Aero Mist 60100K User Manual

LIMITED WARRANTY
Aeromist, Inc. shall warrant the components of the Pump (Model 60100K) to be free of defects in workmanship for one year. This warranty does not apply to malfunctions caused by the fault or negligence of the buyer or third party, including failure to perform periodic maintenance. No warranty of merchant ability or other warranty, expressed or implied, is made.
The buyer agrees that the sole and exclusive remedy in law or in equity for breach of any and all warranties and the sole and exclusive remedy for the manufacturer’s liability of any kind (including without limitation, liability for neg ligence) with respect to the product and all other performance by the manu facturer will be limited to the repair of, or at the MANUFACTURER’S OPTION, THE REPLACEMENT OF THE PRODUCT. Buyer further agrees that the manu facturer will, in no event have any responsibility or bear any liability for (a) the cost of labor for the removal of any defective product or the installation of any replacement product, or (b) the cost of transportation to the manufacturer of the defective products returned for evaluation. Finally, buyer agrees that the manufacturer shall not be liable for any other loss or damage (including, without limitation, lost profits), even if the manufacturer has been advised of the possibility of such potential loss or damage.
-
-
-
-
INSTALLATION INSTRUCTIONS
23610 N 20th Dr, Ste 6, Phoenix, AZ 85085
(602) 454-8900
www.aeromist.com
LI ST OF ALL ENCLOSED PA RTS
QTY PART NO DESCRIPTION
1 60100K Direct-Drive Pump 1 56402 Flexible Nylon Tubing 25' Roll 1 52000 Automatic Drain Valve
57020 MAINTE NA NCE KIT
QTY PART NO DESCRIPTION
1 57011 Filter Element 1 57025 Pump Oil
IN STALLATION INSTRUCTIONS
• WARNING: Before plugging in the unit for the fi rst time, read the following section carefully. To reduce the risk of electric shock. Plug in supplied grounded cord into a properly grounded receptacle. When servicing this unit, unplug power cord before attempting any service or repairs.
• Install pump above grade level on a pre-formed concrete pad, 16"×16" minimum size.
• Plug power cord of unit into a properly grounded receptacle.
• Connect water line to water inlet connector.
• Unit is pre-fi lled with oil and ready to run. Oil should be half full on the sight glass when unit is off. Do not overfi ll
• On new misting systems, fl ush lines before installing nozzles. The pump will not build pressure until all nozzles are installed.
• Do not exceed 1000 PSI and do not run pump without water.
• Winter shutdown: Unplug pump power cord, shut off water supply, remove fi lter bowl and drain water. Also drain water out of all lines, to prevent damage to pump or lines.
• 25 feet or more of nylon tubing is recommended in order to reduce vibration noise.
.
DIRECT DRIVE PUMP SPECIFICATIONS
MODEL FLOW VOLTS MOTOR PUMP LOAD DIMENSIONS
GPM 60 Hz HP RPM Amps L x W x H 60100K 1.0 120 0.75 1725 10.4 24x15x13
Maximum pressure is 1000 PSI, normal operating pressure is 800-1000 PSI.
RECOMMENDED MIN-MAX NOZZLE RANGE
NOZZLES NOZZLES NOZZLES
Nozzle Size .014 .012 .008
Nozzle Range 12–25 15–30 22–45
Choose .012/.014 nozzles for dry climates and .008 for more humid climates.
Regulator
(Normal operating pressure 800-1000 PSI.
Pressure not to exceed 1000 PSI)
Liquid-Filled
Pressure Gauge
Outlet
To Misting Feed Line
Automatic
Drain Valve
ANNUAL MAINTENANC E INSTR UCTION S
• Change oil every 500 hours of runtime or once a year. Use approved Pump Oil (52025). Oil should be half full on the sight glass when
unit is off. Do not overfi ll
• Change Filter Element Annually
.
On/Off Switch
Power Cord
Water Inlet
Oil Filler/Breather Cap
Oil Sight Glass
Filter Bowl
With Replaceable 5-Micron Filter Element
Oil Drain
Loading...