Aero Pure VSF 110DH-S User Manual

6” Duct
Static Pressure (inches w.g.)
0.1
0.25
Air Volume (CFM)
110
79
Noise (sones)
0.6
n/a
Power Consumption (Watts)
11
11
Energy Efficiency (CFM/Watts)
10
7.2
Current (AMPS)
0.2
0.2
ENERGY STAR rated
Yes
Grille Dimensions
13 3/8” x 13 3/8”
Model
Qty
Comments
Project
Location
Architect
Engineer
Contractor
Submitted by
Date
Specifications
VSF 110DH-S SERIES
Slim Fit DC Bathroom Fan with Adjustable Speed
Control and Humidity Sensor
ETL Listed for installation over tub/shower enclosure with GFCI
circuit wiring.
Description: Super quiet DC (Direct Current) bathroom fan with adjustable speed control (80-140 CFM) engineered for continuous run Integrated user adjustable humidity sensor Ceiling or wall mount Suitable for new construction or remodeling HVI certified ENERGY STAR qualified ETL listed for use in insulated ceilings (Type I.C.).
Motor/Blower: Permanently lubricated enclosed brushless DC motor engineered for continuous energy efficient operation; power rating 120v/60Hz; motor equipped with thermal shut off.
Housing: Rugged 26 GA galvanized steel; detachable 4” and 6” duct connector with built-in back draft dampener; 2 anti-vibration hangar bar brackets adjustable to 24” span included.
Finishes: White (W); Satin Nickel (SN); Oil Rubbed Bronze (OR).
Installation: Must be installed by a licensed professional. Complete
installation instructions included.
User-Adjustable Integrated Sensor: Humidity sensor adjustable from 50-100% relative humidity (RH); responds to a.) rapid to moderate rise in humidity or b.) .humidity above preset RH set point.
Warranty: 6 Years
Architect’s Specifications: Ventilation fan will be ceiling or wall mount, ENERGY STAR qualified, adjustable speed of 80-140 CFM and no more than 0.6 sones at 110 CFM as certified by HVI at 0.1 Ps (inches water gauge). Power consumption shall be no greater than 11 watts and ENERGY STAR rated with efficiency rating of no less than 10 CFM/watt. The motor will be enclosed brushless DC motor, engineered
for continuous operation. Duct diameter will be 4” or 6” round. CFM
switch tab will allow for 5 separate airflow (CFM) settings for 4” or 6” duct. Fan will begin operation when humidity rises above user adjustable setpoint (50-100% RH). Fan shall be ETL/cETL listed for tub/shower enclosure when used with GFCI branch circuit wiring and shall be ETL/cETL listed for use in insulated ceiling (Type I.C.). Fan shall be ASHRAE 62.2, LEED, CalGreen, and WA Ventilation Code compliant.
Aero Pure, L L C 1006 B a n k t o n Circle St e B H a n a h a n , SC 29 4 10 843.37 7 . 8 6 4 2
www.a e r o p u refa n s . c om