![](/html/fb/fb3d/fb3d851947ebd2e5d25b6107fac158ad64f9d9092997812e1fe415b164710840/bg1.png)
Model No.
BATH FAN
INSTALLATION INSTRUCTIONS
ABF110DHG5 Series
ABF110DHL5 SeriesABF110DHG6 Series ABF110DHL6 Series
READ AND SAVE THESE INSTRUCTIONS
Thank you very much for purchasing our bath fan.
Please read the instructions carefully before attempting to install,
operate or service our ventilating fan. Failure to comply
with instructions could result in personal injury or property
damage. Please retain this booklet for future reference.
TABLE OF CONTENTS
UNPACKING
SUPPLIED ACCESSORIES
DESCRIPTION
GENERAL SAFETY INFORMATION
DIMENSIONS
WIRING DIAGRAM
FEATURES
INDICATION (PLUG-IN DEVICES)
INSTALLATION
INSTALLATION
MAINTENANCE (CLEANING)
PRACTICAL GUIDE TO INSTALLATION
SPECIFICATIONS
WARRANTY
..............................................................................................................
.......................................................................................
..........................................................................................................
........................................................................
............................................................................................................
...................................................................................................
..................................................................................................................
...........................................
I (NEW CONSTRUCTION)
II (RETROFIT)
......................................................................................................
...............................................................................................................
.................................................................................
...................................................................................
.............................................................
...................................................................
02
02
02
03
04
05
05
06
07
11
13
14
14
15
![](/html/fb/fb3d/fb3d851947ebd2e5d25b6107fac158ad64f9d9092997812e1fe415b164710840/bg2.png)
UNPACKING
Unpack and carefully remove the unit from carton.
Refer to the supplied accessories list to verify that all parts are present.
SUPPLIED ACCESSORIES
Grille
Suspension
bracket
assembly
Long screw
(ST4X30)
Wire
Protector
Nut
Installation
instructions
or oror
ABF110DHG5 ABF110DHG6 ABF110DHL5 ABF110DHL6
1
1
5
1
1
DESCRIPTION
These bath fan models are listed by ETL under ETL file No.5011292.
These bath fan models use a Sirocco fan driven by a brushless DC motor.
The motor is designed to have an extended service life with reduced energy consumption.
The grille covering the fan body is a spring-loaded, quick attach type. A damper for preventing air
counterflow is provided.
The suspension bracket assembly can be used for both new and retrofit situation.
The light uses a bright SMD LED.
2
![](/html/fb/fb3d/fb3d851947ebd2e5d25b6107fac158ad64f9d9092997812e1fe415b164710840/bg3.png)
GENERAL SAFETY INFORMATION
Do not install this ventilating fan where interior room temperature may exceed
1.
104°F (40°C).
Make sure that the electric service supply voltage is AC 120V, 60Hz.
2.
Follow all local electrical and safety codes, as well as the National Electrical
3.
Code (NEC), and the Occupation Safety and Health Act (OSHA).
Always disconnect the power source before working on or near the fan, motor,
4.
light fixture, or junction box.
Protect the power cord from sharp edges, oil, grease, hot surfaces, chemicals
5.
or other objects.
Do not kink the power cord.
6
Do not install the unit where ducts are configured as shown in Fig.A.
7.
Provide make up air for proper ventilation.
8.
CAUTION:
1.For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2.Not for use in cooking area. (Fig.B)
3.This product must be properly grounded.
WARNING:
To reduce the risk of fire, electric shock, or injury to persons, observe the following:
1.
Use this unit only in the manner intended by the manufacturer. If you have any questions, contact
the manufacturer.
2.
Before servicing or cleaning unit, switch power off at service panel and lock the service
disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a prominent warning device, such as a
tag, to the service panel.
3.
Installation work and electrical wiring must be done by qualified person(s) in accordance with
all applicable codes and standards, including fire-rated construction.
4.
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney)
of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacture′s
guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society of Heating, Refrigeration, and air conditioning Engineers
(ASHRAE) and the local code authorities.
5.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden
utilities.
6.
Ducted fans must always be vented to the outdoors.
7.
If this unit is to be installed over a tub or shower, it must be marked as appropriate for the
application and be connected to a GFCI (Ground Fault Circuit Interrupter)-protected branch circuit.
8.
These models are ETL listed for tub and shower enclosures.
9.
Not to be installed in a ceiling thermally insulated to a value greater than R40. (This is required for
installation in Canada only).
3
![](/html/fb/fb3d/fb3d851947ebd2e5d25b6107fac158ad64f9d9092997812e1fe415b164710840/bg4.png)
DIMENSIONS
Model: ABF110DHG6 Series, ABF110DHL6 Series
③
②
⑩
10 1/4 (260)
12 1/8 (308)
⑦
①
⑧
Model: ABF110DHG5 Series, ABF110DHL5 Series
③
②
⑦
5 4/5 (147)
4 7/8 (123)
3 7/8 (98)
5 4/5 (147)
4 7/8 (123)
3 7/8 (98)
⑤
3 4/5 (97)10 2/5 (265)
④
7 1/3 (186)
Unit: inches (mm)
⑥
⑨
13 (330)
3/5 (14.5)
⑨
⑩
7 1/3 (186)
3 4/5 (97)
⑪
①
10 1/4 (260)
12 1/8 (308)
④
13 (330)
⑧
⑥
Blade
1
Grille
2
Adaptor
3
Damper
3/5 (14.5)
4
Frame assy
5
Knockout plate
6
Junction box
7
10 2/5 (265)
⑤
Base PCB box
8
Humidity sensor module
9
CO sensor module
10
2
Night light module
11
Motion sensor module
12
LED light
13
⑫
4
![](/html/fb/fb3d/fb3d851947ebd2e5d25b6107fac158ad64f9d9092997812e1fe415b164710840/bg5.png)
WIRING DIAGRAM
Model: ABF110DHG5 / ABF110DHG6
Fan body
Motor
Yellowgreen
Junction box
P
C
B
White
Red
Red
Black
Green
Neutral
Control switch
Signal
Signal
Live
Ground
FEATURES
Multi-Speed
Flow-Selection
Air Volume(CFM)
50
80 110
80
70
90
60
50
0
Time delay
Air trimming
●CFM-Selection. Choose 50-80-110CFM; default is high speed.
Air Trimming
Time(min)
H
30
20
L
10
45
100
5
60
0
●Multi-Speed- Switch allows fan to run at continuous lower speed to
meet Indoor Air Quality. For example, when Flow-Selection setting is
80CFM, Multi-Speed can be chosen 0, 50, 60, or 70CFM as a
low speed.
Power switch
Model: ABF110DHL5 / ABF110DHL6
Fan body Junction box
Neutral
White
Motor
Yellowgreen
Light Body
P
C
B
Brown
White
Blue
Red
Red
Black
Green
Signal
Signal
Live
Ground
Live (Light)
Neutral
Live(N. Light)
Control switch
Power switch
●Delay- Switch for time delay setting. Setting range is 0, 5, 10, 20,
30, 45, or 60 minutes.
●Air Trimming- Switch allows fine-tuning of air volume when the
actual airflow is lower than set.
INSTRUCTIONS:
Turn the power on.
①When the control switch is turned on, the fan will run continuously at high speed only. The power
must be on before turning the control switch on. The sensors will not work and Time Delay Switch
does not apply to this mode.
②When the control switch is turned off, the fan will run at chosen low speed on Multi-Speed switch
continuously, and boost to the high speed when the sensor detects an increase in Relative
Humidity. The fan will run at high speed for amount of time selected from the Time Delay Switch
before returning to lower speed when the Relative Humidity falls below the set point.
5