18 hours
Electric Power Tools 1-5 hours 2-10 hours
Portable Heater 1-3 hours 2-6 hours
Window Air Conditioner (750-1000W) 1-3 hours 2-6 hours
LED Industrial Lighting (50-100W) 10-12 hours 20-25 hours
Laptop (50-75W) 18-20 hours 36-42 hours
Large Flat Screen TV 5-10+ hours 10-20 hours
Microwave Oven (1000W) Up to 1 hour Up to 2½ hours
Times are based on a fully charged units. Actual times vary depending on device type/size and the output/load connected. All values are based on 80% depth of discharge
for batteries and normal AC inverter loss.
#9680 Alone #9680 & #9681 Together
8-10 hours 18-20 hours
12V & USB DEVICE: SAMPLE RUN TIMES
Times are based on a fully charged Energy Center 1500. Actual
times vary depending on device type/size and the output/load
connected. All values are based on 80% depth of discharge for
batteries.
7
#9680 Alone #9680 & #9681 Together
12V Thermoelectric Cooler (40-50W) 30 hours 62 hours
Max Burton Digital Stove To Go #6905 (100-130W)
Sierra Wave Portable/Rechargeable LED Work Light #9710 (10W continuous)
Sierra Wave Portable Area Lights #9721 (9W)
Tablets such as iPad, Kindle, etc. (10­12Wh)
11 hours 24 hours
120 hours 250 hours
130 hours 270 hours
Over 100 full recharges Over 200 full recharges
1-year performance warranty on all products from date of purchase. Report to home office or local Aervoe representative for examination. Because Seller cannot control Buyer’s handling or use of product, Seller makes no warranty expressed or implied when not used or stored in accordance with directions. This warranty is limited to repair or replacement of product within 30 days of receipt at the Aervoe office in Gardnerville, NV and on original purchase only. See enclosed warranty card for complete information.
AVAILABLE ACCESSORIES
Available at your local retailer or www.aervoe.com
#9680 Sierra Wave Energy Center 1500 (required)
#9682 12V-120Ah Replacement Battery
#9590 Sierra Wave 120-Watt Solar Collector
AERVOE INDUSTRIES, INC. Gardnerville, NV 89410 • 1-800-227-0196 www.aervoe.com • mailbox@aervoe.com
9681inst; cs2/14